Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹28.6 L+₹3.0 L (11.6%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹29.8 L+₹4.2 L (16.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹32.3 L+₹6.7 L (26.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹29.6 L
EMD Value
₹59,300
Closing Date
6 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Sachin Sharma CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
PROVN OF 01 X SENTRY POST, 01 X R AND D ROOM, HARD STANDING AND ADDN/ALTN TO MAIN GATE OF HQ NORTHERN COMD CAMP UNDER GE (SOUTH) UDHAMPUR
2022_MES_562519_1
CWE/U(S)-74/2022-23
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (S) UDHAMPUR
₹59,300
Yes
15 Dec 2022
11 Nov 2022
8 Dec 2022
11 Nov 2022
6 Dec 2022
24 Nov 2022
Amount
Surface excavation not exc. 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beam; plinth beams; bases of columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate. as in chajjas all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
RCC M-25 Design mix, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and includingMS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, to obtain rough finished flat surfaces of concrete complete all as specified and as directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions etc, square, ractangular or polygonal, to obtain rough finished flat surface of concrete complete all as specified and as directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. to obtain rough flat finished surface of concrete complete all as specified and as directed.
Use and waste of form work to chullah hoods, chajjas, troughs and similar items including edgesetc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed by Engineer-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Broken stone hardcore of gauge exceeding 63 mm but not exceeding 100mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engr-in-Charge.
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floor, complete all as specified and as directed by Engr-in-Charge.
Vitrified tiles (light shade) of 10mm thick coloured (area of each tile not exceeding 0.36 sqm) as in floors jointed in cement slurry and pointed in white or coloured cement to match the existing surfaces over and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic jointfree/rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic jointfree/rectified tiles 300x600mm and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
M & L exterior Wall cladding tiles in vertical surface 300x450x7mm or 300x600x7mm thick or as size as directed by Engr in Charge laid over 10 mm thick screed bed in CM 1:4,set and joint in neat cement slurry and pointed in white or colour cement to match complete all as specified.
S&F Dura stone tiles of size 300mmX300mmX10mm thick as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
75 mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in plinth protection complete, all as specified.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, complete all as specified and as directed by Engr-in-Charge.
S&F for steel door including projecting type hinges, steel handles , complete with glazing bars , dovetailed or welded complete all as specified.
S&F Ornamental and intricate design for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe -290 Gde-E-165 complete all as specified.
Material and labour for 12 mm thick toughened glass partition and similar work with fixing of stain less steel clit/stain less steel clamp and fixing aluminium frame wall and floor complete all as specified and as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab or gate pillar with suitable arrangement complete all as specified and as directed.
S&F Powder coated 15 micron aluminium door of approved design complete all as specified/directed with all fixing arrangement including providing and fixing door handle, tower bolts, mortice lock 6 lever (Make - Harrison/Godrej) one on each door and , aluminium Powder coated tower bolts 200 mm long (03 Nos on each shutters) and 5 mm thick tinted glass pane of glazed shutter along with aluminium glazing beading of size 19.00 mm x 17.5 mm x 0.70 mm @ weight of 0.097 Kgs per RM including rubber gasket on both side complete alongwith neoprene lining. The member shall be made out of extended aluminium section comprising of :- (Size of the door shall be as per site requirement) (a) Door frame of size 95.25 mm x 44.50 mm x 1.70 mm @ 1.301 Kg/RM.. (b) Shutter vertical member 85 x 44.50 x 1.56 mm @ 1.39 Kg per RM. (c) Shutter top member 83.50 x 44.50 x 1.54 mm @ 1.139 Kg per RM. (d) Shutter bottom member 101.60 x 44.50 x 1.60 mm @ 1.301 Kg per RM. (e) Shutter lock rail member 83.50 x 44.50 x 1.54 mm @ 1.139 Kg per RM.
S&F Aluminium powder coated frame with window shutters (glazed, wire gauge and grill) side hung or three track with aluminium window frame or chowkat 1.5 mm thick aluminium powder coated of size 100 mm x 44.5 mm and window shutter frames glazed and wire gauze (middle, top rail, bottom rail) and styles 1.5 mm thick aluminum powder coated of size 44.5x44.5 mm incl powder coated aluminium grill 50mm x 50mm aparture and all fitting such as rubber gasket, aluminium glazing clips locking cabinet, 4 mm thick tinted glass pane for glazed shutters, stainless steel wire mesh for gauge shutter and hook and eye for each shutter fixed with rubber gasket and glazing clip/aluiminium beads aluminium tower bolt 75 mm 02 Nos each shutter, aluminium butt hinges 75 mm 02 Nos in each shutter aluminium handle 100 mm 01 No in each shutter inc all accessories complete all as specified and directed.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
S&F Aluminium Camposit Panel (ACP) wall paneling 6 mm thick HPL sheet, aluminium cover sheet thickness 0.5 mm, panel length 2240 mm and width 1220 mm, interior face coil coated with polyster, fixing with aluminium tube/ aluminium chanel with aluminium /steel rivet/screw in any position and height in any colour including preparation of concrete surface for ACP as per direction of Engr-in-Charge.
S&F Stainless Steel box type writing letters (Block, Romen, Italic or Indian) of size 300mm hight, 50mm wide and 10mm depth(thick) or size as approved by Engr in charge complete all as directed.
M&L for plain cement concrete1:2:4 type B-2 using 40 mm graded stone aggregate as in channels and drains, foundation and similar work etc complete all as specified and as directed.
Precast Reinforced cement concrete 1:2:4 (Nominal mix) type B-1, using 20mm graded crushed stone aggregates landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves, fins and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar 1:4 complete all as specified.
Material and labour for APP polymaric water proofing membrene minimum 3mm thick and weighting not less than 3.6 kg / sqm of make 'Moply FP' manufactured by STP Texsa Ltd or' Hyper Plas' ( polyster) manufactured by M/S IWL Ltd or'Shaliplas' (polyster) manufactured by M/S Capital Steels and chemicals Pvt Ltd or 'Mak polyplast' manufactured by M/S M K Petro as approved by GE , black finished reinforced with non weven polyster matt,with fusable finish laid over compatable bitumen primer at the rate of 0.40 Ltr/Sqm torching overlaps with a propane or abutane gas torch, with a over lap of 75mm at the sides and100 at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufactur's instructions including 0.40 Ltr/Sqm torching overlaps with a propane or abutane gas torch, with a over lap of 75mm at the sides and100 at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufactur's instructions including preparation of surface, complete all as specified and as directed. Note : the water proofing treatment shall be carried out by the manufacturer or their authorised applicators.
Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide/zink chrome primer complete, complete all as specified and as directed by Engr-in-Charge.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L for two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed.
Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-Charge.
18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and polishing over and including 15 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engineer-in-Charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed.
25 mm thick, Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M & L for Coloured Chequered tiles lacquer finish of size 30cmx30cmx20-25mm thick, set jointed and pointed in neat cement slurry as in path with white cement and pigment etc and including 15 mm thick screed bed or bedding layer in cement mortar 1:3, complete all as specified and as directed by Engr-in-Charge.complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
Machine pressed (factory made) precast plain cement concrete 1:2:4 type B-1(20mm graded crushed stone aggregate), kerb stone & the like of size 300mm x 300mm x 100mm thick or of size as approved by GE, with plain fair faces including chamfers, weathering etc, embedding in position/laid in trenches on edges of roads, including excavation in any type of soil, setting in cement mortar (1:4) returning filling and removal of surplus soil/debris to a distance n.exc. 50m from the starting point, complete all as specified and directed.
Plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in steps, seismic and other similar bands, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, cills, lintels upto 1.50 metre clear span, copings etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works, complete, all as specified and directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, medium grade and all accessories for one light / fan controlled by one switch suitable for pressed GI terminal boxes (modular type) of required modules concealed on walls including inner and outer sheet for fixing of modular switches/socket/ regulator etc along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified & directed by Engr-in-Charge. Note: (i)Modular metal flush boxes & cover plates are deemed to be included in quoted rates. (ii)Cutting, chases and making same the wall patches after laying the wire and conduits using putty, whitewash and distemper.The surface shall be made smooth using putty and should match exactly with the existing wall finish.The cost of this aspect is deemed to be included in quoted rates.
Description all as per item No 57 above but 05 Amp socket outlet controlled by one switch on independent board .
Description all as per item No 57 above but 05 Amp socket outlet controlled by one switch on same board with other switch.
Description all asper item No 57 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
All as per item No. 57 above but for one light point controlled by 2 Nos.of two way switch, complete all as specified and directed by Engr -in-charge.
Modular switch single pole two way 10 Amps 1 module type complete all as specified and directed by Engr- in-charge
Modular bell push single pole one way 6 Amps 1 module type complete all as specified and directed by Engr- in-charge
Switch piano , single pole,1 module, one way ,16 Amp (modular type) , complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 2 in 1, 3 pin 06 Amp flush type modular type, complete all as specified and as directed by Engr-in-Charge.
Modular socket, 6/16Amps, 2/3 pin combined 2 module, complete all as specified and as directed by Engr-in-Charge.
Modular type stepped type fan regulator 120W, 230V 50 C/S, Deluxe 2 Modular electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V with 400 Amps rated bus bar, double door type with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications, fixed in repairs, complete all as specified and as directed.
Material and labour for replacement MCCB 100 Amps, 4 Pole, 16KA, 415 Volts. Complete all as specified and directed by Engr-in-Charge.
MCB SPN, 40 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 10 to 40 Amps, 'C' series 10 KA 240 Volts including providing aluminium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 75 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Angular lamp holder PVC polycarbonate type with cord grip cap suitable for light fittings, complete all as specified and as directed by Engr-in-Charge.
S&F in LED Bulb 15W, 230V, AC suitable for angular Lamp holder, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engr-in-Charge.
Environmental friendly, energy saving, surface mounted, decorative LED 10 Watt Bulk head luminire, with integral electronic LED driver with APFC and lower THD, Output complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following :- (a) Housing of Light fitting : Die Cast Aluminium (b) Diffuser : Polycarbonate UV protected diffuser (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 900 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4kV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engr-in-Charge.
S&F New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, fixed in repair, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection: Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe 32mm bore, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , complete all as per the direction of Engg-in-Charge.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge. Note: Earth work and other connected work shall be measured & paid sperately.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 6 sqmm 2 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge. Note: Earth work and other connected work shall be measured & paid sperately.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
S&F exhaust fan, steel body, 300mm sweep, AC single phase ,230 Volts, including blades, frame,louvers etc., complete all as specified and directed by Engr-in-Charge.
vijay constrction co
joginder singh and sons
VIRINDER SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .