Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.5 LAccepted-AOC NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹50.0 L+₹1.4 L (2.87%)Rejected-Finance 227 2 5TH B MAIN ROAD 2ND BLOCK HRBR LAYOUT KALYAN NAGAR BANASAWADI BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
8 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
ADDN ALTN AND PROVISION OF TOILETS AND OTHER MISC AMENITIES FOR AGNIVEERVAYU WOMEN AND CERTAIN MINOR WORKS AT AF STATION JALAHALLI AND AFTC
2024_MES_672041_1
8950/E8
Open Tender
Civil Works
Item Rate
181 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹1 L
5 Nov 2024
5 Sept 2024
15 Oct 2024
5 Sept 2024
8 Oct 2024
19 Sept 2024
5 Sept 2024 - 12 Sept 2024
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m deep for foundation etc., and getting out in hard/dense soil complete all as specified and as directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded crushed stone agg) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L Hard core of gauge n.exc.63mm with broken stone boulders, deposited spread and levelled in layers not exc 15 cm thick, watered and rolled, rammed to a true surfaces complete all as specified and as directed.
M&L for pre-cast PCC 1:3:6 type C1 (20 mm graded agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 all as specified and directed.
M&L RCC 1:2:4, type B1 using 20 mm graded crushed stone aggregate (nominal mix)as in plinth beam/band etc mixed with integral water proofing compound.(WPC shall be measured and paid separately) complete all as specified and as directed.
Supply only integral water proofing compound of approved make complete all as specified and as directed.
Cutting openings, through stone walls of thickness 480mm with proper care, for door openings or enlarging existing openings.converting window into door openings, etc including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks/stones, hard-core, etc.. to store and rubbish not exc. 50m distance complete all as specified and as directed.
S&F of perforated GI steel lintel of thickness 3mm complete all as specified and as directed.
M&L TMT bar 10mm dia & over deformed & twisted bars cut to length ,bent to shape required incl cranking , bending , hooking, for lintel and binding with MS wire not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M&L for TMT bars 6 to 8 mm dia in stirups cut to length bent to shape required including cranking, hooking ends etc and binding with MS wire not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Formwork to sides of concrete foundation,footing,base of columns,raft and raft beam,sides and soffits (if any) of foundation and plinth beams,and similar works,vertical or to batter rough finished flat surface of concrete complete all as specified and as directed.
M & L for 100 mm thick PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in sub base, pavings, mass concrete surface finished even and fair complete all as specified and directed .
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates as reqd forming holes bolted and welded attchment and curved shaped by welding (thickness of metal n.exc.6mm) making jointless by filling including cutting of Fe 410- B etc complete all as specified and as directed.
S&F for galvalume sheets AZ-150 having pitch 190mm, depth 29mm and thickness not less than 0.50mm (Galvalume base- trapezoidal profile sheets) fixed with aluminium self taping screws of size 50/75mm and aluminium washer of suitable size in roof covering, gutters and cladding complete all as specified nad directed. (Over lap shall be as specified by manufacturer)
S&F for galvalume sheets AZ-150 plain sheets having thickness not less than 0.50mm (Galvalume base) fixed with aluminium self taping screws of size 50/75mm and aluminium washer of suitable size in roof covering, gutters and cladding all as specified. (Over lap shall be as specified by manufacturer)
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint on new steel surface of any description over a coat of red oxide primer complete all as specified and as directed.
Returning filling in, including spreading, leveling,watering and well ramming in layers n exc 25cm thick, complete all as specified and as directed.
Filling under floor in layers not exc 25 cm incl spreading, levelling watering etc complete using soils retrieved from excavation complete all as specified and as directed.
Removing excavated material not exceeding 250m and depositing where directed at a level not exceeding 1.5m above the GL from the starting point all as specified and directed.
M&L 15mm thick rendering on external fair faces of brick work or concrete surfaces in CM 1:4 mixed with water proofing compound and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured & paid seperately.
M&L preparation of plastered surfaces of walls and applying two coats of cement base paint over primer alkali resistance on new surfaces complete all as specified and as directed.
M&L for non skid ceramic coloured joint free mat finish tiles 7-8mm thick area exceeding 0.18 Sqm of each tile and not exc 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in CM (1:4) complete all as specified and directed..
M & L for coloured glazed ceramic tiles of size 7-8 mm thick jointless tiles of size 300x600 mm on vertical surfaces such as skirting, dado etc, set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick rendering in CM 1:3 complete all as specified and as directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard dense soil complete all as specified and as directed.
Material and labour for 75mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate ) as in plinth protection and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for anodised aluminium Ventilator/window/door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and directed.
S &F 3mm thick frosted glass, ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and as directed.
S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing all as per drawing complete all as specified and as directed.
S & F 150 mm aluminium, anodised, barrel tower bolt of extruded section and fixed complete all as specified and as directed.
S&F Butt hinges, medium weight cold rolled mild steel and fixed 75mm size complete all as specified and as directed.
S & F 250 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed complete all as specified and as directed.
S & F vitreous china wash down water closet (Pedestal pattern) EWC white incl plastic water closet seat cover and mild steel chromium plated or aluminium hinging device and connecting to 'P' or 'S' trap incl connecting flush pipe with flushing cistern of cat part No (FNS-WHT-40751P180UFSMZ) of jaquar or equivalent in parryware/ Hindware all as specified and directed.
S&F of CP 1.5m pipe health faucet cat part No (ALD-CHR-563) of Jaquar or equivalent in parryware/ Hindware all as specified and as directed.
Supply and fix wash hand basin, cat part No (JDS-WHT-25911) of Jaquar or equivalent in parryware/ Hindware vitreous China thin rim table top basin including cutting for and pinning in ends of brackets or erecting stand incl supply and fixing of waste couplings, waste pipe complete all as specified and as directed.
Supply and fix 15 mm bore fancy type single lever basin mixer chromium plated cast copper alloy with capstan head, long screwed shanks cat part No (OPP-CHR-15001PM) of Jaquar or equivelent in parryware/ Hindware all as specified and as directed.
Supply and fix looking mirror of size outer dia including bracket 500 mm swivel mirror cat part No. (CAN-CHR-1195N) of Jaquar or equivelent in parryware/ Hindware all as specified and as directed.
Supply and fix vitreous China urinals, Half stall type white (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
S& F of 15mm dia concussive push button taps of cast copper alloy, chromium plated screwed for iron pipe and fixed complete all as specified and as directed.
S&F Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum wt 60 gms) complete all as specified and as directed.
S & F in repairs 75/100 mm bore PVC (SWR) floor trap with grating incl jointing with solvent cement complete all as specified and as directed.
M&L Granite 18 to 20mm thick (table rubbed and polished) in steps,Jambs, Pillars, Windows, cills, platforms and like set in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade of Granite over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) all as specified and as directed. Note : (a) The Unit rate quoted is included for Demolition of old Stone Slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar
S&F for Rolled mild steel in staging for water tank Fe 410 -W (Gde- E- 250) quality-A staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffners, gusset plates, etc. complete all as specified and as directed.
S & F Rotational moulded Polyethylene (triple layered) water storage tank of 1000 liters capacity (cylidrical vertical threaded top cover) hoisted and fixed in position all as specified in SSR part I including all fitting and connecting to inlet and outlet pipes, tank nipple, elbow, union socket, reducer etc. complete all as specified and as directed.
S & F 25 mm dia CPVC gate valve screwed both ends for CPVC complete all as specified and as directed.
S & F chromium plated towel rail 20mm dia D type 60 cm long complete all as specified and as directed.
S&F in repair CP soap dish 100 mm x 100mm fixed with screw to wall complete all as specified and as directed.
S&F 20 mm dia of CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls / ceiling or laying in floors complete all as specified and directed.
S&F 25 mm dia of CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls / ceiling or laying in floors complete all as specified and directed.
S&F in Bib taps chromium plated 15 mm with fancy type with capstan head handle screwed down high pressure with crutch or butterfly handle ,screwed both ends for iron pipe or for unions complete all as specified and directed. Make : Cera/Jaguar/Ess Ess.
S&F angular stop valves cast copper screwed down high pressure fancy type screwed both ends for pipe or union fixed for 15mm bore complete all as specified and as directed.
S & F PVC connection 15 mm bore, 450 mm long complete with both ends unions complete all as specified and as directed.
Supply and fix 110mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall or laid in trenches complete all as specified and as directed.
Supply and fix 75mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall or laid in trenches complete all as specified and as directed.
Supply and fix PVC cowl 110 mm dia complete all as specified and as directed.
Supply and fix 110mm dia PVC bend any radius complete all as specified and as directed.
All as per item 56 above but 75mm dia complete all as specified and as directed.
S & F PVC (SWR) bends of any radius with access door for bore of pipe 75 mm complete all as specified and as directed.
All as per item No. 58 above but bore of pipe 110 mm with access door complete all as specified and as directed.
S & F PVC (SWR) junction single (single T) equal or unequal with access door for bore of pipe 110 mm complete all as specified and as directed.
Taking down window shutters of any description n exc 1.00 Sqm each complete all as specified and as directed.
M&L for rendering 10mm thick in CM 1:6 on fair faces of PCC block masonry work an internal surfaces , finished even and smooth without using extra cement complete all as specified and as directed.
Demolition of Brickwork or block masonry built in cement mortar all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work/stone masonry finished even and smooth without using extra cement complete all as specified and as directed.
S&F of Powder coated aluminium frame work for partition with one or more rebates incl Joining cleats,hooks, hangers, beadings,tower bolts,hinges, rubber gaskets etc, powder coating minimum thickness of powder coating 50 micron complete all as specified and as directed.
S&F using Water proof plywood of 9-10 mm thick both side decorative face of exterior grade as in cup board shutters, shelves and as in partition complete all as specified and as directed
Dismantling floors hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and as directed.
M&L for taking down of shutters exc 1.00 Sqm and n exc 2.00 Sqm each complete all as specified na as directed.
Supply and fix in repairs vitreous china squatting pan Orrisa pattern of size 580 x 440 mm white with "P" and "S" trap front or back inlet etc including provision of PCC (1:5:10) concrete complete all as specified and as directed
S&F PVC low level flushing cistern 10 liters capacity (exclusive of brackets), and connections to pipes and fixing of chain and pull, or lever,Joint between flushing pipe and socket of W.C. pan, if any complete all as specified and as directed.
Taking down steel water tubing and connections 15 mm dia complete all as specified and as directed.
All as per item No 72 herein before but 20mm dia complete all as specified and as directed.
M & L for Pre-cast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate set in cement mortar 1:4 as in cover slab including all necessary form work and removal of old. Exposed surfaces of concrete shall be finished even and smooth without using extra cement. (Note : Reinforcement shall be measured and paid separately under relevant items of this schedule). complete all as specified and as directed.
Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in soft soil complete all as specified and as directed
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for Chequered cement concrete tiles 30cm x 30cm x 25 mm thick with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors including screed bed or bedding layer of 15 mm thick CM 1 : 4 complete all as specified and directed
M&L for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-40 Grade over sand cushion with grey cement and no pigment complete all as specified and directed
M&L for kerb stone precast with PCC (1:2:4) type B1 using 20mm graded crushed stone aggregate finished even and fair without using extra cement complete all as specified and directed.
Removing excavated material n.exc 50 m and despositing where directed at a level n.exc 1.5 m above the starting point and complete all as specified and directed
Excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth ground, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone agg) as in foundation, filling and for mass concrete complete all as specified and directed.
S & F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. including necessary cutting, drilling, welding etc and bending to swan neck shape as required and drilling holes notching for wires etc conforming to Fe-410- W (Gde- E-250) quality- B complete all as specified and as directed.
M&L for 2mm Fibre glass reinforced translucent plain/corrugated sheeting of decided color with two corrugations side lap fixed with coach screws and washers in roof, wall etc complete all as specified and as directed.
Supply and fix 160mm dia PVC drainage pipe single socket in any length with proper joint fixed, laid in trenches complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in bed to drain pipes of 160 mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M&L for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in foundation/copings/benching of manholes including weathering rounded/chamfered angles and throating as directed including necessary form work. Exposed surfaces of concrete shall be finished even and smooth with out using extra cement complete all as specified and as directed.
Cutting into exisiting manholes for connecting new drains, making good to pipes and rendering ,cutting out existing benching and forming branch channel, halfround or 3/4 section in cement concrete1:2:4 type B-1 smooth finished and forming benching as required, internal dia of pipe150mm complete all as specified and as directed.
Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM 1:4 all as specified and as directed.
M&L for Providing, cement concrete Tpe B-0 1:2:4 (20mm graded agregate) in band complete all as specified and as directed.
M&L for Providing, brick bats for filling in sokage well complete all as specified and as directed.
Demolition Cement Concrete (un-reinforced) of any description in ground floors, pavings, etc. not exc. 150mm thickness (above or below ground level) and removing debris, etc. to outside MD/AF and, complete all as specified and as directed.
M & L for 75mm thick cement concrete 1:4:8 type D-2, using 40mm graded stone aggregates as in sub base of flooring etc. complete all as specified and as directed.
M&L 40 mm thick PCC 1:2:4 Type B-1 (using 20 mm graded crushed stone aggregate) as in flooring, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L100 mm thick, Cement concrete 1:2:4, type B2 using 40 mm graded stone aggregate as in pavings, hardstandings and similar work .
M&L non-skid colored ceramic joint free tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in flooring, set and jointed in neat cement slurry and pointed in white or color cement to match the tiles, laid over and including screed bed 15mm thick in cement mortar 1:6, complete all as specified and as directed.
Supplying and laying of CPVC 16mm dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Cutting grooves in brick/stone wall for 15mm/20mm dia pipe, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3, complete all as specified and directed.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated fancy type, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F vitreous china wash hand basin 550x400mm in size, white (flat back type) with waste fitting brass chromium plated 32mm dia, PVC waste pipe 32mm bore (dia) of suitable length, a pair of cast iron brackets duly painted/ erecting stand including cutting and pinning in ends, complete all as specified and as directed.
S& F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
M & L for grating doom 100 mm dia of PTMT (Minimum weight 25 gms) all as specified and directed.
M & L for PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified and directed.
S&F Vitreous china wash down water closet pan white colour (Pedestal Pattern) with'P' or 'S' trap and fixing bolts and making good to floor surfaces and white seat cover ISI marked with hinging devices with 'P' trap etc, complete all as specified and as directed.
S&F Gun Metal Globe/Gate Valve 15mm bore (dia) with iron wheel head, screwed both ends for iron pipe, complete all as specified and as directed.
S & F of Steel ventilator with top hung shutter including hinges, steel peg stay and glazing, complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.- 240 complete all as specified and directed.
S&F Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm 90gms/20mm-125gms) complete all as specified and as directed.
Taking down chowkat or frame of any description (without taking off shutter from the frame) not exc. 1.50 Sqm each, complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) plain color (ivory shade) consisting of frame made out of mild steel tubes for top & bottom rails of mild steel frame shall be covered with heat molded wood grain PVC ‘c’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail & bottom rail, paneling of wood grain PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles & rails with suitable 5.0mm thick x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mmx10mm (90°) and jointed together with solvent cement and fixing in the frame at site, complete all as specified and as directed.
S&F Aluminium handle 125mm long (weight not less than 90 gram), cast type, anodised, complete all as specified and as directed.
S&F of Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed.
M&L for three coats of white washing on walls including preparation of new plastered surface Complete all as specified and directed..
M & L Mild steel work as in handles of man hole cover slabs, rungs of man holes, straps and similar articles confirming to FE-290 Gde E-165 etc complete all as specified and as directed
M & L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M & L salt glazed stone ware drain pipes of internal dia 150 mm bore grade 'A' laid in trenches and jointed including concrete bed to drain hamching against the sides of pipe in cement concrete 1:3:6 type C-1 using 20 mm graded aggregate all as specified and directed.
M& L for pre cast cement concrete block masonary (1:3:6) type C-1 using 20 mm graded stone aggregate with soild blocks, not exc 10 CM in width set in CM (1:4) etc complete all as specified and directed.
S&F framed work as in doors or gates of angle,tubes or other section with gusset plates, rails, braces,guard bar etc., complete, to be prepared for hanging or sliding with and including hinges or steel hanging door fittings (exclusive of steel sheeting or other covering) and hanging; also fastening and fixing Fe 410 -W (Gde- E- 250) quality-A complete
Material and labour for glazed ceramic designer coloured tiles of size 300 X 200 X 7 mm thick as in vertical surface such as skirting / dado, set, jointed in neat cement slurry and pointed in white cement using pigment to match color of tiles incl 10 mm thick plaster in CM 1:3 complete all as specified & directed
Material and labour for machine cut cudappa stone slab 20-25 mm thick in repairs over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match to shade of slab including rubbing and polishing and 15 mm thick screed in cement mortar 1:4 complete all as specified complete
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and directed.
S&F sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm all as specified & directed
Supply and fixing in repairs PVC flexible Waste pipe 32mm dia all as specified & directed
S&F for 40 mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors, including cutting of walls and elbow/bend etc.
Taking down carefully copper/aluminum point wiring (light, fan,Power) complete fittings such as switches , ceiling roses pendents , regulators sockets light fittings etc and making good disturbed surface of wall, floors , roof etc all as specified and direcccted.
M & L Point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed cable 1100 volts grade FRLS with multistranded copper conductor drawn through and including PVC Conduit 20 mm dia medium grade and all accessories Concealed in walls / roofs / floors / ceiling etc., including fabricated steel terminal box made out of 1.60mm thick MS sheet suitable for fixing of and including modular plate as per number of switch modules flush mounted suitable for fixing modular switches,sockets,fan regulators etc.including modular plate cover of required size and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed (Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly One light point controlled by one way switch complete all as specified and directed for the following:- Make of cable- Plaza/ Poly cab/ Havells. Make of Conduit: Supreme/ Diplast/ Avon Plast.
All as per item No. 2 here in before but one fan point controlled by one switch .
All as per item No. 2 here in before but one 5 pin 6 Amps socket point controlled by one 6 Amps switch on independent board .
All as per item No. 2 here in before but one 5 pin 6 Amps socket point controlled by one 6 Amps switch on same board .
All as per item No. 2 here in before but wiring with 4 Sqmm and earth conductor of size 4 Sqmm for one 6 pin 16/6 Amps socket outlet point controlled by one 16 Amps switch on independent board complete all as specified and directed.
Supply & fixing modular type switch 6 Amps ,1way,1 module all as specified and directed. Make : Legrand/ Crab tree/ Anchor
Supply & fixing modular type switch 16 Amps ,1way,1 module all as specified and directed. Make : Legrand/ Crab tree/ Anchor
Supply & fixing modular type socket 6 Amps, 2/3 Pin combined 2 module all as specified and directed. Make : Legrand/ Crab tree/ Anchor
Supply & fixing modular type socket 6 A/16 Amps, 6 Pin combined 2 module all as specified and directed.Make : Legrand/ Crab tree/ Anchor
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body complete all as directed.Make : Legrand/ Crab tree/ Anchor
Supply & Fix sheet metal enclosure double door 240 volts AC,SPN distribution board 4 way painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN incomer and MCB SP/DP as out goings and complete with 100 Amps rated busbar ,neutral bar,earth bar connecting cable links with top and bottom removable gland plate complete with IP 43 protection all as specified and as directed. Make : Legrand/ L&T/ Indo Asian
Supply & fix MCB SPN 40 Amps 240V, 50 HZ AC suitable for 10 KA,"C" series complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian
Supply and Fixing of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white Aluminium extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . Test Report to be submitted from any govt of India approved lab , The luminaire and driver shall be BIS approved with "R" number mentioned will submitted at time of delivery,. 5 year Company warrenty certificate to be submitted at the time of delivery, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
Supply & fix MCB SP 6 to 32 Amps 10 KA,"C" series complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian
Supply and fixing Exhaust Fan 300 mm sweep, 230/240 volt AC single phase, heavy duty, 1400 RPM, corrosion less mild steel body of motor, including necessary cutting, making holes on stone/brick walls where required, fixing arrangement with MS pipe 350 mm dia of required length for protect reshape of stone masonry, suitable hold fast with necessary nut, bolts / screwswriting MES No with synthetic enamel paint all specified and directed. Make- havells /bajaj/ Almonard.
M&L submain wiring with two single core PVC insulated multistranded flexible copper conductor 1100Volts grade (FRLS) cables 4 sqmm and 1 run 4 Sqmm PVC insulated multistrand copper conductor cable (FRLS) of green colour for continious earthing drawn through PVC surface/concealed PVC conduit of suitable size and with all accessories all as all as specified and directed. Make:- Havells/ Polycab/ Plaza ( Note: Three runs of 4 sqmm copper conductor and one run of surface PVC conduit of suitable size with all necessary fixing accessories and making good disturbed surface shall be measured as one length.)
M&L submain wiring with two single core PVC insulated multistranded flexible copper conductor 1100Volts grade (FRLS) cables 1.5 sqmm and 1 run 1.5 Sqmm PVC insulated multistrand copper conductor cable (FRLS) of green colour for continious earthing drawn through PVC surface/concealed PVC conduit of suitable size and with all accessories all as all as specified and directed. Make:- Havells/ Polycab/ Plaza ( Note: Three runs of 1.5 sqmm copper conductor and one run of surface PVC conduit of suitable size with all necessary fixing accessories and making good disturbed surface shall be measured as one length.)
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bounded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation complete all as specified and directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit, complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Supply and fixing building security/ LED street light fitting 36 Watt, 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete.Make: Philips/Bajaj/CG
Supply and fix street light bracket fabricated from galvanised iron pipe medium grade 32 mm dia of length 1 mtr bent to shape with socket and reducers as required suitable for fixing on PCC poles or on wall surface at any height etc and including suitable clamps -02 Nos with nuts,bolts & washers complete all as specified and directed.
Taking down of GI Earthing of any type complete all as directed.
Material and labour for well burnt class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material to out side MD. (iv) Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Material and labour for GI pipe 40 mm dia"light grade " complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection etc complete all as specified and directed
Material and labour for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 30 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.
Material and labour in repair for 2 core 6 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole etc, complete all as specified and directed. Make: Havells/ Polycab/ RPG Asian
Supply and fixing fedder piller box outdoor type of suitable size and made out of MS sheet and mounted on angle iron four legs of suitable size and height front and back opening double door with proper locking arrangement weather proof painted with two coat of synthetic enamelled paint over a coat of red oxide primer and grouting in ground with suitable PCC and comprising of the following :- (a) MCB SPN 63 A, 230 V- 01 No. (b) Two strip Copper bus bar 100 A- 01 Set (c) MCB SPN 32 A , 415 V -03 No
Supply & Fix GI tubing medium grade of size 50 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified directed.
Supply & Fix GI tubing medium grade of size 25 mm bore with all fittings on wall complete including cutting and thereading all as required at site complete all as specified directed.
Supply & Fix GI tubing medium grade of size 20 mm bore with all fittings on wall complete including cutting and thereading all as required at site complete all as specified directed.
Supply and fix stop valve, cast copper alloy 50 mm bore screwed down high pressure complete all as specified and directed.
M&L Gun metal globe or gate valves with iron wheel srewed both end for iron pipe and fixes of size 25 mm complete all as specified and directed.
S&F PVC float valve assembly 25 mm bore complete all as specified and directed.
Material and labour for DI fittings/specials 100 mm to 300 mm dia suitable for spigot and socket end or flanged end such as bends (any type, radius and angle) tapers any type ( straight, bend, increasing, decresing ordouble socket etc.) Tee pieces single branch."Y" junction, double branch, cross, collars, caps and plugs, connecting pieces (any type) and tesing complete all as specified and directed.
M&L for construction of PCC block walling valve pit of size 600mmx 600mm x600mm(internal dimension) with precast cement concrete block of PCC 1:3:6 type-C-1 using 20mm graded stone aggregate and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and incl 40x40x6 mm mild steel angle iron frame and 3mm thick MS sheet cover thickness not less then 3mm with locking arrangement and 1 No 50 mm size 4 level lock with key in duplicate incl painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide prime complete all as specified and shown on drawing complete all as specified and directed.
Cutting/drilling the existing Cast Iron/Ductile Iron pipes lines of 100 mm dia, in position for inserting of new Tee, branches etc complete all as specified and directed.
M & L for Cutting/drilling the existing DI pipes lines 100 mm dia, in position for inserting of water meter and Sluice valve, branches etc including excavation, returning filling in Removal , jointing , complete all as specified and directed. Note :- An amount of Rs 8923.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/s BHOOMI ELECTRICALS (BID ID -3132389)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .