| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.2 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹26.4 L+₹1.5 L (5.99%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹26.5 L+₹1.7 L (6.77%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹29.8 L+₹4.9 L (19.8%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹30.7 L+₹5.8 L (23.4%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L-5 | Rejected-Finance L-5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
13 Sept 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/MAINT OF LT SWITCH GEAR, MCCBS, ACBS, ACS, DG SET, AMF PANEL AND CLEANING/MAINT OF OHT RESERVOIR, UG SUMPS, RISING MAIN AND OTHER E/M INSTALLATION AT DIFFERENT LOCATIONS AT AASTHA MESS, 5 AFLU AND MCC BASANT NAGAR UNDER AOR OF GE (AF) FBD
2024_MES_667093_1
GE (FBD)/AF-27/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Delhi Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹96,000
Yes
10 Dec 2024
20 Jul 2024
19 Sept 2024
20 Jul 2024
13 Sept 2024
3 Aug 2024
20 Jul 2024 - 27 Jul 2024
Amount
Maintenance/repair to 320 KVA Gen set installed at sub station by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant complete all as specified and directed by Engineer-in-Charge. Note :-(i) Parts required for replacement will be measured and paid separately under respective item of BOQ. (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected SPARE PARTS FOR DG SET
Supply only Element lub oil filter Cartrige complete all as specified and directed by Engineer-in-Charge.
Supply only fuel filtter Cartage complete all as specified and directed by Engineer-in-Charge.
Supply only Pre Filter Assembly complete all as specified and directed by Engineer-in-Charge.
Supply only seal 'O' ring complete all as specified and directed by Engineer-in-Charge.
Supply only KOEL Care genuine oil complete all as specified and directed by Engineer-in-Charge.
Supply only K-COOL super plus Coolent complete all as specified and directed by Engineer-in-Charge.
Supply only Air Filter for 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only distilled water complete all as specified and directed by Engineer-in-Charge.
Supply only Battery terminals complete all as specified and directed by Engineer-in-Charge.
Maintenance/repair to 50/ 75 / 80 KVA Gen set " Greevs" installed at sub station in Basant Nagar Officer's Mess by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant complete all as specified and directed by Engineer-in-Charge. Note :- (i) Parts required for replacement will be measured and paid separately under respective item of BOQ (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected SPARE PARTS FOR DG SET
Supply only Pre Filter Assembly complete all as specified and directed by Engineer-in-Charge.
Supply only seal 'O' ring complete all as specified and directed by Engineer-in-Charge.
Supply only genuine Engine oil complete all as specified and directed by Engineer-in-Charge.
Supply only Coolent complete all as specified and directed by Engineer-in-Charge.
Supply only Air Filter for 75 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only distilled water complete all as specified and directed by Engineer-in-Charge.
M&L in repair of PCB suitable for 250/320 KVA DG set AMF panel complete all as specified and directed by Engineer-in-Charge.
M&L in repair of AVR Unit of 250/320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
M&L in Repair of Self starter of 250/320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of fuel pipe of DG set connecting from inlet of the tank to dg set complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of V belt for radiator fan suitable for 320 KVA DG set as per sample complete all as specified and directed by Engineer-in-Charge.
M&L for repair/replacement of battery 12 volts, 180 amh complete all as specified and directed by Engineer-in-Charge.
M&L for complete oherhauling of Engine incl opening of engine head of 250 / 320 KVA DG Set carefully and Servicing of internal parts of engine, piston, lining etc and entire assembly and fixing the parts after opening complete all as specified and directed by Engineer-in-Charge. Note :- Spare part are paid separately.
M&L for replacement of the following unserviceable parts of 320 KVA DG set as per the existing Kirloskar model of the DG set:-
Piston
Ring set
Piston pin
CR Bearing
Head valve
Head Gas kit
Head seal
Packing kit of the engine
S&F in replacement of water pump suitable for 250/ 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of engine lining after complete opening of engine of 250/ 320 KVA DG Set including topup of engine oil complete all as specified and directed by Engineer-in-Charge.
M&L in Repair of fuel nozzeles of 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
M&L in repair of turbocharger of 320 KVA DG SET complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Battery charger 24 V DC with digital display complete all as specified and directed by Engineer-in-Charge.
Preventive Maintenance/repair M0/M1 or M2 62.5 KVA Gen set installed at sub station by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant all as required and complete all as specified and directed by Engineer-in-Charge. Note :-(i) Parts required for replacement will be measured and paid separately under respective item of BOQ (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected SPARE PARTS FOR DG SET
Supply only Element lub oil filter Cartrige complete all as specified and directed by Engineer-in-Charge.
Supply only fuel filtter Cartage complete all as specified and directed by Engineer-in-Charge.
Supply only Pre Filter Assembly complete all as specified and directed by Engineer-in-Charge.
Supply only seal 'O' ring complete all as specified and directed by Engineer-in-Charge.
Supply only KOEL Care genuine oil complete all as specified and directed by Engineer-in-Charge.
Supply only K-COOL super plus Coolent complete all as specified and directed by Engineer-in-Charge.
Supply only Air Filter for 250 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only distilled water complete all as specified and directed by Engineer-in-Charge.
Supply only Battery terminals complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of the following unserviceable parts of 62.5 KVA DG set as per the existing Kirloskar model of the DG set:-
Piston
Ring set
Piston pin
CR Bearing
Head valve
Head Gas kit
Head seal
M&L in repair of fuel nozzeles of 62.5 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
M&L in repair of turbocharger of 62.5 KVA DG SET complete all as specified and directed by Engineer-in-Charge.
M&L for Design, development, supply commissioning and testing EHCC certified ground tubular effective chemical earthing system (CPRI tested for 15 KA current capacity for LT Iine) highly anticorrosive long life electrode with and including adequate protective coating to withstand servere weather conditions in the earth pit of the standard size comprising of 40mm x 3m Long Copper rod as primary conductor and hollow copper tube of 80mm x 3m long as secondary conductor to install with suitable connecting terminal confirming of IS 3043 : 1987 specification, highly conductive packing material to be filled in earth pits for providing uniform, low resistivity anticorrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation with crystalline conductive mixture (CCM) 20 Kg per bag (3 bag per kit) minimum or sufficient quanitities required as per site complete including RCC earthing pit cover , material and labour complete all as specified and directed by Engineer-in-Charge. Note :- Excavation / drilling hole in hard soil/rock is included in the rate quoted.
M & L for earthing with steel earth plate electrode of size 60 x 60 cm x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earht plate, 40mm dia GI tubing lightgrade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made outof steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and complete all as specified and directed by Engineer-in-Charge.
M&L earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge.
Supply and fixing contactor 100 Amp 3 pole for time switch astro type/Nature switch fitted inside box complete with all electrical connection after dismantling old one complete all as specified and directed by Engineer-in-Charge.
Supply and fixing contactor 63 Amp 3 pole for time switch astro type/Nature switch fitted inside box complete with all electrical connection after dismantling old one complete all as specified and directed by Engineer-in-Charge.
Suply and fix in replacement of Sheet metal enclosure for MCCB 3P, one no complete all as specified and directed by Engineer-in-Charge.
S&F in repair wall mounted TPN busbar chamber factory made with busbar of current rating 400 Amp, 415, 4 way complete all as specified and directed by Engineer-in-Charge.
S&F in replacement TPN DB-VTPN DBs 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar WITH INCOMER AS 4 POLE MCB upto 64 amps 240/430V for fixing of MCBs/Isolators/MCCBs etc completed after dismantling old one complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCB SP 6 to 32 amps 230 Volt complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repair,MCCB 400 Amp ,3 pole, adjustable type ,36 KA including under voltage/over voltage relay complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repair,MCCB 250 Amp ,3 pole, adjustable type ,25KA including under voltage/over voltage relay complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Adjustable type MCCB 400 Amps ,4 Pole ,36 KA ,50 Hz ,415 Volt including under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Adjustable type MCCB 315 Amps ,4 Pole ,36 KA ,50 Hz ,415 Volt including under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Adjustable type MCCB 250 Amps ,4 Pole ,25 KA ,50 Hz ,415 Volt including under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Adjustable type MCCB 200 Amps ,4 Pole ,25 KA ,50 Hz ,415 Volt including under voltage/over voltage relay,adjustable overload setting and short circuit setting all as specified and directed. complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCCB 100 Amps 4 pole 25 KA 415 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Adjustable type MCCB 125 Amps ,4 Pole ,25 KA ,50 Hz ,415 Volt including under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Adjustable type MCCB 63 Amps ,4 Pole ,16 KA ,50 Hz ,415 Volt including under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Onload Changeover switch 630 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Onload Changeover switch 400 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as specified and directed by Engineer-in-Charge.
M& L for welding each canopy door to the outer unit for proper closing and opening including hinges and repainting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement post top latern LED 40W or next higher wattage having IP65 protection for single phase connection 50Hz 240 Volts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old u/s LED flood light luminarie 70 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old u/s LED flood light luminarie 120 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 16 to 35 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 150 to 185 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 300 to 400 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Taking down old unsv LT cable any type size / type complete all as specified and directed by Engineer-in-Charge.
Laying only LT cables in treches , connecting and testing of cables of following sizes complete all as specified and directed by Engineer-in- Charge:- Note : (i) LT cable will be issued under Sch 'B'. (ii) Earth works shall be measured & paid seprately under relevent items
All as per item No 90 above but Cable of size 95 sqmm 3.5 core.
All as per item No 90 above but Cable of size 25 sqmm 3.5 core.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core including taking out old unsv LT cable complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core including taking out old unsv LT cable complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core including taking out old unsv LT cable complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core including taking out old unsv LT cable complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core including taking out old unsv LT cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sq. mm 3.5 core including taking out old unsv LT cable complete complete all as specified and directed by Engineer-in-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 sq. mm 3.5 core including taking out old unsv LT cable complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 630 sq mm 3.5 core including taking out old unsv LT cable complete all as specified and directed by Engineer-in-Charge.
Labour only for detecting the fault in existing LT Cable by meggering or any other suitable method. Taking out defective cables from trenches, wall, pole , Pipe, PCC, under ground, etc exsisting cable LT 1100 volt grade heavy duty , armoured with steel strip of wire , with stranded aluminium conductor of any size, any core, for seggregation of serviceable cable length ,unserviceable cable length and unuse cable length including disconnection and re-connection of Cables. Removing unserviceable cable from site and serviceable cable shall be reused at same or any other location including testing complete all as specified and directed by Engineer-in-Charge. Note : Earth work shall be measured and paid separately under respective item.
Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engineer-in-Charge.
M & L for brick protection with sub class 'B' bricks laid dry flat over electric cable in trenches complete all as specified and directed by Engineer-in-Charge.
M & Labour for sand cushioning with a layer of sand 80mm thick consolidated before laying of cable and 150mm thick consolidated after laying of cable in trenches ducts for electric cable protection including consolidation complete all as specified and directed by Engineer-in-Charge.
M & L cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate for LT panel, pole pedestal (PCC) including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Labour only for rectification of fault in AMF panel of DG set and testing on load ranging from 80 to 320KVA complete all as specified and directed by Engineer-in-Charge.
Labour only for rectification of fault in AMF panel of DG set and testing on load ranging from 50 to 250 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of relay of AMF panel complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of display panel of AMF suitable for DG set rating 50 to 62.5 KVA along with all connections and push buttons for mode change and start stop button complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of display panel of AMF suitable for DG set rating 80 to 320 KVA along with all connections and push buttons for mode change and start stop button complete all as specified and directed by Engineer-in-Charge.
S & F rubber insulation mat of size 1.8 mtr x0.9mtr wide 2mm thick green / blue colour ISI marked embozzed for up to 3.3 KV complete all as specified and directed by Engineer-in-Charge.
M& L for maintenance, servicing and testing of AMF panel suitable for 320 KVA DG set by cleaning and tightening of all the connections, cleaing of all links of circuit breakers using CRC and testing of breakers for smooth operations including vaccum cleaning / blower cleaning of the entire panel from the inside complete all as specified and directed by Engineer-in-Charge.
M & L for Repair and Maintenance of split type AC's of capacity 1.5/2 TR comprising of the following tasks installed at different locations including testing complete all as specified and directed by Engineer-in-Charge. Note : (a) Inspecting and checking the Indoor/outdoor units for noise free operation (b) Checking the electrical connection for tightness (c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower.(d) Greasing/Oiling of condenser fan motor and blower motor. (e)Checking for any refrigerant leakage. (f) Checking for serviceability of remote control unit.
Supply and fixing in replacement of starting capacitor 80-100/100-120 mfd for split type A/C's of capacity 2 TR complete all as specified and directed by Engineer-in-Charge.
S/F in replacement of running capacitor 30/36 mfd for split type AC unit as required at Site and complete all as specified and directed by Engineer-in-Charge.
M & L for Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new rotary/reciprocating type compressor with charging of refrigerent (R410A,R32,R134A)after dehydration testing and vaccumming one as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge.
M & L for Disconnecting and taking down burnt compressor of capacity 1.5 TR with CFC free Refrigerent (R410a,R32) from split type AC unit and Supply and Fix new rotary/reciprocating type compressor with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
M&L for repair to gas leakage of split type AC unit of capacity 1.5/2TR capacity including pressure testing, dehydration and gas charging complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable PCB from 1.5 /2 TR split type A/C unit and refixing the serviceable PCB after repair from workshop complete testing complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable PCB from 1.5 /2 TR inverter split type A/C unit and refixing the serviceable PCB after repair from workshop complete testing complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of unserviceable inverter type PCB from the existing inverter split type A/C unit 1.5/2.0 Ton complete of existing make ,testing complete all as specified and directed by Engineer-in-Charge.
Supply and charging Refrigerant(R410,R32,R134 and existing refrigerent) to any type of AC unit including CFC free and non CFC Free AC complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of copper tubing 10mm outer dia suitable for AC 2TR capacity complete all as specified and directed by Engineer-in-Charge.
M&L in replacement copper tubing 15mm outer dia complete all as specified and directed by Engineer-in-Charge.
M & L for Dismantling of Split type AC 1.5/2.0 TR capacity from position after including disconnecting all connections between indoor and out door units,shifting,backup refrigerant for reuse and install at a place where directed carefully,including cutting on wall,making hole and make good disturbed surface properly matching surface,inspecting,servicing and refilling refrigerant and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement copper condensor coil for split AC 2 TR complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement copper condensor coil for split AC 1.5 TR complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement copper evaporater coil for split AC 2 TR complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement copper evaporater coil for split AC 1.5 TR complete all as specified and directed by Engineer-in-Charge.
M & L for Taking out burnt condenser fan motor and rewinding of condenser fan motor of split type AC units of capacity 1.5/2 TR including replacement of worn out bush and bearing complete all as specified and directed by Engineer-in-Charge.
M & L for Taking out burnt blower motor and rewinding of blower motor of split type AC units of capacity1.5/ 2 TR including replacement of worn out bush and bearing complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of electronic remote control unit of split type A/C unit (cordless type) 1.5/2.0 Ton complete of existing make complete all as specified and directed by Engineer-in-Charge.
Material and Labour for providing insulation 9mm thick for dia 1/4",3/8",1/2",5/8",6/8" copper tubing’s from Indoor to outdoor units with foam insulation followed with clamps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair PVC insulated Sheathed, Copper conductor,6 sq mm ,3 core (flexible) cable,1100 Volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair PVC insulated Sheathed, Copper conductor,4 sq mm ,3 core (flexible) cable,1100 Volts complete all as specified and directed by Engineer-in-Charge.
M & L for Repair & maintenance of water coolers/Refg of capacity 40/80/150/180 Ltrs comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. Note: (a) Inspection, taking down, opening, dismantling, decaling, brushing cleaning of storage tanks (b) Examination water tightness, leak proof of storage tank after cleaning.(c) Carry out operation of all stop cock, push cock, float valve etc. (d) Inspect overflow and remove blockage if any. (e) Check and correct earth continuity of electric items (f) Check thermostat and test its functioning (g) Inspect drain pipe and remove blockage if any (h) Check and correct all electrical wiring & test its functioning (i) Testing of water cooler after repair
Supply & fixing in replacement of thermostat switch suitable for water cooler/Refg as required at site complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of starting relay as required at site for water coolers/Refg Ltrs capacity complete including connecting, testing complete all as specified and directed by Engineer-in-Charge.
M & L for Disconnecting & taking out compressor ('R type) from water cooler/Refg for any capacity and supply and fix the new compressor including flushing dehydration and gas charging complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20-32 amps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement plug top 15 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of 3 pin socket metalic plug top industrial type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair outdoor unit fan blade for 2.0/1.5 TR split AC complete all as specified and directed by Engineer-in-Charge.
Supply and install wall mounted stand for mounting indoor unit of split AC complete with all fixing arrangement complete all as specified and directed by Engineer-in-Charge.
Supply and install wall mounted stand for mounting outdoor unit of split AC complete with all fixing arrangement complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and directed by Engineer-in-Charge.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 6 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length
Supply and fix FRESH AIR fan sweep 300 mm in replacement made up of sturdy engineering plastic complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair BLDC fan Energy Efficicent ceiling fan Sweep size 1200mm with speed 350 RPM motor air delivery 220 CMM input power 28W-32W and having remote control all as specified and as directed.note:- OLD fan need to deposit in store no credit will be provided for the same complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacanemt of old unsv voltage regulator/stbz and fix new elctronic volatage stablizer for AC upto 2.0 TR having working voltage 170-260V included intelligent time delay system,high voltage cut-off protection,bulit in thermal overload protection with wall mounted cabinet design complete all as specified and directed by Engineer-in-Charge.
M&L for Dehydration including filteration and cleaning of transformer oil by centifugal dehydration machine till to achieve Di-electric strength 55 KV at 2.5 mm gap testing of sample before and after dehydration and filteration complete all as specified and directed by Engineer-in-Charge. NOTE:- Contractor has to arrange the dehydration machine and testing kit without any extra cost to the deptt. Test report to be submitted after completion of job.
Supply & Filling /pouring of transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and directed by Engineer-in-Charge. NOTE:- Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site.
M&L danger notice board/plate of 1.6mm thick mild steel sheet vitreous enameled white with letter, figures and conventional skull and bones in signal red colour and fixed with MS clamps, nuts and bolts of approved size of HT 25 x 20 cm size complete all as specified and directed by Engineer-in-Charge.
Supply only chlorine test kit with PH colured sample complete with all testing fitment and OT solution in rexine box complete all as specified and directed by Engineer-in-Charge.
M&L for chemical and bacteriological analysis of Raw water collected from all the pump house complete all as specified and directed by Engineer-in-Charge.
M&L for chemical and bacteriological analysis of chlorinated water collected from distribution line complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of electric motor 1 HP to 1.5 HP HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair/replacement of 1HP pressure booster pump as per existing make with head of 10 -50 meters complete all as specified and directed by Engineer-in-Charge as per ground requirement
Supply and fix in repairs Decrin dozing pump 100 PSI 40 GPD Capacity and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of circuit of speed of Dozing pump complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of injector Nozzle of Decrin dozing pump complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Regulator Knob of dozing pump complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of power cord of dozing pump 2 mtr long plug top 5 AMP 240 volt AC complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 50 to 110 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 40 to 45 complete all as specified and directed by Engineer-in-Charge.
Supply and install and commmissionng of LT bus bar chamber CPRI approved out door type with sloping canopy of size 600x600x600mm made out of 3.15 mm thick CRCA sheet, panel shall be powder coated siemens grey shade mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4:8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200 mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps,3 pole ,415 mps, 50 Hz of breaking capacity 25 KA as incomer complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement amp meter digital type as per existing size and type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement volt meter digital type as per existing size and type complete all as specified and directed by Engineer-in-Charge.
S&F in repair CT 30/5 to 200/5 complete all as specified and directed by Engineer-in-Charge.
S&F in repair indicating light with bulb set of three complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of DOL starter for 10 HP with complete protection and complete all as specified and directed by Engineer-in-Charge.
S & F Volt Meter 0 to 500 Volts digital square type 4” complete all as specified and directed by Engineer-in-Charge.
S & F Ammeter 0 to 200 Amps digital Square type 4” complete all as specified and directed by Engineer-in-Charge.
S & F Indicating Lamp set of three (Red , Yellow & Blue) complete all as specified and directed by Engineer-in-Charge.
Taking up or down following sizes GI Pipe and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
All as per item No 184 above but 50 mm bore
All as per item No 184 above but 40 mm bore
All as per item No 184 above but 25 mm bore
All as per item No 184 above but 20 mm bore
Supply and fixing in replacement of unserviceable GI tubing medium grade with all fittings complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc including taking down complete all as specified and directed by Engineer-in-Charge.
All as per item No 189 above but 50 mm bore
All as per item No 189 above but 40 mm bore
All as per item No 189 above but 25 mm bore
All as per item No 189 above but 20 mm bore
Supply and fix connected Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves complete all as specified and directed by Engineer-in-Charge.
All as per item No 194 above but 50 mm dia.
All as per item No 194 above but 25 mm dia.
All as per item No 194 above but 20 mm dia.
All as per item No 194 above but 15 mm dia.
Taking out existing unserviceable/ broken / damaged CI sluice valve from its existing position and Supply & fixing CI sluice valve stainless steel, spindle CI body class –I, PN-1.6 ISI marked both end flanged and drilled and fixed by means of new nuts, bolts and washer including providing rubber gasket of suitable thickness of following sizes complete all as specified and directed by Engineer-in-Charge:-
All as per item No 199 above but 50 mm dia bore of pipe
All as per item No 199 above but 80 mm dia bore of pipe
M&L for replacement of unservicable CI non return valve type IS 5312 flanged ends 100 mm dia complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of unservicable CI non return valve type IS 5312 flanged ends 150 mm dia complete all as specified and directed by Engineer in Charge
S&F Foot valve of size 80mm suction pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fix steel pole tubular swaged 9 metres long complete with cast iron base plate , finialtaper plug , bolts , nuts and screws as specified type 410 SP-22 complete all as specified and directed by Engineer-in-Charge.
M & L cement concrete in foundation filling and mass concrete type B2 1;2;4 (40mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge.
M & L cement concrete in foundation filling and mass concrete type B2 1:4:8 (40mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge.
Supply and fix as in repair of 70W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed by Engineer-in-Charge.
Supply and fix as in reapir / replacement of pole mounted street light factory fabricated junction box of size 260 x 120 x 230 mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet , including 63A Single Phase two wire having two no.AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock having Size box fixed on pole using necerssary fixing arrangement such as clamps,nut,bolts and washer including taking down existing junction box of any description/type etc complete all as specified and directed by Engineer-in-Charge.
M/S Rohit Enterprises (BID ID -3089475)
YASHVI ENGINEERS (BID ID -3091585)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3086983)
M/S Anand Enterprises (BID ID -3090575)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .