Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 CrAccepted-AOC | ₹18.5 Cr | L1 | Accepted-AOC being lowest |
| 2 | L2₹20.2 CrRejected-Finance 3 KHATAU APARTMENT TILAK ROAD JOSHI LANE GHATKOPAR EAST MUMBAI 400 077 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | ₹20.2 Cr | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹20.7 CrRejected-Finance | ₹20.7 Cr | L3 | Rejected-Finance Being not lowest |
| 4 | L4₹20.8 CrRejected-Finance | ₹20.8 Cr | L4 | Rejected-Finance Being not lowest |
| 5 | L5₹21.3 CrRejected-Finance | ₹21.3 Cr | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | GEMINI PROMOTERS AND BUILDERS PVT. LTD. L5 | Varindera Constructions Limited L7 | Hem Construction Company L2 | MC Gandhi and Sons L4 | SOOD ASSOCIATES PVT LTD L6 | MUKUL BUILDERS LLP L1 | Som Projects Pvt. Ltd. L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| .10NOTE: Schedule ‘A’ Part I to XIV under Ser No. 1.00 to 14.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. | ||||||||||
| 1.00 | Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A' Part I. | 1 | Lumpsum | 16,88,50,000 ₹16.9 Cr | 17,18,80,000 ₹17.2 Cr | 16,29,60,470 ₹16.3 Cr | 15,68,00,000 ₹15.7 Cr | 17,38,83,661.9 ₹17.4 Cr | 14,63,93,087.1 ₹14.6 Cr | 16,69,00,000 ₹16.7 Cr |
| 2.00 | Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch 'A' Part II | 1 | Lumpsum | 38,69,541.59 ₹38.7 L | 36,93,653.33 ₹36.9 L | 19,34,770.79 ₹19.3 L | 39,95,477.58 ₹40.0 L | 18,64,415.49 ₹18.6 L | 29,90,100.32 ₹29.9 L | 35,17,765.08 ₹35.2 L |
| 3.00 | Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A' Part III | 1 | Lumpsum | 52,95,246.25 ₹53.0 L | 48,53,975.73 ₹48.5 L | 44,12,705.21 ₹44.1 L | 50,74,610.99 ₹50.7 L | 41,03,815.85 ₹41.0 L | 44,12,705.21 ₹44.1 L | 44,12,705.21 ₹44.1 L |
| 4.00 | Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A' Part IV | 1 | Lumpsum | 8,88,756.34 ₹8.9 L | 8,14,693.31 ₹8.1 L | 7,40,630.28 ₹7.4 L | 8,41,207.87 ₹8.4 L | 9,40,600.46 ₹9.4 L | 8,08,095 ₹8.1 L | 8,00,000 ₹8 L |
| 5.00 | Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A' Part V | 1 | Lumpsum | 5,35,489.86 ₹5.4 L | 4,90,865.71 ₹4.9 L | 4,46,241.55 ₹4.5 L | 5,06,841.15 ₹5.1 L | 5,66,726.77 ₹5.7 L | 4,06,050 ₹4.1 L | 4,46,241.55 ₹4.5 L |
| 6.00 | Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A' Part VI | 1 | Lumpsum | 14,90,011.68 ₹14.9 L | 13,65,844.04 ₹13.7 L | 12,41,676.4 ₹12.4 L | 14,10,296.06 ₹14.1 L | 13,28,593.75 ₹13.3 L | 11,11,246 ₹11.1 L | 12,41,676.4 ₹12.4 L |
| 7.00 | Lump sum price worked out for ROAD/ PATH as listed in Sch 'A' Part VII | 1 | Lumpsum | 14,38,421.12 ₹14.4 L | 13,18,552.7 ₹13.2 L | 13,06,565.85 ₹13.1 L | 13,61,465.59 ₹13.6 L | 11,98,684.27 ₹12.0 L | 13,51,215 ₹13.5 L | 11,98,684.27 ₹12.0 L |
| 8.00 | Lump sum price worked out for RETURNING WALL as listed in Sch 'A' Part VIII | 1 | Lumpsum | 83,98,711.09 ₹84.0 L | 83,98,711.09 ₹84.0 L | 55,73,690 ₹55.7 L | 86,88,848.38 ₹86.9 L | 86,86,557.82 ₹86.9 L | 72,00,000 ₹72 L | 76,35,191.9 ₹76.4 L |
| 9.00 | Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A' Part IX | 1 | Lumpsum | 8,57,496.67 ₹8.6 L | 7,86,038.62 ₹7.9 L | 11,00,454 ₹11.0 L | 8,11,620.6 ₹8.1 L | 9,07,517.31 ₹9.1 L | 10,00,395 ₹10.0 L | 7,14,580.56 ₹7.1 L |
Tender Value
₹18.8 Cr
EMD Value
₹12.7 L
Closing Date
24 Oct 2025, 6:00 pmClosed
CE (AF) GANDHINAGAR
HQ CE (AF) GANDHINAGAR Lekawada Patia, Chiloda, Gandhinagar-382042
PROVN OF DEFICIENT MD ACCN FOR AIRMEN OF AF STN KANHERI HILLS (PHASE-I)
2025_MES_717169_2
84201
Open Tender
Civil Works
548 days
GE (AF) Thane
As per Tender documents and NIT
7 documents required · 7 mandatory
₹3,000
GE (AF) Thane
₹12.7 L
Yes
10 Jan 2026
3 Oct 2025
27 Oct 2025
3 Oct 2025
24 Oct 2025
17 Oct 2025
4 Oct 2025 - 11 Oct 2025
Amount
NOTE: Schedule ‘A’ Part I to XIV under Ser No. 1.00 to 14.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only.
Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A' Part I.
Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch 'A' Part II
Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A' Part III
Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A' Part IV
Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A' Part V
Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A' Part VI
Lump sum price worked out for ROAD/ PATH as listed in Sch 'A' Part VII
Lump sum price worked out for RETURNING WALL as listed in Sch 'A' Part VIII
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A' Part IX
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A' Part X
Lump sum price worked out for LIFT as listed in Sch 'A' Part XI
Lump sum price worked out for FIRE FIGHTING SYSTEM as listed in Sch 'A' Part XII
Lump sum price worked out for HOT WATER SUPPLY as listed in Sch 'A' Part XIII
Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch 'A' Part XIV
SCHEDULE 'A' PART - XV MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6.
SITE CLERANCE & DEVELOPMENT
M &L for Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out top layer arqanie soil without disturbing or destroy its texture and remove the same to a location specified and stored properly for relaying after the completion of building work exc 1.50 Km but n exc 5 Km complete all as specified and as directed
Relaying the soil excavated in Item no 15 to building site for landscaping and gardening complete all as specified and directed
S&F Step-on pedal garbage dust bin plastic body for indoor use in color of 50 litre capacity Red/Blue/Green. Note :-Labelling on dustbin are as follows: a) Green color waste bin :- Bio degradable waste b) Blue color waste bin :- Reusable/ Recycle waste c) Red color waste bin :- Land Fill waste
INTERNAL ELECTRIFICATION
Supply & Fixing energy efficient exhaust fan of 225mm sweep made of metal body Ventil Air-DS type complete with louver with bolts nuts and washers size of the bolt 15cm long 12mm dia embedded in the wall incl provn of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing wall for the fan base complete all as specified and directed
S & F LED light 10 Watt complete all as specified and directed.
S & F Bulk head light 9 Watt complete all as specified and directed.
Supply, installation, testing and comminsioning of perforated GI sheet cable tray of size 900mm x 62.5mm x 2.0 mm with necessary angle iron suspension supports, anchor fasteners etc complete max height of suspension shall not exceed 500mm size of tray shall be suitable for laying the above mentioned cables complete all as specified and directed.
Supply and fix MCB distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof DB, SPN 6 way , 240 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed.
Supply and fix MCB distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof DB, Vertical Triple pole and netural 8 way , 240 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed.
Supply and Installation of Smart Single Phase Meter with electronic mode of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications: (a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED for Phase presence & LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box. Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on display The meter should support open communication protocol DLMS with the software Note :- (a) It should run the meter in both prepaid and postpaid mode (b) The meters should carry 5 year warranty. (c) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval (d) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters
Supply and Installation of Smart Three Phase Meter with electronic mode of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications: AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 3x240 V, 50 Hz, 10A-100A, with 1600 impulses per KWh & KVArh,LED for Relay status, conforming to IS-16444 standard with inbuilt Cellular or inbuilt 865-867 MHz 6LowPAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on display The meter should support open communication protocol DLMS with the software Note :- (a) It should run the meter in both prepaid and postpaid mode (b) The meters should carry 5 year warranty. (c) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval (d) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters
Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable size factory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of fourty four (44) Nos single phase smart meterand one (01)Nos three phase smart meter with its accessories, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces for 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable, earthing teminals , danger plate, suitable PCC platform complete all as directed
INTERNAL WATER SUPPLY
S & F two way bib cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make : Hindware Cat part No F280054GRCP or equivalent in Cera/Jaquar /Kohler
S & F Overhead Shower (flow rate 6Liter per minute) Single function Square overhead shower 150x150 mm Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System 16 mm dia. complete all as specified and directed Make - Cera Cat Part No F7020103AB, or equivalent in Hindware/Jaquar /Kohler
S & F Wall Mixer 3 In 1 (flow rate 6 liter per minute) with flange Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flanges complete all as specified and directed. Make -Hindware Cat part No F280016GCP or equivalent in Jaquar /Kohler /Cera
S & F Gun-metal, globe or gate valves, of 65 mm Dia bore of pipe with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
S & F of corner glass shelf 12 inch x 12 inch of 8mm thick glass fixed with stainless steel screws on wall complete all as specified and directed.
ROAD/ PATH
M & L for bituminous macadam 50 mm thickness consolidated/ compacted thickness using hot mix plant and mechanical paver with 4% binder (paving bitumen VG-30 grade) content by weight of total mix and 8% of waste plastic by weight of bitumen, rolled and compacted using 8 to 10 tonnes power roller to required camber and gradient complete all as specified and as directed. Note :- (a) The waste plastic should not be PVC sheets or flux sheets, the shredded plastic of size 2-3 mm particle size. (b) Design mix should prepared as per IRC:SP:98-2013.
M&L for providing 30mm thick (consolidated thickness) Semi Dense Asphaltic Concrete (SDAC) with 5.50% paving bitumen (VG-30) binder content by weigh to total mix and 8% of waste plastic by weight of bitumen with mechanical paver using, mixed in hot mix plant, rolled and compacted and well rolled and consolidated with 8 to 12 tonne power roller to reqd gradient and camber complete all as specified and directed. Note :- (a) The waste plastic should not be PVC sheets or flux sheets, the shredded plastic of size 2-3 mm particle size. (b) Design mix should prepared as per IRC:SP:98-2013 guideline
S&F Cobble Stone 100mm x 100mm x 40mm thick with grey cement and pigment, set, jointed and pointed in neat cement slurry in floors over 25mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and directed.
Material and labour for providing and painting 2.5 mm thick road marking strip (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surace including all cost of material, labour, T&P, cleaning of road surface of dirt, seals, ils, grease and foreign material etc. complete all as specified and directed.
Supply and fix ABS dual directional UV protection reflective panels/ road studs/ cat eyes made of plastic body of size 90x110x17mm fixed to the surface with epoxy adhesive as per manufacturer's instruction of specified make or equivalent, Amber, Red or white in colour complete all as specified and directed. Make - 3M 290 series or equivalent as approved by GE.
Supply and fix high intensity prismatic dual directional powder coated delineator having 100mm dia HIP sheet reflector (red/yellow/white) held in strong ABS body mounted over CRC steel tube 47mm dia of 16 gauge sheet support of total height 600mm having flared/welded foot for firm grip to base, HIP reflector and ABS body shall be protected in a welded mesh cage, all steel parts shall be stove enamelled and powder coated and delineator need to be fixed to ground in 200 x 200 x 200 mm concrete block below ground complete all as specified and directed.
EXTERNAL ELECTRIFICATION
Supply ,Installation, testing and commissioning of copper wounded transformer step up/ step down, outdoor type capacity 250 KVA , 22 KV,3 phase , ISS: 1180(2014) Part-I & Latest , E.E. Level -III , Amendment No 4 , 50 C/S oil immersed , Natuarally cooled ,out door type step down Transformer having a No load Voltage Ratio 22000/433V , Vector group Dyn 11 with plus minus 2.5 plus minus 5% off Circuit Tapping as under taken out on the HT side and connected to 22 KV off circuit Tapping switch , HT winding connected in Delta & LT winding connected in Star and the Neutral brought out & connected to a Separate terminal for earthing with outdoor open porcelain bushing on HV side & cable box on LV side with the temperature rise not excceding 40 degree centrigrade by thermometer in oil and 45 degree centrigrade by resistance & Ambient temp 40 degree centrigrade with first filling of Oil with following (i) fitting and accessories:- (a) First fill of Transformer oil (b) 22 KV off circuit tapping switch (c) Oil conservator tank with drain plug and filling cap.(d) Silica gel dehydrating breather charged with silica gel. (e) Oil level gauge.(f) Oil filter valve.(g) Oil drain valve .(h) Thermometer pocket with thermometer (OTI) .(j) Diagram and rating plate.(k) Two earthing arrangements. (l) lifting lugs. (m) four Bidirectional plain roller.(n) Air vent plug (o) Explosion vent. (p) Barebushing on HV side. (q) Cable box on LV side (r) cooling radiators.(s) C .I rollers. (t) Additional neutral terminal brought out side the LV cable box earthing (ii) Extra fittings :-(a) Oil temp Indicator (OTI) (b) Inspection cover.(iii) Inspection :-Transformer factory inspection carried out by department .and test certificate will be furnished for all routine test including oil test.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) earthed ,with stranded aluminium conductor, 22000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed.
Supply and fix cable jointing kit for 22 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sq mm complete all as specified and directed.
Supply, installation, Testing and commissioning of Outdoor type (IP 54), 05 way RMU (Ring Main Unit) 22/24 KV, 630 Amps, 21kA-3 Sec, IP54 SF6 insulated, One side Extensible, consisting of Two No (02) motorised vacuum circuit breaker (Incomer) and Three Nos (03) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVV+M), inside robotically welded stainless steel 304 (Non Ferrite non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 125 kVp internally to manager voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The complete RMU must be type tested for Internal arc 21KA for 1 sec with AFLR Classification for Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must RMU manufacturer's own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protectioncomplete all as specified and as directed. The unit shall include the following with all necessary standard fitting as required at site.- Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE (Channel partner/ System Integrator/ Authourized Partner/ License partner make RMU shall not be accepted.)
(a) Vacuum Circuit Breaker consist of following accessories :- (i) Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, one front RJ 45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display (ii) Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder. (iii) SF6 Gas pressure indicator on the gas tank. (iv) Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation. (v) CT shall be minimum 50-100/1A ,2.5VA , 5P10 - 3 Nos. for protection (vi) 2 x12 Volts, 26 AH Battary with Charger - 1 Set (vii) Bus VT shall be 22KV/V3/110V/V3 ,20VA , Class 0.5 - 3 Nos. for metering (viii) Auxiliary VT shall be 22KV/230 ,500VA for AC supply input to Battary Charger. (ix) Capacitive voltage indication fixed type system as per IE (x) Interlocked Cable box for front termination of the cable suitable upto 3 core 240 Sqmm, 22 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition.
(xi) Touch proof termination kit - As required (xii) Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB. (xiii) Necessay interclocking arrangement for safety and operations (xiv) One No. Operationg Handle for Manual Operation and one no. manometer (xv) Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions. (xvi) Above switchgear shall confirm to all relevant IEC/IS Standards.
M&L for platform for transformer of size 3000mm x 2000mm x 1200mm with brick masonry construction in cement mortar 1:4, PCC (1:4:8) type D-2, 150mm thick as in foundation, PCC (1:2:4) type B-1, 40mm thick as in floor over sub base PCC (1:4:8) type D-2, 75mm thick, brick masonry step on one side to made access to the top of platform including excavation & earth work in any type of soil including 15mm plastering to brick masonry in CM 1:4 and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and two coats of white wash on plastered surface complete all as specified and directed.
Supply only Rubber mat of 2 meter x 1 meter x 19 mm thick 22KV grade ISI Marked per approved make complete all as per specified and as directed
Supply only Rubber mat of 2 meter x 1 meter x 10 mm thick 11KV grade ISI Marked per approved make complete all as per specified and as directed
Material and Labour for Road cutting for crossing cable in any kind of soil/rock strata complete all as per specified and as directed
Material and Labour for Junction box with fuse provision and suitable connection for three phase incomming cable 3 phase out going cable and single phase connection for light fitting with controlled MCB SP-6 Amps -01 Nos enclosed in thermo plastic in closed shock proof safe complete all as per specified and as directed
S & F Copper conductor cable 3 core of size 1.5 Sqmm complete all as per specified and as directed
EXTERNAL WATER SUPPLY
Supplying, installation, commissioning and testing of centrifugal pump set BEE 5 Star rating, electic motor driven, not less than 7.43 LPS at 65 metre head in load, suitable for pumping raw water, complete all as specified and directed and comprising of the following specifications:- (i) Pump, centrifugal, horizontal, split type not less then 7.43 LPS discharge, at 65 metre head, 1440 RPM having bronze impeller and stainless steel shaft single stage directly coupled with electric motor through flexible copling (ii) Squirrel cage indication motor, TEFC, 3 phase 415 + 10 volts, 50 C/S AC supply 1440 RPM, not less then 10 HP directly coupled to centrifugal pump (iii) Common base foundation of ISMC - 100 suitable for installation of above pump set duly drilled holes and painted with two coats of synthetic enamel paint over a coat of red oxide primer (iv) Above ISMC foundation shall be grouted in PCC 1:3:6 type C-2 using 40mm graded aggregate, 30 cm above GL and 15 cm below GL and as per size of common base foundation/ standard Engg practice or as directed by Engineer-in-Charge. (v) Boudrons type pressure gauge 3" dia dial type Make :- Kirloskar Brothers Ltd / Beacon / KSB / Jyoti Note:- Sluice valve and reflux valve, DI pipe and fittings etc. required for suction and delivery and common header etc. shall be measured and paid separately in respective items.
Supply and fix gun-metal, globe or gate valves (ISI marked) conforming to IS 9338, 80 mm dia bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Material and labour for construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 50mmx50mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed. Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC (v) Three coats of white wash to internal surfaces of valve pit shall be provided (vi) Depth of valve pit shall be reckoned from the top of PCC in foundation
Material and labour for construction of brick masonry valve pit of internal size 45cm x 45cm x 45cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed. Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC (v) Three coats of white wash to internal surfaces of valve pit shall be provided (vi) Depth of valve pit shall be reckoned from the top of PCC in foundation
S&F Copper conductor cable 3 core of size 6 Sqmm complete all as specified and directed. Make: Havells/Polycab/Finolex
S&F Cast Iron foot valve for 80 mm bore pipe, lift flanged type as per IS-4038 complete all as specified and directed
Suppy, installation, testing, commissioning, putting into operation and final testing of automatic lift of 8 passengers capacity (544 kg) complete in the shaft well and pit constructed including automatic rescue device (ARD), all standard equipments, accessories and control equipments as per manufacturer design, conforming to NBC/ local by laws and fulfilling the following requirements complete all as specified and directed:
(xix) Car floor: Anti skid PVC flooring on heavy duty MS (Mild steel) platform (xx) Car ceiling and lighting: S.S (Stainless steel) finish with aesthetic appearance with LED ceiling lights (xxi) Car Ventilation: Pressure fan/ blower fan (Car fan with automatic sleep timer shall be provided) (xxii) Emergency lighting in car: Battery operated emergency lighting in the lift car (xxiii) Intercom system: Battery operated Intercom system in lift car,machine room and ground floor/ control room (xiv) Emergency alarm: Battery operated alarm bell system in lift car and control room/ ground floor (xv) All car panel buttons and all floor switches must be with brail language as per lift act. (xvi) Audio visual indication in the lift car showing overloading shall be provided such that doors are kept open till excess load removed. (xvii) Spring buffer/hydraulic buffers shall be provided. (xviii) Mechanical over speed governor, door key holes in the floor doors shall be provided. (xix) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc. (xx) In the hoist way fascia plate shall be provided. (xxi) Permanent writing in the lift machine room and lift well with proper no. of light point, with fixtures, exhaust fan, plug point and 3 phase 440V power supply shall be made available by the department in the lift shaft, machine room or at desired level (xxii) Car top safety barricade shall be provided
(xxiii) ARD (Automatic Rescue Device): Solid state inbuilt automatic rescue device (ARD) for automatic rescue of passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure capable to move the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on main failure
All as per item No. 59 above but lift of 13 passengers capacity (884 kg), (used as firemen lift to be effective in the firefightening operation)
Note for item No. 59 & 60:- Lift of 8 passenger capacity is to be used as passenger lift and Lift of 13 passenger capacity is to be used as as firemen lift to be effective in fire fighting operation. The firemen lift shall have the following requirements. (i) The firemen's lift may be used by the occupants in normal times. (ii) The firemen's lift shall be provided with a firemen switch. The switch shall be a two position (ON/OFF) switch fixed at the evacuation floor (Normally main entrance floor) for enabling the lift to be put into firemen's mode. The switch shall be situated in a glass fronted box with suitable level and fixed adjacent to the lift at the entrance level. When the switch is on, landing call points shall become inoperative and the lift shall be on car control only or on a priority control device. When the switch is off, the lift will return to normal working. (iii) The firemen's lift shall be provided with an audio and visual signal in car. (iv) The firemen's lift shall have a max floor area . It shall have loading capacity of not less than 884kg (13 person lift). (v) The firemen's lift shall be provided with power operated (automatic) doors of minimum 0.8 mtr width. (vi) The speed of firemen's lift shall be 1 m/s or more such that it can reach the top floor from main floor/ firefighter access level within 1 minute incase of building zoned, the firemen's lift shall operate from the lowest served landing to the top most served landing in 1 min. (vii)The words "Firemen lift" shall be conspicuously displayed in fluorecent paint on the lift landing (viii) All other operation requirements of firemen's lift
FIRE FIGHTING SYSTEM
Supply, installation, testing and comminsioning of Common Control Panel suitable for 2 Nos of Electric Motor Driven Hydrant & Sprinkler pump and 01 Nos of Jockey pump with VF drive and soft start will all Protection like over load, under load, dry run etc complete all as specified and directed.
Supply, installation, testing and comminsioning of Auto control Panel for Diesel Engine Driven by Fire Pump, complete all as specified and directed.
Supply, installation, testing and comminsioning of FRLS, PVC outer sheathed , steel armored, aluminium conductor, 1100V grade power cable and glands etc the cable shall be laid in tray/in conduits, on walls, floor or ceiling etc as required. The rate shall excludes tray and conduits. The minimum size of cable shall be 2 core 1.5 Sqmm complete all as specified and directed.
Supply, installation, testing and comminsioning of FRLS, PVC outer sheathed , steel armored, aluminium conductor, 1100V grade power cable and glands etc the cable shall be laid in tray/in conduits, on walls, floor or ceiling etc as required. The rate shall excludes tray and conduits. The minimum size of cable shall be 12 core 1.5 Sqmm complete all as specified and directed.
Supply, installation, testing and comminsioning of perforated GI sheet cable tray of size 300mm x50 mm with necessary angle iron suspension supports, anchor fasteners etc complete max height of suspension shall not exceed 500mm size of tray shall be suitable for laying the above mentioned cables complete all as specified and directed.
Supply, installation, testing and comminsioning of perforated GI sheet cable tray of size 150mm x 50 mm with necessary angle iron suspension supports, anchor fasteners etc complete max height of suspension shall not exceed 500mm size of tray shall be suitable for laying the above mentioned cables complete all as specified and directed.
Supply, installation, testing and comminsioning of GI earthing strips of 50mmx6mm thick, strip shall be un on floor/ceiling/walls from the equipment to the nearest earth pit shall be executed complete all as specified and directed.
Supply, installation, testing and comminsioning of Diesel pump exhaust pipe with super ceramic fiber rope complete all as specified and directed.
Supply, fixing, testing & commissioning of butterfly valve (Wafer Type) conforming to IS 13095 class PN 1.6 having SG iron boy and Stainless steel 304 disc, PTFE bush, Nitrile rubber O ring and Carbon steel flow control lever etc all complete as per standard specification and as directed
150mm dia
100mm dia
80mm dia
65mm dia
Supply, fixing, testing & commissioning of Cast iron Flange ended Foot Valve confirming to IS 4038 having door face seating made out of natural rubber reinforced with special cotton canvas and installing strainer at inlet side etc complete as per standard specification and as directed
150mm dia
100mm dia
Supply, fixing, testing & commissioning of 25mm dia Forged Brass Air release Valve confirming to IS 554, with Polypropylene float, forged brass seat and chambr, stainless steel spring, nitrille ring etc complete as per standard specification and as directed
Supply, fixing, testing & commissioning of Anti corrosive treatment for under ground lines with two coats of primer and one coat of 4mm thick readymade Anticorrosive tape complete as per standard specification and as directed
Supply, fixing, testing & commissioning of Stainless steel headed ISI marked oblique pattern hydrant landing valves as per IS 5290 with 80mm dia flanged inlet & 63 dia female outlet complete with gun metal cap complete all as specified and as directed
Supply and fix 5 kg capacity MULTI PURPOSE (ABC) type fire extinguisher conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex
Supply and fix 5 kg capacity DRY CHEMICAL POWDER type fire extinguisher conforming to IS 2171, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex
Supply and fix 4.5 kg capacity CO2 (Carbon-di-oxide) type fire extinguisher conforming to IS 2171, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex
Supply, installation, testing and comminsioning of 25mm dia Inspection and Testing assembly for sprinkler drain system with thread ended forged bronze valve and sight glass valve with union and necessary fitting complete all as specified and directed.
Supply & fixing AUTOGLOW signage in Block/Word/letters of standard sizes in following sentence as given below :
FIRE LIFT (Size 4" x 12")
EMERGENCY EXIT (Size 4" x 12")
FIRE HYDRANT (Size 4" x 12")
FIRE HOSE REEL (Size 4" x 12")
"DCP" EXTINGUISHER (Size 8" x 12")
"CO2" EXTINGUISHER (Size 8" x 12")
IN CASE OF FIRE, DO NOT USE LIFT, USE STAIRCASE (8" X 8")
FLOW ARROW DIRECTIONS SIGN (8" X 12")
FIRE PUMPS NAME & DETAILS OF FLOW CHART
OTHER SIGN BOARD AS PER FIRE NORMS
Supply, installation, testing and comminsioning of WALL MOUNTED ALARM PANEL with all necessary fitting complete all as specified and directed.
Supply, installation, testing and comminsioning of WALL MOUNTED MS SHEET BOX WITH SPEAKER HOOTER SYSTEM with all necessary fitting complete all as specified and directed.
Supply, installation, testing and comminsioning of MANUAL CALL POINT WITH HAMMER CHAIN with all necessary fitting complete all as specified and directed.
Material and labour for wiring with two runs of 1.5 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduits heavy duty grade ISI marked 20 mm dia (external) with wall thickness not less than 1.8 mm with conduit accessories complete as specified. Note: All runs of cables and 1 run of conduit shall be measured and paid as one metre length of unit.
Supply and fixing DOUBLE AVIATION OBSTLIGHT LED RED with all necessary fitting complete all as specified and directed.
LIGHTNING PROTECTION
S & F LED red light DIE-CAST aluminimum housing with polycarbonate dome for better illumination with IP-65 protection fixed on wall with clamp by grouting angle iron of size 32x32x6 mm as required complete including suitable size of wiring to the nearest available point complete all as directed .
EARTHING
Material and labour for Maintenance free Chemical Earthing of technology 3 mtr long 25 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed.
Hem Construction Company (BID ID -3458150)
Som Projects Pvt. Ltd. (BID ID -3454058)
MC Gandhi and Sons (BID ID -3458384)
GEMINI PROMOTERS AND BUILDERS PVT. LTD. (BID ID -3454004)
SOOD ASSOCIATES PVT LTD (BID ID -3458397)
Varindera Constructions Limited (BID ID -3454339)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.44 MB
84201uploading.rar
Tender Documents • 5.00 MB
Drgs01to09.rar
Additional Documents • 23.05 MB
Drgugsump.rar
Additional Documents • 4.25 MB
Drgs10to26.rar
Additional Documents • 17.87 MB
Drg27totd23.rar
Additional Documents • 19.77 MB
BOQ_821497.xls
BOQ • 4.32 MB
Download all tender documents and submit your bid