GE NAGROTA
GE NAGROTA C/O 56 APO
REPAIR AND MAINTENACE OF MOTORS, VOLTAGE STABILIZER, PANELS STARTER AND CONNECTED ITEMS AT GE NAGROTA.
2020_MES_391951_1
GEN-48/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAGROTA
Class E and above and category b (I)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹32,000
Yes
22 Dec 2020
3 Nov 2020
8 Dec 2020
3 Nov 2020
3 Dec 2020
17 Nov 2020
60 days
Amount
Material and labour for rewinding of centrifugal motor of any description, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots and rewinding of the electric motor of 3 phase, 415 Volts, 50 Hz AC supply and rewinding with existing gauge copper wire including insulating material such as illumines paper, etherized paper, cotton waste, glass sleeves insulating varnish etc, refixing on existing platform and connected all the electric connections and mechanical connections and testing the complete pumping set up to the entire satisfaction of the Engr-in-Charge for 01 HP to 5 HP capacity complete all as specified and directed. (Note: - Foundation nut bolts, washers and mounting pads required for fixing the centrifugal pumping sets and Booster pumping sets shall be provided by the contractor and rate for the same shall be deemed included in the quoted rates)
All as per item No. 01 here-in-before but capacity 15 HP .
All as per item No.01 here-in-before but capacity 20 HP .
All as per item No. 01 here-in-before but capacity 30 HP.
All as per item No. 01 here-in-before but capacity 40 HP.
All as per item No. 01 here-in-before but capacity 50 HP.
All as per item No. 01 here-in-before but capacity 60 HP.
All as per item No. 01 here-in-before but capacity 75 HP.
All as per item No. 01 here-in-before but capacity 125 HP.
Remetaling, grinding, polishing and balancing of shaft for induction motor of capacity 5 to 15 HP. Note: (i) The rate for replacement of bushes, shaft sleeves etc required for making the shaft functional shall be included in the quoted rate).
All as per item No 10 here-in-before but of cap 20 to 30 HP
All as per item No 10 here-in-before but of cap 40 to 60 HP
All as per item No 10 here-in-before but of cap 75 to 125 Hp
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 5 to 15 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor of cap 20 to 30 HPas per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor of cap 40 to 60 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor of cap 75 to 125 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of star coupling suitable for connecting centrifugal motor and pump of capacity upto 75 HP complete all as specified and directed.
Supply and fixing in replacement of Tyre coupling suitable for connecting centrifugal motor and pump of capacity upto 75 HP complete all as specified and directed.
Supply and fixing in replacement of Tyre coupling suitable for connecting centrifugal motor and pump of capacity 125 HP complete all as specified and directed.
Supply and fixing in replacement of bowl assembly with studs & nuts for submersible pump set of capacity 12.5 HP to 30 HP.
Supply and fixing in replacement of thrust plate of submersible pump set of cap 12.5 HP to 30 HP.
Supply and fixing in replacement of thrust bearing of submersible pump set of cap 12.5 HP to 30 HP.
Material and labour for rewinding of submersible motor of any description, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots and rewinding of the electric motor of 3 phase, 415 Volts, 50 Hz AC supply and rewinding with existing gauge PVC copper wire including insulating material such as illumines paper, etherized paper, cotton waste, glass sleeves, thrust bearing and connected all the electric connections and mechanical connections and testing the complete pumping set up to the entire satisfaction of the Engr-in-Charge for 12.5 HP capacity. Note : (i) Cost of lifitng & lowering of submersible pump set of any capacity from dug well carrying the pump or motor to workshop for repair/rewiring and re-install the same on its original position and transportation of pump set to work shop and back, opening the pump set and taking out unserviceable parts are deemed to be included in the quoted rate. (ii) Cost of minor parts such as bush, neck ring and thrust pad etc is deemed to be included in the quoted rate.
All as per item No 24 here-in-before but of cap 25 to 30 HP complete all as specified and directed.
Material and labour for rewinding of vertical turbine motor of any description, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots and rewinding of the electric motor of 3 phase, 415 Volts, 50 Hz AC supply and rewinding with existing gauge copper wire including insulating material such as illumines paper, etherized paper, cotton waste, glass sleeves insulating varnish etc for powering multistage pumps, refixing on existing platform and connected all the electric connections and mechanical connections and testing the complete pumping set up to the entire satisfaction of the Engr-in-Charge for 30 HP capacity complete all as specified and directed. Note : (i) Cost of lifting & lowering of VT pump set of any capacity from dug well carrying the pump or motor to workshop for repair/rewiring and re-install the same on its original and transportation of pump set to workshop and back, opening the pump set and taking out unservicebale parts are deemed to be included in the quoted rate.
All as per item No 26 here-in-before but capcity 50 HP complete all as specified and directed.
Supply and fixing in replacement of thrust bearing of VT motor of capacity 30 HP to 50 HP complete all as specified and directed.
Supply and fixing in replacement of ratchet plate of VT motor of capacity 30 HP to 50 HP complete all as specified and directed.
Supply and fixing in replacement of ball bearing of VT motor of capacity 30 HP to 50 HP complete all as specified and directed.
Supply and fixing in replacement of stainless steel line shaft with sockets of capacity 30 HP to 50 HP VT pump set complete all as specified and directed.
Supply and fixing in replacement of guide spider of capacity 30 HP to 50 HP VT pump set complete all as specified and directed.
Opening and checking and repair of fully automatic voltage stablizer fault analyser cum control system with (a) Low voltage o\cut off 350 volt AC (b) High Voltage Cut off 450 Volt AC (c) Pick up volt AC (d) Cut off time-Fraction of time (e) Unbalanced volt cut off a deference of 35 volt to 45 volt between any two phase with 3 phase with 3 phase over load protection once in a month to make it fuction at all the times for smooth operation of pumping set installed at various location of water supply installations complete all as specified and directed. Note : (i) Spare parts such as contractors of various capacities will be measured and paid separately. (ii) Minor parts of the system will be replaced during checking and the cost of the same is deemed to be included in the quoted rate.
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 70 Amps.
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 110 Amps.
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 185 Amps.
Disconnecting and transport to workshop and complete connection after disconnecting of voltage stabilizer, opening for repair automatic voltage stabilizer for automatic operation air natural/oil cooled servo controlled type input voltage 260-440 V and output voltage 420 V capacity 25 to 30 KVA complete all as specified and directed. Note:(i) Cost of transportation of voltage satblizer to workshop and back after repair/rewinding complete is deemed to be included in the quored rate. (ii) Replacement of the parts if any found worn out/defective shall be measured and paid for separately.
All as per item No. 37 here-in-before but capacity 50 KVA to 75 KVA.
All as per item No. 37 here-in-before but capacity 160 KVA to 200 KVA.
All as per item No. 37 here-in-before but capacity 400 KVA.
Supply and fixing in replacement of dimmer coil with super enameled copper winding wire of existing wire of existing make and size complete in all respect including vernishing tapping and insulating material to get same capacity of 25 to 30 KVA complete all as specified and directed.
All as per item No. 41 here-in-before but capacity 50 KVA to 75 KVA.
All as per item No. 41 here-in-before but capacity 160 KVA to 200 KVA.
All as per item No. 41 here-in-before but capacity 400 KVA.
Dismantling of primary and secondary coils carefully taking out winding wire preparing for rewinding with super enameled copper winding wire of appropriate guage with allied insulating material varnish the winding with air drying insulating varnish heat treatment etc of 50 KVA 75 KVA complete all as specified and directed.
All as per item No. 45 here-in-before but capacity 80 KVA to 150 KVA.
All as per item No. 45 here-in-before but capacity 160 KVA to 200 KVA.
All as per item No. 45 here-in-before but capacity 400 KVA.
Supply and fixing in replacement of electronic circuit plate complete with DC transformers complete all as per existing size and shape (PCB cold) complete all as specified and directed.
Dismantling of old servo motor and supply and fix new servo motor of existing size and shape along with all connected accessories and cap complete all as specified and directed.
Dismantling of old carbon bush with carbon holder incl S & F new carbon bush with carbon holder of existing size and shape complete
Supply and fixing in replacement of brass studs fixed for input and output of stabilizer with brass nuts along with all necessary connection complete all as specified for any capacity of voltage stabilizer complete all as specified and directed.
Supply & filling in replacement of insulating oil ( Transformer oil) having break down value not less then 60 KV die electric strength when tested between 2.5 mm gap electrode complete all as specified and directed.
Taking down of manually operated oil immersed star delta starter of any capacity from its existing position, removing the transformer oil in a suitable container for reuse, replace the old unserviceable fixed and moving contract, over load coils, no volt coil complete and refixing the starter assembly in its existing position connecting the complete system and making the starter functional complete all as specified and directed.
Dismantling of reduction gear flocculators/pre sedimentation tank type V 400 ratio 1:60 with replacement of V velts, gear oilet repair to gear, gear shaft, repair to rail and wheel with greasing of the flocculator, alingnment, complete all as specified and directed.
Supply and fixing in replacement of submersible cable un armored PVC insulated & sheathed copper conductor cable 1100 Volts grade of size 16 Sqmm 3 core complete all as specified and directed.
Supply and fixing in replacement of MCCB 400 Amps 4 pole 415 Volts 36 KA with adjustable thermal and adjustable magnatic setting fixed in repair as per existing at site and all as specified and directed by Enginer-in-Charge.
Supply and fixing in replacement of MCCB 250 Amps 3 pole 415 Volts 36 KA with adjustable thermal and adjustable magnatic setting fixed in repair as per existing at site and all as specified and directed by Enginer-in-Charge.
Supply and fixing in replacement of MCCB 200 Amps 3 pole 415 Volts 36 KA with adjustable thermal and adjustable magnatic setting fixed in repair as per existing at site and all as specified and directed by Enginer-in-Charge.
Supply and fixing in replacement of MCCB 100 Amps 3 pole 415 Volts 16 KA fixed type as per existing at site and all as specified and directed by Enginer-in-Charge.
Supply and fixing in replacement of volt meter with CT as per existing size complete all as specified and directed.
Supply and fixing in replacement of Amp meter with CT as per existing size complete all as specified and directed.
Supply and fixing in replacement of indicator lamp assembly complete LED type suitable for the existing system supply voltage 230V/440V AC including taking down old lamp assembly complete all as specified and directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Rs. 155630.00 during AOC Note:- Tenderers shall not quote for this Schedule
ARORA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .