Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | ₹23.5 L Quoted ₹24.6 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹25.7 L+₹1.1 L (4.38%)Rejected-Finance NOT AVAILABLE | ₹25.7 L+₹1.1 L (4.38%) | L2 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 3 | L3₹26.3 L+₹1.6 L (6.59%)Rejected-Finance NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | ₹26.3 L+₹1.6 L (6.59%) | L3 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 4 | L4₹27.7 L+₹3.1 L (12.5%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | ₹27.7 L+₹3.1 L (12.5%) | L4 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 5 | L5₹28.5 L+₹3.9 L (15.7%)Rejected-Finance WAR NO 3 DHEMAJI TOWN PO DIST DHEMAJI ASSAM 787057 | DHEMAJI | ASSAM | 787057 | ₹28.5 L+₹3.9 L (15.7%) | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
| Sl No | Description | Qty | Unit | Shri Debajyoti Das L5 | M/S SINGH TRADERS L3 | ms singh construction L4 | MANASEE L1 | SATYA CHANGMAI L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets except light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. | 70 | Point | 48 ₹3,360 | 35 ₹2,450 | 60 ₹4,200 | 45 ₹3,150 | 22 ₹1,540 Lowest |
| 2.00 | Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed. | 12 | Each | 46 ₹552 | 45 ₹540 | 48 ₹576 | 46 ₹552 | 40 ₹480 Lowest |
| 3.00 | Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. | 75 | RM | 49 ₹3,675 | 47 ₹3,525 | 50 ₹3,750 | 40 ₹3,000 | 15 ₹1,125 Lowest |
| 4.00 | M & L for Point wiring for one light/exhaust fan/fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.
(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) | 25 | Point | 1,350 ₹33,750 | 1,450 ₹36,250 | 1,350 ₹33,750 | 1,350 ₹33,750 | 1,065 ₹26,625 Lowest |
| 5.00 | All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto | 25 | Point | 1,260 ₹31,500 | 1,250 ₹31,250 | 1,200 ₹30,000 | 1,120 ₹28,000 | 1,100 ₹27,500 Lowest |
| 6.00 | All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto | 20 | Point | 285 ₹5,700 Lowest | 300 ₹6,000 | 300 ₹6,000 | 290 ₹5,800 | 300 ₹6,000 |
| 7.00 | All as per item No. 04 above but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto | 20 | Point | 1,500 ₹30,000 | 1,450 ₹29,000 | 1,500 ₹30,000 | 1,590 ₹31,800 | 1,334 ₹26,680 Lowest |
| 8.00 | S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed. | 45 | Each | 65 ₹2,925 | 50 ₹2,250 Lowest | 65 ₹2,925 | 58 ₹2,610 | 55 ₹2,475 |
| 9.00 | S & F Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts complete all as specified and directed. | 25 | Each | 200 ₹5,000 | 190 ₹4,750 Lowest | 200 ₹5,000 | 195 ₹4,875 | 190 ₹4,750 Lowest |
| 10.00 | S & F Socket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed. | 20 | Each | 220 ₹4,400 | 140 ₹2,800 | 180 ₹3,600 | 90 ₹1,800 | 88 ₹1,760 Lowest |
Tender Value
₹23.8 L
EMD Value
₹47,600
Closing Date
28 Aug 2025, 6:00 pmClosed
GE 872 EWS
GE 872 EWS, C/O 99 APO
REPAIR/ MAINT OF INTERNAL ELECTRIFICATION, REPAIR/ MAINT OF LT EXTERNAL ELECTRIFICATION, REPAIR MAINT OF HT EXTERNAL ELECTRIFICATION, REPAIR/ MAINT/ SERVICING TO VARIOUS TYPE FANS, REPAIR/ MAINT/ SERVICING TO COOLING APPLIANCES, REPAIR/ MAINT TO LT P
2025_MES_725028_1
8785/E8
Open Tender
Civil Works
Item Rate
270 days
NLP
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹47,600
Yes
17 Oct 2025
7 Aug 2025
30 Aug 2025
7 Aug 2025
28 Aug 2025
21 Aug 2025
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets except light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
M & L for Point wiring for one light/exhaust fan/fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.)
All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 04 above but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
S & F Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed.
S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed.
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
S & F in repairs LED Bulk Head, 10 Watt, IP 65 rated, with pressure die cast aluminium housing and acrylic diffuser, CCT: WW/NW/CW, CRI > 80 Ra, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LBLK02X010XC or equivelant of make as per list of manufacturer)
S & F in repair Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. LHEXBLP7PN1W020 or equivelant of make as per list of manufacturer)
S & F in repairs LED Bulb, 9 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed.
S & F in repairs LED Bulb, 15 Watts, B-22 Lumen ≥ 1200, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed.
S & F in repair 2ftx2ft recessed mounting, LED panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 12 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNEP01R012XC or equivelant of make as per list of manufacturer)
S & F in repair Surface and wall mounted LED batten, 10W, 220V, AC, 2 feet, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10% including lamp, fixing accessories and connecting up complete all as specified and directed. (Make : Havell's Cat No. ENDURALINEARNEOBS10WLED865SPCWH and equivelant model of make as specified in list of manufacturer).
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casing capping of suitable size with all accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of casin capping shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casin capping of suitable size with all accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of casin capping shall be measured as one length)
S & F in repair Rigid non-metalic PVC casing capping of size 25mm inclusive of all fittings and fixing accessories complete all as specified and directed.
S & F in repair Rigid non-metalic PVC casing capping of size 32mm inclusive of all fittings and fixing accessories complete all as specified and directed.
S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed.
S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep complete all as specified and directed.
S & F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F sheet metal enclosure, single door MCB DBs, phosphatised, powder coated, Single pole & neutral (SPN), 02 way, 240 Volts suitable for housing MCBs with din rail, neutral and earth bar in proper psoition complete all as specified and directed.
S & F Distribution Board, SPN 4 Way, 240V, Double door with IP 43 protection complete all as specified and as directed. (Make: Havell's cat part No. DHDNSHODAW04 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer's)
S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)
S & F MCB SP 40 Amps, 240 Volts, 10KA, B Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGBSPF040 or equivalent make as per List of Manufacturer's)
S & F MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed Havell's cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer's)
S & F MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF040-63 or equivalent make as per List of Manufacturer's)
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia TMT bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
Taking down and dismantling the ceiling fan 1200 / 1400 mm sweep of any capacity from existing position and removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers etc complete including provn flexible copper conductor cable of 24 / 0.20mm of required length with necessary connector (for blade / body) as required after rewinding complete all as specified and directed. (Note : (i) Spare parts shall be measured and paid seperately as supply only and rewinding of fan shall be measured and paid seperatly under relevant item here-in-below. (ii) The cleaning, servicing, oiling and lubricating of fans has to be carried at site itself and to be completed withing one hour unless re-winding is required. (iii) The cost of transportation from site of work to workshop and back for rewinding is deemed to be included in the unit quoted rate, (iv) Rewinding shall be carried out in contractor's workshop and fan shall be re-fixed at site withing 10 days after taking down from site. Any delay after 10 days shall be panalised @ Rs. 100.00 per day for a maximum of 10 days).
All as per Serial item No. 38 above but exhaust fan of 300/380mm sweep of any capacity complete ditto.
All as per Serial item No. 38 above but air circulators/ pedestal fan/ wall mounting fan of any sweep and any capacity complete ditto.
M & L for rewinding of Ceiling fan of any sweep after dismantling with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassembling and testing etc complete all as specified and as directed. ( Note: Also refer Note No. (iv) under Serial item No. 38 above)
All as per serial item No. 41 above but exhaust fan of 300/380mm sweep complete ditto
All as per serial item No. 41 above but aircirculator/ pedestal fan/ wall mounted fan of any sweep complete ditto
Supply only ball bearing suitable for Ceiling fan of any sweep complete all as per the existing specifications and as directed (Make :TATA/ SKF / NBC)
Supply only capacitor of 2.0/2.5 Mfd suitable for ceiling fan and wall mounted fan of any make and size complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
Supply only blades set suitable for ceiling fan 1200 / 1400 mm sweep any make, powder cuoted aluminium, Areo dynamically balanced and Mild steel screws of suitable size complete all as per existing specification and as directed.
Supply only brass bush suitable for ceiling fan/exhaust fan/ cabin fan of any sweep and capapcity complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 18" long, heavy duty, duly powder coated with matching colour of fan including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 24" long, heavy duty, duly powder coated with matching colour of fan including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 36" long, heavy duty, duly powder coated with matching colour of fan including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
S & F in repairs mild steel frame suitable for exhuast fan 300/380mm sweep with mild steel flat fixed with nuts, bolts, washer including necessary powder coated Complete all as per the existing specification and as directed.
S & F in repairs stationary louvers complete with frame suitable for exhaust fan of 300/380mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed.
M & L for preparation of old painted surfaces of ceiling fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed. (Note: The ceiling fan taken down under Serial item No. 38 above shall be painted and measured under this item.)
Taking down the existing storage type water heater of any capacity of any type and size by disconnecting electric connection, carring out following necessary repair work, tinkering and welding etc. including de-scaling, brushing and thoroughly cleaning the storage tank/inner water tank, removing of hard water deposits, and connected back and re-fixing in orignal position, grounting, testing and commissioning, complete with entire satisfection of Engr-in-Charge:- (a) Checking of all stop cock, pressure release valve, fusible plug etc to ensure free functioning of the parts including Supply and replacement of washer/gasket, nuts etc as required. (b) Inspect overflaw and vent pipes and remove blockages (if any) (c) Checking and rectify earth continuity of the electrical circuits of the geyser and power points (d) Check, maintain and re-fixing thermostat and re-adjust (e) Visual examination of of fusible plugs for its serviceability (f) De-scaling the immersion type heating element and siphon assembly with diluted hydrochloride acid or cear pedette solution (g) Checking of indicator lamp for its serviceability (Note: (i) Spare parts/components of geysers shall be measured and paid seperately as "supply only" under respective items here-in-below. (ii) Any minor parts required for smooth functioning of the geyser shall be provided by the contractor without any extra cost to the Govt. (iii) Painting of geyser shall be measured and paid seperately)
Supply only heating element, 1.5KW capapcity, AC 230 volts, pressed/screw/triangular/ceramic type, ISI marked complete all as specified and directed.
Supply only heating element, 2KW capapcity, AC 230 volts, pressed/screw/triangular/ceramic type, ISI marked complete all as specified and directed.
Supply only indicator lamp, retangular/round shape, blue/green/red colour suitable for geyser 25 ltrs capacity complete all as specified and directed.
Supply only high pressure safety valve/high pressure release valve, dead weight type suitable for geyser of any make and model, ISI marked complete all as directed.
Supply only thermostate switch with thermal setting 40 to 90 degree capacity and relay, 230 Volts, ISI Marked complete all as specified and directed.
Supply only glass wools of approved quality as insulating materials in geyser complete all as directed.
Supply only fusible plug complete all as per the existing specifications suitable for water heater of capacity 25 Ltrs complete all as specified and directed.
Supply only Base assembly gasket of any shape and size complete all as per the existing specifications suitable for water heater of capacity 25 Ltrs complete all as specified and directed.
Supply only Inner Shell (Inner tank), ISI marked made out of copper sheet 20 to 22 guage thick complete all as per the existing specifications suitable for water heater of capacity 25 Ltrs complete all as specified and directed.
S & F In repairs, base assembly (inner, chromium plated brass, any shape and size with inlet, outlet, thermostate slot, drain plug and clamp or bolts for fixing heating element as per the existing shape suitable for electric water heater of 25 Litres capacity including necessary powder coating complete all as specified and as directed.
S & F In repairs, outer body complete with top & bottom cover, inspection plate suitable for electric water heater of capacity 25 Litres of any make/model duly powder coated complete all as specified and as directed.
S & F in repair chromium plated brass connection tube, 450cm long with two brass union and check nuts for connections to 15mm bore pipe suitable for hot & cold water complete all as specified and directed.
S & F in repairs 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed.
S & F in repairs plug top, 20 Amps, 3 pin including making connections to existing cables complete all as specified and directed.
S & F in repairs plug top, 6 Amps, 3 pin including making connections to existing cables complete all as specified and directed.
S & F in repairs metal clad top, 2 pole & earth, 20 Amps including making connections to existing cables complete all as specified and directed.
Supply and fixing PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 of size 4 Sqmm 3 core nominal cross sectional area including taking out old one complete all as specified and directed.
S & F in repair Compressor sealed Unit, Rotary type complete all as per the existing make and model, suitable for Split AC 1.5 TR capacity Outdoor Unit complete all as specified and as directed.
S & F in repair heavy duty condenser fan blade assembly for fan motor of appropriate size complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacity complete all as specified and as directed.
S & F in repair Indoor motor, single phase, 230 volts complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacity complete all as specified and as directed.
S & F in repair Outdoor motor, single phase, 230 volts complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacity complete all as specified and as directed.
S & F in repair Insulation on and around suction and discharge copper piping with 6.0mm thick flexible Thermo Cool Heat Resistant of best quality (as approved) duly scraped with sticking tape complete all as specified and as directed.
S & F in repair copper tubing of 5/8" and 3/8" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
Supply only copper tubing of 1/2" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in repair Brass flare nut for copper tubing of 1/2"/ 3/8" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
Repair to Power Circuit (PC Plate) of Split AC 1.5 TR capacity to make the PC plate fully functional complete all as directed by the Engr-in-Charge.
Repair to Power Circuit (PC Plate) of Split AC 2.0 TR capacity to make the PC plate fully functional complete all as directed by the Engr-in-Charge.
S & F in repair Power Circuit (PVC Plate) complete all as per the existing make and model, suitable for Split AC 1.5 capacity complete all as specified and as directed.
S & F in repair Power Circuit (PVC Plate) complete all as per the existing make and model, suitable for Split AC 2.0 capacity complete all as specified and as directed.
S & F in repair Remote Auto Sensor Unit & RC, complete all as per the existing make and model, suitable for Split/Window AC 1.5/2.0 TR capacity complete all as specified and as directed.
Supply and Changing Refrigerant F-22 to Split ype AC 1.5/2.0 T capacity including servicing of any make & model including brazing to stop any leakage and required pressure testing complete all as specified and as directed.
M & L for shifting of Indoor/outdoor unit of Split AC 1.5/2.0 TR capacity to another locations as directed (including taking down and reinstallation) with all accessories including necessary welding, brazing to stop leakages , vaccum test pressure, testing, inserting thick flexible thermo cool and servicing of indoor and outdoor unit and testing complete all as specified and as directed. (Note: Charging of gas shall be measured and paid seperately)
M & L for dismantling of Voltage stabilizer 2.0/3.0 KVA capacity, single phase, 240 Volts AC, repairing as required, replacement of burnt transformer, copper wounded, electronic circuit, relays, indicator light, voltmeter, display, switch and socket etc to make the stabilizer fully functional and re-assmebling and re-instal the same and testing on completion complete all as specified and as directed. (Note: (i) Cost of all materials and labour element required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
M & L for dismantling of Voltage stabilizer 4/5 KVA capacity, single phase, 240 Volts AC, repairing as required, replacement of burnt transformer, copper wounded, electronic circuit, relays, indicator light, voltmeter, display, switch and socket etc to make the stabilizer fully functional and re-assmebling and re-instal the same and testing on completion complete all as specified and as directed. (Note: (i) Cost of all materials and labour element required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
S & F in repairs sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp, 240V, B-curve complete all as specified and as directed.
M & L for Opening of defective Refrigerator of any capacity/ Make/ Model/ Type, removal of blockage by flushing out, Brazing (as required) and making the system fully leakage proof, replacing unserviceable compressor and other parts, complete servicing of the system and re-assembling after necessary repair work and testing on completion complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts such as compressor and other parts and charging of Refrigerant as required shall be measured and paid seperately as "Supply only" under respective item and labour element for the same shall deemed to be included in the unit quoted rate (ii) Replacement of minor spares/ parts as required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
Supply only Overload protection Relay complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
Supply only Compressor Sealed Unit complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
Supply only Pigmy bulb complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
Supply only Freeze assembly complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
Supply only Door gasket magnetic type complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
Supply only Relay, open type, 1/6 HP complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
Supply only Chilled freezer tray complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
Supply only Vegetable tray complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
Supply only PVC ice tray complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
Supply and Changing Refrigerant F-12 to water cooler of 40/80 Ltr capacity capacity including servicing of any make & model including brazing to stop any leakage and required pressure testing complete all as specified and as directed.
Supply and Changing Refrigerant F-22 to Deep freezer of 320 Ltr capacity capacity including servicing of any make & model including brazing to stop any leakage and required pressure testing complete all as specified and as directed.
S & F in repair Fan blade assembly heavy duty complete all as per the existing make and model, suitable for Water cooler of any capacity complete all as specified and as directed.
S & F in repair Fan motor, 1/35 or 1/32 HP capacity complete all as per the existing make and model, suitable for Water cooler of any capacity complete all as specified and as directed.
S & F in repair Starting kit comprising of relay and overload protector complete all as per the existing make and model, suitable for Water cooler of any capacity complete all as specified and as directed.
S & F in repair Thermostat switch complete all as per the existing make and model, suitable for Water cooler of any capacity complete all as specified and as directed.
S & F in repair PVC drain pipe, 32mm dia, 1.0m long, heavy duty with two Nos galvanised adjustable clamps complete all as per the existing make and model, suitable for Water cooler of any capacity complete all as specified and as directed.
S & F in repair Starting capacitor 40/60 mfd complete all as per the existing make and model, suitable for Water cooler of any capacity complete all as specified and as directed.
S & F in repair Compressor Sealed Unit complete all as per the existing make and model, suitable for Water Cooler of 40/80 Litre capacity complete all as specified and as directed.
S & F in repair Running capacitor 10 mfd complete all as per the existing make and model, suitable for Water cooler of any capacity complete all as specified and as directed.
S & F in repair PVC float valve 15mm bore, suitable to fit with water cooler of any capacity complete all as specified and as directed.
S & F in repair Overload Protector to compressor sealed unit complete all as per the existing make and model, suitable for Water Cooler of any capacity complete all as specified and as directed.
S & F in repair 15mm bore, Push cock, brass, chromium plated having inner and outer threaded and fixed to water cooler complete all as specified and as directed.
M & L for preparation of outer surfaces of water cooler of any capacity after denting/welding, cleaning the surface thoroughly and applying one coat of approved spray painting including writing MES Nos complete all as specified and as directed.
Supply and fixing PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 of size 3 core 40/0.0076 nominal cross sectional area including taking out old one complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches not exc. 1.5 metre wide and exc. 1.5 metre & not exc. 3 metre depth (beyond the first 1.5 metre) for foundation of poles etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supply and laying locally available best quality, well burnt sub class B bricks (old size), laid dry in trenches for protection of UG cables complete all as specified and directed.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work shall be measured paid seperately)
All as per Serial item No. 121 above but 10 Sqmm 4 Core cable complete ditto
All as per Serial item No. 121 above but 16 Sqmm 4 Core cable complete ditto
All as per Serial item No. 121 above but 50 Sqmm 3.5 Core cable complete ditto
All as per Serial item No. 121 above but 70 Sqmm 3.5 Core cable complete ditto
All as per Serial item No. 121 above but 95 Sqmm 3.5 Core cable complete ditto
All as per Serial item No. 121 above but 120 Sqmm 3.5 Core cable complete ditto
All as per Serial item No. 121 above but 185 Sqmm 3.5 Core cable complete ditto
S & F in repair Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and ccessories suitable for 3 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm complete all as specified and directed (Excavation and earth work shall be measured and paid seperately)
S & F in repair Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and ccessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed (Excavation and earth work shall be measured and paid seperately)
Dismantling of unserviceable broken LT steel pole/Strut any size including demolition of foundation as required and making good disturbed surface complete all as directed. (Note : Earth work wherever invloved shall be measured and paid separately)
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including one coat of aluminium paint over a coat of red oxide zinc chrome primer and providing 03 Nos band/strap with black/yellow colour paint 300mm apart from the plinth block, numbering of pole painting embedded portion of pole with one coat of black bitumenous paint complete all as specified and directed. (Note : Excavation and Earth work shall be measured and paid separately)
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
M & L for Preparation of old rusted steel surfaces of LT swaged pole of any length with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer upto 1.2m height (0.30m black and 0.30m yelow colour in steps upto 1.2m) above the planting depth/PCC coping and with tow coats of aluminium paint over a coat of red oxide zinc chrome primer beyond 1.2m height including MS cross arms, MS clamp, cable protection pipe etc to give even shade and re-numbering of poles complete all as specified and as directed by the Engr-in-Charge.
M & L for Repair/ Maint, Servicing of Diesel engine generating set of capacity 30 KVA of Make:- Kirloskar, 1500 RPM, Air cooled/Water cooled consisting of the following works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE : (a) Replacement of Consumable Items such as Distilled Water, Lube Oil, Grease etc are deemed to be included in the unit quoted rate. (b) All Other Spare Parts (Quantitites mentioned under supply only items here-in-after are Provisional only) and will be Measured & Paid seperately as 'Supply only' under appropriate Items. Labour element for the same shall deemed to be included in the unite quoted rate)
All as per serial item No. 137 above but for 62.5 KVA DG set complete ditto
Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed.
Supply only Bearing for cooling fan and fan belt (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed.
Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed.
Supply only Cooling fan (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed.
Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed.
Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed.
Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 62.5 KVA complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 62.5 KVA complete all as specified and as directed.
Supply only Bearing for cooling fan and fan belt (as per existing/ as approved) suitable for DG Set 62.5 KVA complete all as specified and as directed.
Supply only Controler Model No. KG934/GC1202 (as per existing/ as approved) suitable for DG Set 62.5 KVA complete all as specified and as directed.
Supply only Cooling fan (as per existing/ as approved) suitable for DG Set 62.5 KVA complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 62.5 KVA complete all as specified and as directed.
Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 62.5 KVA complete all as specified and as directed.
Supply only Fuel pipe (as per existing/ as approved) suitable for DG Set 62.5 KVA complete all as specified and as directed.
Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 62.5 KVA complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA complete all as specified and as directed.
Dismantling the alternator of 30 to 62.5 KVA DG Set from its position after disconnecting all electric connections with help of chain pulley, removing the bearing with the help of bearing puller and shifting the alternator to authorised workshop for repair and servicing complete checking of connections, terminals, lugs, tightening of connections, replacement of bushes, making good copper coil winding if burnt complete and refixing again its own position and proper alingment complete all directed by the Engr-in-Charge. (Note: (a) Winding materials of copper coil with insulation materials shall be measured and paid seperately as Supply only. Labour element for re-winding shall deemed to be included in the unit quoted rate (b) Minor spare requireded for smooth functioning of alternator shall be provided by the contractor without any extra cost to the Govt)
Supply only Super Enamel Copper Winding Wires with Proper Guage Rewinding of Alternator/Armature etc Coils of any Capacity with Double Paper covering, conforming to IS:7404 (Part-I) : 1991 (as per existing Size, Turns and Insulation Class) including All Insulation Materials, Gasket, etc., suitable for 415 Volt Alternator complete all as specified and as directed.
S & F in repair heavy duty synthetic insulation mat of size 2mx1m/2.5mm thick conforming to IS:15652-2006 suitable for 1100 Volts, ISI marked complete all specification and directed.
Disconnecting & Dismounting of Self Starter, 12 Volts from the Engine of DG Set 25 KVA to 30 KVA, Transporting to nearest Authorised Workshop for Repairing, Replacement of Unservicable Parts, Servicing Complete, Transporting the same from Workshop to Site of Work and Re-fixing with DG Set, Testing, complete all as specified and as directed. (Note: Minor spare requireded for smooth functioning of starter shall be provided by the contractor without any extra cost to the Govt)
S & F in repair Battery 12 Volt, 120 AH (as approved) and Providing all Electrical Connection complete all as specified and as directed. (MAKE : EXIDE XPRESS/LUMINOUS/AMRON)
S & F in repair Oil Safety Control (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up complete all as specified and as directed.
S & F in repair Solenoid Switch Assembly (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up complete all as specified and as directed.
S & F in repair Water Safety Control (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up complete all as specified and as directed.
S & F in repair Water Temperature Gauge (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting upcomplete all as specified and as directed.
S & F in repair Toggle Switch 3-way, Double Pole (as per existing/ as approved) and connected complete all as specified and as directed.
Supply & Filling Coolant for Radiators as approved complete all as specified and as directed. (MAKE : KIRLOSKAR or equivalent Make as approved by GE)
Supply & Filling Engine Oil 20 W/ 40 Grade as approved, complete all as specified and as directed. (MAKE : CASTROL CRB PLUS or equivalent Make as approved by GE)
M & L for Cleaning of Radiator of any Capacity after Opening all Nuts, Bolts, etc. by dismounting, Re-mounting after Cleaning with Chemical and Tightening of Nuts, Bolts, etc. including Straightening of Radiator Fins with suitable Tools, complete all as specified and as directed.
M & L for Repairing & Cleaning of Diesel Tank with suitable Materials after disconnecting Fuel Line, Opening of all Nuts, Bolts, etc., Re-fixing the same after satisfactory Repairing including necessary Welding (if required), etc., complete all as specified and as directed.
M & L for Disconnecting all Electrical Cable Connection from the Dynamo Assembly and Taking down the Dynamo Assembly for Carry out Repairs and Complete Overhauling the System including Replacing the Unserviceable Parts like Carbon Bushes, Bearings, Armature, Burnt out coils, etc., Re-assambling & Re-fixing the Dynamo Assembly to Original Position and re-connecting all Electrical Cable Connections & Testing for DG Set 25 KVA to 50 KVA of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed.
S & F in repair MCCB 415 Volt 16 KA, 4 Pole, 50 Amps Capacity, Fixed thermal & magnetic release complete all as specified and as directed . (Make:Havell's Cat No. IHLGNF0050 or equivelant of make as per List of Manufacturer's)
S & F in repair MCCB 415 Volt 16 KA, 4 Pole, 63 Amps Capacity, fixed thermal and fixed magnetic release complete all as specified and as directed . (Make: Havell's Cat No. IHLGNF0063 or equivelant of make as per List of Manufacturer's)
S & F in repair MCCB 415 Volt 16 KA, 4 Pole, 100 Amps Capacity, fixed thermal and fixed magnetic release complete all as specified and as directed . (Make: Havell's Cat No. IHLGNF0100# or equivelant of make as per List of Manufacturer's)
S & F in repair on load Change over switch, front operated, open execution, general purpose with side handle, current rating 100Amps, 4 pole, 415 V, 50 Hz complete all as specified and directed. (Make: L & T Cat No. CO11000OOOO or equivelant approved make as per list of manufacturer)
S & F in repair on load Change over switch, front operated, open execution, general purpose with side handle, current rating 125Amps, 4 pole, 415 V, 50 Hz complete all as specified and directed. (Make: L & T Cat No. CO11250OOOO or equivelant approved make as per list of manufacturer)
S & F in repair on load Change over switch, with sheet metal enclosure, current rating 40 Amps, 4 pole, 415 V, 50 Hz complete all as specified and directed. (Make:Havell's Cat No. IHCNFE0040 or equivelant approved make as per list of manufacturer)
S & F in repair on load Change over switch, with sheet metal enclosure, current rating 63 Amps, 4 pole, 415 V, 50 Hz complete all as specified and directed. (Make:Havell's Cat No. IHCNFE0063 or equivelant approved make as per list of manufacturer)
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
Materials and labour for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT, 25 x 20 cm size including dismantling of old one complete all as specified and directed.
S & F in repair expulsion fuse, single pole suitable for 11000 Volts of capacity above 25 Amps upto 50 Amps complete all as specified and directed.
S & F in repair Switch Air Break Gang operated, Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level,including porcelain insulator and steel channel frame GI operating rod 25mm dia of suitable length with operating machenism worked from ground level vertially or horzontally operated as per the site requirement including locking arrangement for operating handle complete suitable for for current rating upto 400 amps, 11 KV working pressure with 15 insulators complete all as specified and directed.
S & F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed (Excavation and earth work shall be measured and paid seperately)
S & F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed (Excavation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 150 Sqmm, 3 Core including taking up/down existing unserviceable cable complete all as specified and directed
M & L for loose filling with broken stone or boulders of gauge 40 to 80 mm in soakage well complete all as specified and directed.
S & F in repair switch disconnector fuse (panel mounting cubicle type), bolted type of rating 100 Amps, 50 Hz, 415V, four pole with 4 HRC fuses in sheet steel enclosure with side handle operated conforming to IS/IEC-60947, Part-I & 3 complete all as specified and directed. (Make : Havell's Cat No. IHCSFE0100 or equivlant model as per list manufacturer's).
M & L for dehydration and filtration of existing transformer oil and filling with fresh transformer oil for transformer upto 250 KVA at different locations with filtration machine and heating system to get the minimum di-electric strength of oil 40 KV at gap of 4mm and conforming to IS-335:1993 including removal of water contents, testing of samples taken before and after the filtration without disturbing the power supply system and re-filling/topping up/ replacement of unserviceable transformer oil complete all as specified and directed.(Note: (i) Dehydration machine shall be brought at site by the contractor and dehydration and filtration shall be carried out at site when transformer on load. Acidity and di-electric strength of transformer will be tested at site in presence of Engr-in-Charge. (ii) Transformer oil for filling/topping up shall be measured and paid seperately as supply only)
Supply only Transformer oil conforming to IS-33593 (4th Version) suitable for transformer/Voltage stabilizer etc complete all as specified and directed.
M & L for Disconnecting, taking down distribution transformer outdoor type, 11 KV/415 Volts having capacity 100 KVA to 315 KVA, transportation to workshop for repairs including opening of transformer cover, draining out of oil, de-tanking of core and coil assembly, cleaning, washing of dust and dirt from all parts including core, tank and cooling tubes, radiator etc, joint inspection for estimate, replacement of defective parts, assembly, stage inspection, re-tanking, reassembling the complete transformer after repair oil filtration/dehydration, fill dehydrated oil and fresh oil and testing the repaired transformer for all the routine tests as per IS-2026 (Part-I), 2011 with latest amendments complete all as directed by the Engr-in-Charge. NOTE : (a) Transformer oil shall be drain out by the contractor in suitable capacity mild steel drums to be arranged by the conractor at his own cost. The said drain out transformer oil shall be refilled in the transformer duly dehydrated after repair and the cost thereof shall be measured and paid seperately under respective item. (b) Rewinding of both HT & LT coil shall be measured and paid seperately. (c) Transportation charges for transformer from site of work to workshop and back after repair shall demmed to be included in the unit quoted rate. (d) Spare parts excluding nuts, bolts, washer etc shall be measured and paid seperately as supply only under respective items (e) The transformer shall be repaired in reputed workshop as directed by the Engr-in-Charge. (f) Testing of transformer after repair shall be carried out as per IS-2026 (Part-I) 2011 and the cost of testing shall deemed to be included in the unit quoted rate. (g) The IR value of the dried winding before inserting the core in the shell shall be measured and recorded. (h) Topping up of fresh transformer oil shall be measured and paid seperately as supply only)
Supply only Cast iron wheel for transformer of suitable size as per the existing one including nuts, bolts, split pins etc and welding as required complete all as specified and directed.
Supply only Breather assembly complete with silica gel suitable for any model of transformer of rating 100 to 630 KVA to air column of conseravator tank complete all as specified and directed.
Supply only Blue colour silica Gel of good quality for transformer complete all as specified and directed.
Supply only HT Bush suitable for any model/capacity of transformer inddor/outdoor of rating 100 to 630 KVA complete all as specified and directed.
Supply only LT Bush suitable for any model/capacity of transformer inddor/outdoor of rating 100 to 630 KVA complete all as specified and directed.
Supply only Arc Horn rod made of aluminium suitable for any model/capacity of transformer inddor/outdoor of rating 100 to 630 KVA complete all as specified and directed.
Supply only Temperature Gauge with GI nipple etc including testing suitable for any model/capacity of transformer inddor/outdoor of rating 100 to 630 KVA complete all as specified and directed.
M & L Earthing complete with copper earth plate electrode 600 mm x 600mm x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with copper earth strip of size 20x3mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
Taking up 100 mm bore cast iron/DI pipes (including all fittings) with spigot and socket end and lead joints including burning out lead joints and recovering lead complete and keeping serviceable pipes in safe custody for re-use in the work and removing remaining pipes with fittings from site of work complete all as specified and directed by the Engineer-in-Charge.
Taking up 80 mm bore cast iron/DI pipes (including all fittings) with spigot and socket end and lead joints including burning out lead joints and recovering lead complete and keeping serviceable pipes in safe custody for re-use in the work and removing remaining pipes with fittings from site of work complete all as specified and directed by the Engineer-in-Charge.
Taking up 50 mm bore cast iron/DI pipes (including all fittings) with spigot and socket end and lead joints including burning out lead joints and recovering lead complete and keeping serviceable pipes in safe custody for re-use in the work and removing remaining pipes with fittings from site of work complete all as specified and directed by the Engineer-in-Charge.
Supply, laying, connection and testing 100mm bore, Steel water tubing, galvanised, medium grade with all fittings and jointing materials, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately)
Supply, laying, connection and testing 80mm bore, Steel water tubing, galvanised, medium grade with all fittings and jointing materials, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately)
Supply, laying, connection and testing 50mm bore, Steel water tubing, galvanised, medium grade with all fittings and jointing materials, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately)
Supply, laying, connection and testing in repair, 25mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
Supply, laying, connection and testing in repair, 32mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
Supply, laying, connection and testing in repair, 50mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
Supply, laying, connection and testing in repair, 63mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
S & F in repair 25 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
S & F in repair 32 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
S & F in repair 50 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
S & F in repair 63 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
S & F 65mm bore, cast iron butter fly valve both end flanged, class PN 1.6 conforming to relevant IS lever operated including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket including taking out existing one complete all as specified and directed.
S & F 80mm bore, cast iron sluice valve, non-rising stem type, both end flanged, class PN 1.6 conforming to IS -14846-2000 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket including taking out/down existing one complete all as specified and directed.luding taking out existing one complete all as specified and directed.
S & F 100mm bore, cast iron sluice valve, non-rising stem type, both end flanged, class PN 1.6 conforming to IS -14846-2000 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket including taking out/down existing one complete all as specified and directed.luding taking out existing one complete all as specified and directed.
S & F 150mm bore, cast iron sluice valve, non-rising stem type, both end flanged, class PN 1.6 conforming to IS -14846-2000 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket including taking out/down existing one complete all as specified and directed.
M & L for construction of brick masonry valve pit of size 60 cm x 60 cm x 60 cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3.15mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation & earth work in soft/loose soil and demolition of existing one complete as specified and directed all as per relevant TD drawing. (Note : Drawing not attached with the tender document. However, the same can be seen in GE/AGE E/M office during working hours)
M & L for construction of brick masonry valve pit of size 100 cm x 100 cm x 100 cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation & earth work in soft/loose soil and demolition of existing one complete as specified and directed all as per relevant TD drawing. (Note : Drawing not attached with the tender document. However, the same can be seen in GE/AGE E/M office during working hours)
M & L for Dewatering Water from existing water sump 46800 Litre Capacity, by using Pumps, Cleaning and Removing all Mosses, Algae, Dirts, etc. from the Walls & Floor of Water sump, Removal of Dirty Water with Sludges and disposed off from the Site as directed, Rubbing Walls, Floor, Ceilling surfaces with Gunny Bag after sprinkling of Bleaching Powder and Wash thoroughly with Fresh Water including Cleaning of Outlet Pipes, Stop Valves, Gate Valves by Taking out Pipe Lines with Stop Valves, Gate Valves, etc. and all Accessories, Re-fixing the same after Cleaning including Float Valve with Float Arm to Original Position, Writing Letters "TANK CLEANED ON : DD.MM.YYYY" (i.e. Date of Cleaning), exc. 100mm but not exc. 200mm in height and 15mm in wide with White Paint complete all as specified and as directed. (NOTE :- (a) All the materials and T & P required for cleaning the sump shall deemed to be included in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.)
All as per serial item No. 221 above but 60000 Litres capacity sump complete ditto
M & L for Taking out existing defective Monoblock Pump set, 3 HP capacity, Opening strip of pump set and removing Mono block Pump set to AGE E/M Store yard, opening and checking, cleaning of pump set as required, transportation of defective Pump set to nearest workshop to carry out reparing/rewinding, dismantling pump set, taking out burnt copper windings, cleaning of slots of the motor, re-winding the same with supper enamlled copper insulated wire of suitable gauge and weight as per the existing one including necessary insulation materials, varnishing, heating, replacement of minor spares/ parts such as nuts, bolts, washer, gasket etc and repalcement of ball bearings etc with new one as per the existing one, greasing etc re-assembling the same and testing for smooth functioning after re-winding, and one coats of spray painting to external surfaces of pump complete and transporting back to worksite after repair, re-installation and providing all connection, testing in presence of Engr-in-Charge complete all as specified and diretced. (Note: Spare parts, Ball bearing etc as required shall be measured and paid seperately as supply only under relevant item)
All as per Serial item No. 2323above but for 5 HP monoblock pump set complete and ditto
All as per Serial item No. 223 above but for 10 HP monoblock pump set complete and ditto
Supply only Ball bearing suitable for 3 to 10 HP capacity motor as existing specifications complete all as directed (Make : TATA/SKF/NBC/BCH).
Supply only Cast Iron impaller CI KDS-3 suitable for 3 to 10 HP capacity motor as existing specifications complete all as directed
M & L for lifting of Submersible Pump and Motor assembly 12.5 HP capacity alongwith complete Column pipes. Submersible cable, safety rope etc from the existing Borewell by emplying chain pulley block etc, dismantling column pipes by opeining nuts, bolts, pump & motor etc, seggregating & stacking of serviceable column pipes & other materials and keep in safe custody for re-use and carry out necesssary repair works under the respective items here-in-below and Re-Lowering down of Submersible Pump and Motor assembly upto 12.5 HP capacity after repair alongwith complete Column pipes, Submersible cable, safety rope in the existing Borewell by emplying chain pulley block etc, and T & P, testing on completion complete all as specified and diretced.
M & L for removing submersible pump and motor assembly 12.5 HP capapcity to AGE E/M Store yard, Opening/dismantling and checking in presence of Engr-in-Charge to ascertain the quantum of defects and repair works involves, cleaning of cover and parts as required, transportation of defective submersible pump and motor assembly to nearest workshop for repairs, repairing and replacement of unserviceable parts and re-assembling submersible pump and motor assembly after repair and servicing and transporting repaired submersible pump motor assembly back to work site complete all as specified and diretced. (Note: (a) Spare Parts required to be replace will be measured and paid as "Supply only" under relevent items and the cost of labour element involved for replacement of parts shall demmed to be included in the unit quoted rate. (b) Any Minor repairs involved to make the submersible pump and motor assembly functional, even if not notified by the Engr-in-Charge, the same shall be carry out by the contractor without any extra cost to the Department. (c) The cost of minor spares parts/ items viz, nuts, bolts, washer, gasket etc shall deemed to be included in the unit quoted rate. (d) Rewinding of submersible motor, wherever involves will be measured and paid seperately under relevent item)
M & L for dismantling of Submersible Motor 12.5 HP capacity, taking out burnt windings, cleaning of slots of the motor and Rewinding the same with water proof super enamelled copper insulated wire of suitable guage and weight as per the existing one including necessary insulation materials, varnishing, heating, reassembling the same and testing for smooth functioning after rewinding complete all as specified and directed by the Engr-in-Charge.
S & F in repair DOL starter, 3 HP, 415 Volts, 50 Hz with outgoing and incoming cable connections and testing on full load complete all as specified and directed. (Make: Havell's Cat No.IHHDOLJA*E or equivelant as per list of manufacturer)
S & F in repair DOL starter, 5 HP, 415 Volts, 50 Hz with outgoing and incoming cable connections and testing on full load complete all as specified and directed. (Make: Havell's Cat No. IHHDOLLA*E or equivelant as per list of manufacturer)
S & F in repair DOL starter, 10 HP, 415 Volts, 50 Hz with outgoing and incoming cable connections and testing on full load complete all as specified and directed. (Make: Havell's Cat No.IHHDOLNA*E or equivelant as per list of manufacturer)
S & F in repair Fully automatic star delta starter, 12.5 HP, 415 Volts, 50 Hz with outgoing and incoming cable connections and testing on full load complete all as specified and directed. (Make: Havell's Cat No. IHHASDTA or equivelant as per list of manufacturer)
Supply only High strength calcium Hypo Chloride, 65-70% chlorine content, Calcium based granular disinfectant for water treatment chemical complete all as per the following specifications: (a) Available chlorine: Minimum 65% by mnass (b) Stability: Maximum 1/15 loss of chlorine on the basis of available chloride (c) Particle size (passing through 1.70mm IS Sieve): Minimum 99.5% by mass (d) Water insoluble matter: Maximum 6% (e) Calcium hydroxide: 4% maximum (f) Sodium chloride: 15% maximum (g) Description/Appearance: Dry free flowing and free from lumps (h) Toxic & undesirable substance: Should not induce substances beyond acceptable limit as given in IS-10500 (2012) in treatment and disinfected water (j) Packing: 20-25 Kg/ 40-45 Kg drums (Note: Make shall be as per approved makes of E-in-C. Testiting certifcate of chemical shall be submitted by the contractor before supply).
Supply only Bleaching powder for water treatment chemical complete all as specified and directed.
Supply only Alum Crystal for water treatment chemical complete all as specified and directed. (Note: Manufacturer's test certificate and original purchase vouchers for each lot of supply shall be submitted by the contractor for payment)
M & L for Preparation of old painted steel internal surfaces of Pressed steel water storage tank of any capacity at a height of 15m staging including all connected accessories like GI pipes, valves and other fittings etc by removing rust etc from the surfaces by rubbing with wire brush etc and applying two coat of black bitumenous paint (For drinking purpose) complete all as specified and directed.
M & L for Preparation of old painted steel external surfaces of Pressed steel water storage tank of any capacity at a height of 15m staging including all connected accessories like steel staging, GI pipes, valves and other fittings etc after complete removal of existing paints from the surfaces by scrapping with wire brush etc and applying two coats of aluminium paint over a coat of aluminium red oxide primer complete all as specified and directed.
Supply and filling of new life MnO2 compound including filler after taking out (unloading) the old catalyst from oxidation chamber with proper care complete and cleaning of pipes, butterfly valve etc of any capacity, flow, height after opening the manhole cover, disconnection and including removing the waste materials upto 50m away from site of, spreading, levelling complete all as specified and directed by the Engr-in-Charge.
Supply and filling of new filter media of gravel of size 3/4"x1/2", 1/2" x 1/4", 1/4"x 1/8", 1/8'x 1/6"(as approved) free from any foreign materials and washed with clean water before filling including taking out (unloading) of old rusted and muddy filter media from iron removal filter vassel with propper care complete and cleaning of pipe, butterfly valve etc of any capacity, flow, height after opening the manhole cover, disconnection and including removing the waste materials upto 50m away from site of, spreading, levelling complete all as specified and directed by the Engr-in-Charge.
S & F in repair PVC double nut type strainer as per the site requirement complete all as specified and directed by the Engr-in-Charge.
S & F in repair of water pressure gauge with fittings as per the site requirement with isolating valve and siphon complete all as directed by Engineer-in-Charge.
S & F in repair injection check valve (3/8") for chemical dozing pump complete all as specified and as directed.
S & F in repair coil for chemical dozing pump, 230 Volts, 50 Hz complete all as specified and as directed.
Supply only Chlorine Test Kit with colour ample complete with all testing fitments and OT solution in rexene finish box complete all as specified and as directed.
Supply only OT solution for chlorine test (500ml) complete all as specified and as directed.
SATYA CHANGMAI (BID ID -3408862)
M/S SINGH TRADERS (BID ID -3409520)
ms singh construction (BID ID -3408998)
Shri Debajyoti Das (BID ID -3409120)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .