| 1 | L1₹46.6 LAccepted-AOC 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹48.3 L+₹70,775 (1.49%)Rejected-Finance SAPTARAG APARTMENT RAGHUNATHPUR RAA 35 V I P ROAD KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹48.6 L+₹94,209 (1.98%)Rejected-Finance VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹48.6 L+₹98,446 (2.07%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹49.3 L+₹1.7 L (3.60%)Rejected-Finance ROOM NO B 111 PART III GANESH MURTINAGAR CAPT PRAKASH PETHE MARG CUFFEPRADE CALABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
2 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
CERTAIN BR REPAIRS TO ELECTRIC SUPPLY INSTALLATION OF OUTSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2022_MES_562641_1
8940/E8
Open Tender
Civil Works
Item Rate
180 days
GE (FW) Kolkata
Ref as per tender documents
7 documents required · 7 mandatory
₹500
Ge (FW) Kolkata
₹86,000
23 Dec 2022
11 Nov 2022
3 Dec 2022
11 Nov 2022
2 Dec 2022
25 Nov 2022
Amount
SCHEDULE 'A' PART-I (B/R WORKS)
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 150 mm thickness (above or below ground level) including removal of debris & rubbish from site complete all as specified and directed.
Dismantling stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
Dismantling structural steel work of any description including doors, gates, railing etc but excluding framed trusses complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for, complete all as specified and directed.
Dismantling single layer mangalore pattern or similar tiles as in roofing, complete all as specified and directed.
Dismantling timber in fillets, rails, posts, rafters, purlins etc., under 40 Sqcm in section, complete all as specified and directed.
Dismantling of posts or struts (wood, steel or RCC) any description in any sections including taking out embedded portion and making good disturbed ground post embedded in concrete, complete all as specified and directed.
Dismantling of fencing, wire mesh any type incl flat iron fillet, nuts & bolts, MS round bar etc complete all as specified and as directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Excavation in post holes each not exc 0.5 Cum getting out returning filling in and removing earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance not exc 50m and making good surface as in soft / loose soils, complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated materials not exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as Specified and as directed.
M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregates as in foundation filling, fixing of post holes, support to flag pipe and mass concrete complete all as specified and directed.
M&L for PCC (1:5:10) type E-2, by using 40 mm graded stone aggregate as in foundations, fillings and mass-concrete, complete all as specified and directed.
M&L for cutting holes in brick wall exceeding half brick but not exc one brick thick walls for inserting hold fasts for mild steel grills and making good dismantled portion in cement concrete 1:2:4 type B1 (using 20 mm graded aggregates) including necessary formwork and making good surfaces as per existing finishes complete all as specified and directed.
M&L Brick Work with fly-ash Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M & L half brick with sub class 'B' fly-ash bricks straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed.
M&L for dubbing out cement plaster (1:4), average 10 mm thick on irregular faces of walls (when specially ordered in writing) complete all as a specified and as directed
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces of walls in cement mortar 1:6 finished rendering surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick built in cement mortar (1:4) on fair faces of brick work or concrete surfaces of walls finished even & smooth (without using extra cement), complete all as specified and directed.
M&L for rendering 15 mm thick built in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even & smooth (without using extra cement) and mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE : Water proofing compound shall be measured and paid separately).
M&L for 5mm thick rendering on fair faces of brick work or concrete surfaces of ceilings in cement mortar 1:3 finished rendering surfaces even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound of Make.Pidilite or equivalent, all as specified and as directed.
M&L 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, finished even and smooth without using extra cement as directed by the Engr-in-Charge.
M&L for 100 mm thick plain cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) as in surface channels, floors, hardstanding etc, finished even and fair complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 using 20 mm graded aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones , bed plates, kerbs, water troughs and the like includinguding weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed.
M&L for 50mm Cement concrete type B-1, 1:2:4 (20mm graded aggregate) finishing cement concrete surface even and smooth complete all as specified and directed.
M&L for Sand filling under floors or in foundations, including watering and consolidation, complete all as specified and directed.
M&L for machine cut pre polished kota stone slab flooring 18-20 mm thick, laid over and including 15mm thick screed bed in cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
M&L for laying and fixing Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick cement screed in cement mortar 1:4 and jointed etc complete all as specified and directed.
M & L for pre-polished glazed Chequered cement concrete tiles (coloured) of size 30cmx30cmx25mm thick , set , jointed and pointed in neat cement slurry in floor and pointed with white/coloured cement & pigment to match the surface laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Supply and fixing Rolled mild steel in joist, channel, angle, or tee section fixed independently, upto a height of 6 metre from each floor level (cut to ordinary length i.e. within 20mm of the length indicated) of FE-410- W(Gde-E-250) quality-A as in fencing posts, including drilling holes for nuts and bolts and similar works, complete all as specified and as directed.
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe-410-W (Gde-E 250) quality-B complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
All as per item No.1.35 above, but using old serviceable iron members including necessary cutting to size, welding etc
Supply and fixing mild steel wind ties for roof including securing bolts, posts including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets, including all necessary drilling, bolting or rivetting etc., and similar works confirming to Fe 290 Gde E-165, complete all as specified. NOTE: Measurement shall be taken for the MS flat only. Quoted rate is deemed to include for the cost of securing bolts etc.,
M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed.
Fixing only RCC post or angle iron post (obtained from dismantling here in before), complete all specified and directed.
Fixing only RCC post or angle iron post (obtained from dismantling here in before), complete all specified and directed.
S & F MS 10 mm dia round bar and fixed independently to angle iron for chain link fencing cut to length, bend to shape required, complete all as specified and as directed
S&F in repairs galvanized 2 strand steel barbed wire fencing conforming to IS : 278, with 2.24 mm dia. barb wire conforming to IS : 280 with zinc coating as per IS : 4826, barbed with 2 mm dia. barbs at 75 mm spacing and straining and fixing to any type of standard rails/RCC fencing posts straining bolts, including securing or tying at crossing with and fixing of galvanized mild steel wire, staples or steel pins etc., incl dismantling of existing barbed wires complete all as specified and directed. (Note: - Each line of wire will be measured)
S&F 4 mm dia PVC coated galvanised mild steel chain link fencing of mesh size 50 x 50 mm fixed with straining bolts including line wire any mesh size and type to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified and as directed. NOTE: MS post, MS round bars, flat iron, nuts & bolts shall be measured and paid separately.
Re-fixing only chain link fencing of any mesh size fixed with new straining bolts including line wire any mesh size and type to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified and as directed. NOTE: MS post, MS round bars, flat iron, nuts & bolts shall be measured and paid separately.
Supply and laying 450 mm bore reinforced concrete hume pipe of Class NP-2, laid and jointed with jute & cement mortar 1:2, complete with collars all specified and as directed.
M&L concrete bed to drain pipe including packing under and haunching against the side of drain pipe after laid and tested in PCC 1:3:6 type C2 for 450 mm bore pipes complete all as specified and directed.
S&F Factory made solid PVC door frame (chowkhat) of size 50 mm x 47mm made out of 5mm plain colour wood grain printed PVC sheet used instead of plain colour PVC sheet and edges will be painted to match with printed sheet reinforced with MS square tube of size 40mm x 20mm of 19 guage throughout the frame, fixed in opening as per specification & drg as per manufacturer instructions complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per manufacturer's specification complete all as specified and directed.
M&L for powder poated anodized aluminum frame for doors, windows, ventilators and partition with one or more rebate including joining cleat for fixing etc, as in repairs, complete all as specified and directed..
M&L for powder coated anodised aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinges types B-21 100 mm long (2No) suitable handle (1No) complete all as specified. (NOTE: Glass shall be measured and paid separately)
Supply and fixing 5.50 mm thick sheet glass frosted on one side, area in squares not exc 0.5 sqm in each pane and glazing with rubber gasket fixed to aluminium frame work / snap beading complete all as specified and as directed.
S&F in repair powder coated aluminium wndow grill of size 100 mm X 100 mm having section width 6 mm and 3 mm thickness, fixed on aluminium section weighing not less than 0.55 kg/sqm including necessary jointing, fitting etc all as per manufacturer's instruction complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples, as in repairs, complete all as specified and directed.
Hacking out old broken glass (any thickness and size or quality) from wooden frames glazed with putty or fixed with beads complete all as specified and directed.
Supply & fixing 75 mm mild steel butt hinges(medium weight) cold rolled complete all as specified and directed.
Supply & fixing 100 mm mild steel butt hinges(medium weight) cold rolled complete all as specified and directed.
S&F aluminium handle, cast type anodised 150 mm size complete all as specified and directed.
S&F 200 mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150 mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 300 mm aluminium, anodised sliding door bolt with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
S&F Non Skid joint free coloured tiles 7-8mm thick area of each tiles exc 0.11Sqm but n. exc 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and incl 15mm thick screed bedding in cement mortar 1:6 complete all as a specified and as directed
S&F coloured glazed ceramic tiles in vertical surfaces 450 X 300 X 7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match, fixed over and incl 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris complete all as specified and as directed.
M&L for Providing Cement Concrete, type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding, of thickness as required on site, for making good depression/undulation, roof kerb etc, finished even and fair complete all as directed.
M&L 10 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.10 litre per sqm over APP membrane.
S&F in repair Chromium plated brass Pillar tap, fancy type. with aerator, fixed to wash hand basin, complete all as specified and directed. (Make : Ess Ess, Cat No: C-201B / JAQUAR, Cat No: CON-021KN/ PARRYWARE, Cat No: G1402A1 / PRAYAG, Cat No: 9204/ HINDWARE, Cat No: F330002CP / Cera, Model: OCEAN)
S&F in repair Chromium plated brass Bib cock with wall flange, fancy type, long body, fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : Ess Ess, Cat No: C-209 / JAQUAR, Cat No: CON-107KN/ PARRYWARE, Cat No: G1405A1 / CERA, Model : OCEAN / PRAYAG, Cat No: 9208 /HINDWARE, Cat No: F330041)
S&F in repair, 15 mm bore fancy type stop valves, cast copper alloy, chromium plated (concealed type), screwed down, high pressure, with crutch or butterfly handle, incl concealed body, screwed both ends for iron pipe or for unions and, complete all as specified and directed. (MAKE : JAQUAR, Cat No: CON-083FTK / PARRYWARE, Cat No : G1461A1 / ESS ESS, Cat No: T-108 / CERA, Model: OCEAN / PRAYAG, cat No: 9218/ HINDWARE, Cat No: F330052)
S&F in repair Chromium plated brass Angular stop cock, fancy type, concealed type with wall flange fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: CON-59KN / PARRYWARE, Cat No: G1453A1 / ESS ESS, Cat No: C-206 / CERA, Model: OCEAN / PRAYAG, Cat No: 9210 / HINDWARE, Cat No: F330043)
S&F stainless steel flat slotted grating with frame, fixed with white cement complete all as directed. (Make : PRAYAG, Cat No : FT-70 or equivalent make as approved by GE)
Supply and fix in repairs Low density polyethylene pipe connection, comprising of 15 mm dia 450 mm long having PTMT union at each end of connection to each of pillar tap/cistern/stop cock/urinal etc. at one end, stop cock at other end complete all as specified and directed. (MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 or equivalent model in SHAKTI / JEXON)
S&F 32 mm bore PVC corrugated waste pipe, 800 mm long for wash hand basins complete all as specified and directed. (Make: PRAYAG, Cat No: 327 or equivalent make as approved by GE)
S&F in repair White PVC Flushing Cistern 10 Litre capacity, Low Level Valve Less, Symphonic Action type with Inlet, Ball Valve, Float, flush pipe and Handle including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 and fixed including taking down/out unserviceable Flushing Cistern and connected items complete all as specified and directed. (MAKE : PARRYWARE, Model : Slim line Economy / HINDWARE, Model : Sleek Plus / CERA, Model : Corona / PRAYAG, Model: SMART or equivalent model in COMMANDER )
Taking up or down steel water tubing 15 mm bore incl connection , cleaning etc
All as per item No.1.77 here-in-before but 20 mm bore
All as per item No.1.77 here-in-before but 25 mm bore
S&F tubes 15mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
All as per item No.1.80 here-in-before but 20 mm bore
All as per item No.1.80 here-in-before but 25 mm bore
Supply, hoisting and fixing rotational moulded polyethylene water storage tank (cylindrical vertical type with closed top) of capacity 500 Litres, multi-layered (ISI marked), with GI tank nipple & cover, hoisted and fixed in position all as specified in SSR Part-I incl dismantling of existing unsv tank complete all as specified and directed.
S&F 20 mm bore Ball brass valves, high pressure, with HDPE float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. (MAKE : PRAYAG, Cat No. B-152 or equivalent model in JEXON / POLYTUF / SHAKTI)
S & F of vitreous China wash basin, white, flat back, size 550x450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets, with 32mm dia Brass Chromium Plated Waste Fitting complete all as specified and directed. (MAKE : PARRYWARE, Cat No. C0406 / HINDWARE, Cat No. 10010 / JAQUAR, Cat No. CNS-WHT-801 / CERA, Cat No: S2040141)
Supply and Fix vitreous China Squatting pan ‘Orissa’ pattern, size 580 X 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, etc and including making good to floor, complete all as specified and directed. (MAKE : PARRYWARE, Cat No. C0117 / HINDWARE, Cat No. 20004 / JAQUAR, Cat No. CNS-WHT-OP01 or equivalent model in CERA)
M&L for preparation of surfaces and applying two coats of cement base paint over a coat of alkali resistant primer on new plastered surfaces complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting of any gauge, thickness,including roof coverings, complete all as directed.
Dismantling AC corrugated roof sheets as in roof coverings including AC ridge complete all as directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
All as per Item No.1.90 above, but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
Supply and fix wind driven turbine ventilator (mill finish) powder coated hurricane 600 with FRP base to match roof sheeting and variable angle elbow with and including flashing sheet fixed with self tapping screws, complete all as specified and directed.
Supply and fix 0.80 mm thick plain galvanised mild steel sheeting, as in hips, valley gutter, drip and straight flashings ( length and girth as fixed) for hangers etc., as in repairs, complete all as specified and directed.
Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Complete removal of existing treatment including preparation of old treated surfaces of walls and applying two coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying 1 mm thick wall putty over plastered surfaces, finishing surfaces even and smoooth and applying two coats of acrylic distemper finished with roller over a coat of alkali resistant primer as per manufacturer's instructions complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and soffit of chajja, roof slab etc., by cleaning brooming, rubbing and scrapping as required using broom, emery paper, putty blades/scrapper as applicable to make the surface free from protrutions, loose particles, dust etc., including necessary safety & protective measures such as safety belt, headgear etc., finishing the surfaces with 2mm thick exterior wallcare putty (in two layers) for smooth finish and applying two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer of approved make by using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 Story building height, complete all as specified and directed by Engineer -in-Charge.
M&L for complete removal of existing treated surfaces of walls and soffit of chajja, roof slab etc., by cleaning brooming, rubbing and scrapping as required using broom, emery paper, putty blades/scrapper as applicable to make the surface free from protrutions, loose particles, dust etc., including necessary safety & protective measures such as safety belt, headgear etc., finishing the surfaces with 2mm thick exterior wallcare putty (in two layers) for smooth finish and applying two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer of approved make by using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 Story building height, complete all as specified and directed by Engineer -in-Charge.
M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed.
M & L for applying two coats of Synthetic Enamel Paint (First quality) over a coat of red oxide primer on steel surfaces not exc 10 cm width or girth including preparation of surfaces complete all as specified and as directed.
M&L for preparation of old painted steel surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
All as per item No 2.02 above, but on wooden surfaces.
Supply and fixing 110mm bore PVC (SWR) pipes, single socketed, in any length, with rubber ring joints, fixed to wall all as specified and as directed by the Engineer-in-Charge.
Supply and Fixing 110 mm PVC (SWR) Bend any radius complete all as specified and as directed by the Engineer-in-charge.
S&F stack clamps made out of 50 x 5mm Flat iron and 16mm dia round iron stay, including bolts and nuts and securing ends of stays to wall or roof of 110mm dia PVC (SWR) pipes, complete all as specified and as directed by the Engineer-in-charge.
SCHEDULE 'A' PART-II (ELECTRIFICATION WORKS)
Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets, light fitting etc for reuse or removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
M&L for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.
All as per item No. 3.04 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 3.04 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No.3.04 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box).
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amps flush type universal complete all as specified and directed.
S&F socket outlet 6/16 Amps, 6 in 1, flush type complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/bakelite, three terminals complete all as specified and directed.
S&F electronic type stepped speed regulator, 100 watts, AC 230 Volts for ceiling fan, complete all as specified and directed.
S&F in repairs surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
All as per Item No. 3.15 above, but of 1 X 16 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
S&F LED Bldg Security Light fitting 30 W, in pressure die cast aluminium housing with PMMA lens and toughened glass/PC cover having TOP opening seperate driver compartmnent, with integrated constant current electronic driver, incl providing new GI pipe bracket as per existing size including necessary electrical connection with stuiable size copper wire complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 110 lumen/watt (b) CRI not less than 70, (c) THD < 30% (c) having in built short circuit & surge protection upto 5 kV (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection grade: IP66
M&L for sub main wiring with 2 runs of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 Sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 Sqmm as earth continuity conductor drawn through and including PVC casing capping, medium grade of suitable size, complete all as specified and directed. (NOTE : Three runs of single core 6.0 Sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 127 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 Sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 127 above but with two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 2.5 Sqmm cable & one run of PVC casing capping shall be measured as one unit)
Cutting chases pinning in, not exc 15 cm girth for concealed point wiring and making good the disturbed surfaces in CM 1:4, complete all as specified and directed.
S&F TPN DB, IP 43 protection, double door (premium quality), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T, Cat No. DBTPN004DD / LEGRAND, Cat No: 507670 / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4 / PANASONIC, Cat No: BQS 304H / HAGER, Cat No: VYT04DH)
S&F, Double Door, Sheet Metal Enclosure for DBs (Premium Quality), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN008DD / LEGRAND, Cat No: 507611 /ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08 / HAGER, Cat No: VYS08D)
S&F MCB (premium quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (premium quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCCB (premium range), 4 pole, 100 Amps, 16 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed. (MAKE : L&T, Cat No: CM90518OOKO / LEGRAND, Cat No: 420015 / HAGER, Cat No: HDA101U or equivalent model in SCHNEIDER, Cat No: LV426167 /ABB, Cat No: 1SDA066818R1)
S&F in repairs LED Highbay luminaire 150 Watts, circular shape, of various capacity as mentioned under, in high pressure die cast aluminium/LM6 alloy housing with secondary modular lens optics and toughened glass cover with integrated constant current electronic driver, IP66 ingress protection complete all as specified and directed and complying with the following specifications:-. (b) CRI not less than 80, (c) THD < 10% (d) Power factor not less than 0.90 (e) having in built short circuit and surge protection upto 5 kV (f) colour temperature not less than 5700 degree K (g) life not less than 50000 hours of operation NOTE:- (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Wire for electric connection shall be measured and paid separately)
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
B & R CONSTRUCTION
M/s Santosh Industrial Corporation
PEARL CORPORATION
M/S SRINIVASA CONSTRUCTION
MODERN AGENCY
DEYS ENTERPRISE
MS AP CONSTRUTION AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .