SH A P SINGH, IDSE, CWE CHANDIMANDIR
HQ CWE CHANDIMANDIR
CA NO CWE/CHD-77/2021-22 REPAIR/ MAINT OF TRANSFORMER AND HT VCB/ OCB AND ALLIED WORKS AT K AREA GE CHANDIGARH
2022_MES_500826_1
CWE/CHD-77/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE CHANDIMANDIR
CLass D Cat b(ii)
8 documents required · 8 mandatory
₹500
Yes
GE CHANDIGARH
₹57,200
Yes
4 May 2022
11 Jan 2022
24 Feb 2022
11 Jan 2022
16 Feb 2022
2 Feb 2022
12 Jan 2022 - 19 Jan 2022
Amount
Excavation in trenches not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil in hard/ dense including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and protection covers. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations.
All as per item No 1 here-in-before but exceeding 1.5 mtr depth and not exceeding 3 mtr depth complete all as specified and directed.
Returning, filling in (soils) including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil (Soils) not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed by Engineer-in-Charge. Note. Only punned thickness shall be measured.
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.
Relaying PCC Cable cover/brick for cable protection retrived from item item No 01 here-in-before.
M&L for auger boring of holes under road, payment, hard standing by trenchless technology using ultra sounding technique and necessary machine for inserting of 100mm GI Pipe. Note 1. Length of bore hole under road/pavement shall be as per site reqirement. 2. GI Pipe shall be measured and paid separately under respctive item.
Disconnecting and taking out old existing unserviceable/ corroded GI tubing 100mm bore of any description and Supplying, laying & jointing GI tubing, 100 mm bore, Light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole/ along pole complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out old existing unserviceable/ corroded GI tubing 80mm bore of any description and Supplying, laying & jointing GI tubing, 80 mm bore, light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole/along pole complete all as specified and directed by Engineer-in-Charge.
Taking out existing damage/unservisable PVC\Pilca insulated, armoured, aluminium conductor 11000V grade cable of any size and core from trenches, pipes, walls and/or poles, complete all as specified and directed.
Supply, laying, jointing and testing 11 KV (Earthed), aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) amended upto date having cross sectional area 120 Sqmm 3 core complete all as specified and directed by the Engineer-in-Charge. Note :- Earth work, sand cushioning, pipe and PCC cable protection cover shall be measured and paid separately under respective items of sch 'A'.
All as per Item No. 12 here-in-before but cable of size 95 Sqmm 3 core complete all as specified and directed.
Blank
M&L for Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate in coping/padestal to poles including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 and applying two coats of white wash complete all as specified and directed.
M&L for HT heat shrinakable type straight through cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 50 to 95 Sqmm, 3 core complete all as specified and directed.
All as per ser item No 17 here-in-before but size 120 to 185 Sqmm, 3 core complete all as specified and directed.
M&L for HT heat shrinakable type indoor type joint end termination cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 50 to 95 Sqmm, 3 core complete all as specified and directed.
All as per ser item No 19 here-in-before but size 120 to 185 Sqmm, 3 core complete all as specified and directed.
M&L for HT heat shrinakable type outdoor type joint end termination cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 50 to 95 Sqmm, 3 core complete all as specified and directed.
All as per ser item No 21 here-in-before but size 120 to 185 Sqmm, 3 core complete all as specified and directed.
Dismantling and taking down carefully any type of pole complete all as spcified and directed.
Supply and erecting 11 metre long, Steel tubular swaged poles complete with and including cast iron/mild steel base plate, finial taper plug, bolts, nuts & washers etc as specified type 410 SP-55 conforming to IS 2713 including drilling of necessary holes including painting to poles up to 1200 mm height (from top of PCC coping) with two coats of synthetic enamel paint in alternate strips 300 mm high each in yellow and black paint and rest exposed surface of pole with two coats aluminium paint over a coat of red oxide zinc crome primer and black bituminous paint on embeded portion of pole including numbering on poles complete all as specified. Note : Excavation & earthwork, foundation concrete will be meaured & paid for separately under respective item(s) of schedule A.
Dismantling cross-arms of M.S. channel or angle sections etc. for re-use or issue under schedule of credit complete all as specified and directed.
Fixing only old servicable cross arm of MS Channel or angle section dismantled under item ser no 25 here-in-before above complete including painting with two coats of synthatic enamelled paint complete all as specified and directed.
Material, fabrication and labour for cross arms, bracing, supports and back plates fabrication from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, driling holes for bolts, in and shape or size as indicated or direction and inclusive of one primer coat and two under coat of synthetic enamel paint complete all as specified.
Dismantling of ACSR or AAC Conductor and setting aside for reuse or issue under sch of credit complete all as specified and directed.
Labour only for fixing of old serviceable aluminium conductor steel reinforced (ACSR) of any size/description on HT poles/lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified and directed by engineer in charege.
M&L for Aluminium conductor, steel reinforced (ACSR) of any size/description on HT poles/lines including stringing, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified and directed by engineer in charge
Supply and fix in repairs disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green: ‘single disc' assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
Supply and fix in repairs pin type insulator, porcelain, vitreous 150mm high and 150mm dia ball and socket type, white, brown or green: ‘single disc' assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
M&L in repair triple pole switches air break gang operated, (GO & DO complete assembly) , mechanically operated, mounted on 12 insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amp, 11000 volt and testing on completion complete all as specified and directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size in repairs complete all as specified and directed.
M&L in repair Lightning arrester single pole zinc oxide (Gap less) surge type suitable for use in effectively earthed system with nominal voltage 12 KV and shall comply with IS : 3070 (part -3) 1993 complete all as specified and directed.
Supply and fix in repairs 25mm bore Gun-metal, globe or gate valves, with iron wheel head, ISI marked, screwed both ends for iron pipe, in repair complete all as specified and directed.
All as per ser item No 36 here-in-before but size 32 mm complete all as specified and directed.
All as per ser item No 36 here-in-before but size 40 mm complete all as specified and directed.
Testing of Earth resistance with a caliberated earth megger after disconnecting the same from the equipment in presence of MES rep for all electrical equipments at sub stations and writing the result on the earth cover with black paint and in a separate earth test register including connecting the same after testing complete all as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below normal ground level) connected to GI strip 32X6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate No 03 with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point terminal block made out of phoshper bronzein sheet steel box, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar for handle, GI light grade watering pipe 20 mm dia bore with funnel and wire mesh, and 40 mm dia bore GI light grade earth lead protection pipe, complete all as specified and directed.
Dismantling the earth chamber, Excavation and removing the u/s earthing materials along with u/s earth electrodes from the existing u/s earth pits situated inside the K area and M&L for earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 2.25 mtr below normal ground level, connected to GI wire 4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20mm dia GI watering pipe ‘medium grade’, GI protection pipe of size 20 mm dia upto 7.5 mtr length , funnel with wire mesh, earthing chamber with cement concrete (1:2:4) type B-1, chamber cover 80mm thick RCC (1: 1 ½ : 3) type B1, excavation & earth work all as shown in electrical plate No 5 of SSR (Part-I) and testing on completion, complete all as specified and directed.
Disconnecting defective outdoor/ indoor power distribution transformer of capacity 50 KVA to upto and including 200 KVA from HT/ LT sides draining out complete transformer oil & storing the same in suitable containers ( to be arranged by contractor ) opening the top cover and lifting up the core assembly carefully to check the condition of transformer winding core, retanking the same after repair, refilling the transformer oil after dehydration and filteration (dehydration and filteration to be paid separately) including checking of leakage of transformer body and welding works required for making transformer body leak proof, transportation of transformer from site to workshop and from site to work shop and re-installation the same at any site complete all as specified and directed.
Disconnecting defective outdoor/ indoor power distribution transformer of capacity 250 KVA to upto and including 500 KVA from HT/ LT sides draining out complete transformer oil & storing the same in suitable containers ( to be arranged by contractor ) opening the top cover and lifting up the core assembly carefully to check the condition of transformer winding core, retanking the same after repair, refilling the transformer oil after dehydration and filteration (dehydration and filteration to be paid separately) including checking of leakage of transformer body and welding works required for making transformer body leak proof transportation of transformer to and from site to work shop and re-installation the same at any site complete all as specified and directed.
M&L for replacement of burnt /defective HT copper coil with new one made out of super enamelled heavy duty copper wires of size matching to the existing one including varnishing, drying and insulating material in transformer complete all as specified and directed.
M&L for replacement of burnt /defective LT copper coil with new one made out of super enamelled heavy duty copper wires of size matching to the existing one including varnishing, drying and insulating material in transformer complete all as specified and directed.
M&L for Replacement of existing defective HT tap changer of suitable size with tapping arrangement 2.5%to 7.5% and one normal tapping including connecting up with HT coil and testing of transformer capacity up to 200 KVA complete all as specified and directed.
All as per ser item No 46 here-in-before but capacity 250 to 500 KVA complete all as specified and directed.
M & L for replacement of synthetic rubberised cork sheet gasket 1/4" thick suitable for main body top cover of transformer. Capacity up to 200 KVA complete all as specified and directed.
All as per ser item No 48 here-in-before but 250 to 500 KVA complete all as specified and directed.
M&L for replacement of defective/ cracked HT porcelain bushing (set of three) of suitable size for transformer upto 200 KVA complete all as specified and directed.
All as per ser item No 50 here-in-before but above 250KVA and upto 500 KVA including washers of good quality complete all as specified and directed.
M&L for replacement of defective/ cracked LT porcelain bushing (set of four) of suitable size of transformer upto 200 KVA including washers of good quality complete all as specified and directed.
All as per ser item No 52 here-in-before but above 250KVA and upto 500 KVA complete all as specified and directed.
Supply and fix in repair HT bush rod made out of copper with brass nuts and washers of required length and dia (as per existing) including connecting up with HT coil of transformer upto 200 KVA complete all as specified and directed.
All as per ser item No 54 here-in-before but above 250KVA and upto 500 KVA complete all as specified and directed.
Supply and fix in repair LT bush rod made out of copper with brass nuts and washers of required length including and dia (as per existing) connecting up with LT coil of transformer upto 200 KVA complete all as specified and directed.
All as per ser item No 56 here-in-before but above 250KVA and upto 500 KVA complete all as specified and directed.
Supply and fix in repair breather with transparent body of suitable size duly filled with fresh silica gel complete for transformers of cap 250 KVA upto 500 KVA complete all as specified and directed.
All as per ser item No 58 here-in-before but capacity upto 200 KVA complete all as specified and directed.
M&L for taking down silica gel container from transformer and heating the silica gel at sufficient temperature to remove the moisture from it including refitting the same as per position complete all as specified and directed.
Testing of transformer oil of each transformer before and after dehyderation and filteration of transformer oil, installed in different sites for its dielectric strength and submitting the test report to the department.complete all as specified and as directed. Note : 1. Contractor shall arrange the oil testing machine and install at MES complaint cell of respective area. 2. Oil sample shall be collected from transformer in a air tight container and shall be tested at MES complaint cell of respective area in presence of MES rep. Amt of testing machine and container shall demmed to included in quoted rates.
Dehydration and filteration of existing transformer oil using transformer oil filteration plant to eliminate foreign particles and to improve di-electric strength upto 50 KV at 2.5mm electrode gap and to bring the acidity within the permissible limit complete all as specified and directed.
Supply and filling transformer oil for topping up the level of oil/ new filling, having dielectric strength 40 - 60 KV during filling after initial filteration, conforming to relevent IS-335 (Transformer oil to be supplied in sealed container) complete all as specified and directed.
M&L for painting of transformer upto 200 KVA capacity with good quality two coats of synthetic enameled paint using spray gun with compressed air on complete external portion of transformer including preparation of surface by scrubbing, cleaning ,stains greasy spots, dusts etc, The painting of transformer shall be carried out in situ ie. on four pole structure or in sub station at different places including writting SM/MES number complete all as specified and directed.
M&L for painting of transformer above 250KVA and upto 500 KVA capacity with good quality two coats of synthetic enameled paint using spray gun with compressed air on complete external portion of transformer including preparation of surface by scrubbing, cleaning ,stains greasy spots, dusts etc, including removing old paint. The painting of transformer shall be carried out in situ ie. on four pole structure or in sub station at different places including writting SM/MES number complete all as specified and as directed by Engineer-in-Charge.
Repair to arresting of leakage / replacement of worn out spindle (rod) / bushing / tap changer etc of any capacity transformer indoor/ outdoor type of any make & model, in position by disconnecting electric connection as required from HT/LT side cable box or bushing or jumper, opening of top cover with the help of mechanical Machine/ men power, drain out tranformer oil up to required level and to replace worn out spare / component with new one including replacement of UNSV gas kit set of top cover and making necesary inetrnal & external connection, refilling drain out oil etc complete all as specified
All as per item No 66 here in before but arresting of oil leakages from body / tubes fins etc complete all as specified and directed. Note for item No 66 & 67 Any spares required will be measure paid under respective items of this schedule.
M&L for PG clamp suitable for upto 50 Sqmm copper conductor in repair complete all as specified.
Disconnecting the exsiting 11 KV outdoor type gang operated air break switch, carring out the repairs which includes changing the flexible copper strip of rating 75 Amp capacity, changing the Male/Female contacts, springs, greasing , welding & drilling work etc refixing in position & testing to check the system on full load complete all as specified and directed. Note : - (a) Contractor should visitied the site to assess the repair involved before quoting the rate . (b) Spares / material required in repair will be masured & paid sparely under relvent item as the supply only.
Supply only post top insulator suitable for 11 KV Air brake swicth 11 KV Drop out fuse complete all as specified and directed.
Suppy only Tinned copper flexible strip (Jumper) suitable for 11 KV Air brake Switch complete all as specified and directed.
Supply only male contact for 11 KV Air brake switch complete all as specified and directed.
Supply only female contact for 11 KV Air brake switch complete all as specified and directed.
Supply only MS Strip operating mechanism (Jumper Carrier) for GOD insulator complete all as specified and directed.
Supply only terminal clamp suitable for 11 KV out door AB switch complete all as specified and directed.
Supply and fix MS sheet 5 mm thick for transformer HT/ LT side cable box cover, including cutting as per site requirement, drilling, welding, painting including two coat good quality synthetic enameled paint over a coat of primer complete all as specified and directed. Note. MS box cover shall be provided with PU gasket and suitable size cable gland to ensure IP 66 protection.
Supply and fix MS bolt fully threaded with nut and washer with zinc oxide coating of suitable size complete all as specified and directed.
Renewal of old burnt out ACSR jumper at two pole/four pole structures complete all as specified and directed. Note : ACSR required for renewal of jumpers shall be measured and paid separately.
Disconnecting and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of indoor epoxy type 11 KV current transformer having ratio of 100-5-/5A having protection core class 1P10, IL-28/75kv burden of 10 VA and breaking cap of 18.4 KA for 1.0 second all as specified and directed.
All as per item ser No 79 here in before but CT ratio 60/1A and 2.5VA complete all as specified and directed.
All as per item ser No 79 here in before but CT ratio 40/1A and 2.5VA complete all as specified and directed.
Disconnecting and taking out old U/S battery charger and Supply ,Installation, Testing and commissioning of 24 Volt DC ,low maintenance type chargeable stationary battery set comprising of 12 cells of 02 volts each having 100 Amp hour capacity batteries including battery charging set of adequte capacity and control equipment in sheet steel cabinet of 2.0 mm Thick floor mounted type suitable for input of 230 volts single phase 50 Hz AC complete with internal & External wiring of all components accessories, all as specified for 11 KV VCB panels, with complete control wiring (for connecting the DC tripping system to HT 11 KV VCB panel board of TOP complete ) wiring shall be of copper conductor single core and size not less than 2.5 Sqmm complete all as specifed and as directed by Engineer-in-Charge. Note. cost of control wiring up to VCB panel shall deemed to be inclusive in quoted rates.
Taking down the existing relays (Three phase over current and earth fault relays) fixed in 11KV HT panels and replace new (Three phase over current and earth fault relays) model No M 61 A Aux supply 110 volt with (2NO+2NC) CT rating current 1 Amp to 5 Amp complete Cat Part No MC61AAXX001 of L&T or equivalent make specified in Appx 'B' complete all as specified and directed.
M&L for servicing, caliberation and testing of 11KV, 400/600 Amp VCB indoor type along with control panel and control wiring protection system and relays by primary & secondary injection system all as directed including testing of battery bank/battery charges/ DC system, rectification of fault if any all as specified and directed.
Disconnecting & taking out non functional VCB of any description and any make of rating 11 KV, 400 Amps/630 Amps dismantling / opening of the VCB for servicing / overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing complete all as specified and directed by Engineer-in-Charge. Note :- Cost for fixing the serviceable parts in position and replacement of unserviceable parts with new parts shall deemed to be included in quoted rates. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as supply only.
Supply only Vaccum interrupter (Vacum bottle) type WL -33379 for VCB, 400/630 Amps capacity indoor type of Note : Cost of fixing & testing element of items ser No 86 to 96 is deemed to be included under quoted rates of respective items.
Supply only flexible connectors Cat No. 531 complete all as specified and directed.
Supply olny Closing coil assembly 30 Volt to 110 Volt complete all as specified and directed.
Supply only Tripping coil assembly 30 Volt to 110 Volt complete all as specified and directed.
Supply only PG clamp
Supply only LED Indicator lamp (RYG) 110 Volt complete all as specified and directed.
Supply only LED Indicator lamp (RYG) 30 Volt complete all as specified and directed.
Supply only Heating element with thermostat switch 150Watt compact type complete all as specified and directed.
Supply only Operating handle for trolly, lowering/raising suitable for any capacity of VCB as per sample complete all as specified and directed.
Supply only Gear assembly suitable for VCB 400/630 Amp
Supply only tinned copper fuse wire 18/20 SWG complete all as specified and directed.
M&L for anticlimbing devices, spike type fabricated out of MS bars (round square and flat) including nuts, bolts washers and welding in tow halves made to shape to suit the cross section of the HT Pole complete all as specified and directed.
M&L stay assembly for HT Poles comprising of 20mm dia, 2.15mtr long galvanized stay rod, having 7/3.15mm GI stay wire stranded and 300mmx500mmx6mm thick MS stay plate, complete all as shown on electrical plate No-1 of SSR, Part-I with and including all necessary fitting/accessories like loop type insulator overall dimensions 90mmx140mm, clearance of hole 25mm, shackle & stay C-2 (using 40mm graded stone aggregate) including taking out and dismantling old unserviceable stay assembly complete all as specified and directed by Engineer-in-Charge
M&L for cable route indicator for HT 11 KV cable of size 4" dia Round plate with stand of angle Iron duly marked with HT 11 KV /MES including necessary PCC for fixing complete all as specified and directed.
Material and labour for cleaning and preparation of all existing steel surfaces of straight steel tubular poles 11mtrs long for painting including mild steel cross arms, clamps and street light brackets, MS boxes etc and applying one coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of pole including writing pole No and other sign works with white paint over black painted base in the pattern and style as approved by the Engineer-in-Charge complete all as specified & directed. Note : Size of black painted base for numbering shall be 100mmx25mm and the size of numbers shall be not exceeding 10cm height.
All as per Item No - 100 here-in-before but double pole structure complete all as specified and directed.
All as per Item No - 100 here-in-before but four pole structure complete all as specified and directed.
M&L for cutting & trimming of tree trunks / branches of grith not more than 80 mm falling on or likely to fall on HT/LT over head electrical lines for a clearence of 6 meter on ground from the nearest counductor / pole /earth etc. & disposal of unservicable materials to distance not exc. 50 mtrs. & clearing of site all as directed by Engg.-in- Charge.
Taking down old U/S sign board any type and from any position and M&L for informatory LED Glow sign display board with all necessary electrical wiring and conection with battery backup of 06 hrs of size 2.00mtrx1.20Mtr LED desplay in red colour as (E/M COMPLAINT CELL AGE E/M K AREA) duly supported with MS sheet from the back side and stiffened with angle iron of size 25x25x4mm to with stand wind pressure. LED glow sign board to be fixed on Chromium plated Stainless steel pipe frame of 50mm dia, at 2.5mtr height complete all as per ground requirement and as directed by Engr-in-charge. Note:- The cost of Excavation post hole, earth work, PCC for foundation etc shall deemed to be included in the quoted rates.
Supply and fixing LED type solar street light fitting 20 watt with following features/specification:- 1. Luminaire:- Aluminium housing LEDs for light source optics with high effeciency driver & MPPT charge controller, Excellent heat dessipation IP 65 protection, High birghtness and high efficiency of more than 120 lm/W new age LEDs, individual peanut optical lenses for uniform light distribution system output: 2200 lm. 2. Solar Panel :- Polycrystaline solar cells. 3. battery :- Input (LifeP04) 12.8 Volt 40AH Lithium battery, weather proof, long back-up ideal for cloudy conditions. 4. Pole:- Galvanised pole, Rigid and safe, corrossion free length 6 mtr. with optimum thermal management and heat sink design and microprocessor based charge controller and led driver maximizes the performance of panel & battery complete all as specified and directed. Note. Cost of assembling of the complete fitting and its testing before and after mounting or errection in PCC etc for proper functioning shall deemed to be includied in quoted rates. Evcavation and earth work shall be measured and paid seperately under respective items of schedule 'A'.
M&L for minor repair like replacement of fuse of suitable capacity, re-stretching, tightening and jointing of broken HT conductors in routine/natural calamity to ensure uninterrupted power supply of HT overhead lines from MRS to various distribution transformer of Unit/Residential area of DEAL and replacement of spares of VCB,s etc. Complete all as specified and directed at site. Note:- Burnt/ spare parts (ACSR Conductor, Fuse wire PG Clamp of suitable capacity, tripping coil and closing coil, locking pin, LED type indicators shall be paid separately under Sch A.
Dismantling of old unsv RCC Security/cattel fencing post any type/ size including demolition of PCC from foundation and stacking where directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) in Soft Loose Soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed.
S&F Mild Steel work of channel, angle iron any sections, as in post and struts for cattle/security fencing including cutting top to shape drilling holes notching for wire etc flat iron fillets wire mesh including as in fencing post including all necessary drilling bolting, riveting etc and similar work conforming Fe 410-W(Gde-E-250) quality A. complete including painting with one coat of red oxide as primer under coats of synthetic enamel black paint all as specified and as directed by Engineer-in - Charge
Supply only chain link MS galvanised fencing incl line wire 50x50mm mesh (12 gauge) size and any type of strands, rails, straining bolts etc including provn of binding wire complete all as specified and directed. Note. Weight of chain link fencing shall be ascertained by BOO convened by the GE.
Fixing only chain link fencing including line wire any mesh, size and type of standards, rails, straining bolts, etc including binding wire etc complete all as specified and directed. Note. Chain link fencing and line wire shall be measured and paid as supply only.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, welding, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Sabhyata Electrical and Mechanicals
Northern cable fault locatoers
Raman Electric Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .