| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-Finance | ₹48.2 L | L1 | Accepted-Finance SUCCESFUL-L1 |
| 2 | L2₹48.7 LRejected-Finance | ₹48.7 L | L2 | Rejected-Finance UNSUCCESFUL-L2 |
| 3 | L3₹48.7 LRejected-Finance DAKHINSOLE P O CHAKSHYAMPUR DIST BANKURA | BANKURA | BANKURA | WEST BENGAL | ₹48.7 L | L3 | Rejected-Finance UNSUCCESFUL-L3 |
| 4 | L4₹48.7 LRejected-Finance 69 1A DESHBANDHU ROAD EAST KOLKATA 700035 | KOLKATA | KOLKATA | WEST BENGAL | 700035 | ₹48.7 L | L4 | Rejected-Finance UNSUCCESFUL-L4 |
| 5 | L5₹49.2 LRejected-Finance VILL P O BHADUL DIST BANKURA PIN 722155 | BHADUL | BANKURA | WEST BENGAL | 722155 | ₹49.2 L | L5 | Rejected-Finance UNSUCCESFUL-L5 |
Tender Value
₹48.7 L
EMD Value
₹97,483
Closing Date
16 Mar 2026, 12:00 pmClosed
Executive Engineer, Bankura Division, PWD
Office of the Executive Engineer Bankura Division PWD Kenduadihi Bankura
Repair and renovation work including replacement of damaged asbsestos roof sheet of Lecture theatre - 1 and Lecture theatre - 2 at ground floor of Administrative building at Lokepur campus of Bankura Sammilani Medical College under Bankura Division,
2026_WBPWD_1013798_8
WBPWD/EE/BANKURA DIVISION/NIT- 19/2025-2026
Open Tender
CIVIL WORKS
90 days
Bankura
Please refer Tender documents.
4 documents required · 4 mandatory
₹97,483
27 May 2026
24 Feb 2026
18 Mar 2026
2 Mar 2026
16 Mar 2026
2 Mar 2026
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75 m as directed.
Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damage will be paid separately). (b) Above area 2.5 Sq.m
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety. In Gound Floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (b) 20 mm thick plaster. In Ground floor.
(i) With 1:6 cement mortar (c) 15 mm thick plaster. In Ground floor.
In First floor.
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency]. b) With Chawk Dungri. (iii) Area of each tile exceeding 0.6 sq.m but not excedding 1 sq.m. In Ground floor.
Supplying fitting and fixing 15 to 18 mm thick Marble slab/Tile in riser of step or skirting (upto 300 mm ht) over 15mm (avg) thick base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/ Sq.m at back side of marble and jointed with white cement slurry @ 2.2 kg/ Sq.m with necessary pigments including grinding and Granite Polishing. [White cement and Pigment to be supplied by the Agency] b) With Chawk Dungri. (ii) Area of each tile exceeding 0.3sq.m. but not exceeding 0.6 sq.m. In Ground floor.
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (e) Sal : Malayasian. In Ground Floor.
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction. (Cost of concrete will be paid separately) (b) 40 mm x 6 mm, 200 mm length.
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made). (iv) 25 mm thick shutters with 12mm thick panel of size 30 to 45 cm. (b) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak. In Ground Floor.
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (vii) 100 mm. X 58 mm. X 1.90 mm.
Iron socket bolt of approved quality fitted and fixed complete.. (b) 100 mm long x 10 mm dia bolt.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod). (i) 75 mm grip x 10 mm dia rod.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For roof truss works a) Span up to 12 Mtr.
a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. In Ground floor.
Supplying fitting and fixing I.R.C. fabric mesh with covering battens including cost of screws etc complete (excluding the cost of battens). (i) 25 mm x 25 mm x 2.7 mm x 2.7 mm. In Ground floor.
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall). (ii) 4 mm thick
Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.and stacking the material at site as directed.
Supplying, fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45 mm BMT (Base Metal thickness) (0.50 mm TCT (Total Coated Thickness excluding paint), G550 (min 550 yield strength), of Zincalume metallic coating (IS15965) with high solar Reflectance Index (SRI) value for better colling as per thermatech technology, 1000-1015 mm effective cover width with five major corrugation, 28 mm high rib spaced at 203 mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg. The coated, hex head,self-drilling screw as per IS 3566-2002 class 3 fastener, The base steel shall be coated with Zinc-Aluminium alloy Zincalume (AZ150) (ie 55% Al, 43.4%, Zinc, 1.6% si ) Minimum of 150g/m2 coating total on both sides, pre-painted with colour bond XRW (xterior roofing, walling ) paint system of 35 micron Super Durable Polyester paint (SDP) with stable inorganing pigment with no lead contents confirming ISI5965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheet at regular interval confirming genunity of the material. (i) In Roof:- a) 0.5 mm thick Sheet.
A) Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at regular interval of 600 mm to form a modular grid of 1200mm X 600mm. False Ceiling (with 6 mm thick Fibre Cement Standard Ceiling Board and E-Grid T-2430).
Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge).
Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge).
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc..
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
(b) On steel or other metal surface With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat (ii) Solvent based interior grade Acrylic Primer
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats. In Ground Floor.
In First Floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two Coat). a) Normal Acrylic Emulsion. In Ground Floor.
In First Floor
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in ntermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
2911-ii.pdf
Tender Documents • 0.58 MB
BOQ_2490531.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid