Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹10.9 L+₹3.6 L (48.6%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
19 Feb 2025, 6:00 pmClosed
Offg GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR MAINT OF EXTERNAL ELECTRIC SUPPLY, LT CABLE, LT PANEL AND CONNECTED ITEMS IN TECH AREA, WAR MEMORIAL COLONY AND MES COLONY UNDER GE I R AND D KANPUR
2025_MES_693522_1
8413/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kanpur
As per Appx A of NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹24,000
29 Mar 2025
16 Jan 2025
26 Feb 2025
16 Jan 2025
19 Feb 2025
31 Jan 2025
16 Jan 2025 - 30 Jan 2025
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays and for rerouting of cables.
All as per item No 1.00 but depth exc 1.5 mtr but not exc 3.00 mtr
Returning filling, in including spreading, leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
M&L for pre cast cement concrete ( 1:4:8) type D2 using 40mm graded stone aggregate for oundation filling of poles as mass concrete.
M&L for pre cast cement concrete ( 1:3:6) type C2 using 40mm graded stone aggregate for foundation filling of stays.
Demolition of cement concrete (un-reinforced) in ground, floors or pavings not exceeding 15 cm thick below or above ground level complete all as specified.
M & L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in floor / hard-standing, surface finished even and smooth without using extra cement to match with the existing surface complete all as specified.
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection cable & pipe upto 80 mm bore complete all as specified. Note: Depth of bore shall not be more than 1 Mtr from original ground level.
Disconnecting electrically and taking out old unserviceable LT UG cables any type and any size all as spfd and directed.
Taking out carefully unserviceable LT UG cable of size 6 Sqmm to 300 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing complete all as directed. ( Note: Earth work, sand, bricks will be measured and paid separately)
Supply and laying in trenches or fixing to wall/pole or passing through pipe in replacement of 1100 volts grade heavy duty cable with XLPE insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 16 sq. mm nominal cross section 2 core in service connections all as required and directed. Make of cable : Gloster/Havells/ Paragon/ Grandlay/Kalinga. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
All as per srl item No 14.00 but cable of size 10 Sqmm 2 core.
Supply and laying in trenches or fixing to wall/pole or passing through pipe in replacement of XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
All as per srl item No 16.00 but cable of size 10 Sqmm 4 core.
All as per srl item No 16.00 but cable of size 16 Sqmm 4 core.
All as per srl item No 16.00 but cable of size 35 Sqmm 3.5 core.
All as per srl item No 16.00 but cable of size 50 Sqmm 3.5 core.
All as per srl item No 16.00 but cable of size 70 Sqmm 3.5 core.
All as per srl item No 16.00 but cable of size 95 Sqmm 3.5 core.
All as per srl item No 16.00 but cable of size 120 Sqmm 3.5 core.
All as per srl item No 16.00 but cable of size 150 Sqmm 3.5 core.
All as per srl item No 16.00 but cable of size 185 Sqmm 3.5 core.
All as per srl item No 16.00 but cable of size 240 Sqmm 3.5 core.
All as per srl item No 16.00 but cable of size 300 Sqmm 3.5 core.
S&F in replacement of cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5/4 core.
All as per item No 28.00 but for 25 to 50 Sqmm size.
All as per item No 28.00 but for 70 to 150 Sqmm size.
All as per item No 28.00 but for 185 to 300 Sqmm size.
Dismantling from insulators and taking down ACSR conductor any size from HT/LT over head lines and depositing to MES store yead.
Dismantling insulator any type and any size from LT over head lines and fixing other side or depositing to MES store yard.
Dismantling, cross arms, clamps, supports made of channels or angle section etc including nuts and bolts and setting aside all as required at site or directed.
Dismantling stay assy complete including excavation for taking out PCC block breaking of PCC block for taking out MS plate and depositing iron item to MES store yard and removing of PCC from site.
Dismantling PCC/steel poles any type and any size including excavation for taking out pole, breaking of PCC block with due care and setting aside for reuse or depositing to MES stores yard.
Unbinding from insulators ACSR conductor any size of LT/HT over head line for repairs. Re-stretching of ACSR conductor to achieve proper sag and rebinding to the insulators using alumn/GI binding wire and making all existing cable connections all as required at site.
Supply, errecting and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) duly painted with two coat of black bituminous paint through out, internally and externally up to planning depth and painting remaining portion of pole with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking pole number with black paint all as spfd and directed. (Note : Excavation, earth work, PCC work shall be measured and paid separately under respective items)
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape ors size as indicated or directed and inclusive of oneprimer coat, one under coat and one finishing coat of alumn paint.
M&L for stay assy complete with MS stay plate of size 300x300x6mm thick, stay rod 16mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I of 1991 or directed by Engr-in-charge ( Excavation, PCC, and loop type insulators will be measured separately).
S&F for loop type insulator large size with overall dimensions 90x140mm with clearance of hole 25.5 mm vitreous white brown or green.
Fixing only insulator any type and any size from HT/LT over head lines.
S&F Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade
M&L in replacement of for GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
All as per srl item No 44.00 but 50mm bore
All as per srl item No 44.00 but 40mm bore
S&F in replacement of bus bar chambers 300 mm long iron clad with 4 Nos 400 Amp rated Aluminium strips complete fixed flush wall and making good the disturbed wall surfaces all as a required at site or directed.
All as per srl item No 47.00 but with 4 Nos 200 Amp.
All as per srl item No 47.00 but with 4 Nos 100 Amp.
Repair, maint and of broken doors for LT panel and bus bars by welding and incl fixing of new hinges and other material as required at site complete all as spfd and directed.
Removal of unwanted vegetation/bushes/small plants shrubs around the water/electric supply installations/ inside the valve pit and surface excavation not esceeding 15 cm depth leveling the ground and removing the excavated material to a distance exceeding 50 M.
M & L for cutting, trimming of branches along the OH conductor of LT/ HT line within 2 mtr distance along both side of line and strictly all branches in one place as directed by Engineer-in-Charge.
S&F in replacement of MCCB 4 Pole 415 Volts 3 phase 400 Amps 36 KA, thermal magnetic release S1 -01 No (incoming). Make : Legrand/Siemens 3WL (ETU45B) / Schneider NW (6.0A)/L&T/ABB
All as per item No 53.00 but MCCB 630 Amps 35/36 KA.
All as per item No 53.00 but MCCB 250 Amps 35/36 KA.
All as per item No 53.00 but MCCB 160 Amps 36 KA.
All as per item No 53.00 but MCCB 100 Amps 25 KA.
All as per item No 53.00 but MCCB 63 Amps 25 KA.
All as per item No 53.00 but MCCB 3 pole 100 Amps 25 KA.
All as per item No 53.00 but MCCB 3 pole 160 Amps 36 KA.
Detection of any type of fault in HT/LT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable. Note : 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required.
S&F Cable Lugs up to 50 Sqmm made up of Aluminium for HT/LT
S&F Cable lugs above 50 to 120 Sqmm made up of Aluminium for HT/LT
S&F Cable lugs above 120 to 240 Sqmm made up of Aluminium for HT/LT
S&F Cable lugs above 300 sqmm made up of Aluminium for HT/LT
M&L in replacement of earthing complete with galvanised cast iron earth plate electrode of size 600x600x6 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed incl testing on competion.
M & L for fixing earthing strip 32 x 6 mm aluminium strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, In Repair,complete all as specified & directed.
S B ENTERPRISES (BID ID -3239682)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .