Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 CrAccepted-AOC | ₹15.3 Cr Quoted ₹15.4 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹15.4 CrRejected-Finance | ₹15.4 Cr | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹15.8 CrRejected-Finance | ₹15.8 Cr | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹16.4 CrRejected-Finance | ₹16.4 Cr | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹16.5 CrRejected-Finance 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹16.5 Cr | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹16.5 Cr
EMD Value
₹11.5 L
Closing Date
7 Dec 2023, 6:00 pmClosed
CE Bathinda Zone
HQ Chief Engineer Bathinda Zone Bathinda Mil Stn - 151004
PROVN OF KLP ACCN UNDER GE (P) BATHINDA (Job No MWP/SWC-02/2021-22)
2023_MES_624341_1
CE BTZ/BTD/TOKEN-10 OF 2023-24
Open Tender
Civil Works
730 days
Bathinda
As per NIT
9 documents required · 9 mandatory
₹3,000
GE (P) Bathinda
₹11.5 L
Yes
26 Dec 2023
20 Oct 2023
11 Dec 2023
20 Oct 2023
7 Dec 2023
24 Nov 2023
Amount
Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I
Sch 'A' Sec - II, (INTERNAL ELECTRIFICATION WORKS)
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
All as per above Srl item No. 03 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge.(switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
All as per above Srl item No. 03 but for one socket out let 5 Amps point controlled by one switch (on independent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
Material and labour for concealed Point wiring for one light point controlled by two Nos- two way switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM(1:3), including fixing of switches complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box one for modular socket and one for Motor Starter Switch (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (Motor Starter Switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate).
Supply only modular switch 6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.
Supply only modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.
Supply only modular switch 6Amps, single pole, two way (1 module) complete all as specified and as directed by Engineer-in-charge.
Supply only modular Bell Push switch, 6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.
Supply only modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.
Supply only modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.
Supply only modular Socket outlet multipurpose type 25 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.
Supply only modular Motor Starter Switch, 25 Amp (2 module) complete all as specified and as directed by Engineer-in-charge.
Supply and fixing electric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection complete all as specified and as directed by Engr-in-charge.
Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, 240 volts, 5/6 Amp complete all as specified and as directed.
Supply and fixing Batten holder polycarbonate cased body (B22 base), top line series, with back plate complete all as specified and as directed.
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 450mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 250 Amp rated bus bar) VTPN, 4 Way 415V, suitable for mounting MCCB/MCB, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCCB/MCB shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) TPN, 4 Way 415V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 4 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘B’ curve suitable for 415 volts AC supply, 25 to 63 Amps, TP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 415 volts AC supply, 6 to 32 Amps, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 6 to 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 1 to 5 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing blanking plate suitable for any type of DB complete all as specified and as directed by Engineer-in-charge.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 4 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (06 run i.e 4 runs for main 3 phase and neutral, 02 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 32mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Six runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Supply and fixing LED tube light fitting polycarbonate housing 1 x 18/20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED light fitting 1 x 10 Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED Bulkhead fitting 1 x 10 Watt, complete with Standard LED lighting fixture with extruded polycarbonate housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : <15%. (f) IP rating : IP-65. (g) CCT : Minimum 5400K (h) Polycarbonate housing white coloured (j) LED Driver of the same make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection minimum 2.5 kV. (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing surface mounted complete fitting with separate electronic driver and high brightness LED 34/36 Watt flat panel of size 600x600mm, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting and all accessories including fixing material with following specifications and all as directed:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP20. (g) CCT : 6500K (h) CRI : Morethan 80 (j) CRCA pre coated housing. (k) LED Driver of the make as of the luminaire. (l) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection minimum 3 kV. (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED ceiling light fitting with wide light window for maximised glare free output, suitable for ceiling cutout 595x595mm modular grid ceiling finishes complete fitting with separate electronic driver and high brightness LED 34/36 Watt flat panel of size 600x600mm, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting and all accessories with following specifications and all as directed:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP20. (g) CCT : 6500K (h) CRI : Morethan 80 (j) CRCA pre coated housing. (k) LED Driver of the make as of the luminaire. (l) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection minimum 3 kV. (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing High bay beam LED light fitting of 50 Watt, specifically designed heat sink for long life vertical high bay/medium LED luminaries complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy including fixing on wall/roof with help of suitable GI clamps, nut bolts/fastners, pendant of suitable length and washers etc, the luminaries shall be monolithic construction totaly enclosed dust and water proof with minimum IP 65 protection as per IS-10322 (1982, Part-I) with latest amendments and input voltage range 140-300V, AC frequency 50-60Hz, PF should be more than 0.9 with total Harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fitting should be provided with 10KV Surge protection, Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from 10 degree centigrade to 50 degree centigrade and humidity level 10% to 90% RH. LED Driver of the make as of the luminaire. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection, cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report.complete all as specified and as directed.
Supply and fixing LED PIT/Trench light fitting 1x20 Watt including LED tube specially designed for service pit. The system wattage of fitting should not be more than 20 watt, plus minus 10%, Surge protection of minimum 2KV, PF should be more than 0.9 , cool white colour, Total Harmonic distoration THD less than 15%, The efficiency of LED luminaries system shall be more than 100 lumens per watt, input voltage range 140-300V, AC frequency 50-60Hz, CRI : Morethan 80, corelated colour should be minimum 6000 degree kelvin icluding fixing arrangements and fixing material complete all as specified and as directed.
Material and labour for Pressed steel powder coated sunken terminal box of size 100mm x100mmx50mm concealed in wall, including inner and outer plates (cover plate) suitable for fixing and including modular type (1 module) 2 pin TV antenna connection socket outlet round flush type duly marked with symbol of TV and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed.
Material and labour for concealed wiring for telephone connection complete with PVC insulated sheathed cable with copper conductor having single strand of 0.4 mm dia twin core (one pair) taped for telephone wiring drawn through PVC conduit complete all as specified and as directed. (Telephone connection socket outlet and terminal box, conduit with fittings shall be measured and paid separately under appropriate item of BOQ).
Material and labour for Pressed steel powder coated sunken terminal box of size 100mm x100mmx50mm concealed in wall, including inner and outer plates (cover plate) suitable for fixing and including modular type (1 module) telephone connection socket outlet flush type duly marked with symbol of telephone and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed.
Material and labour for concealed in wall rigid non matallic PVC conduit 20mm dia (medium duty, ISI marked) for telephone wiring, cable TV etc inclusive of all fitting & accessories such as tees, bends, elbow, reducer, junction box, pipe hooks etc, bell mouth tube ends including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.
Material and labour for concealed in wall rigid non matallic PVC conduit 25mm dia (medium duty, ISI marked) for telephone wiring, cable TV etc inclusive of all fitting & accessories such as tees, bends, elbow, reducer, junction box, pipe hooks etc, bell mouth tube ends including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.
Material and labour for concealed Flame proof Point wiring for light/fan points (using red, black and green colour wires as colour coding for single phase circuits) complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) for main point and for continues as earth wire connected to earth dolly etc. (Phase, netural and earth wire) drawn through and including ERW rigid conduit stove enamelled conduit with all flame proof fittings and all flame proof accessories (duly tested by CMRI) i.e. pipe bend, union socket, reducer, elbow, pipe hook, connectors, junction box, insepction elbow, GI sunken terminal box with 3mm thick bakelite laminated hylem sheet top cover etc, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. Note :- (i) Swicth, MCB and DB shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing CMRI certified flameproof 1x16 Watt LED tube light fitting, well glass luminaire suitable for RF LED lamp, recommended for Gas/Vapour group of IIA & IIB and zone 1 & 2, IP65 protection, Epoxy finish LM6 die cast aluminium housing with heat resistant toughened glass, including inbuilt electronic driver, 2 kv surge protection, internally pre-wired, LED lamp, connector block etc complete with all other accessories including making electric connection connecting with twin core twisted flecible copper conductor cable and connector block, tobe fixed flush to wall/ceiling surface complete all as specified and as directed by Engineer-in-Charge. Specification for LED luminaire (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP65. (g) CRI : Morethan 80 (h) CCT : 6500 K. (i) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended)
Supply and fixing CMRI certified flameproof exhaust fan of size 305mm, single phase, with 1440 RPM , 0.25 HP, 1120 CFM, complete with all other accessories including making electric connection connecting with twin core twisted flecible copper conductor cable and connector block, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Subtotal
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)
Sch 'A' Sec - III (Part-II), (INTERNAL WATER SUPPLY WORKS)
Supply and fixing 15 mm bore Angle stop valve with flange, cast copper alloy chromium plated, fancy type, screwed down high pressure with on/off handle screwed end for iron pipe or for unions and fixed complete all as specified and as directed.
Supply and fixing 15 mm bore two way Bib cock/Angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed end for iron pipe or for unions and fixed complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “ROAD, PATH, CULVERT, HUME PIPE, HARDSTANDING AND GENERATOR PLAT FORM WORKS" as listed in Schedule ‘A’ Section -IV (Part-I)
Sch 'A' Sec - IV (Part-II), (ROAD, PATH, CULVERT, HUME PIPE, HARDSTANDING AND GENERATOR PLAT FORM WORKS)
Supply and laying/fixing 60 mm thick (M-35 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and no pigment, any shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed.
Supply and laying factory made kerb stone of M-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed.
Material and labour for Thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed.
Supply and fixing metal tubular Delineator made out of ABS round body fitted with 02 Nos 65mm dia highly reflective reflectors made out of PMMA and mounted on 45/50mm dia mild steel pipe 600mm height duly podwer coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25mm wide strips with anti theft steel net for reflector protection including embedding in PCC (1:2:4, type B1) block size 150x150x300mm including necessary earthwork complete all as specified and as directed.
Supply and fixing road stud cat eye solar reflective type of metal body alloy of size 100mmx 100mm x 20 mm with PMMA striplens reflector and fixing the same on road surface by applying approximately 100 gm Epoxy mixture and placing the cat eye without applying exessive pressure and additional fixed with zinc plated steel nail of suitable size as per manufacturers instructions at the centre of cat eye complete all as specified and as directed.
Supply and fixing convex safety mirror of 800 mm dia made from long life poly carbonate with strong impact resistant and shattle proof fitted with a sun shield or protective hood of colour as approved, provided with suitable MS pipe post (1.5m height excluding embedded portion) duly coated with synthetic enamel paint over a coat of red oxide primer, including embedding in PCC (1:2:4, type B1) block size 450x450x450mm including necessary earthwork complete all as specified and as directed.
Material and labour for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and filling the Joints with and including bitumen and sand (1:3) by weight ( Thickness of concrete slab in 100mm) complete all as specified and as directed.
Material and labour for Forming Contraction (Dummy) joints 30mm deep x 10mm wide, and filling the Joints with and including bitumen and sand (1:3) by weight complete all as specified and as directed.
Material and labour for Forming Construction joint 25mm deep x 10mm wide and filling the Joints with and including bitumen and sand (1:3) by weight complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “AREA DRAINAGE WORKS)" as listed in Schedule ‘A’ Section -V (Part-I)
Sch 'A' Sec - V (Part-II), (AREA DRAINAGE WORKS)
Material and labour for Pre-cast factory made RCC drain of size and shape as directed by GE alongwith male and female ends for proper joining, made of 75mm thick RCC M-30 using 20mm graded aggregate, duly embeded two Nos socket for hoisting including form work etc, hosting and placing at site and jointed in CM (1:4) to form uniform length and fair finish to drain upto 80cm girth (width measured @ Avg of inner and outer girth) complete all as specified and as directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid separately under respective item of Sch.
Subtotal
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS" as listed in Schedule ‘A’ Section - VI (Part-I)
Sch 'A' Sec - VI (Part-II), (SEWAGE DISPOSAL WORKS)
Material & Labour for Precast M-30 factory made manhole cover, set in CM (1:4) including necessary form work complete all as specified and as directed (Reinforcement and MS handle shall be measured and paid separately under respective item of Sch).
S & F PVC coated factory made MS rungs of size 263mm (L)x165mm (W), overall length 691mm made out of 16mm dia round bar with overall thickness after coating as 25mm fixed in RCC while casting complete all as specified and as directed.
Supply and laying DWCPE (SN8) drain pipes 150mm nominal dia as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch
Supply and laying DWCPE (SN8) drain pipes 200mm nominal dia as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch.
Material and labour for jointing of Steel water tubing of 50 mm bore (for submersible pump) dia ISI marked heavy grade galvanised including tube fittings Viz Tees, Socket bends elbows, union nipple, clamps etc screwed and socketed joints complete all as specified and as directed.
Supplying, installing, commissioning and testing of Non-clog vertical Submersible pump for handling sewage water and having discharge of minimum 141 LPM and 21M head, 415 Volts, 50 Hz, 2900 RPM, 'F' Cl insulation, IP 68 protection, 40 degree centigrade operating temperature with CI Impellor, CI motor body, CI pump housing, stainless steel shaft and delivery pipe size of 50mm including hoisting submersible sewage pump into sewage collection tank using suitable stainless steel heavy duty (Gde 316) chain and anchoring with hook on top of sewage tank with necessary nuts, bolts, washers etc complete all as specified and directed.
Supply and fixing PVC Insulated overall sheathed 3 core submersible flat copper cable 1100 volts grade 2.5 sqmm including PVC conduit of suitable size with accessories all as specified and directed.
Supply and fixing 50 mm bore cast iron body non return valve (NRV), confirming to IS 5312 (ISI marked), both flanged ends in swing type and drilled, including jointing material such as nuts, bolts, washers and rubber sheet insertion at both ends etc complete all as specified and as directed.
Supply, installing, commissioning and testing of factory made LT panel board (CPRI approved) (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size, outer shell made out of 3.15 mm thick CRCA epoxy powder coated sheet and inner shell made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Four Pole, Copper bus bar 50 Amps
MCB 20 Amps, TP, C series, 10 KA, 415 V AC supply - 01 No (Incoming)
MCB 10 Amps, TP, C series, 10 KA, AC supply - 02 No (for DOL starters) (Outgoing)
Power Contactor, 9A - 02 No (For DOL Starters)
Overload Thermal relay (4 - 6A) - 02 No (For DOL Starters)
Indicator LED for ON and OFF Indication - 02 No (For DOL Starters)
Push button START & STOP - 02 No (For DOL Starters)
Rotary Switch 3 Phase - 01 No (For DOL Starters)
Ultra sonic Non-contact type water level sensor (for sewerage water) with PLC - 01 No
Single phase preventor - 02 No
Indicating lamps set RYB - 01 Set of three
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Subtotal
Lump sum price worked out by the tenderer for “SECURITY FENCING AND GATE WORKS" as listed in Schedule ‘A’ Section - VII
Lump sum price worked out by the tenderer for “ EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - VIII (Part-I)
Sch 'A' Sec - VIII (Part-II), ( EXTERNAL WATER SUPPLY WORKS)
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 100mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 150mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supply and fixing cast iron sluice valve 150 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, steel spindle, CI gate with brass ring, iron wheel handle, suitable for CI/DI pipe line, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve 80 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, steel spindle, CI gate with brass ring, iron wheel handle, suitable for CI/DI pipe line, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Material and labour for Construction of brick masonary valve pit chamber size 120 X120 X120 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
Material and labour for Construction of brick masonary valve pit chamber size 90 X90 X90 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
Material and labour for Construction of brick masonary valve pit chamber size 75 X75 X75 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
Supply and fixing DI fitting upto 200 mm bore pipe line for reducing/bends (any type radius and angle) tapers any type, straight, bend, increasing decreasing or double socket extra Tee pieces single branch Y 'Junction' double branch cross collers cap etc complete all as specified and as directed. Note:- Make of DI fittings shall be same make as DI pipe or as per recommendation of DI pipe manufacturer.
Material and labour for run lead joints suitable for 80mm bore CI/DI spigot and socketed pipe and fittings including spun yarn complete all as specified and as directed.
Material and labour for run lead joints suitable for 100mm bore CI/DI spigot and socketed pipe and fittings including spun yarn complete all as specified and as directed.
Material and labour for run lead joints suitable for 150mm bore CI/DI spigot and socketed pipe and fittings including spun yarn complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - IX (Part-I)
Sch 'A' Sec - IX (Part-II), (EXTERNAL ELECTRIFICATION WORKS)
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing energy efficient LED street light fitting of 45W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, fixing the light fitting with and including bracket made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP65. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED Post Top light luminaire of 15W, 230 volts AC outdoor type, decorative design, Glare-free and better uniformity, for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete fitting with all accessories and LED lamp, fixing on and including GI pipe light grade of size 25mm dia and length 1.5 mtr, embeded in PCC block of size 0.3x0.3x0.5m made with PCC (1:2:4) type B-2 using 20 mm graded crushed stone aggregate, including making electric connection with suitable size of wire, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficiency of luminaire should be minimum 100 lumen per watt. (b) Input voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10*C to plus 50*C (d) Power factor : Minimum 0.95 (e) THD : Max 10% (f) CRI : More than 70 and CCT : 5700K (g) IP rating : IP 65 (h) IK rating : minimum IK 07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should e complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10kV (inbuilt +extended) (m) Lens - High Efficiency wide angle lens. (n) BIS approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing three core core (3x1.5sqmm) flexible flat/round cable, copper conductor multistranded, PVC insulated and overall PVC sheathed, 1100 volt, drawn through LT steel tubular poles or drawn through GI pipe along PCC pole for connection to street light from junction box to light complete all as specified and as directed. Note :- GI Pipes if required same shall be measured and paid seperately under respective item.
Supply and fixing cable junction box of minimum Size 210mm x 155mm x 92mm or any other higher size complete with fixing accessories. Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. The polycarbonate junction box shall be environment frinedly, recyclable, UV resistant, halogen and silicon free, anti acid and anti corrosive. The junction box knock out on four side wall and following specifications and all as directed by Engr-in-Charge :- (a) The junction box shall be rated for degree of IP 66 (ingress protection) in accordance with IEC 60529. (b) The gasket material shall be polyurethane or silicon and gasket shall be internally embedded and 63 A four pole terminal stud. (c) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60670-22, IEC-60670-22, IEC 60670-2 to 5 and grey color according to RAL 7035. (d) The manufacturer of junction box shall submit a copy of IEC certificate and glow wire test for 960 degree. (e) Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. (f) The impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK08. (g) Junction box with stud type terminal, 63A flame retardant one number 6 Amp MCB SP 10KA (h) Manufacturer should submit routine test certificate for junction box. (j) Clamps and screws for fixing of junction box shall be made of SS-304
Material and labour for cable route indicator post 900mm long made of precast cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate, rounded tops as directed and embeded in ground of size 350x150x450mm below ground and 300x100x450mm above ground, applying two coats of cement base paint on plastered surface including writing letters (like LT/HT UG cable, __ feeder etc.) with synthetic enamel paint in brown colour in suitable size including earth work and form work complete all as specified and as directed.
Supply and fixing Cable route indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 150 mm dia and 8mm thick with provision of 500 mm long (minimum) single leg/stand of angle iron 40x40x5 mm, welded/riveted on back side of plate, fixed and grounted in position with with PCC (1:3:6) type C-1, using 20 mm graded stone aggregate block of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing of automatic street light control switch with infrared sensor based Nature Switch & voltage monitoring system (VMS). Nature switch operation should be based on Natural Light Lux level. Required illuminance level for Switching ON is ≤ 30 Lux and for switching OFF ≥ 10 Lux. The Sensor should also have pert night operation facility of min. 4 hrs. to max 12 hrs. VMS should have Adjustable over & under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The sensor & VMS along with suitable Power Contractor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Terninate proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. sensor & VMS By-Pass option) with 3nos. Contractors, 3 Nos incoming MCBs & 3 Nos outgoing MCBs of 16-20 Amps each & Circuit wiring (Copper) of min. 10 sqmm complete all as specified and as directed by Engineer-in-Charge.
Sand cushioning, with dry and clean river fine sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved sand free from vegetations, grass and other deleterious substances shall be used.
Material and labour for boring of holes under main road pavement, hard standing or any other situation by manual mean for accommodate 40mm to 100mm bore GI tube (light grade) in the drilled holes, including returning, filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed. Note ; (GL pipe and cable shall be measured and paid separately)
Supply, installing, commissioning and testing of factory made LT panel board (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size, outer shell made out of 3.15 mm thick CRCA epoxy powder coated sheet and inner shell made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Four Pole, Aluminium bus bar 400 Amps
MCCB 250 Amps, Four pole, adjustable thermal magnetic protection, 25 KA, 415 V AC supply - 01 No (Incoming)
MCCB 80 Amps, Four pole, adjustable thermal magnetic protection, 16 KA, 415 V AC supply - 02 No (Outgoing)
MCCB 63 Amps, Four pole, adjustable thermal magnetic protection, 16 KA, 415 V AC supply - 02 No (Outgoing)
MCB 32 Amps, Four pole, 10 KA, C-series, AC supply - 02 No (Outgoing)
MCB 10 Amps, SPN, 10 KA, C-series, AC supply - 02 No (Outgoing)
Indicating lamps set RYB - 01 Set of three
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installing, commissioning and testing of factory made LT panel board (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size, outer shell made out of 3.15 mm thick CRCA epoxy powder coated sheet and inner shell made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Four Pole, Aluminium bus bar 150 Amps
MCCB 80 Amps, Four pole, adjustable thermal magnetic protection, 16 KA, 415 V AC supply - 1 No (Incoming)
MCB 20 Amps, Four pole, 10 KA, C-series, AC supply - 02 No (Outgoing)
MCB 10 Amps, Four pole, 10 KA, C-series, AC supply - 01 No (Outgoing)
MCB 32 Amps, SPN, 10 KA, C-series, AC supply - 04 No (Outgoing)
MCB 16 Amps, SPN, 10 KA, C-series, AC supply - 04 No (Outgoing)
Indicating lamps set RYB - 01 Set of three
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installing, commissioning and testing of factory made LT panel board (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size, outer shell made out of 3.15 mm thick CRCA epoxy powder coated sheet and inner shell made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Four Pole, Aluminium bus bar 100 Amps
MCCB 63 Amps, Four pole, adjustable thermal magnetic protection, 16 KA, 415 V AC supply - 1 No (Incoming)
MCB 25 Amps, Four pole, 10 KA, C-series, AC supply - 02 No (Outgoing)
MCB 16 Amps, Four pole, 10 KA, C-series, AC supply - 02 No (Outgoing)
MCB 16 Amps, SPN, 10 KA, C-series, AC supply - 03 No (Outgoing)
Indicating lamps set RYB - 01 Set of three
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installing, commissioning and testing of factory made LT Bus bar chamber/Feeder pillar box (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size, outer shell made out of 3.15 mm thick CRCA epoxy powder coated sheet and inner shell made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Four Pole, Aluminium bus bar 50 Amps
MCB 32 Amps, TPN, 10 KA, C-series, AC supply - 01 No (Incoming)
Indicating lamps set RYB - 01 Set of three
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply and fixing factory made LT Bus bar chamber (wall mounted for 415 volts, 3 phase, 4 wire AC supply) cubical type of size not less than 300mm x 200mm x 100mm, made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, front opening with single door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar of capacity 32Amp shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator, box shall be mounted on wall with 2 Nos steel fasteners 10mm dia 100mm long and making good the disturbed surface complete including all connections incoming / out going all as directed by Engineer-in-charge.
Supply and fixing factory made LT Bus bar chamber (wall mounted for 240 volts, 1 phase, AC supply) cubical type of size not less than 200mm x 150mm x 100mm, made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, front opening with single door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The double Pole bus bar of capacity 32Amp shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator, box shall be mounted on wall with 2 Nos steel fasteners 10mm dia 100mm long and making good the disturbed surface complete including all connections incoming / out going all as directed by Engineer-in-charge.
Supply, installing, commissioning & testing energy efficient of transformer suitable for 160 KVA step down pole mounted outdoor type 11/0.433, 3 phase, 50 Hz AC, IS: 1180-2014 (level 2) ISI marked, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connected on LV side in accordance with vector symbol Dyn-11 with neutral brought out on LV side with for earthing and having tapping on HV side for constant out put so as to alter/vary secondary voltage by (Tapping range + 5 % to - 10% in equal step of 2.5 % ) changed by means of manually operated " off load" taps changing gear. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories. The limit of temperature rise after continuous full load run as specified in IS-1180 (Part-I) 2014 and BEE Certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent. The transformer shall be comprised with the following fittings and accessories
(a) Oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) Silica gel breather with connecting pipe, first fill of dehydrating agent. (c) Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) Air release valve plug (e) One cable box on LV side (Secondary) consisting of 04 Nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) Explosive vent (g) 01 No 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) Thermometer pocket on tank cover (j) 04 Nos plain solid CI detachable rollers (k) Two Nos Earthing terminals marking plate. (l) Rating plate and terminal marking plate (m) Extra bushing for neutral outside the cable box brought out on LV side. (n) First filling of oil conforming to IS and tested upto 60 KV dielectric strength (o) Lifting lugs (p) Oil drain valve with plug (q) One cable box on HV side (Primary) consisting of 01 cable gland suitable for reception of taking in HT cable including gland joints complete all as specified (r) Hand hole of sufficient size to assess interior of tank (s) Dehydrating breather with first filling of Dehydrating agent (t) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strip. (u) Rating plate with terminal marking plate (v) Inspection cover.
Subtotal
Lump sum price worked out by the tenderer for “SUMMER APPLIANCES, WATER SUPPLY FOR WATER COOLER, DESERT COOLER, AIR CONDITIONING AND HOT WATER APPLIANCES WORKS" as listed in Schedule ‘A’ Section - X (Part-I)
Sch 'A' Sec - X (Part-II) , (SUMMER APPLIANCES, WATER SUPPLY FOR WATER COOLER, DESERT COOLER, AIR CONDITIONING AND HOT WATER APPLIANCES WORKS)
Supply, installing, commissioning and testing frost free refrigerator electric driven single phase 220 volts, AC 50 Hz, 210 ltrs or next higher capacity with BEE approved, minimum 3 star rating single door, stablizer free operation, Inverter Technology, R600a Refrigerant, tempered glass self, deodorizer and with fruit & vegitable drawer complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply, installing, commissioning and testing Water Cooler fully stainless steel, electric driven single phase having approx storage capacity of 40 Ltr and nominal cooling capacity of 40 Ltr per hour with float valve and inlet PVC connection pipe of size 15 mm dia and 600 mm long of good quality complete with both ends CP nuts including electric connection through Voltage stablizer complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply, installing, commissioning and testing Water Cooler fully stainless steel, electric driven single phase having approx storage capacity of 80 Ltr and nominal cooling capacity of 40 Ltr per hour with float valve and inlet PVC connection pipe of size 15 mm dia and 600 mm long of good quality complete with both ends CP nuts including electric connection through Voltage stablizer complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA with wall mounting bracket complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA with wall mounting bracket complete all as specified and as directed.
Supply and Installation of Desert cooler of size 26 x 26 x 33 inch or next available higher size, electric driven single phase 230 volts steel body having nominal air flow capacity of 4000 Cu M per hours, factory made GI sheet body 18 SWG and side panells of 22 SWG, water sump capacity not less than 40 ltrs, including water pump submesible type of suitable capacity ISI marked, complete including electric connection complete all as specified and as directed. Note (a) : Sufficient length of 3 core PVC sheathed round copper cable size 23/.0076 to enable fixing in to plug point shall be provided by contractor. (b) GI Pipes, float valve, stop valve, PVC connection shall be measured and paid seperately under respective item. (c) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer. (d) Serial Number as issued by Engr-In-Charge of cooler and GE Office name shall also be written on cooler with red colour permanent marker or paint, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply, installing, commissioning and testing of electric water heater (Geyser) storage type ABS body of capacity 25 litre, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection for Hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable, 04 no Nut bolt grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 2.5 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 20mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Subtotal
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS" as listed in Schedule ‘A’ Section - XI (Part-I)
Sch 'A' Sec - XI (Part-II) , (EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS)
Surface excavation not exc 30 cm deep and getting out in soft/ loose soil complete all as specified and as directed.
Subtotal
BANSI BUILDER AND CONTRACTORS PVT LTD
ENGINEER CONSTRUCTION PVT. LTD.
A.V BUILDERS
A S CONSTRUCTION COMPANY
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid