Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance NAI BASTI REASI JAMMU AND KASHMIR INDIA | REASI | JAMMU AND KASHMIR | 182312 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-already exceeded MAD/turnover, so e-bids rejected |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-Limit of turnover (MAD) is already exceeded, so e-bids rejected as decided by tender committee |
Tender Value
Refer Docs
EMD Value
₹17,340
Closing Date
14 Jul 2022, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
upgradation of substation
2022_PDD_175500_1
ED/UDH/29 of 2022-23, dt. 22-06-2022
Open Tender
Electrical Works
Turn-key
90 days
at Latyar, Nowara Lower Meer and Prayai, Kultyar
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Executive Engineer Electric Division JPDCL
₹17,340
22 Aug 2022
23 Jun 2022
16 Jul 2022
23 Jun 2022
14 Jul 2022
23 Jun 2022
23 Jun 2022 - 30 Jun 2022
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Upgradation of 25 KVA Electricity transformer 63 KVA at Latyar-III Pyt. Latyar under DDC Grants.
11/0.433kV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11 KV GO Switch 3 phase, 3 pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² Single Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
LT Distribution Box for 63 KVA DTR with MCCB for incomer and Switch Fuse Units for outcoming circuit
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber with RCC slab cover.
Cement Bottoming 1:2:4 mix as per REC Standards 0.5 cum per pole
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Upgradation of 25 KVA Electricity transformer 63 KVA at Nowara (Lower Meer) under DDC Grants.
11/0.433kV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11 KV GO Switch 3 phase, 3 pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² Single Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
LT Distribution Box for 63 KVA DTR with MCCB for incomer and Switch Fuse Units for outcoming circuit
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber with RCC slab cover.
Cement Bottoming 1:2:4 mix as per REC Standards 0.5 cum per pole
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Upgradation of 25 KVA Electricity transformer 63 KVA at Prayai Pyt. Kultyar under PRI Grants.
11/0.433kV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11 KV GO Switch 3 phase, 3 pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² Single Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
LT Distribution Box for 63 KVA DTR with MCCB for incomer and Switch Fuse Units for outcoming circuit
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber with RCC slab cover.
Cement Bottoming 1:2:4 mix as per REC Standards 0.5 cum per pole
AJAY KAPOOR
vachapati sharma
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .