Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.0 LAccepted-AOC NO 1 1ST MAIN ANANDNAGAR ATRIA INSTITUTE OF TECHNOLOGY CAMPUS HEBBAL BANGALURU 560 024 | BENGALURU URBAN | KARNATAKA | 560024 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹57.6 L+₹66,840.25 (1.17%)Rejected-AOC NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹62.8 L+₹5.8 L (10.3%)Rejected-AOC 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹67.9 L+₹11.0 L (19.4%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹68.9 L+₹11.9 L (21.0%)Rejected-AOC NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | L5 | Rejected-AOC NOT LOWEST |
| Sl No | Description | Qty | Unit | Eeguchi Constructions L1 | PRAGATHI BUILDERS L5 | VIKAS CONSTRUCTIONS L6 | K. VENKATESH NAIDU L3 | SRI GANESH ENTERPRISES L2 | J R CONSTRUCTIONS L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down of existing Water Proofing treatment of any type (APP Membrane,Cement or earthen tile, Mud phuska or lime concrete) including cement plaster of any thickness and removing bitumen coating/mud pushka dirtsetc over original RCC roof slab by grinding, Picking, sweeping clean and washing down with water to remove dust & to providing water proofing treatment complete all as specified and as directed. directed
Note : Quoted rate deemed to be included for removing debris outside defence land exc 500m but not exc 1 KM. | 350 | Sqm | 65 ₹22,750 | 60 ₹21,000 | 90 ₹31,500 | 49 ₹17,150 Lowest | 120 ₹42,000 | 55 ₹19,250 |
| 2.00 | M&L for Plain cement concrete (1:2:4) type B-0 using 12.50mm graded crushed stone aggregate as in roof padding for water proof treatment including demolition of existing PCC complete all as specified and as directed. directed | 12.88 | Cum | 6,500 ₹83,720 | 6,000 ₹77,280 | 6,800 ₹87,584 | 5,009 ₹64,515.92 Lowest | 5,800 ₹74,704 | 6,500 ₹83,720 |
| 3.00 | M & L for water proofing treatmennt over RCC roof slab all as per following specification complete all as specified and directed :-
(i) Removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth
(ii) Rendering 10mm thick in CM (1:3) mixed with approved liquid water proofing compound as per manufacturers instructions finished even & smooth
(iii) Applying compatible primer/bonding bitumen @ 0.40 Litre/Sq m
(iv) Applying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.80kg/Sq m reinforced with non woven polyster/HMHDPE matt black finished over and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions
(v) Applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sq m
(Note : Supply only liquid water proofing will be measured & paid seperately.) | 350 | Sqm | 610 ₹2,13,500 | 700 ₹2,45,000 | 520 ₹1,82,000 Lowest | 809 ₹2,83,150 | 520 ₹1,82,000 Lowest | 720 ₹2,52,000 |
| 4.00 | Supply only liquid water proofing compound, ISI marked, complete all as specified & directed. | 13.63 | Litre | 180 ₹2,453.4 | 120 ₹1,635.6 | 120 ₹1,635.6 | 49 ₹667.87 Lowest | 60 ₹817.8 | 200 ₹2,726 |
| 5.00 | Disconnecting existing tanks of capacity exc 250 & not exc 500litres, setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required and reconnecting and re-fixing in position complete all as specified & directed. | 7 | Each | 280 ₹1,960 | 600 ₹4,200 | 300 ₹2,100 | 150 ₹1,050 Lowest | 200 ₹1,400 | 1,000 ₹7,000 |
| 6.00 | M & L for rotational moulded, triple layer polythene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisting and fixed in position on roofs including PTMT Float valve 20 mm dia with alumunium rod & PVC ball and fittings including dismantling existing water storage tank, complete all as specified & directed. | 11 | Each | 5,900 ₹64,900 | 6,000 ₹66,000 | 5,000 ₹55,000 | 4,999 ₹54,989 | 4,600 ₹50,600 Lowest | 5,000 ₹55,000 |
| 7.00 | Supply & laying CPVC pipes 20 mm outer dia SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 15 mm G I tubing and connections complete all as specified & directed. | 152 | RM | 280 ₹42,560 | 280 ₹42,560 | 290 ₹44,080 | 275 ₹41,800 | 180 ₹27,360 Lowest | 360 ₹54,720 |
| 8.00 | Supply & laying CPVC pipes 25 mm outer dia SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 20 mm GI tubing and connections complete all as specified & directed. | 80 | RM | 300 ₹24,000 | 300 ₹24,000 | 390 ₹31,200 | 390 ₹31,200 | 240 ₹19,200 Lowest | 400 ₹32,000 |
| 9.00 | S&F in repairs CPVC gate valves with lever , screwed both ends for iron pipe 20mm dia and fixed complete all as specified & directed. | 6 | Each | 250 ₹1,500 Lowest | 1,500 ₹9,000 | 450 ₹2,700 | 550 ₹3,300 | 400 ₹2,400 | 650 ₹3,900 |
| 10.00 | S&F in repairs CPVC gate valves with lever , screwed both ends for iron pipe 25mm dia and fixed complete all as specified & directed. | 14 | Each | 350 ₹4,900 Lowest | 2,000 ₹28,000 | 850 ₹11,900 | 700 ₹9,800 | 450 ₹6,300 | 750 ₹10,500 |
Tender Value
₹68.9 L
EMD Value
₹1.3 L
Closing Date
26 Dec 2025, 6:00 pmClosed
CWE (ARMY) BANGALORE
CWE ARMY BANGALORE, 101 Dickenson Road Bangalore 560042
SPECIAL REPAIRS TO BLDGS No P-215, ADDN / ALTN TO BLDG No P-213 AT KATOCH LINE AND CATTLE FENCING AROUND BLDG No P-227 UNDER GE (NORTH) BANGALORE
2025_MES_741979_1
86482/E8
Open Tender
Civil Works
Item Rate
180 days
CWE (ARMY) BANGALORE
As per Tender
8 documents required · 8 mandatory
₹1,000
GE (NORTH) BANGALORE
₹1.3 L
31 Mar 2026
28 Nov 2025
2 Jan 2026
28 Nov 2025
26 Dec 2025
19 Dec 2025
28 Nov 2025 - 5 Dec 2025
Taking down of existing Water Proofing treatment of any type (APP Membrane,Cement or earthen tile, Mud phuska or lime concrete) including cement plaster of any thickness and removing bitumen coating/mud pushka dirtsetc over original RCC roof slab by grinding, Picking, sweeping clean and washing down with water to remove dust & to providing water prooling treatment complete all as specified and as directed. directed Note : Quoted rate deemed to be included for removing debris outside defence land exc 500m but not exc 1 KM.
M&L for Plain cement concrete (1:2:4) type B-0 using 12.50mm graded stone aggregate as in roof padding for water proof treatment complete all as specified and as directed. directed
M & L for water proofing treatmennt over RCC roof slab all as per following specification complete all as specified and directed :- (i) Removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth (ii) Rendering 10mm thick in CM (1:3) mixed with approved liquid water proofing compound as per manufacturers instructions finished even & smooth (iii) Applying compatible primer/bonding bitumen @ 0.40 Litre/Sq m (iv) Applying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.80kg/Sq m reinforced with non woven polyster/HMHDPE matt black finished over and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions (v) Applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sq m (Note : Supply only liquid water proofing shall be paid seperately.)
Supply only liquid water proofing compound, ISI marked, complete all as specified & directed.
Supply & laying CPVC pipes 20 mm outer dia SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 15 mm G I tubing and connections complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed
M&L for mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410- W(Gde- E-250) quality-B all as specified and as directed
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of sheet of any type and any thickness complete all as specified and directed.
Taking down cement plaster of any description including racking out joints, hacking for key and disposal of debris all as specified and as directed.
M&L for Rendering 15mm thick cement mortar (1:6) on brick or concrete wall surfaces finished even and smooth without using extra cement all as specified and as directed.
M & L for Preparation of newly plastered wall surfaces and applying two coats of Acrylic distemper emulsion over a coat of self primer etc complete all specified and as directed.
S&F Second class hard wood plain, solid, straight chowkats and frames, wrought, frame rebeated on the solid , rounded or chamfered, put tegether with glue pinned at joints etc complete all as specified and as directed
S&F for mild steel work Bands, hold fasts, straps, and similar small articles conforming to Fe-290 Gde-E-165 all as specified & directed.
M & L for plain cement concrete (1:3:6) type C-0 using 12.50mm grade stone aggregate for filling of steel door frame/box type steel window/vent all as specified & directed.
S&F Second class hard wood 35 mm thick made glazed and skeleton shutters open rebated and prepared to receive glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as spfd in SSR Part-1, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified and as directed ( Note: Supply & fixing of 4 mm thick sheet glass or wire mesh be measured and paid separately.)
S & F Plain framed, panelled shutter (two panel) of 35mm thick with lock rail and panel of 9mm BWP commercial ply or 12mm venereed particle board with commercial veneering on both faces. rail and style are of 2nd class hardwood & the size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treateds fixed to chowkhat all as specified and as directed.
M & L for Solid PVC door frame (Single rebated) of size 60 mm x 30 mm made out of solid foam with homogenious fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100x8 sheet metal CSK screws complete all as specified and directed (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
M & L for Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, wood free EPS, supplying & fixing in frame at site complete all as specified and directed
M&L for preparing new wooden surface of any description, not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed
M & L for powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed
M & L for powder coated (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, r
S&F Anodised aluminum powder coated (of any shade/colour as approved by GE ) ventilators of size 500x850 mm with adjustable 4mm thick figured glass louvers, fixed in half portion, without sash bars, aluminum section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, including stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.18mm including complete etc all as specified and directed.
M & L for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
Supply & fix Sheet glass 4mm thick ordinary quality and glazing with oil or in wooden /steel /aluminium /rubber beadingputty in square exceeding 0.5 Sqm in each pane and all as specified.
Supply & fix Sheet glass 4mm thick ordinary quality and glazing with oil putty or in wooden /steel /aluminium /rubber beading in square not exceeding 0.5 Sqm in each pane and all as specified.
Supply & fix stainless steel wire cloth 0.36mm nominal dia and average width of aperture 1.40mm and fixed with tinned tack or galvanized wire staple all as directed fixed.
S&F Aluminium anodised tower bolt 150mm long of extruded section etc complete all as specified and as directed
S&F Aluminium handle 125mm size, cast type, anodised etc complete all as specified and as directed
S&F in repairs stainless steel decorative curtain rod of 20mm dia bore with wood finishes (weight not less 300 gms per running meter) including fancy finale caps cap etc complete all as specified and as directed
S & F cupboard knobs 40 mm dia fixed with nut, screw and washer of Brass, polished complete all as specified and as directed.
Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed.
Dismantling of floor, hearth or wall tilling incl cement mortar bedding (but not backing) and removing rubbish off from premises all as specified and as directed.
M&L for Coloured vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortar 20 mm thick cement mortar (1:4) all as specified and as directed.
M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes all as specified and as directed.
M & L for Plain cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in sub base to flooring 25mm thick finished even all as specified and as directed.
M & L for coloured Glazed ceramic tiles in vertical surfaces of size 350 x 250x 7 mm / 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over & including backing coat 10mm thick cement mortar (1:4) all as specified and as directed.
Material and labour for water proofing to sunken portions of WCs, bathroom and kitchen etc by applying water based, cold applied, single component, elastomericin-situ seamless monolithic coating ready to use acrylic modified bituminous liquid membrance with the procedure in sequence all as specified and as directed. SURFACE PREPARATION (i) Removing all loose gravel, dirt, oil, grease and foreign matter by jet of dry air and cleaning the surface mechanically or by grinding to make it smooth before application. (ii) Repairing all cracks by cutting “V” groove and fill with PMC mortar prepared in the ratio of Shalicrete : cement : sand (1:2:5) or equivalent. (iii) Providing 50 mm x 5
0 mm coving made out of PMC mortar as above. MATERIAL PREPARATION (i) Stir TarFelt® LM or equivalent by a slow speed mixture (approx. 400 rpm) fitted with a suitable mixing paddle to ensure a homogenous mix. (ii) After stirring, wait for the product to settle in order to let entrapped air escape.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar all as specified and as directed.
M & L for Granite 18 to 20 mm thick of any type work (table rubbed and polished) in steps, riser, tread, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite ,including cutting and polishing laid over & including 15 mm thick screed bed in CM 1:4 set and jointed complete all as specified & directed.
M & L for Providing edge moulding to 18-20mm thick granite stone any description of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified & directed.
M & L for Complete removal of existing treatment of ceiling surface of any description and applying three coats of white wash etc complete all specified and as directed.
M & L for Complete removal of existing treatment on walls surface of any description and finish as per following specification complete all specified and as directed :- (i) Applying 1 mm thick wall care putty finish to smooth surface (ii) Apply a coat of alkali resistant primer (iii) Applying two coats of Acrylic emulsion distemper
Demolition of brick/stone/boulder /precast concrete articles and precast concrete block built in cement mortar etc complete all as specified and as directed.
M&L for Pre-cast cement concrete (1:3:6) type C1 using 20mm graded stone aggregate as in solid block masonry exc 10cm in width and setting in CM (1:6 ) complete all as specified and as directed.
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep and getting out in hard/dense soil complete all as specified and as directed.
Excavating in post holes (or similar holes) in hard/dense each n exc 0.5cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick all as complete and as specified.
M & L for Plain Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete all as specified and directed.
M & L for Plain Cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete all as specified and directed.
S & F Mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Supply only chain link fencing any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire all as specified and as directed.
M & L for Mild steel screw bolts (machine made) 10mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long all as specified and as directed.
M & L for Mild steel round bar bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for rendering 15 mm thick cement mortar (1:4) on fair faces of bricks or concrete surfaces finishing the surface even and smooth without using extra cement complete all as specified & directed
M&L for preparation of newly plastered surfaces of walls and applying two coat of cement base paint over a coat primer complete all as specified and as directed.
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering, and well ramming in layers not exc 25 cm thick all as specified and as directed.
Removal of excavated earth to a distance not exc 50m and depositing at palace where directed and at a level not exc 1.50 m from the starting point all as specified and as directed.
M & L for Concealed Point Wiring with PVC insulated unsheathed cable 1.5 Sqmm single core 1100 volts grade multistranded FRLS copper conductor conforming to IS 694 drawn through and including concealed non-metalic rigid PVC conduit medium grade with accessories including GI/ MS branded sunken boxes of suitable module concealed in walls including modular frame and cover of suitable module fixed with cadmium / heylam plate, iron screws , housing modular type switches, switch socket outlets, fan regulators etc., including 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly all as specified and as directed for the following :-
One light point controlled by one switch
One fan/exhaust point controlled by one switch/regulator
One 3 pin socket out let 5 Amps on independent board
One bell/buzzer point controlled by bell push
One 3 pin socket out let 5 A on same board
One light point controlled by two way switch
M & L for concealed Point Wiring with PVC insulated u
nsheathed cable 2.5 Sqmm single core 1100 volts grade multistranded FRLS copper conductor conforming to IS 694 drawn through and including concealed non-metalic rigid PVC conduit medium grade ISI marked with accessories including GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium/heylam plate, iron screws , housing modular type switches, switch socket outlets, fan regulators etc., including 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Note for Item No 114 to 115 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the quoted rate. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls deemed to be included in the quoted rate.
S&F LED batten with luminaire 10 Watts capacity 2 feet long suitable for indoor applications with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories all as specified and directed.
Supply and fix Slim surface mounted round LED down lighter of 12 watt capacity, aluminium die cast body with premium diffuser to ensure glare free & even distribution of light all as specified and directed.
Supply and fix LED luminaries, round 18 watt PERARL + LED Slim surface panel mounted type suitable for indoor application, complete with all accessories including connecting up twin core twisted flexible copper conductor cable all as specified and directed.
Supply and fix Modular switch 1 way 6Amps,1 module all as specified and directed.
Supply and fix Modular switch 1 way 16Amps, 1 module all as specified and directed.
Supply and fix Modular switch 2 way 6Amps,1 module all as specified and directed.
Supply and Fix Modular Bell push 6Amps 1 module all as specified and directed.
Supply and fix modular Socket, 6Amps - 2/3 pin combined 2 module all as specified and directed.
Supply and fix modular Socket 6A / 16A - 2/3 pin combined 2 module, all as specified and directed.
Supply and fix modular type Fan step regulator, 120Watts - 2 module all as specified and directed.
S&F Angle holder PVC/polycarbonate type, 230volts all as specified and as directed
S&F in repair MCB SPN 240 volts 32 Amps C curves complete all as specified and as directed
S&F in repair MCB single pole 240 volts 6 to 32 Amps, C curves complete all as specified and as directed
S&F in repair MCB single pole 240 volts 40 Amps, C curves complete all as specified and as directed
S&F in replacement of MCB TPN 415 volts 63 Amps, C curves complete all as specified and as directed
S&F in repair MCCB, 4 pole 415 volts 100 Amps, 16 KA, fixed type complete all as specified and as directed
S&F in repair MCB Distribution Board SPN 8 way, double door type, 240 volts with 200 Amps rated busbar all as specified and as directed.
S&F in repair MCB Distribution Board SPN 4 way, double door type, 240 volts with 200 Amps rated busbar all as specified and as directed.
S&F in repair Vertical Distribution Board TPN 6 way suitable for MCCB 100 Amps as I/C, double door type 415 volts, IP :54 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 with insulated bus bar assembly all as specified and as directed.
S&F in repair Vertical Distribution Board (Optium F1 + 12) suitable for MCCB upto 125 Amps and 12 no of outgoing MCB as I/C, double door type 415 volts, IP :54 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 with insulated bus bar assembly
S&F Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
S&F in repair Ding Dong bell AC 230 volts single pole all as specified and as directed
S & F in repair Sub main wiring with two runs of single core 4 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 4 Sqmm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run through & including PVC conduit pipe concealed in walls /ceiling etc all as specified and as directed. (Note : Three run of 4sqmm cable and one run of PVC conduit altogether measured as one unit)
S & F in repair Sub main wiring with two runs of single core 6 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 6 Sqmm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run through & including PVC conduit pipe concealed in walls /ceiling etc all as specified and as directed. (Note : Three run of 6sqmm cable and one run of PVC conduit altogether measured as one unit)
M&L for Earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways , funnel with watering pipe wire mesh and lugs, test point including dismantling and taking down of old earthing complete all as specified and as directed.
Supply and fixing in repair building security light fitting LED 35 watt capacity 230Volts AC, outdoor type with high pressure die cast aluminium housing and heat resistant , with driver, lamp bracket with impact and corrosion resistent including thermal managment in multiple optic complete with IP-65/66 protection including 3 core PVC copper cable of 1.5 sqmm from ceiling rose to fittting all as specified and directed.
S & F in repair of Bracket made out of G I tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed.
Taking down ceiling fan, dismantling blades, cleaning, greasing and refixing back to original position, testing complete all as specified and directed.
S&F in repair Exhaust fan single phase 230/ 240 Volts AC of size 225 mm sweep with louvers fixed outside with all accessories and fixing from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm including core cutting for installation and making good to walls, etc all as directed.
S&F in repair Exhaust fans single phase 230/ 240 Volts AC of size 300 mm sweep with louvers fixed outside with all accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm including core cutting for installation and making good to walls, , etc all as directed.
S&F in repair LED Bulb 9 watt capacity suitable for indoor application to fit in Angle Holder or Decorative wall light fixture all as directed.
Taking down, dismantling of geysers of any type/capacity, replacment of geyser pipe,cleaning, descaling, re-assembling & re-installation on the original place including hydraulic pressure test of container with hand operated hydraulic pump complete, testing and commissioning complete all as directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, ther
mostate, NRV, connection piece etc. etc complete all as specified and directed at site .
S&F Wall mounting fan 400 mm Sweep with accessories, 230Volts, SP with BEE 3 Star rating complete with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed.
Supply and fixing in repair moulded FRP electric meter box suitable for 2 no of existing meter with IP 65 protection with 02 number of cable entry gland of standard size with suitable MS bracket to fix with pole complete all as specified and as directed.
Taking down carefully electric meter complete and refixing of the same meter in new meter box and making good the disturbed surface of walls, ceiling etc including painting with same colour of the back ground complete all as specified and as directed.
S& F in replacement Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20Amps capacity C curves complete all as specified and as directed.
S&F Ceiling fans with accessories, 230Volts, SP 1200 mm Sweep with BEE 3 Star rating and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed.
S&F TV Co-axial Socket for cable TV all as specifide and directed.
M&L for rigid non-metallic PVC conduit excluisive of box (junction/terminal) but inclusive of all tees, bends , elbowes , reducers, bell mouth tube end and fixing accessorise such as couplers, lock nuts, saddles, pipe hooks, pipe size of 20 mm etc (for carrying telephone wire/Data cable) all as specifide and as directed
Supply and spread dry sand in trenches as in cable cushioning all as per Para 19.75 of SSR part-I & all as directed. (Note: Punned thickness will be measured for payment.)
Supply and lay sub class 'B' old size bricks,desigbation 75 laid in trenches for protection of cables all as directed.
Supply and laying in repairs Galvanised iron steel tube 40 mm dia bore pipe light grade, with all fittings fixed complete on walls, poles, laid under floors or in trenches as cable protection works (including necessary clamps, bolts, nuts, etc.,) all as specifide and as directed
Supply & Laying in repairs XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm x 3.5 core laid in trenches/wall all as specifide and as directed
Supply& laying in repairs G I pipe 40mm dia, medium grade including accessories such as bends, Elbow, Tee, short length, Socket, Union, Nipples etc. laid in trenches or fixed on walls/ceiling/floor and testing all as specifide and as directed
Supply& laying in repairs G I pipe 25mm dia, medium grade including accessories such as bends, Elbow, Tee, short length, Socket, Union, Nipples etc. laid in trenches or fixed on walls/ceiling/floor and testing all as specifide and as directed
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
tender86482.pdf
Tender Documents • 1.49 MB
BOQ_830844.xls
BOQ • 2.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .