| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-Finance | L1 | Accepted-Finance TECHNICALLY AND FINANCIALY QUALIFIED | |
| 2 | L2₹7.0 L+₹12,410 (1.80%)Accepted-Finance | L2 | Accepted-Finance TECHNICALLY AND FINANCIALY QUALIFIED | |
| 3 | L3₹9.0 L+₹2.1 L (30.4%)Accepted-Finance | L3 | Accepted-Finance TECHNICALLY AND FINANCIALY QUALIFIED | |
| 4 | L4₹9.3 L+₹2.4 L (34.2%)Accepted-Finance | L4 | Accepted-Finance TECHNICALLY AND FINANCIALY QUALIFIED |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
17 Aug 2022, 11:00 amClosed
EXECUTIVE ENGINEER KPDCL DIV SHOPIAN
OFFICE OF EXECUTIVE ENGINEER KPDCL SHOPIAN
Stage Contract for Creation Augmentations of Substations of various capacities Improvement Erection of HT LT network under various Schemes for the FY 2022 23 falling under jurisdiction of KPDCL OM Division SHOPIAN ON TURNKEY PARTIAL TURNKEY
2022_PDD_182826_1
EDS/ETENDER/37 DATED 05/08/2022
Open Tender
Electrical and Maintenance Works
Turn-key
210 days
SHOPIAN
PLZ REFER TO SBD ENIT
8 documents required · 8 mandatory
₹500
Convener, purchase committee, Directorate of ISM
₹20,000
Yes
25 Aug 2022
5 Aug 2022
17 Aug 2022
6 Aug 2022
17 Aug 2022
6 Aug 2022
6 Aug 2022 - 6 Aug 2022
Amount
Providing, Errection,testing & commissioning of 11 Mtr long ST Poles 410, SP-56 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders.
Providing, Errection,testing & commissioning of 9 Mtr long ST Poles 410, SP-33 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders.
Providing,Errection,testing & commissioning of 8 Mtr long ST Poles 410, SP-15 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders.
Providing, errection, testing & commissioning of 8 Mtr long PCC Poles including manual, mechanical carriage, excavation of pole pits with inscription of permenent marking on each pole "Name of scheme-2019-20/xx" (xxx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place
Providing, Errection testing & commissioning of H & A type double pole Structure complete with pit excavation & refilling including fixing of 01 No. Cross-arm, Top pin Clamp, Insulators & Braces for 11 kV line.
Providing & fixing of pole earthing as per REC standard as per J-1 (spiral earthing) drawing
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) inscribed with permanent marking on each pole "Name of scheme-2019-20/xx" (xx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place. The paint shall have to be sprayed not brushed.
Providing, errection, testing & commissioning of channel cross arms, V-Cross arms, Sub-station channels & Angle Iron Braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of Galvanized Iron of different sizes (REC Standard) & to be fixed with GI Nuts & Bolts and washers.
Providing, errection, testing & commissioning of channel cross arms, V-Cross arms, Sub-station channels & Angle Iron Braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of Mild Steel of different sizes (REC Standard) & to be fixed with GI Nuts & Bolts and washers.
Providing & and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN)
Providing & fixing of 11 kV, G.O AB Switch , 3-phase, 200A (09 insulator post type) with arragement for pad locks & operating rod . The operating rod should be G.I Pipe (B-class) of 25 mm dia of requisite length.
Providing & fixing of 11 kV Horn, Gap Fuse 3-phase 100A
Providing & fixing of 11KV Link set 3-phase, 200 A (station type)
Providing & fixing Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type
Providing & fixing of LT Fuse set incomer 40 Amp ( 25 KVA)/100 Amp(63KVA)/160 Amp (100 KVA)
Providing & fixing of 11 kV Disc Insulators (polymer) Complete with fitting( 45 KN)
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 400 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 300 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 185 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 120 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 95 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing, laying, testing & commissioning of 3x35mm sq +1x105mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminium conductor screened with Black extruded semi conducting compound, natural coloured XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires.
Providing, laying, testing & commissioning of 3x50mm sq +1x70mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminium conductor screened with Black extruded semi conducting compound, natural coloured XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires.
Providing, laying, testing & commissioning of 3x70mm sq +1x95mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminium conductor screened with Black extruded semi conducting compound, natural coloured XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires.
Providing, laying, testing & commissioning of 3x120mm sq +1x95mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminium conductor screened with Black extruded semi conducting compound, natural coloured XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires.
Providing, fixing , testing & commissioning of cable kits ( heat shrinkable)
Providing, fixing , testing & commissioning of cable kits ( push on type)
Providing & fixing of Suspension/Tension clamps with eye hooks assembly
Providing & fixing of Dead end clamps
Providing and fixing of Anticlimbing devices on poles of GI barbed wire type devices). At-least 3.5 kgs GI barbed wire(12 SWG)
Providing and fixing of Danger Plates on poles with clamps and writing in English and Regional Language
Providing & fixing of Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per REC standard.
Providing, laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole including muffing 20 cm above ground level, plaster and curing of concrete.
Providing & fixing of bi-metallic clamps for fixing of LT cable with distribution transformers having capacity upto 100 kVA
Providing & fixing of bi-metallic clamps for fixing of LT cable with distribution transformers having capacity of 25 KVA & above
Providing & fixing of 300 mm sq Aluminum Thimbles for cable terminations
Providing & fixing of 185 mm sq Aluminum Thimbles for cable terminations
Providing & fixing of 120 mm sq Aluminum Thimbles for cable terminations
Providing & fixing of 95 mm sq Aluminum Thimbles for cable terminations
Providing and and fixing of 3 No. sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 for neutral earthing and 25X3 mm for 2 transformer body earth, two no. pole earth, 1 no. LA Earth and 1 no. GO handle earth as per REC approved construction standards with F5, F10 & J2 drawings issued by REC as reference. Each electrode to be connected through double GI strips to be fixed on baby insulators. The termination should be bolted and not welded.
Providing Errection, Testing & commissioning of LT Distribution Box for 25/63/100 KVA DTR with TPN of 160 A-200 A with breaking capacity of 36 kA MCCB (L&T, Hager, Legrand make) . The MCCB should be housed in enclosure fabricated out of MS sheet of 18 SWG duly powder coat painted.
Providing Errection, Testing & commissioning of LT Distribution Box for 250/40/630 KVA DTR with TPN of 315 A-400 Awith breaking capacity of 50 kA MCCB TPN (L&T, Hager, Legrand make) . The MCCB should be housed in enclosure fabricated out of MS sheet of thickness not less than 2 mm duly powder coat painted.
Providing and fixing of shackle insulators Shackle Insulators (Porcealin) ( 16 KN) with LT U Clamps complete
Providing & and fixing of 11 kV Pin Insulators (porcealin) with G.I. Pins ( 5 KN)
Providing and fixing of shackle insulators Shackle Insulators (polymer) ( 16 KN) with GI back clamps to be fixed without drilling/punching of poles on ST poles.
Providing, Laying, stringing, tensioning and binding of conductor ACSR 0.1 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices
Providing, Laying, stringing, tensioning and binding of conductor ACSR 0.05 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices
Providing, Laying, stringing, tensioning and binding of conductor ACSR 0.0.3 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices
Loading, Transportation, Errection,testing & commissioning, Carriage and Delivery at Site of 11 Mtr long ST Poles SP-56 including excavation of pole pits, refilling the pit with soil, boulders.
Loading, Transportation, Errection,testing & commissioning ,Carriage and Delivery at Site of 9 Mtr long ST Poles SP-33 including excavation of pole pits, refilling the pit with soil, boulders.
Loading, Transportation, Errection,testing & commissioning, Carriage and Delivery at Site of 8 Mtr long ST Poles SP-15 including excavation of pole pits, refilling the pit with soil, boulders.
Loading, Transportation, Errection, testing & commissioning, Carriage and Delivery at Site of 8 Mtr long PCC Poles with excavation of pole pits with inscription of permenent marking on each pole "Name of scheme-2019-20/xx" (xxx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place
Providing & fixing of 11 kV Disc Insulators (porcealin) type with G.I fittings( 45 KN)
Loading, Transportation, Installation, Testing, Commissioning of 25 kVA Distribution Transformer including mechanical/manual carriage upto site of installation and fixing of all fittings and jumpers
Loading, Transportation, Installation, Testing, Commissioning of 63/100 kVA Distribution Transformer including mechanical/manual carriage upto site of installation and fixing of all fittings and jumpers
Loading, Transportation, Installation, Testing, Commissioning of 200/250/400 kVA Distribution Transformer including mechanical/manual carriage upto site of installation and fixing of all fittings and jumpers
Loading, Transportation, Laying, stringing, tensioning and binding of conductor ACSR 0.1 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site.
Loading, Transportation, Laying, stringing, tensioning and binding of conductor ACSR 0.05 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site.
Loading, Transportation, Laying, stringing, tensioning and binding of conductor ACSR 0.03 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site.
Errection, testing & commissioning of channel cross arm, V-Cross arms, Sub-station channels & Angle Iron Braces, transformer beltings etc to be fabricated out of Mild Steel of different sizes & to be fixed with GI Nuts & Bolts and washers.
Dismentling of 11 Mtr long ST Poles including carriage to divisional stores,
Dismentling of of 9 Mtr long ST Poles including carriage to divisional stores,
Dismentling of of 8 Mtr long ST Poles including carriage to divisional stores,
Dismentling of of PCC Poles including carriage to divisional stores without damaging / breaking the pole. If the pole gets damaged no payment will be made.
Dismentling of of wooden Poles including carriage to divisional stores,
Repositioning of 11 mt ST tilted poles
Repositioning of 9 mt ST tilted poles
Repositioning of 8 mt ST tilted poles
Repositioning of PCC tilted poles
Repositioning of tilted wooden poles
Dismantling of conductor ACSR 0.1 including hardware fittings and returning the dismantled material to stores.
Dismantling of conductor ACSR 0.05 including hardware fittings and returning the dismantled material to stores.
Dismantling of conductor ACSR 0.03 including hardware fittings and returning the dismantled material to stores.
Re-stringing, tensioning and binding of conductor ACSR 0.1 including fixing of hardware fittings and jointing as per standard practices
Re-stringing, tensioning and binding of conductor ACSR 0.05 including fixing of hardware fittings and jointing as per standard practices
Re-stringing, tensioning and binding of conductor ACSR 0.03 including fixing of hardware fittings and jointing as per standard practices
Branch cutting
Opening of connections /lifting from bed, Loading of damaged Distribution Transformer of Capacities 25/63/100 KVA & Reinstallation of same after Repairs
Opening of connections /lifting from bed, Loading of damaged Distribution Transformer of Capacities 250 KVA & Reinstallation of same after Repairs
Dismantalling ,Dragging Loading ,unloading of ST 9 mtr long Poles and transportation and re errection of the same at new sites
Dismantalling ,Dragging Loading ,unloading of ST 8 mtr long Poles and transportation and re errection of the same at new sites
Dismantalling,Dragging & reinstallation of old 250 KVA Transformer
Dismantalling,Dragging & reinstallation of old 63/100 KVA Transformer
Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection
Sunbeam Enterprises
Reaching Rays Infra Electricals
SHAMEEM AHMAD DAHAL
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .