Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.2 LAccepted-AOC RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | 1 | Accepted-AOC L1 | |
| 2 | 2₹13.4 L+₹25,584 (1.94%)Rejected-Finance | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹14.5 L+₹1.3 L (10.0%)Rejected-Finance CHANDPURA TIKAMGARH DIST TIKAMGARH MP | TIKAMGARH | TIKAMGARH | MADHYA PRADESH | 3 | Rejected-Finance Not Lowest | |
| 4 | 4₹14.7 L+₹1.5 L (11.2%)Rejected-Finance M S CHANANA ENGINEERS CONTRACTORS AZAD CHOWK FEROZEPUR CANTT FEROZEPUR PUNJAB 152001 | FIROZEPUR | PUNJAB | 152001 | 4 | Rejected-Finance Not Lowest | |
| 5 | 5₹15.6 L+₹2.4 L (18.4%)Rejected-Finance 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | 5 | Rejected-Finance Not Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Abohar
Garrison Engineer Abohar Pin - 152116
Repair maint including gen servicing of stand by gen sets at E/M installations at Mil Stn Abohar and Fazilka
2021_MES_415725_1
GE ABH-50/20-21
Open Tender
Civil Works
Item Rate
180 days
Abohar and Fazilka Mil Stn
MES Registered Contractor enlisted in class E Category b (i) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
5 documents required · 5 mandatory
₹500
Garrison Engineer Abohar
₹40,000
Yes
9 Apr 2021
23 Jan 2021
24 Feb 2021
23 Jan 2021
22 Feb 2021
8 Feb 2021
60 days
Amount
Servicing,repair maintenance of Diesel Gen Set of capacity 320 KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with 220 HP water cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing and checking of its all parts for serviceability and replacement of defective parts and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: KIRLOSKAR/MAHINDRA/RUSTON Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement in shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 2. Contractor should provide technical inspection of each DG Set by an engineer of corresponding make installed at site before supplying of material and incorporate the same at the site.
Fuel filter element (primary & secondry) Make: Kirloskar/Mahindra/Ruston
By pass filter element Make: Kirloskar/Mahindra/Ruston
Lube oil filter element Make: Kirloskar/Mahindra/Ruston
Air filter element of existing specification. Make: Kirloskar/Mahindra/Ruston
Radiator hose pipe set with clamp complete Make: Kirloskar/Mahindra/Ruston
Water temperature guage Make: Kirloskar/Mahindra/Ruston
Alternator Fan belt set Make: Kirloskar/Mahindra/Ruston
Alternator/Dynamo Make: Kirloskar/Mahindra/Ruston
Thermostat Make: Kirloskar/Mahindra/Ruston
Engine Mounting Foot (Flywheel Side) Make: Kirloskar/Mahindra/Ruston
Battery charging meter 12 VDC. Make: Kirloskar/Mahindra/Ruston
Stylus Make: Kirloskar/Mahindra/Ruston
Fixed Flange Make: Kirloskar/Mahindra/Ruston
Vertical Bellow Make: Kirloskar/Mahindra/Ruston
Servicing,repair maintenance of Diesel Gen Set of capacity 200 KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with 220 HP water cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing and checking of its all parts for serviceability and replacement of defective parts and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: KIRLOSKAR/MAHINDRA/RUSTON Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement in shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 2. Contractor should provide technical inspection of each DG Set by an engineer of corresponding make installed at site before supplying of material and incorporate the same at the site.
Fuel filter element (primary & secondry) Make: Kirloskar/Mahindra/Ruston
By pass filter element Make: Kirloskar/Mahindra/Ruston
Lube oil filter element Make: Kirloskar/Mahindra/Ruston
Air filter element of existing specification. Make: Kirloskar/Mahindra/Ruston
Alternator/Dynamo Make: Kirloskar/Mahindra/Ruston
Radiator hose pipe set with clamp complete Make: Kirloskar/Mahindra/Ruston
Water temperature guage Make: Kirloskar/Mahindra/Ruston
Alternator Fan belt set Make: Kirloskar/Mahindra/Ruston
Thermostat Make: Kirloskar/Mahindra/Ruston
Engine Mounting Foot (Flywheel Side) Make: Kirloskar/Mahindra/Ruston
Battery charging meter 12 VDC. Make: Kirloskar/Mahindra/Ruston
Stylus Make: Kirloskar/Mahindra/Ruston
Fixed Flange Make: Kirloskar/Mahindra/Ruston
Vertical Bellow Make: Kirloskar/Mahindra/Ruston
Servicing,repair maintenance of Diesel Gen Set of capacity 160 KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with 200 HP water cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing and checking of its all parts for serviceability and replacement of defective parts and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: KIRLOSKAR/MAHINDRA/RUSTON Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement in shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 2. Contractor should provide technical inspection of each DG Set by an engineer of corresponding MAKE installed at site before supplying of material and incorporate the same at the site.
Fuel filter element (primary & secondry) Make: Kirloskar/Mahindra/Ruston
By pass filter element Make: Kirloskar/Mahindra/Ruston
Lube oil filter element Make: Kirloskar/Mahindra/Ruston
Air filter element of existing specification. Make: Kirloskar/Mahindra/Ruston
Radiator hose pipe set with clamp complete Make: Kirloskar/Mahindra/Ruston
Alternator Fan belt set Make: Kirloskar/Mahindra/Ruston
Alternator/Dynamo Make: Kirloskar/Mahindra/Ruston
Thermostat Make: Kirloskar/Mahindra/Ruston
Engine Mounting Foot (Flywheel Side) Make: Kirloskar/Mahindra/Ruston
Fuel pipe any type length and specification. Make: Kirloskar/Mahindra/Ruston
Stylus Make: Kirloskar/Mahindra/Ruston
Dial Guage Make: Kirloskar/Mahindra/Ruston
Fixed Flange Make: Kirloskar/Mahindra/Ruston
Servicing,repair maintenance of Diesel Gen Set of capacity 125 KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with 150 HP Air cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing and checking of its all parts for serviceability and replacement of defective parts and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: KIRLOSKAR/MAHINDRA/RUSTON Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement in shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 2. Contractor should provide technical inspection of each DG Set by an engineer of corresponding MAKE installed at site before supplying of material and incorporate the same at the site.
Fuel filter element (primary & secondry) Make: Kirloskar/Mahindra/Ruston
By pass filter element Make: Kirloskar/Mahindra/Ruston
Lube oil filter element Make: Kirloskar/Mahindra/Ruston
Air filter element of existing specification. Make: Kirloskar/Mahindra/Ruston
Fan belt set Make: Kirloskar/Mahindra/Ruston
Push Button Make: Kirloskar/Mahindra/Ruston
Thermostat Make: Kirloskar/Mahindra/Ruston
Engine Mounting Foot (Flywheel Side) Make: Kirloskar/Mahindra/Ruston
Stylus Make: Kirloskar/Mahindra/Ruston
Vertical Bellow Make: Kirloskar/Mahindra/Ruston
Servicing,repair maintenance of Diesel Gen Set of capacity 100 KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with 125 HP water cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing and checking of its all parts for serviceability and replacement of defective parts and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: KIRLOSKAR/MAHINDRA/RUSTON Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement in shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 2. Contractor should provide technical inspection of each DG Set by an engineer of corresponding MAKE installed at site before supplying of material and incorporate the same at the site.
Fuel filter element (primary & secondry) Make: Kirloskar/Mahindra/Ruston
By pass filter element Make: Kirloskar/Mahindra/Ruston
Lube oil filter element Make: Kirloskar/Mahindra/Ruston
Air filter element of existing specification. Make: Kirloskar/Mahindra/Ruston
Radiator hose pipe set with clamp complete Make: Kirloskar/Mahindra/Ruston
Water temperature guage Make: Kirloskar/Mahindra/Ruston
Oil temperature guage Make: Kirloskar/Mahindra/Ruston
Oil pressure gauge Make: Kirloskar/Mahindra/Ruston
Fan belt set Make: Kirloskar/Mahindra/Ruston
Alternator Fan belt set Make: Kirloskar/Mahindra/Ruston
Shut down valve Make: Kirloskar/Mahindra/Ruston
Starting ignition switch Make: Kirloskar/Mahindra/Ruston
Push Button Make: Kirloskar/Mahindra/Ruston
Alternator/Dynamo Make: Kirloskar/Mahindra/Ruston
Thermostat Make: Kirloskar/Mahindra/Ruston
Engine Mounting Foot (Flywheel Side) Make: Kirloskar/Mahindra/Ruston
Fuel pipe any type length and specification. Make: Kirloskar/Mahindra/Ruston
Battery charging meter 12 VDC. Make: Kirloskar/Mahindra/Ruston
Dial Guage Make: Kirloskar/Mahindra/Ruston
Servicing,repair maintenance of Diesel Gen Set of capacity 75 KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with 92.5 HP water cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing and checking of its all parts for serviceability and replacement of defective parts and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: KIRLOSKAR/MAHINDRA/RUSTON Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement in shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 2. Contractor should provide technical inspection of each DG Set by an engineer of corresponding MAKE installed at site before supplying of material and incorporate the same at the site.
Fuel filter element (primary & secondry) Make: Kirloskar/Mahindra/Ruston
By pass filter element Make: Kirloskar/Mahindra/Ruston
Lube oil filter element Make: Kirloskar/Mahindra/Ruston
Supply and replacement of Air filter element of existing specification. Make: Kirloskar/Mahindra/Ruston
Fan belt set Make: Kirloskar/Mahindra/Ruston
Alternator Fan belt set Make: Kirloskar/Mahindra/Ruston
Alternator/Dynamo Make: Kirloskar/Mahindra/Ruston
Thermostat Make: Kirloskar/Mahindra/Ruston
Stylus Make: Kirloskar/Mahindra/Ruston
Servicing,repair maintenance of Diesel Gen Set of capacity 62.5/63 KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with 83 HP water cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing and checking of its all parts for serviceability and replacement of defective parts and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: KIRLOSKAR/MAHINDRA/RUSTON Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement in shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 2. Contractor should provide technical inspection of each DG Set by an engineer of corresponding MAKE installed at site before supplying of material and incorporate the same at the site.
Fuel filter element (primary & secondry) Make: Kirloskar/Mahindra/lumax
By pass filter element Make: Kirloskar/Mahindra/Ruston
Lube oil filter element Make: Kirloskar/Mahindra/Ruston
Air filter element of existing specification. Make: Kirloskar/Mahindra/Ruston
Radiator hose pipe set with clamp complete Make: Kirloskar/Mahindra/Ruston
Water temperature guage Make: Kirloskar/Mahindra/Ruston
Oil temperature guage Make: Kirloskar/Mahindra/Ruston
Oil pressure gauge Make: Kirloskar/Mahindra/Ruston
Fan belt set Make: Kirloskar/Mahindra/Ruston
Alternator Fan belt set Make: Kirloskar/Mahindra/Ruston
Shut down valve Make: Kirloskar/Mahindra/Ruston
Starting ignition switch Make: Kirloskar/Mahindra/Ruston
Push Button Make: Kirloskar/Mahindra/Ruston
Alternator/Dynamo Make: Kirloskar/Mahindra/Ruston
Thermostat Make: Kirloskar/Mahindra/Ruston
Engine Mounting Foot (Flywheel Side) Make: Kirloskar/Mahindra/Ruston
Fuel pipe any type length and specification. Make: Kirloskar/Mahindra/Ruston
Battery charging meter 12 VDC. Make: Kirloskar/Mahindra/Ruston
Stylus Make: Kirloskar/Mahindra/Ruston
Dial Guage Make: Kirloskar/Mahindra/Ruston
Fixed Flange Make: Kirloskar/Mahindra/Ruston
Vertical Bellow Make: Kirloskar/Mahindra/Ruston
Servicing,repair maintenance of Diesel Gen Set of capacity 40 KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with 50 HP water cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing and checking of its all parts for serviceability and replacement of defective parts and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: KIRLOSKAR/MAHINDRA/RUSTON Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement in shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 2. Contractor should provide technical inspection of each DG Set by an engineer of corresponding MAKE installed at site before supplying of material and incorporate the same at the site.
Fuel filter element (primary & secondry) Make: Kirloskar/Mahindra/Ruston
By pass filter element Make: Kirloskar/Mahindra/Ruston
Lube oil filter element Make: Kirloskar/Mahindra/Ruston
Supply and replacement of Air filter element of existing specification. Make: Kirloskar/Mahindra/Ruston
Water temperature guage Make: Kirloskar/Mahindra/Ruston
Oil temperature guage Make: Kirloskar/Mahindra/Ruston
Oil pressure gauge Make: Kirloskar/Mahindra/Ruston
Fan belt set Make: Kirloskar/Mahindra/Ruston
Shut down valve Make: Kirloskar/Mahindra/Ruston
Starting ignition switch Make: Kirloskar/Mahindra/Ruston
Push Button Make: Kirloskar/Mahindra/Ruston
Alternator/Dynamo Make: Kirloskar/Mahindra/Ruston
Thermostat Make: Kirloskar/Mahindra/Ruston
Engine Mounting Foot (Flywheel Side) Make: Kirloskar/Mahindra/Ruston
Fuel pipe any type length and specification. Make: Kirloskar/Mahindra/Ruston
Battery charging meter 12 VDC. Make: Kirloskar/Mahindra/Ruston
Stylus Make: Kirloskar/Mahindra/Ruston
Dial Guage Make: Kirloskar/Mahindra/Ruston
Fixed Flange Make: Kirloskar/Mahindra/Ruston
Vertical Bellow Make: Kirloskar/Mahindra/Ruston
Servicing,repair maintenance of Diesel Gen Set of capacity 25/30 KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with 40 HP water cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing and checking of its all parts for serviceability and replacement of defective parts and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: KIRLOSKAR/MAHINDRA/RUSTON Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement in shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 2. Contractor should provide technical inspection of each DG Set by an engineer of corresponding make installed at site before supplying of material and incorporate the same at the site.
Fuel filter element (primary & secondry) Make: Kirloskar/Mahindra/Ruston
By pass filter element Make: Kirloskar/Mahindra/Ruston
Lube oil filter element Make: Kirloskar/Mahindra/Ruston
Supply and replacement of Air filter element of existing specification. Make: Kirloskar/Mahindra/Ruston
Radiator hose pipe set with clamp complete Make: Kirloskar/Mahindra/Ruston
Water temperature guage Make: Kirloskar/Mahindra/Ruston
Oil temperature guage Make: Kirloskar/Mahindra/Ruston
Oil pressure gauge Make: Kirloskar/Mahindra/Ruston
Fan belt set Make: Kirloskar/Mahindra/Ruston
Alternator Fan belt set Make: Kirloskar/Mahindra/Ruston
Shut down valve Make: Kirloskar/Mahindra/Ruston
Starting ignition switch Make: Kirloskar/Mahindra/Ruston
Push Button Make: Kirloskar/Mahindra/Ruston
Alternator/Dynamo Make: Kirloskar/Mahindra/Ruston
Thermostat Make: Kirloskar/Mahindra/Ruston
Engine Mounting Foot (Flywheel Side) Make: Kirloskar/Mahindra/Ruston
Fuel pipe any type length and specification. Make: Kirloskar/Mahindra/Ruston
Battery charging meter 12 VDC. Make: Kirloskar/Mahindra/Ruston
Stylus Make: Kirloskar/Mahindra/Ruston
Dial Guage Make: Kirloskar/Mahindra/Ruston
Fixed Flange Make: Kirloskar/Mahindra/Ruston
Vertical Bellow Make: Kirloskar/Mahindra/Ruston
Servicing,repair maintenance of Diesel Gen Set of capacity 15 KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with 20 HP water cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing and checking of its all parts for serviceability and replacement of defective parts and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: KIRLOSKAR/MAHINDRA/RUSTON Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement in shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 2. Contractor should provide technical inspection of each DG Set by an engineer of corresponding MAKE installed at site before supplying of material and incorporate the same at the site.
Air filter element (primary & secondry) Make: Kirloskar/Mahindra/Ruston
By pass filter element Make: Kirloskar/Mahindra/Ruston
Lube oil filter element Make: Kirloskar/Mahindra/Ruston
Supply and replacement of Air filter element of existing specification. Make: Kirloskar/Mahindra/Ruston
Radiator hose pipe set with clamp complete Make: Kirloskar/Mahindra/Ruston
Water temperature guage Make: Kirloskar/Mahindra/Ruston
Oil temperature guage Make: Kirloskar/Mahindra/Ruston
Oil pressure gauge Make: Kirloskar/Mahindra/Ruston
Fan belt set Make: Kirloskar/Mahindra/Ruston
Alternator Fan belt set Make: Kirloskar/Mahindra/Ruston
Shut down valve Make: Kirloskar/Mahindra/Ruston
Starting ignition switch Make: Kirloskar/Mahindra/Ruston
Push Button Make: Kirloskar/Mahindra/Ruston
Alternator/Dynamo Make: Kirloskar/Mahindra/Ruston
Thermostat Make: Kirloskar/Mahindra/Ruston
Engine Mounting Foot (Flywheel Side) Make: Kirloskar/Mahindra/Ruston
Fuel pipe any type length and specification. Make: Kirloskar/Mahindra/Ruston
Battery charging meter 12 VDC. Make: Kirloskar/Mahindra/Ruston
Stylus Make: Kirloskar/Mahindra/Ruston
Dial Guage Make: Kirloskar/Mahindra/Ruston
Fixed Flange Make: Kirloskar/Mahindra/Ruston
Vertical Bellow Make: Kirloskar/Mahindra/Ruston
Servicing,repair maintenance of Diesel Gen Set of capacity 5 KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with 12 HP water cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing and checking of its all parts for serviceability and replacement of defective parts and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: KIRLOSKAR/MAHINDRA/RUSTON Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement in shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 2. Contractor should provide technical inspection of each DG Set by an engineer of corresponding MAKE installed at site before supplying of material and incorporate the same at the site.
Fuel filter element (primary & secondry) Make: Kirloskar/Mahindra/Ruston
By pass filter element Make: Kirloskar/Mahindra/Ruston
Lube oil filter element Make: Kirloskar/Mahindra/Ruston
Radiator hose pipe set with clamp complete Make: Kirloskar/Mahindra/Ruston
Oil temperature guage Make: Kirloskar/Mahindra/Ruston
Oil pressure gauge Make: Kirloskar/Mahindra/Ruston
Fan belt set Make: Kirloskar/Mahindra/Ruston
Shut down valve Make: Kirloskar/Mahindra/Ruston
Starting ignition switch Make: Kirloskar/Mahindra/Ruston
Thermostat Make: Kirloskar/Mahindra/Ruston
Engine Mounting Foot (Flywheel Side) Make: Kirloskar/Mahindra/Ruston
Fuel pipe any type length and specification. Make: Kirloskar/Mahindra/Ruston
Air filter element of existing specification. Make: Kirloskar/Mahindra/Ruston
Battery charging meter 12 VDC.
M & L servicing and cleaning of radiator assy with cleaning solution soldering of puncture tubes to stop leakage,testing of DG Set of following capacity mentioned below here in after as required at site and directed by Engr-in-Charge.
M& L for servicing calibration and testing of injector assembly incl replacement of barrels plungers cups injector and commissioning the same as required at site of DG Set of following capacity mentioned below here in after complete all as specified and directed by Engr-in-Charge.
Servicing,decarbonising ,refacing of strip opening cylinder head and polishing of valve seat complete refixing after satisfactory repairs installing valve and valve guides including replacement of head packing and valves repairing kit containing valve seat, valve spring and other items as required at site of DG Set of following capacity mentioned below here in after all as specified and directed by Engr-in-Charge.
M&L for servicing ,repair and overhauling of self starter 12 V DC complete replacement of worn out fields , armature, solenoid and bendex pinion along with carbon brushes etc of DG Set of following capacity mentioned below here in after complete in all respect all as directed.
M&L for servicing ,repair and overhauling of self starter 24 V DC complete replacement of worn out fields , armature, solenoid and bendex pinion along with carbon brushes etc of DG Set of following capacity mentioned below here in after complete in all respect all as directed.
M & L maint,servicing, cleaning and calibration of governor assembly complete including spare and repair kit of DG Set of capacity following capacity mentioned below here in after all as specified and directed by engineer -in-charge.
Supply and fixing muffler (exhaust silencer) of existing specification suitable for DG Set of following capacity mentioned below here in after complete all as specified and directed by engineer in charge. Make : KIRLOSKAR/MAHINDRA/ RUSTON
Dismantling, taking done and repairing of water pump assembly of including replacement of pump pully and bearing of DG Set of following capacity mentioned below here in after complete all as specified and directed by Engr-in-Charge.
Servicing concentricity alignment complete with replacement of necessary parts and calculating the maximum and minimum revolution on dial guage having a difference of reading less than or equal to 0.3mm of DG Set of following capacity mentioned below here in after complete all as specified and directed by Engr-in-Charge.
Complete servicing and cleaning of contact points of Voltage and current regulator by using emery paper(LUCAS-TVS Electronic Contact Cleaner can be used) of DG Set of following capacity mentioned below here in after complete all as specified and directed by Engr-in-Charge.
Complete servicing and repairing of starting motor of engine including cleaness and tightness of all electrical connections, mounting bolts, bushes, brush spring and checking spring pressure should be within 0.965 to 1.080 kg and testing complete of DG Set of following capacity mentioned below here in after all as specified and directed by Engg-in-charge.
Supply and fixing new DC battery 12 Volts,180 AH fully charged ensuring right polarity of lead connection complete all as specified and directed by Engg-in-Charge.
Supply and fixing new battery 12 Volts, 92 AH fully charged ensuring right polarity of lead connection complete all as specified and directed by Engg-in-Charge. Make: Exide/Amron
M&L for servicing ,repair and charging of battery 12 V DC complete checking of battery and lead connection,tightening of clamping bolts including washing of corroded terminals with ammonia soluation consist of 115 gms of backing soda ensuring cleaning soluation does not enter into vent holes and apply petroleum jelly on terminals including electrolyte solution level high enough to touch top edge of lead plates having specific gravity of 1.28 kg/l complete in all respect all as directed by Engg-in-Charge.
Supply and fixing of 12 V self starting motor of engine coupled with DG set including tightness of all electrical connections, mounting bolts and testing complete all as specified and directed by Engg-in-charge.
Supply and fixing of 24 V self starting motor of engine coupled with 320 KVA DG set including tightness of all electrical connections, mounting bolts and testing complete all as specified and directed by Engg-in-charge.
M&L for draining out old engine oil from DG Sets and supply and refilling 20W40 new engine oil to DG Sets complete all as specified and directed by engineer in charge
M&L for draining out old coolant from DG Sets and supply and refilling DAFC 30% new coolant to DG Sets complete all as specified and directed by engineer in charge
Supply and fixing ON LOAD Change over switches, 4 pole 415 volts of capacity 63 Amps complete taking down old unserviceable and making necessary connections including all provisions for fixing in panel compartments as existing using necessary links of suitable metals and cleaning the terminals with CTC solutions complete all as specified and directed by Engr-In-Charge .
All as per Ser Item No 30 but 100 Amps rating
All as per Ser Item No 30 but 150 Amps rating
All as per Ser Item No 30 but 200 Amps rating
All as per Ser Item No 30 but 400 Amps rating
All as per Ser Item No 30 but 630 Amps rating
Earthing complete with galvanised steel earth plate electroe 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connectedto and including galvanized earth lead GI Strip of size 32x6mm by means of GI bolt/snuts/washers, protected by 40mm bore GI light grade pipe from earth plate & upto 3m long .Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around buttom and top of earth plate 20mm dia GI pipe medium grade for watering and including funnel, wire mesh, RCC cover & frame PCC 1:3:6 type C1 using 20mm graded stone aggregate as in earthing pit including necessary excavation & earth work all as specified & shown on electrical plate No. 3 of SSR Part-I, (Note: (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3½ core
do-- but size 150 sq mm 3½ core
do-- but size 120 sq mm 3½ core
do-- but size 95 sq mm 3½ core
do-- but size 70 sq mm 3½ core
do-- but size 50 sq mm 3½ core
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for sand cushioning for protection of PVC cable with screen wash river sand and punning to proper required cover.
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat.
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for 0.4 mpa working pressure for cable passing without damaging existing Raod/path/hardstanding/floor by trenchless technology or manual using necessary equipment complete all as specified and directed.
M&L for 50mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed. (MAKE: JINDAL/PRAKASH/SURYA)
S & F GI tube light grade galvanised of size 80 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge.
M&L for cutting the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe complete all as directed by the Engr. in Charge.
Supply and fixing MCCB TPN/TP 415 Volts of rating 315 Amps of braking capacity 36 KA of 3 pole confirming to (Adjustable Thermal and Magnetic Release Setting with short circuit settings) complete taking down old unserviceable one and making necessary connections including all provisions for fixing in panel compartments as existing using necessary links of suitable metals and cleaning the terminals with CTC solutions complete all as specified and directed. Make : Havells/Legrand/IndoAsian (optium 2.0)/Schneider/HPL/Standard
All as per item No.52 above but of rating 250 Amps with braking capacity 36 KA. Make Havells/Legrand.
All as per item No.52 above but of rating 200 Amps with braking capacity 36 KA. Make : Havells/Legrand
All as per item No.52 above but of rating 125 Amps with braking capacity 36 KA. Make : Havells/Legrand
All as per item No.52 above but of rating 400 Amps with braking capacity 50 KA. Make : Havells/Legrand
All as per item No.52 above but of rating 500 Amps with braking capacity 50 KA. Make : Havells/Legrand
All as per item No.52 above but of rating 160 Amps with braking capacity 36 KA. Make : Havells/Legrand
All as per item No.52 above but of rating 100 Amps with braking capacity 36 KA. Make : Havells/Legrand
All as per item No.52 above but of rating 63 Amps with braking capacity 36 KA. Make : Havells/Legrand
All as per item No.52 above but of rating 100 Amp, 10 KA 415 Volt in repair. Make : Havells/Legrand
All as per item No.52 above but of rating 63 Amp, 10 KA 415 Volt in repair. Make : Havells/Legrand
HARSH CONSTRUCTION CO.
POOJA CONSTRUCTION COMPANY
Chanana Engineers & Contractors
jassal engineering
VINOD ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .