Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | M/s Siemens Ltd, Goa (SIEMENS) ₹10.1 Cr | - | |
| 2 | Qualified | Qualified | |
| 3 | Qualified | Qualified | |
| 4 | Qualified | Qualified |
Tender Value
Refer Docs
EMD Value
₹57.9 L
Closing Date
24 Sept 2020, 11:00 amClosed
RAM LAL
Power Grid Corporation of India Limited Saudamini, 3rd Floor, Plot No.-2, Sector-29 Gurgaon (Haryana) - 122001.
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region
CC-CS/987-ER1/MISC-4017/3/G5
Open
Electrical
Works
Bihar
₹25,000
₹57.9 L
31 Dec 2020
19 Jun 2020
28 Sept 2020
19 Jun 2020
24 Sept 2020
19 Jun 2020
7 Jul 2020
Name of Package : Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
Specification No. : CC-CS/987-ER1/MISC-4017/3/G5
Completion Period 21 Months
: Attachments : General guidelines for filling up the Attachments : Substation Package -Y :
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
Specification No.: CC-CS/987-ER1/MISC-4017/3/G5
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(JV), 3(QR), Attach QR, 4, 4(A), 4(B), 5, 5(A), 6, 7, 9, 10, 11, 12, 13, 14, 15, 16, 17,18, 19 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : To be submitted as perproforma provided in the bidding document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. Not included here.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(n) and as per remarks in the Attach 14-IP.
7 Attachment 18 Safety Pact : To be submitted as per ITB Clause No. 9.3(r) and as per remarks in the Attach 18.
8 Attachment 20, Attachment-21, Attachment-22, Attachment-23, Attachment-24, Attachment-25 & Attachment-26 : To be submitted as per the provisions of the Bidding Documents ( Formats Attached seperately in Volume-III of Bidding Documents)
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
Specification No.: CC-CS/987-ER1/MISC-4017/3/G5 Sole Bidder 1
Enter following details of the bidder No
Specify type of Bidder [Select from drop down menu] Sole Bidder Sole Bidder 2 0
Whether the bidder is an MSE (Micro & Small Enterprise) 0 2 2 0
Enter the Name of Registration Authority
Name of Sole Bidder
Address of Sole Bidder
Name of other Partner - 1
Address of other Partner - 1
Route-1 of Annexure-A(BDS)
Route-2 of Annexure-A(BDS)
Name of other Partner - 2 (more, if any) Joint venture Route
Address of other Partner - 2 (more, if any)
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-3(JV) Sole Bidder
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
This Attachment is Not Applicable
Name(s) and Addresse(s) of other partner(s)
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith Sole Bidder
Date : -- Printed Name : 0
Place : Designation : 21
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-3(QR)
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Qualifying Requirement Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
For our Qualifying Requirements Data, please refer Schedule-QR of this volume.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-4
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby certify that equipment and materials to be supplied are produced in [Name of Countries], eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Name of Countries], eligible source country. [Name of Countries] [Name of Countries] [Name of Countries], [Name of Countries],
Date : -- Printed Name :
Place : Designation :
country. country. [Name of Countries], [Name of Countries],
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-4(A)
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-4(B)
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-5
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of the items/ sub-assemblies, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Details of the proposed sub-contractor/sub-vendor Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-5A
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder's Name and Address: Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1 We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
2 The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-5A
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-6
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Annexure I toAttachment-6
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-7
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Details of Alternative Bid)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
No Alternative Bid
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Work Completion Schedule)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region. for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Period in months from the effective date of contract
1 Detailed Engineering and drawing submission
a) commencement
2 Procurement of equipment/ components & assembly
a) commencement
a) commencement
4 Manufacturing
a) commencement
5 Shipments & Delivery
a) commencement
6 Establishment of site office
7 Installation at Site
a) commencement
8 Testing & Pre-commissioning
a) commencement
9 Trial Operation
a) commencement
Date : -- Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-10
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Guarantee Declaration)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Dear Sir, We confirm that the equipments offered shall have minimum performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-11
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly, we hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation*
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : -- Printed Name :
Place : Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 ATTACHMENT-12
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
FIXED PRICE BASIS
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the Substation Package SS-43. The necessary documentary evidence is enclosed.
Sl. No. Name of Materials/Labour Value of co-efficient Name of the published index Value of index as 30 days prior to date set for opening of bids
In accordance with Clause 2, Appendix-2, Form of Contract Agreement, Section-VI; Forms. Volume-I
A. For Equipment Ex-Works Price Component
I. Circuit Breaker
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
II Current Transformer
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
III Capacitive VoltageTransformer
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
V Surge Arrester
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
VI PVC/XLPE Insulated Power and Control Cable
a) a=PVC Compound 0.15
b) Published Price of Metal IEEMA
i) Aluminium per MT IEEMA
ii) Copper per MT IEEMA
c) Weight in MT of Metal per kM (Size wise)
VII Substation Structures
i) Lattice Steel Structures & Pipe Structures (including bolts & nuts, washers & foundation bolts)
a) Raw Materials
i) a=Structural steel 0.58 JPC Market Price (Retail) for average Price of Steel Angles of size 50 x 50 x 6 mm of all cities in Rs./MT as published by Joint Plant Committee(JPC).
ii) b=Electrolytic Zinc 0.16 IEEMA
b) Labour 0.11 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
VIII. LT Transformer
a) with Insulating oil:
i) Copper a= Price indices for Average LME settlement price of copper wire bars, as published by IEEMA
ii) Electrical Lamination Steel b= Price indices for CRGO Electrical Steel Lamination, as published by IEEMA
iii) Construction Steel c= Price indices for Steel Plates [HR Coil 3.15mm thick (for ratings upto 2,500KVA and voltage upto 33kV)/ MS plate 6mm thick (for rating above 2,500KVA upto 10MVA and voltage upto 33kV)], as published by IEEMA
iv) Insulating Material d= Price indices for Insulating materials, as published by IEEMA
v) Transformer Oil e= Transformer Oil (TO): Transformer oil conforming to IS:335-1993, supplied in drum(Ex-Refinery, Mumbai) as published by IEEMA.
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of all the coefficients including labour shall be a+b+c+d+l=0.85
B. For Installation Price Component
I Installation price component (including Civil works but excluding ‘supply & placement of reinforcement steel’ and ‘concreting’)
i) Labour I= 0.80 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
II Supply & Placement of Reinforcement Steel
i) HSD 0.10 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour I= 0.05 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
iii) Manufacture of Basic Metals 0.65 Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
III For Concereting
i) HSD 0.20 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour I= 0.10 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
iii) Manufacture of cement, lime and plaster 0.30 Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in)
iv) Cutting, shaping and finishing of stone 0.20 Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-13
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-14
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Integrity Pact is annexed herewith this Volume.
Date : -- Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (o).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai,New Delhi – 110016 hereinafter referred to as
having its Registered Office at
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Integrity Pact Page 1 of 8
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region. Package and Specification Number CC-CS/987-ER1/MISC-4017/3/G5 POWERGRID values full compliance with all relevant laws of the land, rules, regulations, economic use of resources, and of fairness / transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as unde r:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity, fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personal interest in the Companies/Agencies participating in the Bidding/Tendering process and all known prejudiced persons.
(2) If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC / PC Act , or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID’s Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles during its participation in the tender process and during the contract execution:
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or during the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC / IPC Act.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/information in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
g) The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may, after following due procedures, ban /blacklist the Bidder/Contractor in line with POWERGRID’s policy for “Black-Listing of Firms / Banning of Business”. The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for forfeiture of the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country, that may impinge on the Anti-corruption principle.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID’s policies.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or its subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of the IEMs have been indicated in the Bidding Documents.
(2) The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings, at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He / She reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his / her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEMs information as sought by him / her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on ’Non-Disclosure of Confidential Information’ and of ‘Absence of Conflict of Interest’. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and recuse himself/herself from that case
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he / she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC / IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Integrity Pact Page 6 of 8
(9) While representing any matter in relation to the Integrity pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter.
(10) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing. Side agreements have not been made.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
(6) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Integrity Pact Page 7 of 8
(7) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Integrity Pact Page 8 of 8
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-15
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Initial Advance
Supply Portion:
Services Portion:
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3 (a). Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3 (b). Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment /notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached. Please refer remarks at the end of the Attachment. No
3 (c). If 3(b) is 'Yes', please mentiom whether you are (Proprietary MSE/ Partnership MSE/Private Limited Company) owned by SC/ST Entrepreneurs.
3 (d). Are you a MSE owned by a women in line with Public Procurment Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurment Policy for Micro & Small Enterprises (MSEs) Amendment Order 2018 including subsequent amendment / notification/order . (Indicate Yes/No) No
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
6. PF Registration No. of the Company
7. PF Regional Office covered (with Address)
8. Name of Contact Person
9. Contact Details
10. Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
11. 9 digit MICR code printed at bottom in middle, next to cheque no.
12. IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC /ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-16
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Additional Information)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder)
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
5.0 Details of Provident Fund Code Number of the Bidder [ref. ITB9.3(q)]
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-17
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-17
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. "Saudamini", Plot No. 2, Sector 29
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-17
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-18
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Safety Pact is attached herewith this Volume
Date : -- Printed Name :
Place : Designation :
Instruction for printing & submitting Safety Pact
1. The requisite format of Safety Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other six pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Safety Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (s).
Between #REF! #REF!
Power Grid Corporation of India Limited #REF! #REF!
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as #REF! #REF!
"POWERGRID", #REF! #REF!
0 1 having its Registered Office at ,
having its Registered Office at ,, 1 AND
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region. Specification Number:CC-CS/987-ER1/MISC-4017/3/G5
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Safety Pact Page 1 of 6
POWERGRID values full compliance with all relevant laws and regulations and the principles of Safety, Health& Environment in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder / Contractor enter into this agreement called “Safety Pact” which will form part of the Bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
POWERGRID commits itself to take all measures necessary to prevent accidents duringConstruction and Operation of the Transmission Assets and to observe the following:
1. POWERGRID recognizes and accepts its statutory responsibilities for ensuring construction, operation and maintenance of equipments and for the provision of safe methods of work and safe working conditions.
2. POWERGRID recognizes and accepts its statutory responsibilities for ensuring safety of not only its employees but also that of the Contracting Agencies as Principal Employer.
3. POWERGRID shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction as well as Operation & Maintenance of the Transmission Assets.
4. POWERGRID shall conduct necessary awareness and training programmes to its Employees to augment the various safety requirements to be followed during Construction and Operation & Maintenance of the Transmission Assets from time to time.
5. POWERGRID shall, from time to time, issue necessary guidelines,instructions and deterrents to its employees as well as to the Contracting Agencies, to update them to take necessary preventive measures to avoid repetition of similar accident attributes.
6. POWERGRID shall review and provide necessary guidanceto the Contracting Agencies, as and when, any abnormality / special situations are brought to its notice by the Contracting Agencies during execution of the Transmission Projects being executed by them.
7. POWERGRID shall conduct periodical surveillance site inspections / audits to identify the unsafe conditions and unsafe actions, and bring them to the knowledge of the Contracting Agencies for taking timely corrective actions.
8. POWERGRIDshall investigate all accidents, fatal as well as non-fatal, to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents, and fix responsibility for the lapses leading to the accident.
9. POWERGRID shall augment the training to the workers and supervising personnel of the Contracting Agencies, as per schedules, upon nomination by the Contracting Agencies in reasonable time frame.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Safety Pact Page 2 of 6
10. POWERGRID shall exercise the right to claim and recover compensation from the Contracting Agencies in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the applicable Laws and contractual specifications / guidelines in vogue / issued by POWERGRID from time to time.
Section II – Commitments of the Bidder / Contractor:
The Bidder / Contractor commits himself to take all measures necessary to prevent / minimise accidents at their construction / erection sites and to observe the following:
1. The Bidder / Contractor recognizes and acceptsthe statutory and comprehensive responsibility for ensuring safe construction and Testing & Commissioning in the Transmission Projects being executed by them by providing safe methods of work, working conditions and Tools & Plants for human safety.
2. The Bidder / Contractor recognizes and accepts the responsibilities for ensuring safety of not only their employees but also that of the Sub-contractors, Principal Employer and the general public during execution of the Transmission Projects / works.
3. The Bidder / Contractor shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction of the Transmission Assets.
4. The Bidder / Contractor shall endeavour continuous development of safe methods of work to ensure that the effect of risks and perils are minimised to the extent possible and implement the same at their worksites.
5. The Bidder / Contractor shall conduct periodical Training to their Employees as well as to that of their Sub-contractors for safety awareness during construction works being executed by them.
6. The Bidder / Contractor shall provide all requisite Tools & Plants required for the work and ensure their healthiness by periodical inspections / testing as required. Unhealthy and sub-standard Tools & Plants will be immediately removed from site as and when they are identified.
7. The Bidder / Contractor shall,at their cost, provide all necessary Personal Protective Equipments such as Double Lanyard Safety Belts, Appropriate Fall Arrest Systems, Safety Helmets, Foot Wear, Hand Gloves, etc., as required for various activities pertaining to execution of the Projects / works, confirming to relevant Indian Standards.
8. The Bidder / Contractor shall ensure that dedicated qualified Safety Officers are posted in the construction projects being executed by them and ensure that the Safety Officer visits each and every gang periodically and conducts audits / inspections to identify the unsafe conditions and unsafe actions, to be rectified by the site supervising personnel promptly.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Safety Pact Page 3 of 6
9. The Bidder / Contractor shall conduct appropriate medical checks-up for the workers before deploying them at their construction sites to ensure that only those who are medically fit are deployed in the Projects / works to be executed by them. The copy of the Medical Reports shall be provided by the Bidder / Contractor to POWERGRID, whenever requested by POWERGRID.
10. The Bidder / Contractor shall screen the workers before deploying them at their construction sites to ensure that only those with the skills, experience and competence to work at height and also medically fit for work at height are deployed for work at height in the Projects executed by them.
11. The Bidder / Contractor shall ensure daily before starting the work that their site Supervising Personnel / Safety Officer briefs the workers about the work for the day and the safety measures / precautions required to be taken by them.
12. The Bidder / Contractor shall investigate all the accidents at their working sites to ascertain the lapses leading to the incident and the precautionary / corrective measures required to be taken to avoid recurrence of such accidents. These accidents will be reviewed at the Board Management level of the Agencies and the findings / recommendations will be put up to POWERGRID Apex Safety Board within the stipulated period.
13. The Bidder / Contractor shall ensure that all accidents, whether fatal or non-fatal in nature, will be informed to POWERGRID, in writing, immediately on the occurrence of the same,and in any case, within not more than 24 hours of occurrence of the same.
14. The Bidder / Contractor shall ensure that in case of any accident, all necessary medical help / support shall be provided to the victims / injured till they are completely fit to return to work.
15. The Bidder / Contractor shall ensure that in case of fatal accidents, all statutory Authorities, including Police, concerned Labour Dept. Officials, concerned Workmen Compensation Commissioner, etc., will be intimated in writing as required by the statutory Law, and followed up for compliance of all statutory obligations. The Bidder / Contractor shall own full responsibility of timely accident reporting to various authorities, including POWERGRID.
16. The Bidder / Contractor shall ensure that in case of fatality or serious injury leading to permanent disablement of the victims, the compensation amount will be deposited with the concerned authorities, as required by the Laws, and followed up for early disbursement to the beneficiaries of the victims.
17. The Bidder / Contractor assures that they shall co-operate to the fullest extent for carrying out any investigation of the accidents at their work sites by POWERGRID to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents. All factual details of the occurrence of the accident will be provided to POWERGRID, as and when required.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Safety Pact Page 4 of 6
18. The Bidder / Contractor assures that they take full responsibility of meeting the statutory obligations in case of accidents, and in case of any reference by any Statutory Body at a later date also, they shall provide all information to POWERGRID and meet all the statutory obligations, including payment of additional compensation, if any.
19. The Bidder / Contractor assures that in case of any inspection of their work site or Notice by any Statutory Authority, they shall comply promptly and inform POWERGRID Site Officials of the same, and also provide all necessary information and assistance for smooth compliance of the observations / instructions of such Authorities.
20. The Bidder / Contractor accepts the provisions regarding safety, including payment of any sums to POWERGRID, in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the Contractual Conditions, Safety Planand the Safety Pact, and confirm to abide by the same.
Section III – Equal treatment to all Bidders / Contractors:
1. POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
2. POWERGRID will disqualify, from the tender process, any bidder/ take punitive actions on the bidder, who does not sign this Pact or violate its provisions.
Section IV – Pact Duration:
This Pact begins when both parties have legally signed it. It expires for the successful Bidder / Contractor after closure of the contract and, for all other Bidders, after the contract has been awarded.
Section V – Other Provisions:
1. This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under the Safety Pact.
2. Changes and supplements need to be made in writing, which shall come into force only upon mutual agreement / acceptance.
3. If the Contractor is a partnership firm or consortium of Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venue partners, as applicable as per the Tender Specifications.
4. Nothing in this agreement shall affect the rights of the parties available under General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
5. Should one or several provisions of this agreement turn out to be invalid, the reminder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
Safety Pact Page 5 of 6
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Safety Pact Page 6 of 6
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Attachment-19
Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/987-ER1/MISC-4017/3/G5 Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : -- 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contract Services 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
"Saudamini", Plot No. 2, Sector 29 11 eleven 11 th 11 November
Gurgaon (Haryana) - 122001 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Package-Y for RTU replacement/SAS Upgradation Package for Eastern Region under Upgradation of SCADA/RTUs/SAS in Central Sector Stations and strengthening of OPGW network in Eastern Region. 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
Or Online Payment Acknowledgement towards Bid Security for a sum of INR
Or documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 13.1 of ITB, Section-II
(b) Attachment 2: A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Please note that if bid validity is less than 07 (seven) months, your bid may be rejected Bank Guarantee (0) 21 st
(c) Attachment 3 : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). #REF! Applicable 23 th
Further the required deed of Joint Undertaking signed by us and Tower Manufacturer has also been furnished as per your format. 0 #REF! Not Applicable 24 th
(d) Attachment 4 : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5 : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A : Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises
(g) Attachment 6 : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7 : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 28 th
(i) Attachment 8 : Manufacturer’s Authorisation Forms. 29 th
(j) Attachment 9 : Work Completion Schedule. 30 th
(k) Attachment 10 : Guarantee Declaration. 31 st
(l) Attachment 11 : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12 : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13 : Declaration regarding Social Accountability.
(o) Attachment 14 : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15 : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16 : Additional Information.
(r) Attachment 17 : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18 : Safety Pact
(t) Attachment 19 : Declaration.
(u) Attachment 20 : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 21: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order and MoP Order December 2018, if applicable
(w) Attachment 22: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order and MoP Order December 2018, if applicable
(x) Attachment 23: Authorization certificate issued by Domestic Manufacturer for selling Domestically Manufactured Iron & Steel Products
(y) Attachment 24: Affidavit of Self certification regarding Domestic Value Addition in Iron & Steel Products
(z) Attachment 25: Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
(aa) Attachment 26: Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, In-transit insurance, unloading, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 8 Terms of Payment
(d) GCC 9.3 Performance Security
(e) GCC 10 Taxes and Duties
(f) GCC 21.2 Completion Time Guarantee
(g) GCC 22 Defect Liability
(h) GCC 23 Functional Guarantee
(i) GCC 25 Patent Indemnity
(j) GCC 26 Limitation of Liability
(k) GCC 38 Settlement of Disputes
(l) GCC 39 Arbitration
(m) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 2
13.0 We are a Micro and Small Enterprise (MSE) registered with , a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012. 2
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
#REF! Printed Name :
#REF! Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Name of Sub station Angul
Sl No Description Remarks
1 SAS make SIEMENS
2 SAS Operating system Windows version WINDOWS 7 PROFESSIONAL
List of IEDs(Baywise) along with their version no.
Sl No Bay name Bay NO IED Description(distance/diff/etc) MLFB No Firmware version
5 Tie Bay(ICT-1/Ang-Bolangir) 402RT BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
7 400kV Angul-Bolangir 403RA 21.1 (7SA52) 7SA5221-6CB90-4QB4/GG V04.70.07
9 403RB BCU(6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
12 125 Mvar Bus Reactor#3 404RA 87R 7UT6131-6EB92-1AA0/FF V04.65.02
14 404RB BCU (6MD66) 6MD6631-5EB90-0AA0/GG Los V04.82.05
18 Tie Bay 405RT BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
20 400 kV Meramadali#1 406RA 21.1 (7SA52) 7SA5221-6CB90-4QB4/GG V04.70.07
22 406RB BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
29 Tie Bay 408RT BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
31 400kV Angul-Talcher 409RA 21.1 (7SA52) 7SA5221-6CB90-4QB4/GG V04.70.07
33 409RB BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
36 125 Mvar Bus Reactor#2 410RA 87.1R (7UT61) 7UT6131-6EB92-1AA0/FF V04.65.02
38 410RB BCU (6MD66) 6MD6631-5EB90-0AA0/GG V04.82.05
42 Tie Bay 411RT BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
44 400 kV Meramadali#2 412RA 21.1 (7SA52) 7SA5221-6CB90-4QB4/GG V04.70.07
46 412RB BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
50 BCU 2 (6MD63) 6MD6331-5EB90-AA0/EE
54 Tie Bay of ICT-3 414RT BCU(6MD66) 6MD6331-5EB90-0AA0/GG
58 125 Mvar Bus Reactor#1 416RA 87.1R (7UT61) 7UT6131-6EB92-1AA0/FF V04.65.02
60 416RB BCU (6MD66) 6MD6631-5EB90-0AA0/GG V04.82.05
64 Tie Bay 0f BR#1 417RT BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
72 Tie Bay of ICT-4 420RT BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
80 400 kV Angul-Jindal#2 425RA 21.1 (7SA52) 7SA5221-6CB90-4QB4/GG V04.71.03
82 425RB BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.83.03
85 Tie Bay 426RT BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
89 400 kV Angul-GMR#1 427RA 21.1(7SA52) 7SA5221-6CB90-4QB4/GG V4.71.03
90 BCU(6MD66) 7SJ8041-5EB90-1FC0/CC V04.82.05
91 21.2(REL) REL670
93 400 kV Angul-Jindal#1 428RA 21.1 (7SA52) 7SA5221-6CB90-4QB4/GG V04.71.03
95 428RB BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
98 Tie Bay 429RT BCU (6MD66) 6MD6631-5EB90-0AA1/GG V04.82.05
103 BCU (6MD66) 6MD6631-5EB90-0AA1/GG
104 21.2(REL) REL670
114 704RC BCU-1(6MD66) 6MD6631-5EB92-0AA0-OS-LOS V4.82.05
115 BCU-2(6MD66) 6MD6631-5EB92-0AA0-OS-LOS V4.82.05
116 700R MCU-1(7SS522) 7SS5220-5AB92-1BA0/HH -LOS V4.72.08
117 MCU-2(7SS52) 7SS5220-5AB92-1BA0/HH -LOS V4.72.08
118 BCU-2(7SJ80) 7SJ8042-5EB90-1FC0-OS-LOS V4.63.05
119 BCU-1(7SJ80) 7SJ8041-5EB90-1FC0-OS-LOS V4.63.05
120 Tie Bay 705T BCU-1(6MD66) 6MD6631-5EB90-0AA1-OS-LOS V4.82.05
122 765 kv Angul-Sundargarh#2 706RA 21.1(7SA522) 7SA5221-6CB90-4QB4-OS V4.72.01
124 706RB BCU(6MD66) 6MD6631-5EB90-0AA1-OS-LOS V4.82.05
125 21.2(REL670 ABB) REL670
130 706RRB BCU-1(6MD66) 6MD6631-5EB92-0AA0-OS-LOS V4.82.05
131 BCU-2(6MD66) 6MD6631-5EB92-0AA0-OS-LOS V4.82.05
141 707RC BCU-1(6MD66) 6MD6631-5EB92-0AA0-OS-LOS V4.82.05
142 BCU-2(6MD66) 6MD6631-5EB92-0AA0-OS-LOS V4.82.05
143 Tie Bay 708RT BCU-1(6MD66) 6MD6631-5EB90-0AA1-OS -LOS V4.82.05
145 765 kv Angul-Sundargarh#1 709RA 21.1(7SA522) 7SA5221-6CB90-4QB4-OS V4.72.01
147 709RB BCU(6MD66) 6MD6631-5EB90-0AA1-OS-LOS V4.82.05
148 21.2(REL670 ABB) REL670
153 709RRB BCU-1(6MD66) 6MD6631-5EB92-0AA0-OS-LOS V4.82.05
154 BCU-2(6MD66) 6MD6631-5EB92-0AA0-OS-LOS V4.82.05
164 710RC BCU-1(6MD66) 6MD6631-5EB92-0AA0-OS -LOS V4.82.05
165 BCU-2(6MD66) 6MD6631-5EB92-0AA0-OS -LOS V4.82.05
166 Tie Bay 711RT BCU(6MD66) 6MD6631-5EB90-0AA0-OS -LOS V4.82.05
168 3×110 Mvar Bus Reactor#1 712RA 87R.1(7UT6) 7UT6131-6EB92-1AA0-OS 4.65.02
177 712RC BCU-1(6MD66) 6MD6631-5EB90-0AA0-OS -LOS V4.82.05
178 BCU-2(6MD66) 6MD6631-5EB92-0AA0-OS -LOS V4.66.04
187 713RC BCU-1(6MD66) 6MD6631-5EB92-0AA0-OS -LOS V4.82.05
188 BCU-2(6MD66) 6MD6631-5EB92-0AA0-OS -LOS V4.82.05
189 Tie Bay 714RT BCU(6MD66) 6MD6631-5EB90-0AA0-OS- LOS V4.82.05
191 3×110 Mvar Bus Reactor#2 715RA 87R.1(7UT6) 7UT6131-6EB92-1AA0-FF 4.65.02
200 715RC BCU-1(6MD66) 6MD6631-5EB90-0AA0-GG -LOS V4.82.05
201 BCU-2(6MD66) 6MD6631-5EB92-0AA0-EE -LOS V4.66.04
202 Tie bay (Ang-Sng#3) 719RT BCU-1(6MD66) 6MD6631-5EB90-0AA1 4.84.02
206 765 kv Angul-Sundargarh#3 720 RRA 87R.1(7UT6) 7UT61316EB921AA0 4.67.00
214 720RB 21.2(Alstom) MiCOM NA
215 BCU(6MD86) NA 7.33
216 87.2(7SS52) 7SS5251-5FA01-0AA1/GG NA
217 Tie bay (Ang-Sng#4) 722RT BCU-1(6MD66) 6MD6631-5EB90-0AA1 4.83.03
221 765 kv Angul-Sundargarh#4 723RRA 87R.1(7UT6) 7UT61316EB921AA0 4.65.02
229 723RB 21.2(Alstom) MiCOM NA
230 BCU(6MD86) NA 7.33
232 Tie bay (Ang-Sklm#2) 725RT BCU-1(6MD66) 6MD6631-5EB90-0AA1 4.83.03
236 765 kv Angul-Srikakulam#2 726RRA 87R.1(7UT6) 7UT61316EB921AA0 4.65.02
244 726RB 21.2(REL670 ABB) REL670 NA
247 Tie bay (Ang-Sklm#1) 728RT BCU-1(6MD66) 6MD6631-5EB90-0AA1 4.83.03
251 765 kv Angul-Srikakulam#1 729RRA 87R.1(7UT6) 7UT61316EB921AA0 4.65.02
259 729RB 21.2(REL670 ABB) REL670 NA
Data required for SAS upgradation in ER
Sl.No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
1 ER-1 BANKA ALSTOM SCE 5.12.1.0.exe 401 BNK-BSF CKT-I MAIN BAY ALSTOM C264 5.0.4.1-build08
2 401R BNK-BSF CKT-I LR-I BAY ALSTOM C264 5.0.4.1-build08
3 402 BNK-BSF CKT-I & ICT-I TIE BAY ALSTOM C264 5.0.4.1-build08
4 403 ICT-I MAIN BAY ALSTOM C264 5.0.4.1-build08
5 404 BNK-BSF CKT-II MAIN BAY ALSTOM C264 5.0.4.1-build08
6 404R BNK-BSF CKT-I LR-II BAY ALSTOM C264 5.0.4.1-build08
7 405 BNK-BSF CKT-II & ICT-II TIE BAY ALSTOM C264 5.0.4.1-build08
8 406 ICT-II MAIN BAY ALSTOM C264 5.0.4.1-build08
9 407 BNK-KHG CKT-I MAIN BAY ALSTOM C264 5.0.4.1-build08
10 408 BNK-KHG CKT-I & BR-I TIE BAY ALSTOM C264 5.0.4.1-build08
11 409 BR-I MAIN BAY ALSTOM C264 5.0.4.1-build08
12 410 BNK-KHG CKT-II MAIN BAY ALSTOM C264 5.0.4.1-build08
13 411 BNK-KHG CKT-II & BR-II TIE BAY ALSTOM C264 5.0.4.1-build08
14 412 BR-II MAIN BAY ALSTOM C264 5.0.4.1-build08
15 102 132 KV ICT-II ALSTOM C264 5.0.4.1-build08
16 103 132 KV BANKA-BANKA CKT-I ALSTOM C264 5.0.4.1-build08
17 104 132 KV ICT-I ALSTOM C264 5.0.4.1-build08
18 105 132 KV BANKA-BANKA CKT-II ALSTOM C264 5.0.4.1-build08
19 106 132 KV BANKA-SABOUR-I ALSTOM C264 5.0.4.1-build08
20 107 132 KV BANKA-SABOUR-II ALSTOM C264 5.0.4.1-build08
21 108 132 KVBUS COUPLER ALSTOM C264 5.0.4.1-build08
22 109 132 KV BANKA-SULTANGANJ-I ALSTOM C264 5.0.4.1-build08
23 110 132 KV BANKA-SULTANGANJ-II ALSTOM C264 5.0.4.1-build08
* Implemented SAS architecture to be attached
Data required for SAS upgradation in ER
Sl.No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
1 ERTS-2 BERHAMPURE M/s GE DS AGILE, SCE 5_12_1_0 Year of commissioning 2013 401 Berhampore-Bheramara-II Main BAY ALSTOM C264MB1M6910013303000031111N10 C264 5.0.4.1 P444, REL670
2 402 Bus Reactor 1 & Berhampore-Bheramara-II Tie Bay ALSTOM C264MB1M6910013303000031111N10 C264 5.0.4.1 P743
3 403 Bus Reactor 1 MAIN Bay ALSTOM C264MB1M6910013303000031111N10 C264 5.0.4.1 P633, P442, P141
4 404 Berhampore-Bheramara-I Main BAY ALSTOM C264MB1M6910013303000031111N10 C264 5.0.4.1 P444, REL670
5 405 Bus Reactor 2 & Berhampore-Bheramara-I Tie Bay ALSTOM C264MB1M6910013303000031111N10 C264 5.0.4.1 P743
6 406 Bus Rector 2 Main BAY ALSTOM C264MB1M691001340300A000111N10 C264 5.0.4.1 P643, P442, P141
7 407 Berhampore Sagardighi-I line MAIN BAY ALSTOM C264MB1M691001340300A000111N10 C264 5.0.4.1 P444, P546
8 408 Berhampore Sagardighi-I & Berhampore-Farakka-1 TIE BAY ALSTOM C264MB1M691001340300A000111N10 C264 5.0.4.1 P743
9 409 Berhampore-Farakka-1 MAIN BAY ALSTOM C264MB1M691001340300A000111N10 C264 5.0.4.1 P444, REL670
10 410 Berhampore Sagardighi-II line MAIN BAY ALSTOM C264MB1M691001340300A000111N10 C264 5.0.4.1 P444, P546
11 411 Berhampore Sagardighi-II & Berhampore-Farakka-II TIE BAY ALSTOM C264MB1M691001340300A000111N10 C264 5.0.4.1 P743
12 412 Berhampore-Farakka-II LINE MAIN BAY ALSTOM C264MB1M691001340300A000111N10 C264 5.0.4.1 P444, REL670
13 413 Berhampore-Bheramara-III LINE MAIN BAY ALSTOM C264MB1M6910013054000030111N10 C264 5.0.4.1 P444, D60
14 414 Berhampore-Bheramara-III TIE BAY ALSTOM C264MB1M6910013054000030111N10 C264 5.0.4.1 P743
15 415 Future Bay ALSTOM C264MB1M6910013054000030111N10 C264 5.0.4.1
16 416 Berhampore-Bheramara-IV LINE MAIN BAY ALSTOM C264MB1M6910013054000030111N10 C264 5.0.4.1 P444, D60
17 417 Berhampore-Bheramara-IV TIE BAY ALSTOM C264MB1M6910013054000030111N10 C264 5.0.4.1 P743
18 418 Future Bay ALSTOM C264MB1M6910013054000030111N10 C264 5.0.4.1
19 - AUX-BCU ALSTOM C264CB1M691000370100E031111N10 C264 5.0.4.1
Name of Sub station BOLANGIR
Sl No Description Remarks
1 SAS make SIEMENS
2 SAS Operating system Windows version WINDOW XP Professional
3 SAS Server software version WinCCExplorer: V7.0+SP2+Upd2 PAS server :V7.0 SP3 (07.00.62.995)
List of IEDs(Baywise) along with their version no.
Sl No Bay name Bay NO IED Description(distance/diff/etc) MLFB No Firmware version
1 Angul line 401 Distance protection M-I 7SA52216CB904QB4 V04.70.07
2 Distance protection M-II REL670 ver 1.1 rev 01 Station latest SLD
3 BCU 6MD66315EB900AA1 V04.81.03 SA architecture (latest)
4 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
5 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
6 Angul line Reactor 401R Back up impedance 7SA52216AB900EAO V04.70.07
7 REF 7SJ80425EB901FCO V04.62.05
8 DIFF Protection 7UT61316EB921AAO V04.64.03
9 BCU 6MD66315EB900AA0 V04.81.03
10 Breaker failure 7SS5251-5FA01-1AA1-Z/EE V3.3x
11 Jeypore line 403 Distance protection M-I 7SA52216CB904QB4 V04.70.07 SAS Server software version
12 Distance protection M-II REL670 ver 1.1 rev 01 SAS Operating system Windows version:
13 BCU 6MD66315EB900AA0 V04.81.03
14 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
15 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
16 Jeypore line Rector 403R Back up impedance 7SA52216AB900EAO V04.70.07
17 REF 7SJ80425EB901FCO V04.62.05
18 DIFF Protection 7UT61316EB921AAO V04.64.03
19 BCU 6MD66315EB900AA0 V04.81.03
20 BReaker failure 7SS5251-5FA01-1AA1-Z/EE V3.3x
21 Tie Bay 40102 BCU 6MD66315EB900AA0 V04.81.03
22 Breaker failure 7SS5251-5FA01-1AA1/FF V3.3x
23 Tie Bay 40304 BCU 6MD66315EB900AA0 V04.81.03
24 Breaker failure 7SS5251-5FA01-1AA1/FF V3.3x
25 ICT-II 402 DIFF Protection 7UT61316EB921AB0 V04.64.03
26 REF 7UT61316EB921BB0 V04.62.05
27 Back up (O/C,E/F) LV 7SJ80425EB901FCO V04.62.04
28 Back up (O/C,E/F) HV 7SJ80425EB901FCO V04.62.05
29 BCU 6MD66315EB900AA0 V04.81.03
30 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
31 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
32 ICT-II 404 DIFF Protection 7UT61316EB921AB0 V04.64.03
33 REF 7UT61316EB921BB0 V04.62.05
34 Back up (O/C,E/F) LV 7SJ80425EB901FCO V04.62.04
35 Back up (O/C,E/F) HV 7SJ80425EB901FCO V04.62.04
36 BCU 6MD66315EB900AA0 V04.81.03
37 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
38 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
39 Bus Reactor 408 Back up impedance 7SA52216AB900EAO V04.70.07
40 REF 7SJ80425EB901FCO V04.62.05
41 DIFF Protection 7UT61316EB921AAO V04.64.03
42 BCU 6MD66315EB900AA1 V04.81.03
43 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
44 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
45 Bus Reactor Tie Bay 40708 BCU 6MD66315EB900AA0 V04.81.03
46 Breaker failure 7SS5251-5FA01-1AA1/FF V3.3x
48 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
49 Breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
50 BUS BAR PROTECTION 400 MCU-I 7SS52205AB921AA0 V04.72.01
51 MCU-II 7SS52205AB921AA0 V04.72.01
52 Bus-1 Voltage 7SJ80415EB901FCO V04.62.04
53 Bus-2 voltage 7SJ80415EB901FCO V04.62.05
54 LTRP Battery Room BCU (6 Nos) 6MD66315EB900AA0 V04.65.02
55 220KV Kantapalli Line 203 Distance Protection M-I 7SA52216CB904QB4 V04.70.07
56 Distance Protection M-II REL670 ver 1.1 rev 01
57 BCU 6MD66315EB900AA1 V04.81.03
58 breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
59 220KV Sadaipalli Line 205 Distance Protection M-I 7SA52216CB904QB4 V04.70.07
60 Distance Protection M-II REL670 ver 1.1 rev 01
61 BCU 6MD66315EB900AA1 V04.81.03
62 breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
63 Future 207 Distance Protection M-I 7SA52216CB904QB4 V04.70.07
64 Distance Protection M-II REL670 ver 1.1 rev 01
65 BCU 6MD66315EB900AA1 V04.81.03
66 breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
67 Future 209 Distance Protection M-I 7SA52216CB904QB4 V04.70.07
68 Distance Protection M-II REL670 ver 1.1 rev 01
69 BCU 6MD66315EB900AA1 V04.81.03
70 breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
71 ICT-1 LV 208 BCU 6MD66315EB900AA0 V04.81.03
72 breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
73 ICT-II LV 212 BCU 6MD66315EB900AA0 V04.81.03
74 breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
75 TBC 210 BCU 6MD66315EB900AA1 V04.81.03
76 breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
78 breaker failure 7SS5251-5FA01-0AA1/FF V3.3x
79 BB 200 MCU 7SS52205AB921AA0 V04.70.09
80 Bus-1&2 Voltage 7SJ80415EB901FCO V04.70.09
81 LTRP 301 O/C 7SJ80425EB901FCO V04.62.04
82 BCU 7SS52205AB921AA0 V04.66.02
Data required for SAS upgradation in ER
Sl.No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
1 ER1 CHAIBASA SIEMENS DIGSI V4.90 401 MAIN BAY OF JAMSHEDPUR-1 LINE SIEMENS 6MD66 V04.83.03 21.1(SIEMENS SIPROTEC 7SA522),21.2 (MICOM P444)
SIEMENS DIGSI V4.90 402 TIE BAY OF JAMSHEDPUR LINE-1 AND ICT-1 SIEMENS 6MD66 V04.83.03 LBB 50Z (SIEMENS SIPROTEC 7VK61)
SIEMENS DIGSI V4.90 403 MAIN BAY OF ICT-1 SIEMENS 6MD66 V04.83.03 BU(MICOM P442), 64T(SIEMENS 7SJ804), 67 HV(SIEMENS 7SJ804), 67LV (SIEMENS 7SJ804) ,87T(SIEMENS 7UT613), 99 LV(SIEMENS 7RW80)
SIEMENS DIGSI V4.90 404 MAIN BAY OF ROURKELA LINE-1 SIEMENS 6MD66 V04.83.03 21.1(SIEMENS SIPROTEC 7SA522),21.2 (MICOM P444)
SIEMENS DIGSI V4.90 405 TIE BAY OF ROURKELA LINE-1 AND ICT-II SIEMENS 6MD66 V04.83.03 LBB 50Z (SIEMENS SIPROTEC 7VK61)
SIEMENS DIGSI V4.90 406 MAIN BAY OF ICT-II SIEMENS 6MD66 V04.83.03 BU(MICOM P442), 64T(SIEMENS 7SJ804), 67 HV(SIEMENS 7SJ804), 67LV (SIEMENS 7SJ804) ,87T(SIEMENS 7UT613), 99 LV(SIEMENS 7RW80)
ALSTOM SCE 5.12.1.0-BUILD4-RC(DS AGILE) 407 MAIN BAY OF JAMSHEDPUR-II LINE ALSTOM MICOM C264 C264 5.0.4.1-build08 21.1(MICOM P444),21.2 (REL 670)
ALSTOM SCE 5.12.1.0-BUILD4-RC(DS AGILE) 408 TIE BAY OF JAMSHEDPUR LINE-1 AND FUTURE BAY ALSTOM MICOM C264 C264 5.0.4.1-build08 LBB 50 BF MICOM P442
ALSTOM SCE 5.12.1.0-BUILD4-RC(DS AGILE) 409 FUTURE BAY ALSTOM MICOM C264 C264 5.0.4.1-build08 NIL
SIEMENS DIGSI V4.90 410 MAIN BAY OF ROURKELA LINE-II SIEMENS 6MD66 V04.83.03 21.1(MICOM P444),21.2 (REL 670)
SIEMENS DIGSI V4.90 411 TIE BAY OF ROURKELA LINE-II AND BR-I SIEMENS 6MD66 V04.83.03 LBB 50Z (SIEMENS SIPROTEC 7VK61)
SIEMENS DIGSI V4.90 412 MAIN BAY OF BR-I SIEMENS 6MD66 V04.83.03 21R (SIEMENS 7SA522), 64R(SIEMENS 7SJ804), ,87R(SIEMENS 7UT613),
SIEMENS DIGSI 5 V7.00 BCU PERFORMANCE IS NOT SATISFACTORY , FREQUENTLY HANGS AFTER RESTARTING 413 MAIN BAY OF KHARAGPUR LINE-I SIEMENS SIEMENS 6MD86 V06.20 21.1(SIEMENS SIPROTEC 7SA522),21.2 (MICOM P444), 21R (SIEMENS 7SA522), 64R(SIEMENS 7SJ804), ,87R(SIEMENS 7UT613)
SIEMENS DIGSI 5 V7.00 414 TIE BAY OF KHARAGPUR LINE-I AND BR-II SIEMENS SIEMENS 6MD86 V06.20 LBB 50Z (SIEMENS SIPROTEC 7VK61)
SIEMENS DIGSI 5 V7.00 415 MAIN BAY OF BR-II SIEMENS SIEMENS 6MD86 V06.20 21 R (MICOM P442), 64R (P141), 87R (P643), DGA ONLINE, FOS
SIEMENS DIGSI 5 V7.00 416 MAIN BAY OF KHARAGPUR LINE-II SIEMENS SIEMENS 6MD86 V06.20 21.1(SIEMENS SIPROTEC 7SA522),21.2 (MICOM P444), 21R (SIEMENS 7SA522), 64R(SIEMENS 7SJ804), ,87R(SIEMENS 7UT613), DGA SERVERON
SIEMENS DIGSI 5 V7.00 417 TIE BAY OF KHARAGPUR LINE-II AND FUTURE BAY SIEMENS SIEMENS 6MD86 V06.20 LBB 50Z (SIEMENS SIPROTEC 7VK61)
SIEMENS DIGSI 5 V7.00 418 FUTURE BAY SIEMENS SIEMENS 6MD86 V06.20 NIL
SIEMENS DIGSI V4.90 201 BUS COUPLER BAY SIEMENS SIEMENS 6MD66 V04.83.03 NIL
SIEMENS DIGSI V4.90 202 MAIN BAY OF JUSNL LINE-I SIEMENS SIEMENS 6MD66 V04.83.03 21.1(SIEMENS SIPROTEC 7SA522),21.2 (MICOM P546)
SIEMENS DIGSI V4.90 203 MAIN BAY OF JUSNL LINE-II SIEMENS SIEMENS 6MD66 V04.83.03 21.1(SIEMENS SIPROTEC 7SA522),21.2 (MICOM P546)
SIEMENS DIGSI V4.90 204 ICT-I BAY SIEMENS SIEMENS 6MD66 V04.83.03 NIL
SIEMENS DIGSI V4.90 205 TBC BAY SIEMENS SIEMENS 6MD66 V04.83.03 NIL
SIEMENS DIGSI V4.90 REMOVED FOR REPAIR DUE TO CURRENT NOT SHOWING IN B-PH 206 ICT-II BAY SIEMENS SIEMENS 6MD66 V04.83.03 NIL
SIEMENS DIGSI V4.90 INSTALLED IN 206 BAY 208 FUTURE BAY SIEMENS SIEMENS 6MD66 V04.83.03 21.1(SIEMENS SIPROTEC 7SA522),21.2 (MICOM P444)
SIEMENS DIGSI V4.90 209 FUTURE BAY SIEMENS SIEMENS 6MD66 V04.83.03 21.1(SIEMENS SIPROTEC 7SA522),21.2 (MICOM P444)
* Implemented SAS architecture to be attached
Data required for SAS upgradation in ER
Sl.No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
1 ER-1 400 KV GIS CHANDWA ABB 9.4_1 403 N.KARNPURA-1 ABB REC 670 I1631006 1.4_77m_54 ABB-RED670 , Other Panel-4R3B - ABB-RED670 & SIEMENS-7VK61
404 B/R-1 ABB REC 670 I1438009 1.4_77m_53 ABB-RET670 , Other Panel-4R4B - ABB-RET670 & SIEMENS-7VK61
405 B/R-2 ABB REC 670 I1438008 1.4_77m_53 ABB-RET670 , Other Panel-4R5B - ABB-RET670 & SIEMENS-7VK61
406 N.KARNPURA-2 ABB REC 670 I1631005 1.4_77m_54 ABB-RED670 , Other Panel-4R6B - ABB-RED670 & SIEMENS-7VK61
407 BUS-COUPLER ABB REC 670 I1438019 1.4_77m_53 SIEMENS-7VK61
408 GAYA-1 ABB REC 670 I1437044 1.4_77m_53 SIEMENS-7SA52 , Other Panel-4R8B - ABB -REL670 & SIEMENS-7VK61
409 GAYA-2 ABB REC 670 I1437045 1.4_77m_53 SIEMENS-7SA52 , Other Panel-4R8B - ABB -REL670 & SIEMENS-7VK61
410 RANCHI-1 ABB REC 670 I1437047 1.4_77m_53 SIEMENS-7SA52 , Other Panel-4R8B - ABB -REL670 & SIEMENS-7VK61
411 RANCHI-2 ABB REC 670 I1437046 1.4_77m_53 SIEMENS-7SA52 , Other Panel-4R8B - ABB -REL670 & SIEMENS-7VK61
* Implemented SAS architecture to be attached
Data required for SAS upgradation in ER
Sl. No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
1 ER-1 400/220/132 kV Daltonganj Substation GE dsagile-v5.1.21.3-base 405 Tie Bay of ICT-2 & Future GE BCU_C264 C264 5.1.27.0 P743_50BF E2.4 A
3 407 Main Bay of Sasaram-1 GE BCU_C264 C264 5.1.27.0 P444_21M1 REL670_21M2 P141_64R P442_21R P643_87R D4.4A REL670 Ver.1.1 Rev 01 P 141 6A 460 C D4.4A P 643 6 040 E
4 408 Tie Bay of ICT-1 & Sasaram-1 GE BCU_C264 C264 5.1.27.0 P743_50BF E2.4 A
6 410 Main Bay of Sasaram-2 GE BCU_C264 C264 5.1.27.0 P444_21M1 REL670_21M2 P141_64R P442_21R P643_87R D4.4A REL670 Ver.1.1 Rev 01 P 141 6A 460 C D4.4A P 643 6 040 L
7 411 Tie Bay of BR-1 & Sasaram-2 GE BCU_C264 C264 5.1.27.0 P743_50BF E2.4 A
9 BB 400 KV BUSBAR - - - P141_BVM1-4BB P141_BVM2-4BB P741_CUA P741_CUB P 141 6A 460 C P 141 6A 460 C E2.4 A E2.4 A
13 204 GARHWA-I GE BCU_C264 C264 5.1.27.0 P444_21M1 REL670_21M2 D4.4A REL670 Ver.1.1 Rev 01
15 206 GARHWA-II GE BCU_C264 C264 5.1.27.0 P444_21M1 REL670_21M2 D4.4A REL670 Ver.1.1 Rev 01
16 208 LATEHAR-I GE BCU_C264 C264 5.1.27.0 P444_21M1 REL670_21M2 D4.4A REL670 Ver.1.1 Rev 01
18 210 LATEHAR-II GE BCU_C264 C264 5.1.27.0 P444_21M1 REL670_21M2 D4.4A REL670 Ver.1.1 Rev 01
20 BB 220 KV BUSBAR - - - P741_CUA BVM2_2BB E2.4 A P 141 6A 460 C
21 101 ATR-II GE BCU_C264 C264 5.1.27.0
24 104 CHHATARPUR-II GE BCU_C264 C264 5.1.27.0 P442_21 P141_6767N P442 6A 710 C P141 6A 460 C
28 BB 132 KV BUSBAR - P741_CUA 51 J
29 AUX-BCU GE AUXBCU C264 5.1.27.0 - -
30 AUXT-BCU GE AUXBCUT C264 5.1.27.0 - -
* Implemented SAS architecture to be attached
Data required for SAS upgradation in ER
Sl.No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
GAYA SIEMENS PAS V8.05 WINCC K7.3.0.1 701 765KV BR-1 SIEMENS 6MD66315EB900AA0 V4.82.04 64 BPH/64 RPH/64 YPH/64 SPH-7SJ804, 87.1R/87R TEE-7UT613, BCU 2-6MD633, 21R-7SA522,
702 TIE BAY SIEMENS 6MD66315EB900AA0 V4.82.04
703 765/400KV ICT-1 HV SIEMENS 6MD66315EB920AA0 V4.82.04 64T.2B/64T.2SP/64T.2Y-7SJ804, 67HV & 67IV-7SJ804, BCU 2-6MD663, 87.1T/64T.2R-7UT613, 21HV&IV-P442
704 765KV BR-1 SIEMENS 6MD66315EB900AA0 V4.83.01 64 BPH/64 RPH/64 YPH/64 SPH-7SJ804, 87.1R/87R TEE-7UT613, BCU 2-6MD633, 21R-7SA522,
705 TIE BAY SIEMENS 6MD66315EB900AA0 V4.82.04
706 765/400KV ICT-2 HV SIEMENS 6MD66315EB920AA0 V4.82.04 64T.2B/64T.2Y-7SJ804, BCU 2-6MD663, 87.1T/64T.2R-7UT613, 67HV & 67IV-7SJ804, 21HV&IV-P442
707 BALLIA LINE SIEMENS 6MD66315EB900AA1 V4.82.04 MAIN 1-7SA522, MAIN 2-REL670
707R BALLIA LR SIEMENS 6MD66315EB920AA0 V4.82.04 21R.1-7SA522, 87R.1-7UT613, BCU 2-6MD663, 64R.2-7SJ804, 50Z LBB-7SS525
708 TIE BAY SIEMENS 6MD66315EB900AA1 V4.82.04
709 765/400KV ICT-3 HV SIEMENS 6MD66315EB920AA0 V4.82.04 64T.2B/64T.2Y-7SJ804, 67HV & 67IV-7SJ804, BCU 2-6MD663, 87.1T/64T.2R-7UT613 , 21HV&IV-P442
710 VARANASI-1 LINE SIEMENS 6MD66315EB900AA1 V4.82.04 MAIN 1-7SA522, MAIN 2-REL670
710R VARANASI LR 1 SIEMENS 6MD66315EB900AA0 V4.82.04 21R.1-7SA522, 87R.1-7UT613, BCU 2-6MD663, 64R.2-7SJ804
711 TIE BAY SIEMENS 6MD66315EB900AA1 V4.82.04
712 765/400KV ICT-4 HV SIEMENS 6MD66315EB900AA1 V4.82.04 BCU 2-6MD663, 51NS-P141, 64REF-P643, 87T-P645, 21HV&21LV-P442
713 VARANASI-2 LINE SIEMENS 6MD66315EB900AA1 V4.82.04 MAIN 1-7SA522, MAIN 2-P444
713R VARANASI LR 2 SIEMENS 6MD66315EB920AA0 V4.83.01 21R.1-7SA522, 87R.1-7UT613, BCU 2-6MD663, 64R.2-7SJ804, 50Z LBB-7SS525
714 TIE BAY SIEMENS 6MD66315EB900AA1 V4.82.04
1 ER1 401 765/400KV ICT-1 IV SIEMENS 6MD66315EB900AA0 V4.82.04 BCU2-6MD633
402 TIE BAY SIEMENS 6MD66315EB900AA1 V4.83.01
403 KODERMA 2 LINE SIEMENS 6MD66315EB900AA1 V4.82.04 MAIN 1-7SA522, MAIN 2-REL670
404 765/400KV ICT-2 IV SIEMENS 6MD66315EB900AA0 V4.82.04 BCU2-6MD633
405 TIE BAY SIEMENS 6MD66315EB900AA1 V4.82.04
406 KODERMA 1 LINE SIEMENS 6MD66315EB900AA1 V4.82.04 MAIN 1-7SA522, MAIN 2-REL670
407 765/400KV ICT-3 IV SIEMENS 6MD66315EB900AA0 V4.82.04 BCU2-6MD633
408 TIE BAY SIEMENS 6MD66315EB900AA1 V4.82.04
409 MAITHON 2 LINE SIEMENS 6MD66315EB900AA1 V4.82.04 MAIN 1-7SA522, MAIN 2-REL670
409R MAITHON 2 LR SIEMENS 6MD66315EB900AA0 V4.82.04 21.2R-7SA522, 64.2R-7SJ804, 87.1R-7UT613
410 765/400KV ICT-4 IV SIEMENS 6MD66315EB900AA1 V4.82.04 BCU2-6MD633
411 TIE BAY SIEMENS 6MD66315EB900AA1 V4.82.04
412 MAITHON 1 LINE SIEMENS 6MD66315EB900AA1 V4.82.04 MAIN 1-7SA522, MAIN 2-REL670
412R MAITHON 1 LR SIEMENS 6MD66315EB900AA0 V4.82.04 21.2R-7SA522, 64.2R-7SJ804, 87.1R-7UT613
414 TIE BAY SIEMENS 6MD66315EB900AA1 V4.71.03
415 CHANDWA 1 LINE SIEMENS 6MD66315EB900AA1 V4.81.03 MAIN 1-7SA522, MAIN 2-P444
416 400/220KV ICT-1 HV SIEMENS 6MD66315EB900AA0 V4.82.04 87.1T/64.1T-7UT613, 67HV&67IV-7SJ804, 21HV-P442
417 TIE BAY SIEMENS 6MD66315EB900AA1 V4.71.03 50ZT-7SS525
418 CHANDWA 2 LINE SIEMENS 6MD66315EB900AA1 V4.81.03 MAIN 1-7SA522, MAIN 2-P444
419 400KV BR-1 SIEMENS 6MD66315EB900AA0 V4.82.04 21.2R-7SA522, 64.2R-7SJ804, 87.1R/87.1TEE-7UT613
420 TIE BAY SIEMENS 6MD66315EB900AA1 V4.82.04
421 NABINAGAR 2 LINE SIEMENS 6MD66315EB900AA1 V4.81.03 MAIN 1-7SA522, MAIN 2-P444
422 400KV BR-2 SIEMENS 6MD66315EB900AA0 V4.82.04 21.2R-7SA522, 64.2R-7SJ804, 87.1R/87.1TEE-7UT613
423 TIE BAY SIEMENS 6MD66315EB900AA1 V4.82.04
424 NABINAGAR 1 LINE SIEMENS 6MD66315EB900AA1 V4.81.03 MAIN 1-7SA522, MAIN 2-P444
425 400/220KV ICT-2 HV SIEMENS 6MD66315EB900AA0 V4.82.04 87.1T/64.1T-7UT613, 67HV&67IV-7SJ804, 21HV-P442
426 TIE BAY SIEMENS 6MD66315EB900AA1 V4.82.04
427 NKSTPS LINE-1 GE C264 C264_5.0.4.1 MAIN 1-P444, MAIN 2-D60
429 TIE BAY GE C264 C264_5.0.4.1 50BF-P442
430 NKSTPS LINE-2 GE C264 C264_5.0.4.1 MAIN 1-P444, MAIN 2-D60
201 400/220KV ICT-1 IV SIEMENS 6MD66315EB900AA0 V4.82.04
202 TBC SIEMENS 6MD66315EB900AA1 V4.82.04
203 BUS COUPLER SIEMENS 6MD66315EB900AA0 V4.81.03 BCU 2-7SJ804
204 BODHGAYA-2 SIEMENS 6MD66315EB900AA1 V4.81.03 MAIN 1-7SA522, MAIN 2-REL670
205 400/220KV ICT-2 IV SIEMENS 6MD66315EB900AA0 V4.82.04
206 BODHGAYA-1 SIEMENS 6MD66315EB900AA1 V4.81.03 MAIN 1-7SA522, MAIN 2-REL670
207 KHIZERSARAI-1 SIEMENS 6MD86DAAAAA0 V07.31 MAIN 1-7SA522, 81-7SJ803, MAIN 2-P444
208 DEHRI-2 SIEMENS 6MD66315EB900AA1 V4.81.03 MAIN 1-7SA522, MAIN 2-REL670
209 DEHRI-1 SIEMENS 6MD66315EB900AA1 V4.81.03 MAIN 1-7SA522, MAIN 2-REL670
210 KHIZERSARAI-2 SIEMENS 6MD86DAAAAA0 V07.31 MAIN 1-7SA522, 81-7SJ803, MAIN 2-P444
211 SONENAGAR-1 SIEMENS 6MD86DAAAAA0 V07.31 MAIN 1-7SA522, MAIN 2-P444
212 SONENAGAR-2 SIEMENS 6MD86DAAAAA0 V07.31 MAIN 1-7SA522, MAIN 2-P444
* Implemented SAS architecture to be attached
Name of Sub station JHARSUGUDA
Sl No Description Remarks
1 SAS make SIEMENS
4 SAS Operating system Windows version WINDOWS 7 PROFESSIONAL
1 SAS Server software version PAS Version-V8.03
WinCC Version- V7.0+SP3+uPD6
SCC Version-8.02
List of IEDs(Baywise) along with their version no.
Sl No Bay name Bay NO IED Description(distance/diff/etc) MLFB No Firmware version
1 Main Bay of 400kV Sundargarh-Raigarh Ckt#2 401 Distance Protection Main-1 7SA52216CB904QB4 V04.70.07
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.82.05
2 Tie Bay of 400kV Sundargarh-Raigarh Ckt#2 & ICT#1 402 Bay Control Unit 6MD66315EB900AA1 V04.82.05
3 Main Bay of 400kV side ICT#1 403 Bay Control Unit-1 6MD66315EB900AA0 V04.82.05
Bay Control Unit-2 6MD63315EB900AA0 V04.66.04
4 Main Bay of 400kV Sundargarh-Rourkela Ckt#2 404 Distance Protection Main-1 7SA52216CB904QB4 V04.71.03
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.82.05
5 Tie Bay of 400kV Sundargarh-Rourkela Ckt#2 & ICT#2 405 Bay Control Unit 6MD66315EB900AA1 V04.82.05
6 Main Bay of 400kV side ICT#2 406 Bay Control Unit-1 6MD66315EB900AA0 V04.82.05
Bay Control Unit-2 6MD63315EB900AA0 V04.66.04
7 Main Bay of 400kV Sundargarh-Raigarh Ckt#1 407 Distance Protection Main-1 7SA52216CB904QB4 V04.70.07
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.82.05
8 Tie Bay of 400kV Sundargarh-Raigarh Ckt#1 & Future Bay 408 Bay Control Unit 6MD66315EB900AA1 V04.83.03
9 Future Bay 409 Bay Control Unit 6MD66315EB900AA0 V04.82.05
10 Main Bay of 400kV Sundargarh-Rourkela Ckt#1 410 Distance Protection Main-1 7SA52216CB904QB4 V04.70.07
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.83.03
11 Tie Bay of 400kV Sundargarh-Rourkela Ckt#1 & Future Bay 411 Bay Control Unit 6MD66315EB900AA1 V04.82.05
12 Future Bay 412 Bay Control Unit 6MD66315EB900AA0 V04.82.05
13 Main Bay of 400kV Bus Reactor-I 413 Differential Protection 7UT61316EB921AA0 V04.63.01
REF Protection 7SJ80425EB901FC0 V04.74.05
Back-up Impedance Protection 7SA52216AB900EA0 V04.70.07
Bay Control Unit 6MD66315EB900AA0 V04.82.05
14 Tie Bay of 400kV Bus Reactor-I & 400kV Sterlite Ckt#1 414 Bay Control Unit 6MD66315EB900AA1 V04.82.05
15 Main Bay of 400kV Sundargarh-Sterlite Ckt#1 415 Distance Protection Main-1 7SA52216CB904QB4 V04.74.02
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.82.05
16 Main Bay of 400kV Bus Reactor-II 416 Differential Protection 7UT61316EB921AA0 V04.63.01
REF Protection 7SJ80425EB901FC0 V04.63.05
Back-up Impedance Protection 7SA52216AB900EA0 V04.70.07
Bay Control Unit 6MD66315EB900AA0 V04.82.05
17 Tie Bay of 400kV Bus Reactor-II & 400kV Sterlite Ckt#2 417 Bay Control Unit 6MD66315EB900AA1 V04.82.05
18 Main Bay of 400kV Sundargarh-Sterlite Ckt#2 418 Distance Protection Main-1 7SA52216CB904QB4 V04.74.02
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.82.05
19 Tie Bay of 400kV Sundargarh-IBEUL Ckt#1 & Future Bay 420 Bay Control Unit 6MD66315EB900AA1 V04.84.02
20 Main Bay of 400kV Sundargarh-IBEUL Ckt#1 421 Distance Protection Main-1 7SA52216CB904QB4 V04.72.01
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.84.02
21 Tie Bay of 400kV Sundargarh-IBEUL Ckt#2 & Future Bay 423 Bay Control Unit 6MD66315EB900AA1 V04.83.03
22 Main Bay of 400kV Sundargarh-IBEUL Ckt#2 424 Distance Protection Main-1 7SA52216CB904QB4 V04.72.01
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.83.03
23 Main Bay of 765kV Bus Reactor-I 701 Differential Protection Main-1 7UT61316EB921AA0 V04.63.01
Differential Protection Main-2 7UT61316EB921AA0 V04.63.01
REF Protection-Rph 7SJ80425EB901FC0 V04.63.05
REF Protection-Yph 7SJ80425EB901FC0 V04.63.05
REF Protection-Bph 7SJ80425EB901FC0 V04.63.05
REF Protection-Sp ph 7SJ80425EB901FC0 V04.63.05
Back-up Impedance Protection 7SA52216AB900EA0 V04.70.07
Bay Control Unit-1 6MD63315EB900AA0 V04.82.05
Bay Control Unit-2 6MD63315EB920AA0 V04.66.04
24 Tie Bay of 765kV Bus Reactor-I & ICT#1 702 Bay Control Unit 6MD63315EB900AA0 V04.82.05
25 Main Bay of 765kV Side ICT#1 703 Differential Protection 7UT61316EB921AB0 V04.63.01
REF Protection-Rph 7UT61316EB921BB0 V04.63.01
REF Protection-Yph 7SJ80425EB901FC0 V04.63.05
REF Protection-Bph 7SJ80425EB901FC0 V04.63.05
REF Protection-Sp ph 7SJ80425EB901FC0 V04.63.05
Overflux HV 7SJ80425EB901FC0 V04.63.05
Overflux IV 7SJ80425EB901FC0 V04.63.01
Bay Control Unit-1 6MD66315EB920AA0 V04.82.05
Bay Control Unit-2 6MD66315EB920AA0 V04.82.05
26 Main Bay of 765kV Bus Reactor-II 704 Differential Protection Main-1 7UT61316EB921AA0 V04.63.01
Differential Protection Main-2 7UT61316EB921AA0 V04.63.01
REF Protection-Rph 7SJ80425EB901FC0 V04.63.05
REF Protection-Yph 7SJ80425EB901FC0 V04.63.05
REF Protection-Bph 7SJ80425EB901FC0 V04.63.05
REF Protection-Sp ph 7SJ80425EB901FC0 V04.63.05
Back-up Impedance Protection 7SA52216AB900EA0 V04.70.07
Bay Control Unit-1 6MD63315EB900AA0 V04.82.05
Bay Control Unit-2 6MD63315EB920AA0 V04.66.04
27 Tie Bay of 765kV Bus Reactor-II & ICT#2 705 Bay Control Unit 7UT61316EB921AB0 V04.82.05
28 Main Bay of 765kV Side ICT#2 706 Differential Protection 7SJ80425EB901FC0 V04.63.01
REF Protection-Rph 7UT61316EB921BB0 V04.63.01
REF Protection-Yph 7SJ80425EB901FC0 V04.63.05
REF Protection-Bph 7SJ80425EB901FC0 V04.63.05
Overflux HV 7SJ80425EB901FC0 V04.63.01
Overflux IV 7SJ80425EB901FC0 V04.63.01
Bay Control Unit-1 6MD66315EB920AA0 V04.82.05
Bay Control Unit-2 6MD66315EB920AA0 V04.8205
29 Main Bay of 765kV Sundargarh-Angul Ckt#4 With Line Reactor 707 Distance Protection Main-1 7SA52216CB904QB4 V04.70.07
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.8303
Differential Protection 7UT61316EB921AA0 V04.63.01
REF Protection 7SJ80425EB901FC0 V04.63.05
Back-up Impedance Protection 7SA52216AB900EA0 V04.70.07
Bay Control Unit 6MD63315EB900AA0 V04.82.05
30 Tie Bay of 765kV Sundargarh-Angul Ckt#4 & 765kV Sundargarh-Raipur Ckt#1 708 Bay Control Unit 6MD66315EB900AA1 V04.82.05
31 Main Bay of 765kV Sundargarh-Raipur Ckt#1 (Future) 709 Distance Protection Main-1 Future Future
32 Distance Protection Main-2
Bay Control Unit
Differential Protection
Back-up Impedance Protection
Bay Control Unit
32 Main Bay of 765kV Sundargarh-Angul Ckt#3 With Line Reactor 710 Distance Protection Main-1 7SA52216CB904QB4 V04.70.07
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.8303
Differential Protection 7UT61316EB921AA0 V04.63.01
REF Protection 7SJ80425EB901FC0 V04.63.05
Back-up Impedance Protection 7SA52216AB900EA0 V04.70.07
Bay Control Unit 6MD63315EB900AA0 V04.82.05
33 Tie Bay of 765kV Sundargarh-Angul Ckt#3 & 765kV Sundargarh-Raipur Ckt#2 711 Bay Control Unit 6MD66315EB900AA1 V04.83.03
34 Main Bay of 765kV Sundargarh-Raipur Ckt#2 (Future) 712 Distance Protection Main-1 Future Future
32 Distance Protection Main-2
Bay Control Unit
Differential Protection
Back-up Impedance Protection
Bay Control Unit
35 Main Bay of 765kV Sundargarh-Angul Ckt#2 With Line Reactor 713 Distance Protection Main-1 7SA52216CB904QB4 V04.73.03
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.84.02
Differential Protection 7UT61316EB921AA0 V04.65.02
REF Protection 7SJ80425EB901FC0 V04.63.05
Back-up Impedance Protection 7SA52216AB900EA0 V04.73.03
Bay Control Unit 6MD63315EB900AA0 V04.84.02
36 Tie Bay of 765kV Sundargarh-Angul Ckt#2 & 765kV Sundargarh-Dharamjaygarh Ckt#3 714 Bay Control Unit 6MD66315EB900AA1 V04.82.05
37 Main Bay of 765kV Sundargarh-Dharamjaygarh Ckt#3 715 Distance Protection Main-1 7SA52216CB904QB4 V04.70.07
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.84.02
38 Main Bay of 765kV Sundargarh-Angul Ckt#1 With Line Reactor 716 Distance Protection Main-1 7SA52216CB904QB4 V04.73.03
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.84.02
Differential Protection 7UT61316EB921AA0 V04.65.02
REF Protection 7SJ80425EB901FC0 V04.74.05
Back-up Impedance Protection 7SA52216AB900EA0 V04.73.03
Bay Control Unit 6MD63315EB900AA0 V04.83.03
39 Tie Bay of 765kV Sundargarh-Angul Ckt#1 & 765kV Sundargarh-Dharamjaygarh Ckt#4 717 Bay Control Unit 6MD66315EB900AA1 V04.82.05
40 Main Bay of 765kV Sundargarh-Dharamjaygarh Ckt#4 718 Distance Protection Main-1 7SA52216CB904QB4 V04.70.07
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.83.03
41 Main Bay of 765kV Sundargarh-NTPC Ckt#2 719 Distance Protection Main-1 7SA52216CB904QB4 V04.73.03
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.83.03
42 Tie Bay of 765kV Sundargarh-NTPC Ckt#2 & 765kV Sundargarh-Dharamjaygarh Ckt#1 720 Bay Control Unit 6MD66315EB900AA1 V04.83.03
LBB Protection 7VK61016AB924YC0 V04.71.02
43 Main Bay of 765kV Sundargarh-Dharamjaygarh Ckt#1 721 Distance Protection Main-1 7SA52216CB904QB4 V04.73.03
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.84.02
44 Main Bay of 765kV Sundargarh-NTPC Ckt#1 722 Distance Protection Main-1 7SA52216CB904QB4 V04.73.03
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.84.02
45 Tie Bay of 765kV Sundargarh-NTPC Ckt#1 & 765kV Sundargarh-Dharamjaygarh Ckt#2 723 Bay Control Unit 6MD66315EB900AA1 V04.83.03
LBB Protection 7VK61016AB924YC0 V04.71.02
46 Main Bay of 765kV Sundargarh-Dharamjaygarh Ckt#2 724 Distance Protection Main-1 7SA52216CB904QB4 V04.73.03
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit 6MD66315EB900AA1 V04.83.03
47 For 400kV BUS CVT Measurement Bay Control Unit 7SJ80415EB901FC0 V04.63.05
Bay Control Unit 7SJ80415EB901FC0 V04.63.05
48 400kV Busbar Protection Master Control Unit-1 7SS52205AB921CA0 V04.72.01
Master Control Unit-2 7SS52205AB921CA0 V04.72.01
49 For 765kV BUS CVT Measurement Bay Control Unit 7SJ80415EB901FC0 V04.63.05
Bay Control Unit 7SJ80415EB901FC0 V04.63.05
50 765kV Busbar Protection Master Control Unit-1 7SS52205AB921CA0 V04.72.01
Master Control Unit-2 7SS52205AB921CA0 V04.72.01
51 LT System Bay Control Unit-1 6MD63315EB900AA0 V04.66.04
Bay Control Unit-2 6MD63315EB900AA0 V04.66.04
Bay Control Unit-3 6MD63315EB900AA0 V04.66.04
Bay Control Unit-4 6MD63315EB900AA0 V04.66.04
Bay Control Unit-5 6MD63315EB900AA0 V04.66.04
Bay Control Unit-6 6MD63315EB900AA0 V04.66.04
Bay Control Unit-7 6MD63315EB900AA0 V04.66.04
Bay Control Unit-8 6MD63315EB900AA0 V04.66.04
52 Tertiary System Earth Fault Protection 7SJ80415EB901FC0 V04.73.02
Bay Control Unit 6MD63315EB900AA0 V04.66.04
Name of Sub station JHARSUGUDA
Sl No Description Remarks
4 SAS Operating system Windows version WINDOWS 7 PROFESSIONAL
1 SAS Server software version DS Agile- V5.1.21.3-Base
List of IEDs(Baywise) along with their version no.
Sl No Bay name Bay NO IED Description(distance/diff/etc) MLFB No Firmware version
1 400kV Bus Sectionalizer-2 425 Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
2 400kV Bus Sectionalizer-1 426 Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
3 Main Bay of 400kV Sundargarh-Raigarh Ckt#4 427 Distance Protection Main-1 P444916J6M0720M P444___6A_720_B
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
4 Tie Bay of 400kV Sundargarh-Raigarh Ckt#4 & 400kV Sundargarh-Rourkela Ckt#4 428 Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
5 Main Bay of 400kV Sundargarh-Rourkela Ckt#4 429 Distance Protection Main-1 P444916J6M0720M P444___6A_720_B
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
6 Main Bay of 400kV Sundargarh-Raigarh Ckt#3 430 Distance Protection Main-1 P444916J6M0720M P444___6A_720_B
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
7 Tie Bay of 400kV Sundargarh-Raigarh Ckt#3 & 400kV Sundargarh-Rourkela Ckt#3 431 Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
8 Main Bay of 400kV Sundargarh-Rourkela Ckt#3 432 Distance Protection Main-1 P444916J6M0720M P444___6A_720_B
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
9 Main Bay of 400kV Sundargarh-OPGC Ckt#1 433 Distance Protection Main-1 P444916J6M0720M P444___6A_720_B
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
10 Tie Bay of 400kV Sundargarh-OPGC Ckt#1 & 400kV Side of ICT#4 434 Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
11 Main Bay of 400kV Side of ICT#4 435 Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P4442916B6M0710M P442___6A_710_C
12 Main Bay of 400kV Side of ICT#3 436 Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
13 Tie Bay of 400kV Sundargarh-OPGC Ckt#2 & 400kV Side of ICT#3 437 Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
14 Main Bay of 400kV Sundargarh-OPGC Ckt#2 438 Distance Protection Main-1 P444916J6M0720M P444___6A_720_B
Distance Protection Main-2 REL670 L67I11Ver 1.1.01_IEC
Bay Control Unit C264MB1M69100130 84000030001N10 C264-5.1.27.0-BUILD02
LBB Protection P442916B6M0710M P442___6A_710_C
15 400kv GIS Busbar Protection Busbar Protection Main-1 Rph P747916A6M0030K P747___6_030_G
Busbar Protection Main-1 Yph P747916A6M0030K P747___6_030_G
Busbar Protection Main-1 Bph P747916A6M0030K P747___6_030_G
Busbar Protection Main-2 Rph P747916A6M0030K P747___6_030_G
Busbar Protection Main-2 Yph P747916A6M0030K P747___6_030_G
Busbar Protection Main-2 Bph P747916A6M0030K P747___6_030_G
Data to be provided to CC-Engineering for making DPR for Upgradation of RTU/SAS for data reporting to ERLDC main and back up Control centre over 104 Protocol
Name of Sub station
Sl No Description Remarks
1 SAS make SIEMENS
2 Station Latest SLD Pls enclose the latest SLD
3 SA Architecture(Latest) Pls enclose the SA architecture(Latest)
4 SAS Operating system Windows version WINDOW XP
5 SAS Server software version Pls Fill up section B
6 List of all IEDs(baywise) along with their version no. Pls Fill up section C
SAS Server details
Sl No Description
1 SAS Server software version
2 Nos of present extension
3 Nos of addition of future IED possible to existing server
List of IEDs(Baywise) along with their version no.
Sl No Bay name Bay NO IED Description(distance/diff/etc) MLFB No Firmware version
2 Station latest SLD
3 SA architecture (latest)
4 SAS Server software version
5 SAS Operating system Windows version:
Prepared by List of all IEDS (bay wise) alongwith their version no.
Data to be provided to CC-Engineering for making DPR for Upgradation of RTU/SAS for data reporting to ERLDC main and back up Control centre over 104 Protocol
Name of Sub station
Sl No Description Remarks
1 SAS make SIEMENS
2 Station Latest SLD Pls enclose the latest SLD
3 SA Architecture(Latest) Pls enclose the SA architecture(Latest)
4 SAS Operating system Windows version WINDOWS 7 PROFESSIONAL
5 SAS Server software version Pls Fill up section B
6 List of all IEDs(baywise) along with their version no. Pls Fill up section C
SAS Server details
Sl No Description
1 SAS Server software version
2 Nos of present extension
3 Nos of addition of future IED possible to existing server
List of IEDs(Baywise) along with their version no.
Sl No Bay name Bay NO IED Description(distance/diff/etc) MLFB No Firmware version
2 Station latest SLD
3 SA architecture (latest)
4 SAS Server software version
5 SAS Operating system Windows version:
Prepared by List of all IEDS (bay wise) alongwith their version no.
Data to be provided to CC-Engineering for making DPR for Upgradation of RTU/SAS for data reporting to ERLDC main and back up Control centre over 104 Protocol
Name of Sub station
Sl No Description Remarks
1 SAS make SIEMENS
2 Station Latest SLD Pls enclose the latest SLD
3 SA Architecture(Latest) Pls enclose the SA architecture(Latest)
4 SAS Operating system Windows version Window XP
5 SAS Server software version Pls Fill up section B
6 List of all IEDs(baywise) along with their version no. Pls Fill up section C
SAS Server details
Sl No Description
1 SAS Server software version
2 Nos of present extension
3 Nos of addition of future IED possible to existing server
List of IEDs(Baywise) along with their version no.
Sl No Bay name Bay NO IED Description(distance/diff/etc) MLFB No Firmware version
2 Station latest SLD
3 SA architecture (latest)
4 SAS Server software version
5 SAS Operating system Windows version:
Prepared by List of all IEDS (bay wise) alongwith their version no.
Data to be provided to CC-Engineering for making DPR for Upgradation of RTU/SAS for data reporting to ERLDC main and back up Control centre over 104 Protocol
Name of Sub station
Sl No Description Remarks
1 SAS make SIEMENS
2 Station Latest SLD Pls enclose the latest SLD
3 SA Architecture(Latest) Pls enclose the SA architecture(Latest)
4 SAS Operating system Windows version WINDOW7
5 SAS Server software version Pls Fill up section B
6 List of all IEDs(baywise) along with their version no. Pls Fill up section C
SAS Server details
Sl No Description
1 SAS Server software version
2 Nos of present extension
3 Nos of addition of future IED possible to existing server
List of IEDs(Baywise) along with their version no.
Sl No Bay name Bay NO IED Description(distance/diff/etc) MLFB No Firmware version
2 Station latest SLD
3 SA architecture (latest)
4 SAS Server software version
5 SAS Operating system Windows version:
Prepared by List of all IEDS (bay wise) alongwith their version no.
Data to be provided to CC-Engineering for making DPR for Upgradation of RTU/SAS for data reporting to ERLDC main and back up Control centre over 104 Protocol
Name of Sub station
Sl No Description Remarks
1 SAS make SIEMENS
2 Station Latest SLD Pls enclose the latest SLD (pdf/jpg..)
3 SA Architecture(Latest) Pls enclose the SA architecture (Latest)(pdf/jpg..)
4 SAS Operating system Windows version UNIX BASED
5 SAS Server software version Pls Fill up section B
6 List of all IEDs(baywise) along with their version no. Pls Fill up section C
SAS Server details
Sl No Description
1 SAS Server software version
2 Nos of present extension
3 Nos of addition of future IED possible to existing server
List of IEDs(Baywise) along with their version no.
Sl No Bay name Bay NO IED Description(distance/diff/etc) MLFB No Firmware version
Prepared by List of all IEDS (bay wise) alongwith their version no.
Name of Sub station Keonjhar S/s
Sl No Description Remarks
1 SAS make SIEMENS
2 SAS Operating system Windows version WINDOWS 7 PROFESSIONAL
3 SAS Server software version SICAM PAS V7.00+SP3
List of IEDs(Baywise) along with their version no.
Sl No Bay name Bay NO IED Description(distance/diff/etc) MLFB No Firmware version
1 Future Bay 403 BCU 6MD6631-5EB90-0AA1/GG V04.82.05
2 ICT-2 Main Bay 404 BCU 6MD6631-5EB90-0AA0/GG V04.82.05
87.1T(Diff. Prot) 7UT6131-6EB92-1AB0/FF V04.63.01
67.1 IV(Backup O/C) 7SJ8041-5EB90-1FC0/CC 04.63.05
67.2HV(Backup O/C) 7SJ8041-5EB90-1FC0/CC 04.70.08
64.2T(High Imp Ref.) 7UT6131-6EB92-1BB0/FF V04.63.01
87.1(LBB Bay Unit) 7SS5251-5FA01/0AA1/FF V3.3
3 ICT-2 Tie Bay 40304 BCU 6MD6631-5EB90-0AA1/GG V04.82.05
4 Rengali Line Bay 405 BCU 6MD6631-5EB90-0AA1/GG V04.82.05
Bay Unit(87.1) 7SS5251-5FA01/0AA1/FF V3.3
Bay Unit(87.2) 7SS5251-5FA01/0AA1/FF V3.3
5 Rengali Tie Bay 40506 BCU 6MD6631-5EB90-0AA1/GG V04.82.05
50ZT(LBB Prot.) 7SS5251-5FA01/1AA1/FF V3.3
6 ICT-1 Main Bay 406 BCU 6MD6631-5EB90-0AA0/GG V04.82.05
87.1T(Diff. Prot) 7UT6131-6EB92-1AB0/FF V04.63.01
67.1 IV(Backup O/C) 7SJ8041-5EB90-1FC0/CC 04.63.05
67.2HV(Backup O/C) 7SJ8041-5EB90-1FC0/CC 04.63.05
64.2T(High Imp Ref.) 7UT6131-6EB92-1BB0/FF V04.63.01
87.2(LBB Bay Unit) 7SS5251-5FA01/0AA1/EE V3.3
7 Rengali Line Bay 407 BCU 6MD6631-5EB90-0AA1/GG V04.82.05
Bay Unit(87.1) 7SS5251-5FA01/0AA1/FF V3.3
Bay Unit(87.2) 7SS5251-5FA01/0AA1/FF V3.3
8 Baripada- B/R Tie Bay 40708 BCU 6MD6631-5EB90-0AA1/GG V04.82.05
50ZT(LBB Prot.) 7SS5251-5FA01/1AA1/FF V3.3
9 Reactor Bay 408 BCU 6MD6631-5EB90-0AA0/GG V04.82.05
87.1R(Diff.) 7UT6131-6EB92-1AA0/FF V04.63.01
21.2R(Backup Imp.) 7SS5251-6AB90/0EA0/GG V04.70.07
64.2R(High Imp Ref.) 7SJ8042-5EB90-1FC0/CC 04.63.05
87.1(LBB Bay Unit) 7SS5251-5FA01/0AA1/FF V3.3
10 Bus Bar 400R MCU-1 7SS5220-5AB92/1AA0/HH V04.72.08
BCU-1 7SJ8041-5EB90-1FC0/CC 04.63.05
BCU-2 7SJ8041-5EB90-1FC0/CC 04.63.05
11 Transfer Bus Coupler Bay 201 BCU 6MD6631-5EB90-0AA1/GG V04.81.03
87BB 7SS5251-5FA01-0AA1/FF V3.3
12 Fedeer-01 202 BCU 6MD6631-5EB90-0AA1/GG V04.81.03
87BB 7SS5251-5FA01-0AA1/FF V3.3
13 ICT-I 220KV Side 203 BCU 6MD6631-5EB90-0AA0/GG V04.81.03
87BB 7SS5251-5FA01-0AA1/FF V3.3
87BB 7SS5251-5FA01-0AA1/FF V3.3
14 Fedeer-02 204 BCU 6MD6631-5EB90-0AA1/GG V04.81.03
87BB 7SS5251-5FA01-0AA1/FF V3.3
15 ICT-II 220KV Side 205 BCU 6MD6631-5EB90-0AA0/GG V04.81.03
87BB 7SS5251-5FA01-0AA1/FF V3.3
16 Fedeer-03 206 BCU 6MD6631-5EB90-0AA1/GG V04.81.03
87BB 7SS5251-5FA01-0AA1/FF V3.3
17 Bus Coupler Bay 207 BCU 6MD6631-5EB90-0AA0/GG V04.81.03
BCU-2 7SJ8041-5EB90-1FC0/CC 04.63.05
87BB 7SS5251-5FA01-0AA1/FF V3.3
18 Fedeer-04 208 BCU 6MD6631-5EB90-0AA1/GG V04.81.03
87BB 7SS5251-5FA01-0AA1/FF V3.3
19 220KV Bus bar protection 200R MCU 7SS5220-5AB92/1AA0/HH V04.72.08
20 Tertiary Bay 301 BCU 6MD6631-5EB90-0AA0/EE V04.70.00
Data required for SAS upgradation in ER
Sl.No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
1 ER1 Kishanganj SIEMENS SICAM PAS V8.04 404 Bus Reactor-1 SIEMENS 6MD86 6.20
2 ER1 Kishanganj SIEMENS SICAM PAS V8.04 405 TIE SIEMENS 6MD86 6.20
3 ER1 Kishanganj SIEMENS SICAM PAS V8.04 406 ICT-1 HV SIEMENS 6MD86 6.20
4 ER1 Kishanganj SIEMENS SICAM PAS V8.04 407 STATCOM SIEMENS 6MD86 6.20
5 ER1 Kishanganj SIEMENS SICAM PAS V8.04 408 TIE SIEMENS 6MD86 6.20
6 ER1 Kishanganj SIEMENS SICAM PAS V8.04 409 Teesta-3 L/R SIEMENS 6MD86 6.20
7 ER1 Kishanganj SIEMENS SICAM PAS V8.04 410 Teesta-3 Line SIEMENS 6MD86 6.20
8 ER1 Kishanganj SIEMENS SICAM PAS V8.04 411 Rangpo L/R SIEMENS 6MD86 6.20
9 ER1 Kishanganj SIEMENS SICAM PAS V8.04 412 Rangpo Line SIEMENS 6MD86 6.20
10 ER1 Kishanganj SIEMENS SICAM PAS V8.04 413 TIE SIEMENS 6MD86 6.20
11 ER1 Kishanganj SIEMENS SICAM PAS V8.04 414 ICT-2 HV SIEMENS 6MD86 6.20
12 ER1 Kishanganj SIEMENS SICAM PAS V8.04 415 Patna-1 L/R SIEMENS 6MD86 6.20
13 ER1 Kishanganj SIEMENS SICAM PAS V8.04 416 Patna-1 Line SIEMENS 6MD86 6.20
14 ER1 Kishanganj SIEMENS SICAM PAS V8.04 417 TIE SIEMENS 6MD86 6.20
15 ER1 Kishanganj SIEMENS SICAM PAS V8.04 418 ICT-3 Future SIEMENS 6MD86 6.20
16 ER1 Kishanganj SIEMENS SICAM PAS V8.04 419 Patna-2 L/R SIEMENS 6MD86 6.20
17 ER1 Kishanganj SIEMENS SICAM PAS V8.04 420 Patna-2 Line SIEMENS 6MD86 6.20
18 ER1 Kishanganj SIEMENS SICAM PAS V8.04 421 TIE SIEMENS 6MD86 6.20
19 ER1 Kishanganj SIEMENS SICAM PAS V8.04 422 Bus Reactor-2 SIEMENS 6MD86 6.20
20 ER1 Kishanganj SIEMENS SICAM PAS V8.04 423 NPRN-2 Line SIEMENS 6MD86 6.20
21 ER1 Kishanganj SIEMENS SICAM PAS V8.04 424 TIE SIEMENS 6MD86 6.20
22 ER1 Kishanganj SIEMENS SICAM PAS V8.04 425 NPRN-1 Line SIEMENS 6MD86 6.20
23 ER1 Kishanganj SIEMENS SICAM PAS V8.04 426 NSLG-2 Line SIEMENS 6MD86 6.20
24 ER1 Kishanganj SIEMENS SICAM PAS V8.04 427 TIE SIEMENS 6MD86 6.20
25 ER1 Kishanganj SIEMENS SICAM PAS V8.04 428 NSLG-1 Line SIEMENS 6MD86 6.20
26 ER1 Kishanganj SIEMENS SICAM PAS V8.04 429 Darbhanga-1 Line ALSTOM C264 5.0.4.1
27 ER1 Kishanganj SIEMENS SICAM PAS V8.04 429R Darbhanga-1 L/R ALSTOM C264 5.0.4.1
28 ER1 Kishanganj SIEMENS SICAM PAS V8.04 430 TIE ALSTOM C264 5.0.4.1
29 ER1 Kishanganj SIEMENS SICAM PAS V8.04 431 Future ALSTOM C264 5.0.4.1
30 ER1 Kishanganj SIEMENS SICAM PAS V8.04 432 Darbhanga-2 Line ALSTOM C264 5.0.4.1
31 ER1 Kishanganj SIEMENS SICAM PAS V8.04 432R Darbhanga-2 L/R ALSTOM C264 5.0.4.1
32 ER1 Kishanganj SIEMENS SICAM PAS V8.04 433 TIE ALSTOM C264 5.0.4.1
33 ER1 Kishanganj SIEMENS SICAM PAS V8.04 434 Future ALSTOM C264 5.0.4.1
34 ER1 Kishanganj SIEMENS SICAM PAS V8.04 201 Dalkhola-2 Line SIEMENS 6MD86 6.20
35 ER1 Kishanganj SIEMENS SICAM PAS V8.04 202 Bus Coupler SIEMENS 6MD86 6.20
36 ER1 Kishanganj SIEMENS SICAM PAS V8.04 203 Dalkhola-1 Line SIEMENS 6MD86 6.20
37 ER1 Kishanganj SIEMENS SICAM PAS V8.04 204 ICT-1 LV SIEMENS 6MD86 6.20
38 ER1 Kishanganj SIEMENS SICAM PAS V8.04 205 ICT-2 LV SIEMENS 6MD86 6.20
39 ER1 Kishanganj SIEMENS SICAM PAS V8.04 206 Siliguri-2 Line SIEMENS 6MD86 6.20
40 ER1 Kishanganj SIEMENS SICAM PAS V8.04 207 Siliguri-1 Line SIEMENS 6MD86 6.20
41 ER1 Kishanganj SIEMENS SICAM PAS V8.04 208 BSPTCL-1 SIEMENS 6MD86 6.20
42 ER1 Kishanganj SIEMENS SICAM PAS V8.04 209 BSPTCL-2 SIEMENS 6MD86 6.20
43 ER1 Kishanganj SIEMENS SICAM PAS V8.04 210 BSPTCL-3 SIEMENS 6MD86 6.20
44 ER1 Kishanganj SIEMENS SICAM PAS V8.04 211 BSPTCL-4 SIEMENS 6MD86 6.20
Implemented SAS architecture to be attached
Data required for SAS upgradation in ER
Sl.No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
1 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 401 400 Kv Biharsharif-I Main Bay ALSTOM C264MB1M6910013404000031111N10 C264.5.0.4.0-build 11 P444_21M1, REL670_21M2
2 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 402 400 Kv Biharsharif-I & ICT-I Tie Bay ALSTOM C264MB1M691021350500A030111N10 C264.5.0.4.0-build 11 P743_50BF
3 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 403 400 Kv ICT-I Main Bay ALSTOM C264MB1M691001340500A031111N10 C264.5.0.4.0-build 11 P643_87T, P141_HV, P141_LV, P643_64T
4 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 404 400 Kv Biharsharif-II Main Bay ALSTOM C264MB1M6910013303000031111N10 C264.5.0.4.0-build 11 P444_21M1, REL670_21M2
5 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 405 400 Kv Biharsharif-II & ICT-II Tie Bay ALSTOM C264MB1M6910013404000031111N10 C264.5.0.4.0-build 11 P743_50BF
6 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 406 400 Kv ICT-II Main Bay ALSTOM C264MB1M691001340400A031111N10 C264.5.0.4.0-build 11 P643_87T, P141_HV, P141_LV, P643_64T
7 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 407 400 Kv Kahalgaon-II Main Bay ALSTOM C264MB1M69100330200A031111N10 C264.5.0.4.0-build 11 P444_21M1, REL670_21M2, P643_87R,P442_21R, P141_64R
8 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 408 400 Kv Kahalgaon-II & BR-I Tie Bay ALSTOM C264MB1M6910013302000031111N10 C264.5.0.4.0-build 11 P743_50BF
9 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 409 400 Kv BR-I Main Bay ALSTOM C264MB1M6910013404000031111N10 C264.5.0.4.0-build 11 P643_87R, P442_21R, P141_64R
10 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 410 400 Kv Kahalgaon-I Main Bay ALSTOM C264MB1M691003404000031111N10 C264.5.0.4.0-build 11 P444_21M1, REL670_21M2, P643_87R,P442_21R, P141_64R
11 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 411 400 Kv Kahalgaon-I & ICT-III(F) Tie Bay ALSTOM C264MB1M6910013403000031111N10 C264.5.0.4.0-build 11 P743_50BF
13 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 413 400 kv Future Main Bay ALSTOM C264MB1M691001306600A030111N10 C264.5.0.4.0-build 11
14 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 414 400 kv BR-II & Future Tie Bay ALSTOM C264MB1M691001306600A030111N10 C264.5.0.4.0-build 11 P743_50BF
15 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 415 400 kv BR-II Main Bay ALSTOM C264MB1M691001306600A030111N10 C264.5.0.4.0-build 11 P643_87R, P442_21R, P141_64R
16 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 106 132 Kv Bus Transfer Bay ALSTOM C264MB1M691001340500A031111N10 C264.5.0.4.0-build 11 P141_50BF
16 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 107 132 Kv Lakhisarai-I Bay ALSTOM C264MB1M691001330200A031111N10 C264.5.0.4.0-build 11 P442_21, P141_67/67N, P141_50BF
16 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 108 133 Kv Lakhisarai-II Bay ALSTOM C264MB1M6910013303000031111N10 C264.5.0.4.0-build 11 P442_21, P141_67/67N, P141_50BF
16 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 109 132 kv ICT-I Bay ALSTOM C264MB1M691001340500A031111N10 C264.5.0.4.0-build 11 P141_50BF
16 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 110 132 Kv Jamui-I Bay ALSTOM C264MB1M6910013403000031111N10 C264.5.0.4.0-build 11 P442_21, P141_67/67N, P141_50BF
16 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 111 133 Kv Jamui-II Bay ALSTOM C264MB1M691001330200A031111N10 C264.5.0.4.0-build 11 P442_21, P141_67/67N, P141_50BF
16 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base 112 132 kv ICT-II Bay ALSTOM C264MB1M691001340300E031111N10 C264.5.0.4.0-build 11 P141_50BF
16 ER-I Lakhisarai ALSTOM Ds agile-V5.0.4.0-base BB4L BUSBAR PANEL ALSTOM C264SB1M691001300000A031111N10 C264.5.0.4.0-build 11 P741_CUA, P741_CUB
* Implemented SAS architecture to be attached
Data required for SAS upgradation in ER
Sl.No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
1 NEW MELLI M/s GE DS AGILE, 5_12_1_0 Year of commissioning 2015 205 JLHEP Line 1 ALSTOM C264MBIM6910013904000030111N10 C264-5.0.4.1-build08 P444, REL670
2 206 JLHEP Line 2 ALSTOM C264MBIM6910013904000030111N10 C264-5.0.4.1-build08 P444, REL670
3 207 Rangpo Line ALSTOM C264MBIM6910013904000030111N10 C264-5.0.4.1-build08 P444, REL670
4 208 Bus Reactor 1 ALSTOM C264MBIM6910013904000030111N10 C264-5.0.4.1-build08 P642, P442, P441
5 210 Bus Coupler ALSTOM C264MBIM6910013904000030111N10 C264-5.0.4.1-build08
6 211 Bus Reactor 2 ALSTOM C264MBIM6910013904000030111N10 C264-5.0.4.1-build08 P642, P442, P441
7 212 Tashiding Line ALSTOM C264MBIM6910013904000030111N10 C264-5.0.4.1-build08 P444, REL670
8 --- Aux Panel ALSTOM C264MB1M6910013403000031111N10 C264-5.0.4.1-build08
* Implemented SAS architecture to be attached
Data required for SAS upgradation in ER
Sl.No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* BCU MLFB NO :- Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
1 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA0 404 MAIN BAY OF BR-II SIEMENS 6MD663 V04.81.03 87.1R_7UT613, 87.1TEE_7UT613 , 64.2R_7SJ804, 21.2_7SA522
2 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 405 TIE BAY OF B/R-II AND NRNC-RNC LINE-1 SIEMENS 6MD663 V04.81.03 50ZT_7SS525
3 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 406 MAIN BAY OF NRNC-RNC LINE-1 SIEMENS 6MD663 V04.81.03 21.1_7SA522
4 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 BCU-1_6MD66315EB900AA0,BCU-2_6MD63315EB900AA0 407 MAIN BAY OF ICT-II SIEMENS BCU-1_6MD663,BCU-2_6MD633 BCU1 :-V04.81.03 BCU2:-V04.70.00 NO IEDS CONNECTED
5 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 408 TIE BAY OF ICT-II AND NRNC-RNC LINE-2 SIEMENS 6MD663 V04.81.03 50ZT_7SS525
6 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 409 MAIN BAY OF NRNC-RNC LINE-2 SIEMENS 6MD663 V04.81.03 21.1_7SA522
7 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA0 410 MAIN BAY OF B/R-I SIEMENS 6MD663 V04.81.03 21.2_7SA522, 64.2R_7SJ804, 87.1R_7UT613 , 87.1TEE_7UT613
8 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 411 TIE BAY OF B/R-II AND NRNC-RNC LINE-3 SIEMENS 6MD663 V04.81.03 50ZT_7SS525,
9 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 412 MAIN BAY OF NRNC-RNC LINE -3 SIEMENS 6MD663 V04.81.03 21.1_7SA522
10 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 BCU-1_6MD66315EB900AA0, BCU-2_6MD63315EB900AA0 413 MAIN BAY OF ICT-I SIEMENS BCU-1_6MD663,BCU-2_6MD633 V04.81.03 NO IEDS CONNECTED
11 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 414 TIE BAY OF ICT-1 AND NRNC-RNC LINE -4 SIEMENS 6MD663 V04.81.03 50ZT_7SS525
12 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 415 MAIN BAY OF NRNC-RNC LINE-4 SIEMENS 6MD663 V04.81.03 21.1_7SA522
13 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD86-DAAA-AA0-0AAAA0-AF0112-23111B-BCA000-000AC0-CB3BA1-CE0CE0-EA0 416 MAIN BAY OF STATCOM SIEMENS 6MD86 V07.00 50_51_7SJ804 V4.7
14 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD86-DAAA-AA0-0AAAA0-AF0112-23111B-BCA000-000AC0-CB3BA1-CE0CE0-EA0 417 TIE BAY OF STATCOM AND FUTURE SIEMENS 6MD86 V07.00 50Z_7VK610 V4.7
15 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD86-DAAA-AA0-0AAAA0-AF0112-23111B-BCA000-000AC0-CB3BA1-CE0CE0-EA0 418 FUTURE BAY SIEMENS 6MD86 V07.00
16 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 LINE BCU :-6MD86-DAAA-AA0-0AAAA0-AF0112-23111B-BCA000-000AA0-CB3BA1-CD0CE0-EA0CH3 419 MAIN BAY OF NRNC-NPPSP LINE-1 SIEMENS LINE BCU :-6MD86 V07.03 LINE:-21.1_7SA522, L/R-I:- 21.2R_7SA522, 64.2R_7SJ802, 87.1R_7UT612
17 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD86-DAAA-AA0-0AAAA0-AF0112-23111B-BCA000-000AC0-CB3BA1-CE0CG0-CG0 420 TIE BAY OF NRNC-NPPSP LINE-1 AND PATRATU CIRCUIT-1 SIEMENS 6MD86 V07.03 50ZT_7VK610
18 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 421 MAIN BAY OF PATRATU CIRCUIT-1 SIEMENS PACIS C264 B7.33 21M1:- SCHIENIDER P444 & 21 M2 :-REL670
19 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 LINE BCU :-6MD86-DAAA-AA0-0AAAA0-AF0112-23111B-BCA000-000AA0-CB3BA1-CD0CE0-EA0CH3 422 MAIN BAY OF NRNC-NPPSP LINE-2 SIEMENS LINE BCU :-6MD86 V07.03 LINE:- 21.1_7SA522, L/R-II:- 21.2R_7SA522, 64.2R_7SJ802, 87.1R_7UT612
20 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD86-DAAA-AA0-0AAAA0-AF0112-23111B-BCA000-000AC0-CB3BA1-CE0CG0-CG0 423 TIE BAY OF NRNC-NPPSP LINE-2 AND PATRATU CIRCUIT-2 SIEMENS 6MD86 V06.20 50ZT_7VK610
21 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 424 MAIN BAY OF PATRATU CIRCUIT-2 SIEMENS PACIS C264 B7.33 21M1:- SCHIENIDER P444 & 21 M2 :-REL670
22 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 425 FUTURE BAY SIEMENS
23 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 426 TIE BAY OF FUTURE AND CHANDWA LINE-1 SIEMENS 6MD663 V04.82.05 50ZT_7SS525
24 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 427 MAIN BAY OF NRNC-CHANDWA LINE-1 SIEMENS 6MD663 V04.82.05 21.1_7SA522
25 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 428 FUTURE BAY SIEMENS
26 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 429 TIE BAY OF FUTURE AND NRNC-CHANDWA LINE-1 SIEMENS 6MD663 V04.82.05 50ZT_7SS525
27 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 430 MAIN BAY OF NRNC-CHANDWA LINE-2 SIEMENS 6MD663 V04.82.05 21.1_7SA522
29 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 701 FUTURE BAY SIEMENS
30 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 702 TIE BAY OF FUTURE AND ICT-I SIEMENS 6MD663 V04.81.03 50ZT_7SS525
31 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 BCU-1_6MD66315EB920AA0, BCU-2_6MD66315EB920AA0 703 MAIN BAY OF ICT-I SIEMENS BCU-1_6MD663,BCU-2_6MD663 1 BCU-1 :-V04.83.03 BCU-2:- V04.81.03 64T.2B_7SJ804, 67.2HV_7SJ804 V4.6, 87T.1_7UT613 V4.6, 64T.2R_99LV_7UT, 64T.2Y_7SJ804, 64T_2SP_7SJ804 V4.6, 67.1_IV_7SJ804
32 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 LINE BCU:-6MD66315EB900AA1 L/R-I BCU -1 &2:- 6MD66315EB920AA0 704 MAIN BAY OF NRNC-DMG LINE-1 SIEMENS LINE BCU:-6MD663 V4.8 L/R-I :- BCU-1_6MD663, BCU-2_6MD663 V4.8 LINE BCU :- V04.82.05 L/R-I BCU -1 :-V04.82.05, BCU-2:- V04.83.03 LINE :-21.1_7SA522, L/R-I:- 21.2_7SA522, 50ZT_7SS525 V3.3, 64R, 871R
33 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 705 TIE BAY OF NRNC-DMG LINE-1 AND ICT-II SIEMENS 6MD663 V4.8 V04.82.05 50ZT_7SS525 V3.3
34 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 BCU-1_6MD66315EB920AA0, BCU-2_6MD66315EB920AA0 706 MAIN BAY OF ICT-II SIEMENS BCU-1_6MD663V4.8, BCU-2_6MD663 1 BCU-1 :-V04.82.05 , BCU-2:- V04.81.03 64T.2B_7SJ804 V4.6, 67.2HV_7SJ804 V4.6, 87T.1_7UT613 V4.6, 64TR_99LV_7UT613 V4.6 , 64T.2Y_7SJ804, 64T_2SP_7SJ804 V4.6, 67.1_IV_7SJ804 V4.6
34 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 V04.70.00 707 MAIN BAY OF B/R-II SIEMENS BCU-1_6MD663V4.8, BCU-2_6MD633 BCU-1 :-V04.82.05 , BCU-2:- V04.70.00 7SA522, 64R_2R_7SJ804, 64R_2B_7SJ804 V4.6, 64R_2Y_7SJ804, 64R_2SP_7SJ804V4.6, 87_R_1_7UT613 V4.6 , 87_TEE_7UT613 V4.1
35 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA0 708 TIE BAY OF B/R-II AND FUTURE SIEMENS 6MD663 V04.81.03 50ZT_7SS525 V3.3
39 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 709 FUTURE BAY SIEMENS
40 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 BCU-1_6MD66315EB900AA0, BCU-2_6MD63315EB920AA0 710 MAIN BAY OF B/R-I SIEMENS BCU-1_6MD663, BCU-2_6MD633 BCU-1 :-V04.81.03 , BCU-2:- V04.70.00 7SA522, 64R_2R_7SJ804, 64R_2B_7SJ804 V4.6, 64R_2Y_7SJ804, 64_2SP_7SJ804, 87_R_1_7UT613 V4.6 , 87_TEE_7UT613 V4.1
41 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 711 TIE BAY OF B/R-I AND FUTURE SIEMENS 6MD663 V04.81.03 50ZT_7SS525 V3.3
42 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 712 FUTURE BAY SIEMENS
43 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 713 FUTURE BAY SIEMENS
44 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 6MD66315EB900AA1 714 TIE BAY OF FUTURE AND NRNC-DMG LINE-2 SIEMENS 6MD663 V04.83.03 50ZT_7SS525
45 ER1 NEW RANCHI SIEMENS SICAM PAS/V8.03 LINE BCU:-6MD66315EB900AA1 L/R-II BCU -1 &2:- 6MD66315EB920AA0 715 MAIN BAY OF NRNC-DMG LINE-2 SIEMENS LINE BCU:-6MD663 V4.8 L/R-II :- BCU-1_6MD663, BCU-2_6MD663 V4.8 LINE BCU :- V04.82.02 , L/R-II:- BCU-1 _V04.83.03 ,BCU-2_V04.83.03 LINE :-21.1_7SA522, L/R-II:- 21.2_7SA522, 50ZT_7SS525 V3.3, 64R2, 871R
Implemented SAS architecture to be attached
Name of Sub station Pandiabili
Sl No Description Remarks
1 SAS make SIEMENS
4 SAS Operating system Windows version Window XP
5 SAS Server software version Wincc SIMATIC-V 7.2 Sicam PAS-8.04
List of IEDs(Baywise) along with their version no.
Sl No Bay name Bay NO IED Description(distance/diff/etc) MLFB No Firmware version
1 Bus Reactor Main bay 401 7UT613.87R 7UT61316EB921AA0 V 04.65.02
2 Bus Reactor Main bay 401 7SA522.21R 7SA52216AB900EA0 V 04.73.03
3 Bus Reactor Main bay 401 75J802.64R 7SJ80225EB901FA0 V 04.74.05
4 Bus Reactor Main bay 401 6MD86.BCU BM1503001015 V06.00
5 Bus Reactor Tie bay 402 7VK61-50ZT 7VK61016AB924YC0 v 4.71.02
6 Bus Reactor Tie bay 402 6MD86.BCU BM1503000352 V06.00
7 Main bay 400 kv Baripada Line 403 7SA52-21M2 7SA52216EB904QB4 V 04.73.03
8 Main bay 400 kv Baripada Line 403 REL670-21M2 I1507035 1.4_77m_54
9 Main bay 400 kv Baripada Line 403 6MD86.BCU BM1503001006 V06.00
10 Baripada Line Reactor bay 403R 7SA522-21.1R 7SA52216AB900EA0 V 04.73.03
11 Baripada Line Reactor bay 403R 7SJ802-64R 7SJ80225EB901FA0 V 04.74.05
12 Baripada Line Reactor bay 403R 7UT613.87.1R 7UT61316EB921AA0 V 04.65.02
13 Baripada Line Reactor bay 403R 7VK61-50ZT 7VK61016AB924YC0 v 4.71.02
14 Baripada Line Reactor bay 403R 6MD86.BCU BM1503000334 V06.00
15 Main bay 400 kv Duburi Line 404 7SA52-21M2 7SA52216EB904QB4 V 04.73.03
16 Main bay 400 kv Duburi Line 404 REL670-21M2 I1507041 1.4_77m_54
17 Main bay 400 kv Duburi Line 404 6MD86.BCU BM1503001033 V 06.00
18 Duburi Line Reactor Bay 404R 7SA522-21.1R 7SA52216AB900EA0 V 04.73.03
19 Duburi Line Reactor Bay 404R 7SJ802-64R 7SJ80225EB901FA0 V 04.74.05
20 Duburi Line Reactor Bay 404R 7UT613.87.1R 7UT61316EB921AA0 V 04.65.02
21 Duburi Line Reactor Bay 404R 7VK61-50ZT 7VK61016AB924YC0 v 4.71.02
22 Duburi Line Reactor Bay 404R 6MD86.BCU BM1503000322 V 06.00
23 Tie bay Duburi line & ict-1 405 7VK61-50ZT 7VK61016AB924YC0 v 4.71.02
24 Tie bay Duburi line & ict-2 405 6MD86.BCU BM1503000328 V 06.00
25 Main bay ICT-1 406 7UT613-87.1 7UT61316EB921AB0 V 04.65.02
26 Main bay ICT-1 406 7SJ804-67.1 LV 7SJ80415EB901FC0 V 04.74.05
27 Main bay ICT-1 406 7SJ804-67.1 HV 7SJ80415EB901FC0 V 04.74.05
28 Main bay ICT-1 406 7SJ802-64.1 R 7SJ80225EB901FA0 V 04.74.05
29 Main bay ICT-1 406 7RW-99LVT 7RW80205EB901DD0 V 04.62.00
30 tie bay ICT-1 405 6MD86-BCU BM1503001033 V06.00
31 tie bay ICT-2 405 7UT613-87.2 7UT61316EB921AB0 V 04.65.02
32 Main bay ICT-2 407 7SJ804-67.1 LV 7SJ80415EB901FC0 V 04.74.05
33 Main bay ICT-2 407 7SJ804-67.1 HV 7SJ80415EB901FC0 V 04.74.05
34 Main bay ICT-2 407 7SJ802-64.1 R 7SJ80225EB901FA0 V 04.74.05
35 Main bay ICT-2 407 7RW-99LVT 7RW80205EB901DD0 V 04.62.00
36 Main bay ICT-2 407 6MD86-BCU BM1503001024 V06.00
37 Tie bay ICT-2 408 7VK61-50ZT 7VK61016AB924YC0 v 4.71.02
38 Tie bay ICT-2 408 6MD86-BCU BM1503000711 V06.00
39 Mendhasal -2 line Main bay 409 7SA52-21M2 7SA52216EB904QB4 V 04.73.03
40 Mendhasal -2 line Main bay 409 REL670-21M2 I1507039 1.4_77m_54
41 Mendhasal -2 line Main bay 409 6MD86.BCU BM1503501662 V06.00
42 Future ICT BAY 410 6MD86-BCU BM1503000988 V06.00
43 Tie bay Mehdhasal -1 line 411 7VK61-50ZT 7VK61016AB924YC0 v 4.71.02
44 Tie bay Mehdhasal -1 line 411 6MD86-BCU BM1503000340 V06.00
45 Mendhasal-1 line bay 412 7SA52-21M2 7SA52216EB904QB4 V 04.73.03
46 Mendhasal-1 line bay 412 REL670-21M2 I1507038 1.4_77m_54
47 Mendhasal-1 line bay 412 6MD86.BCU BM1503000997 V06.00
48 400 kv BUS BAR BUS BAR PANEL 7SS52-MCU-1 7SS52206AB921CA0 V04.73.04
49 401 kv BUS BAR BUS BAR PANEL 7SS52-MCU-2 7SS52206AB921CA0 V04.73.04
50 220 KV Pratapsasan -1Line bay 201 7SA52-21M1 7SA52216EB904QB4 V 04.73.03
51 221 KV Pratapsasan -1Line bay 201 REL760-21M2 I1507047 1.4_77m_54
52 222 KV Pratapsasan -1Line bay 201 6MD86-BCU BM1503000280 V06.00
54 220 KV Pratapsasan-2 Line bay 203 7SA52-21M1 7SA52216EB904QB4 V 04.73.03
55 221 KV Pratapsasan-2 Line bay 203 REL760-21M2 I1507045 1.4_77m_54
56 222 KV Pratapsasan-2 Line bay 203 6MD86-BCU BM1503000286 V06.00
57 220 KV Samagra -1 line 204 7SA52-21M1 7SA52216EB904QB4 V 04.73.03
58 220 KV Samagra -1 line 204 REL760-21M2 I1507044 V06.00
59 220 KV Samagra -1 line 204 6MD86-BCU BM1503000274 V06.00
60 220 Samagra 2 line 205 7SA52-21M1 7SA52216EB904QB4 V 04.73.03
62 220 Samagra 2 line 205 6MD86-BCU BM1503000298 V06.00
63 Bus coupler 206 6MD86-BCU BM1503000304 V06.00
65 Atri-1 line 209 7SA52-21M1 7SA52216EB904QB4 V 04.73.03
67 Atri-1 line 209 6MD86-BCU BM1503000316 V06.00
68 Atri-2 line 208 7SA52-21M1 7SA52216EB904QB4 V 04.73.03
70 Atri-2 line 208 6MD86-BCU BM1606003145 V06.00
71 220 KV BUS BAR 220 KV BUS BAR 7SS52 -MCU 7SS52206AB921CA0 V04.73.04
Data required for SAS upgradation in ER
Sl.No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
1 RANGPO M/s Schneider PASIS, Version 4.80.3.3 ; Datbase version - 12.6 Year of commissioning 2014 402 400KV KISHANGANJ FUTURE LINE BAY SCHNEIDER C264M11M691001340200A031111N10 B7.36B P444, REL670
2 404 400KV DIKCHU LINE SCHNEIDER C264M11M691001340200A031111N10 B7.36B P444, REL670
3 406 400KV KISHANGANJ FUTURE LINE BAY SCHNEIDER C264M11M691001340200A031111N10 B7.36B P444, REL670
4 408 400KV KISHANGANJ LINE SCHNEIDER C264M11M691001340200A031111N10 B7.36B P444, REL670
5 414 400KV BINAGURI-2 LINE SCHNEIDER C264M11M691001340200A031111N10 B7.36B P444, REL670
6 415 400KV TEESTA-V-1 LINE SCHNEIDER C264M11M691001340200A031111N10 B7.36B P444, REL670
7 416 400KV TEESTA-V-2 LINE SCHNEIDER C264M11M691001340200A031111N10 B7.36B P444, REL670
8 417 400KV BINAGURI-1 LINE SCHNEIDER C264M11M691001340200A031111N10 B7.36B P444, REL670
14 403 400KV 80MVAR BUS REACTOR -II SCHNEIDER C264M11M691001340200A031111N10 B7.36B P643, P141, P442
15 407 400KV 80MVAR BUS REACTOR -I SCHNEIDER C264M11M691001340200A031111N10 B7.36B P643, P141, P442
16 405 400KV BUS COUPLER SCHNEIDER C264M11M691001340200A031111N10 B7.36B
17 201 400/220KV 315MVA ICT-5 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
18 202 400/220KV 315MVA ICT-4 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
19 203 400/220KV 315MVA ICT-3 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
20 204 220KV TASHIDING LINE SCHNEIDER C264M11M691001340200A031111N10 B7.36B P444, REL670
21 205 220KV NEW-MELLI-1 LINE SCHNEIDER C264M11M691001340200A031111N10 B7.36B P444, REL670
22 206 220KV BUS-COUPLER SCHNEIDER C264M11M691001340200A031111N10 B7.36B
23 207 400/220KV 315MVA ICT-2 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
24 208 400/220KV 315MVA ICT-1 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
28 101 132KV MELLI LINE (main-2 as O/C&E/F ) SCHNEIDER C264M11M691001340200A031111N10 B7.36B P442, P141
29 102 132KV CHUZACHEN-2 LINE (main-2 as O/C&E/F ) SCHNEIDER C264M11M691001340200A031111N10 B7.36B P442, P141
30 103 220/132KV 100MVA ICT-1 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
31 104 220/132KV 100MVA ICT-2 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
32 105 132KV RANGIT LINE (main-2 as O/C&E/F ) SCHNEIDER C264M11M691001340200A031111N10 B7.36B P442, P141
33 106 132KV GANGTOK -2 LINE (main-2 as O/C&E/F ) SCHNEIDER C264M11M691001340200A031111N10 B7.36B P442, P141
34 107 132KV BUS-COUPLER-2 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
35 108 220/132KV 100MVA ICT-3 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
36 109 132KV BUS-SECTIONLIZER-1 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
37 110 132KV BUS-SECTIONLIZER-2 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
38 111 132KV GANGOK-2 LINE (main-2 as O/C&E/F ) SCHNEIDER C264M11M691001340200A031111N10 B7.36B P442, P141
39 112 132KV BUS-COULER -1 SCHNEIDER C264M11M691001340200A031111N10 B7.36B
40 113 132KV CHUZACHEN-1 LINE (main-2 as O/C&E/F ) SCHNEIDER C264M11M691001340200A031111N10 B7.36B P442, P141
Data required for SAS upgradation in ER
Sl.No. Name of the Region Name of the substation SAS Details Installed BCU Details
Make Model / Version Remarks (If any)* Bay Number Bay Description BCU make Complete Model Firmware Version Remaks (Other IEDs connected to SAS (for this bay) may be mentioned here)
ER1 PUSAULI ALSTOM DS-AGILE oi-5.11.8.0 B401BCU VARANASI ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1) REL 670_21M2 (2)P442-DR RELAY
B401RBCU VARANASI-NR-LR ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)21 R
B402BCU VNS NORTH -TIE ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0
B404BCU ALLAHABAD ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1) REL 670_21M2 (2)P442-DR RELAY
B404RBCU ALLAHABAD -LR ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)21 R
B405BCU ALLAHABAD TIE ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0
B406BCU ICT3-LV SIDE ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P743_50BF
B407BCU ICT-1 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)B407DGA (2) B407ODS (3) B407FOS
B408BCU ICT-1 TIE ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0
B409BCU DALTONGAN-1 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P444_21M1 (2)P743_50BF (3)REL 670_21M2
B410BCU ICT-2 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0
B411BCU ICT-2 TIE ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0
B412BCU BSF-1 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P442-DR RELAY
B412RBCU BSF-1 -LR ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)21 R (2)REL 670_21M2
B413BCU BUS REACTOR-1 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P141_64R (2)P442_21R (3)P645_87R (4)P743_50BF
B414BCU BUS REACTOR-1 TIE ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0
B415BCU BSF-2 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1) REL 670_21M2 (2)P442-DR RELAY
B415RBCU BSF-2-LR ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)21R
B416BCU BUS REACTOR-2 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P141_64R (2)P442_21R (3)P645_87R (4)P743_50BF
B417BCU BUS REACTOR-2 TIE ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P743_50BF
B418BCU VARANASI EAST ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P444_21M1 (2)P743_50BF
B418RBCU VNS EAST -LR ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P141_64R (2)P442_21R (3)P645_87R (4)P743_50BF
B419BCU NABINAGAR-1 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P444_21M1 (2)P743_50BF (3)REL 670_21M2
B420BCU NABINAGAR-1 TIE ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P743_50BF
B421BCU BSF-4 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P444_21M1 (2)P743_50BF
B421RBCU BSF-4 -LR ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P141_64R (2)P442_21R (3)P645_87R (4)P743_50BF
B422BCU DALTONGAN-2 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P444_21M1 (2)P743_50BF (3)REL 670_21M2
B423BCU DALTONGANJ-2 TIE ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P743_50BF
H709BCU ICT-3 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P141_51N (2)P141_67HV (3)P141_67IV (4)P645_64 (5)P645_87
B424BCU NABINAGAR-2 ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P444_21M1 (2)P743_50BF (3)REL 670_21M2
B707BCU FATEHPUR ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P444_21M1 (2)REL 670_21M2 (3)M871-DR RELAY (4)P645_87T
H703BCU 330 MVAR BUS REACTOR ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P141_64R (2)P442_21R (3)P645_87R (4)P743_50BF
H708BCU ICT-3 TIE ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P743_50BF
H707RBCU FATEHPUR-LR ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P645_87R (2)P743_50BF
H710RBCU GAYA-FTP REACTOR ALSTOM Make-Alstom MicomC264 Software version: c264-5.1.34.0 (1)P141_64R (2)P442_21R (3)P645_87R (4)P743_50BF
RELAY Relay Model
B401S1M2 Make-ABB REL670
B404A1M2 Make-ABB REL670
B40650BF Make-Alstom MicomP743
B407DGA Severon Qualitrol
B40921M1 Make-Alstom MicomP444
B40921M2 Make-ABB REL670
B40950BF Make-Alstom MicomP743
B412B1M2 Make-ABB REL670
B41321R Make-Alstom MicomP442
B41350BF Make-Alstom MicomP743
B41364R Make-Alstom MicomP141
B41387R Make-Alstom MicomP645
B415B2M2 Make-ABB REL670
B41621R Make-Alstom MicomP442
B41650BF Make-Alstom MicomP743
B41664R Make-Alstom MicomP141
B41687R Make-Alstom MicomP645
B41750BF Make-Alstom MicomP743
B41821M1 Make-Alstom MicomP444
B41821M2 Make-ABB REL670
B41850BF Make-Alstom MicomP743
B418R21R Make-Alstom MicomP442
B418R50B Make-Alstom MicomP743
B418R64R Make-Alstom MicomP141
B418R87R Make-Alstom MicomP645
B41921M1 Make-Alstom MicomP444
B41921M2 Make-ABB REL670
B41950BF Make-Alstom MicomP743
B42050BF Make-Alstom MicomP743
B421R50BF Make-Alstom MicomP743
B42121M1 Make-Alstom MicomP444
B42121M2 Make-ABB REL670
B42121R Make-Alstom MicomP442
B42150BF Make-Alstom MicomP743
B421R64R Make-Alstom MicomP141
B421R87R Make-Alstom MicomP645
B401LR21R Make-Alstom MicomP442
B404LR21R Make-Alstom MicomP442
B412LR21R Make-Alstom MicomP442
B415LR21R Make-Alstom MicomP442
RELAY Relay Model
B42221M1 Make-Alstom MicomP444
B42221M2 Make-ABB REL670
B42250BF Make-Alstom MicomP743
B42350BF Make-Alstom MicomP743
B42421M1 Make-Alstom MicomP444
B42421M2 Make-ABB REL670
B42450BF Make-Alstom MicomP743
B70721M2 Make-ABB REL670
BB_87CUA Make-Alstom MicomP741
BB_87CUB Make-Alstom MicomP741
H703_21R Make-Alstom MicomP442
H703_64R Make-Alstom MicomP141
H703_87R Make-Alstom MicomP645
H703_87T Make-Alstom MicomP645
H70721M1 Make-Alstom MicomP444
H707R21R Make-Alstom MicomP442
H707R50B Make-Alstom MicomP743
H707R64R Make-Alstom MicomP141
H707R87R Make-Alstom MicomP645
H707_DR Make-Alstom M871
H70850BF Make-Alstom MicomP743
H70967HV Make-Alstom MicomP141
H70967IV Make-Alstom MicomP141
H709_51N Make-Alstom MicomP141
H709_64 Make-Alstom MicomP645
H709_87 Make-Alstom MicomP645
H710R21R Make-Alstom MicomP442
H710R50B Make-Alstom MicomP743
H710R64R Make-Alstom MicomP141
H710R87R Make-Alstom MicomP645
P643NORTH Convertor Make-Alstom MicomP643
P643EAST Convertor Make-Alstom MicomP643
RTCC_ICT1 Make- a-eberle
RTCC_ICT2 Make- a-eberle
TER_P141 Make-Alstom MicomP141
401-DR Relay Make-Alstom MicomP442
404-DR Relay Make-Alstom MicomP442
412-DR Relay Make-Alstom MicomP442
415-DR Relay Make-Alstom MicomP442
Sr. no. Name Cat REGION SAS/RTU MAKE Target
1 ARA II ER-I DONGFENG_RTU+ALSTOM RTU GW Mar. 15
2 Purnea II ER-I ALSTOM C264 RTU
3 Sasaram 765 I/II/III ER-I GE SAS
4 BANKA III ER-I GE SAS
5 GAYA 765kV III ER-I Siemens SAS
6 Lakhisarai III ER-I GE SAS
7 Ranchi (765 kV) III ER-I Siemens SAS
8 Chaibasa III ER-I Siemens SAS
9 Behrampur III ER-II GE SAS
10 BOLANGIR III ER-II Siemens SAS Apr. 15
11 Angul (765 kV) III ER-II Siemens SAS May 15
12 Jharsugda (765 kV) III ER-II Siemens SAS May 15
13 KEONJHAR III ER-II Siemens SAS
14 Rangpo III ER-II Schneider SAS
15 NEW MELLI III ER-II GE SAS
16 Pandiabilli III ER-II Siemens SAS
17 kishenganj III ER-I Siemens SAS
18 Daltonganj III ER-I GE SAS
19 Chandwa III ER-I ABB SAS
20 Talcher HVDC IV ER-II Siemens SAS
21 BIRPARA I ER-II GE ( Advantech + C264 gateways) & Siemens PAS
22 SILIGURI I ER-II GE ( Advantech + C264 gateways)
10 New ranchi ,
19 Daltonganj ,
20 Chandwa GIS,
21 Talcher HVDC
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
01_First Envelope Attachments and Bid Form_Package-Y.xlsx
xlsx • 1.28 MB
02_Second Envelope Bid Vol-III_Pkg-Y.xls
xls • 5.47 MB
03_Attachment-3 Schedule-3-QR.doc
doc • 0.10 MB
04_Attachment-8_Manufacturer Authorization Form.doc
doc • 0.04 MB
05_Attachment 20_KMP Declaration.doc
doc • 0.03 MB
06_Attachment-21_Affidavit for self-certifictaion.DOCX
docx • 0.02 MB
07_Attachment 22_Certificate by Auditor.docx
docx • 0.02 MB
08_Attachment-23-Authorization Certificate issued by Domestic Manufacturer.docx
docx • 0.02 MB
09_Attachment-24-Affidavit for Self Certifictaion-Iron & Steel.docx
docx • 0.02 MB
10_Attachment-25_E-RA Compliance.docx
docx • 0.02 MB
11_Attachment-26_Declaration regarding events encountered pursuant to ITB Clause 2-1.docx
docx • 0.03 MB
12_Legends for Units.pdf
pdf • 0.03 MB
SAS_Lakhisarai.pdf
pdf • 0.27 MB
SAS_NewMelli.pdf
pdf • 0.19 MB
SAS_NewRanchi.pdf
pdf • 0.19 MB
SAS_Pandiabili.pdf
pdf • 0.13 MB
SAS_Purnea.pdf
pdf • 0.44 MB
SAS_Sasaram.pdf
pdf • 0.18 MB
SLD_Ara.pdf
pdf • 0.22 MB
SLD_Birpara.pdf
pdf • 1.01 MB
SLD_Purnea.pdf
pdf • 0.44 MB
SLD_Siliguri.pdf
pdf • 0.67 MB
SLD_TalcherHVDC.pdf
pdf • 0.83 MB
SAS Architect-Chaibasa_sheet2.pdf
pdf • 5.05 MB
SAS_Angul.pdf
pdf • 0.49 MB
SAS_Banka.pdf
pdf • 0.22 MB
SAS_Bolangir.pdf
pdf • 0.19 MB
SAS_Chandwa.pdf
pdf • 0.17 MB
SAS_Daltonganj.pdf
pdf • 0.91 MB
SAS_Gaya.pdf
pdf • 0.01 MB
SAS_Jharsuguda.pdf
pdf • 1.80 MB
SAS_Keonjhar.pdf
pdf • 0.50 MB
SAS_Kishenganj.pdf
pdf • 0.18 MB
Architecture_NTAMC.pdf
pdf • 0.42 MB
SAS - ARCHITECTURE_Rangpo.pdf
pdf • 1.34 MB
SAS Architect-Chaibasa_sheet1.pdf
pdf • 5.86 MB
Section-GTR, Revision-14_TS of RTV coating_Annexure H_Rev 1.pdf
pdf • 0.14 MB
Section-Power & Control Cable-Revision-06.pdf
pdf • 0.26 MB
Section-Sub-station Automation-Revision-04.pdf
pdf • 0.98 MB
Section-Switchyard Erection-Rev-10.pdf
pdf • 5.99 MB
Annexure-I_List of Tender Drawings.pdf
pdf • 0.35 MB
Annexure-II_Description of Items of BPS Given in short form.pdf
pdf • 0.38 MB
Annexure-III_List of Installed SAS_BCU Details.pdf
pdf • 0.34 MB
BCU_Detail_Angul.xlsx
xlsx • 0.02 MB
BCU_Detail_Banka.xlsx
xlsx • 0.01 MB
BCU_Detail_Behrampore.xlsx
xlsx • 0.01 MB
BCU_Detail_Bolangir.xlsx
xlsx • 0.01 MB
BCU_Detail_Chaibasa.xlsx
xlsx • 0.01 MB
BCU_Detail_Chandwa.xlsx
xlsx • 0.01 MB
BCU_Detail_Daltonganj.xlsx
xlsx • 0.01 MB
BCU_Detail_Gaya.xlsx
xlsx • 0.01 MB
BCU_Detail_Jharsuguda.xlsx
xlsx • 0.03 MB
BCU_Detail_Keonjhar.xls
xls • 0.04 MB
BCU_Detail_Kishenganj.xlsx
xlsx • 0.01 MB
BCU_Detail_Lakhisarai.xlsx
xlsx • 0.01 MB
BCU_Detail_New Melli.xlsx
xlsx • 0.01 MB
BCU_Detail_New Ranchi.xlsx
xlsx • 0.02 MB
BCU_Detail_Pandiabili.xlsx
xlsx • 0.01 MB
BCU_Detail_Rangpo.xlsx
xlsx • 0.01 MB
BCU_Detail_Sasaram.xlsx
xlsx • 0.01 MB
SAS_Detail_All.xlsx
xlsx • 0.01 MB
Annexure-IV_Standardised Specific Requirements.pdf
pdf • 1.74 MB
Annexure-V_General Technical Requirement of RTU.pdf
pdf • 0.10 MB
Appendix-II for SAS_Rev04_STANDARD FACTORY SIMULATION TEST PLAN.pdf
pdf • 0.54 MB
GTR-9.5_List of TTR not required.pdf
pdf • 1.80 MB
RTU Technical Specification_Rev02 .pdf
pdf • 0.68 MB
Section-CRP, Revision-09.pdf
pdf • 0.37 MB
Section-GTR, Revision-14.pdf
pdf • 1.19 MB
Section_Project_Rev.00.pdf
pdf • 0.23 MB
~WRL3764.tmp
tmp • 0.48 MB
00-Cover.doc
doc • 2.56 MB
01- IFB.doc
doc • 0.08 MB
02-Section - II ITB SSTE S&I Rev 5-DCB-Mjn.pdf
pdf • 1.95 MB
03-Section - III_BDS .docx
docx • 0.07 MB
04-Annexure-A (BDS).docx
docx • 0.02 MB
04-Annexure-B to BDS.docx
docx • 0.02 MB
04-Annexure-C to BDS.docx
docx • 0.03 MB
05-Section - IV GCC -S&I Rev 3-DCB.pdf
pdf • 1.93 MB
06-Section - V_SCC.doc
doc • 0.12 MB
07-Appendix -I to SCC.doc
doc • 0.16 MB
08-Annexure-I to Section-V (SCC).docx
docx • 0.02 MB
09-Sample Forms and Procedures.doc
doc • 0.48 MB
Amendment No-09.doc
doc • 0.05 MB
Attachment-27- Certification by the Bidder per DoE Order in line with ITB Clause 2-1-Rev1.docx
docx • 0.02 MB
OBD_EXTN_LETTER.doc
doc • 0.29 MB
02_Clarification No-02.docx
docx • 0.08 MB
Second Envelope Bid Vol-III_Pkg-Y_Rev2.xls
xls • 5.47 MB
OBD_EXTN_LETTER.doc
doc • 0.28 MB
01_Amendment No-06.docx
docx • 0.04 MB
OBD_EXTN_LETTER.doc
doc • 0.29 MB
Annexure-XX.pdf
pdf • 0.02 MB
Attachment-27- Certification by the Bidder per DoE Order in line with ITB Clause 2-1.docx
docx • 0.02 MB
Siliguri SS IED details.xlsx
xlsx • 0.01 MB
OBD_EXTN_LETTER.doc
doc • 0.29 MB
OBD_EXTN_LETTER.doc
doc • 0.28 MB
Amendment No-02.doc
doc • 0.05 MB
Amendment No-01.doc
doc • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .