| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹16.8 L+₹4.0 L (31.2%)Rejected-Finance | L2 | Rejected-Finance Quoted high rates | |
| 3 | L3₹17.8 L+₹5.0 L (39.0%)Rejected-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L3 | Rejected-Finance Quoted high rates |
Tender Value
₹18.4 L
EMD Value
₹36,760
Closing Date
13 May 2024, 6:00 pmClosed
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner Bikaner Mil Stn
Repair/maint of mechanical laundry, fire fight equipment, lift and connected works under GE (A) Suratgarh
2024_MES_650123_1
CA No CWE BKN-Token No. 01/2024-2025
Open Tender
Miscellaneous Works
Item Rate
180 days
GE A SURATGARH
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (A) Suratgarh
₹36,760
Yes
5 Jun 2024
15 Apr 2024
15 May 2024
15 Apr 2024
13 May 2024
29 Apr 2024
15 Apr 2024 - 20 Apr 2024
Amount
Inspection & checking of Mechanical laundry steam boiler of capacity 200 Kg/hr and finding of fault by checking control devices, claibration of PLC, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including descaling the boiler and making connections complete all as specified and as directed.
Inspection and checking of washer Extractor of Capacity 30 Kgs make Ramson and findng of fault by checking control devices, claibration of PLC, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc. removing the defects and refixing in its original position including making connections complete all as specified and directed.
Inspection & checking of Drying tumbler of capacity 30/50 Kg (make Febcare/Ramson) and finding of fault by checking control devices, claibration of PLC, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including making connections complete all as specified and as directed.
Inspection & checking of Flat work ironer front feed and rear return type and finding of fault by checking control devices, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including making connections complete all as specified and as directed.
Inspection & checking of flat body press machine and finding of fault by checking control devices, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including making connections complete all as specified and as directed.
Inspection & checking of air compressor and finding of fault by checking control devices, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including making connections complete all as specified and as directed. Notes for serial item No 1.00 to 6.00 : (i) All spare parts for repair shall be procured from manufacturer’s authorised dealer only. (ii) All tools, testing instruments shall be arranged by the contractor including necessary transport. (iii) The fixing/labour element for spare parts required to be replaced shall deemed to be included in quoted rates of this item and spare parts shall be measured and paid for separately as “Supply only” under respective items of this Schedule. (iv) Testing of the boiler by authorised in presence of GE & Engineer-in-Charge & certificate to be submitted before making the payment.
Supply only SS seal bush
Supply only PLC front Panel (ST2002)
Supply only housing ring
Supply only Anabond
Supply only Flexible Pipe (Size: 1/2" X 1mtr.).
Supply only Temperature Controller for boiler and washing machine.
Supply only Probe for Temperature Controller for boiler
Supply only Steam Trap 1/2" for boiler
Supply only bearing RVWE30 Big (bearing NU213).
Supply only bearing RVWE30 Small (bearing 6311).
Supply only mechanical seal RVWE30 (shaft seal 85mm jhon crane).
Supply only oil seal RVWE30.
Supply only Emergency switch red.
Supply only indicator red.
Supply only transformer 415/220 V AC tumble drier.
Supply only pump cylinder (pump bottle).
Supply only NRV as per sample or required at site for boiler.
Supply only data cable
Supply only Pneumatic Valve for (Y - Type, Size : 2")
Supply only Globe gate Valve 1".
Supply only Drain Valve for 30 KG.
Supply only Air solenoid valve.
Supply only Push Button.
S&F in replacement MS Pipe, heavy grade, 20mm bore, ISI marked, including all fittings complete all as specified and as directed.
S&F in replacement MS Pipe, heavy grade, 25mm bore, ISI marked, including all fittings complete all as specified and as directed.
Inspection/checking and calibration of weighing machine of capacity 30 Ton by checking/ repairing all the connections and cleaning of load beam cell, etc to make the machine serviceable and to measure actual weight by replacing defective parts, if any, complete all as specified and directed. Notes : The Cost of parts if repalced deemed to be included in item rate only.
(Contd serial item No. 33 here-in-before) (h) Any rescue/breakdown shall be attended and experience towards repair/replacement / manpower T&P required shall be deemed to be included in unit rates quoted by the tenderer. (j) Each lift shall be got inspected by the Govt Lift Inspector once in a contract period for the worthiness certificate in respect to safety etc. and cost for which shall also be accounted in unit rates quoted by the tenderer. (k) In the event of failure of lift, repair action should be attended within 03 hours from registering the complaint. In case, contractor fails to repair the defects within the stipulated time, a penal recovery shall be effected as mentioned here-in-after in Particular Specification Section-II. (l) Cabin Fan, emergency light inside the cage and exhaust fan inside the machine room for all lift shall be functional round the clock otherwise penal recovery shall be effected @ Rs. 60/- per day per lift after 24 hours for the inconvenience for above mentioned any item from contractor’s payment. (m) The contractor shall stock sufficient parts/ major assembly to ensure putting the lift in working condition in shortest possible time to avoid inconvenience to users. Make: as per existing make and model/type matching with existing Lift.
Supply only sensor with RX / TX with controller power supply and wiring.
Supply only C.O.P push button suitable for passenger lift.
Supply only Landing car button suitable for passenger lift.
Supply only Car Gate Switch suitable for passenger lift.
Supply only Door operator drive controller power unit.
Supply only Break oil.
Supply only Variable Voltage Variable Frequency (VVVF) drive 12.5 HP 380/480 Volts AC 50 Hz, preprogrammed as per existing Lift Make: Schneider.
Supply only Rectifier card 110 V - 24 V output.
Supply only SMPS Card.
Supply only Main control Card.
Supply only Transformer Card, AC 110 Voltage.
Supply only Relay Board.
Supply only Timer card.
Supply only Gate lock switch.
Supply only Gate lock spring.
Supply only MOM Card
Supply only Control Transformer
Supply only track roller
Supply only track incentary
Supply only door shoe
Supply only door belt / door rope
Supply only Infra red sensor
Supply only door coupler assembly
Supply only final limit
Supply only emergency alarm
Supply only break liner
Supply only Main Hoist Rope of traction steel, atleast 19 strands wound about a core centre, circumference of rope 13 mm, factor of safety as given in relevant IS code with end nut lock complete all as specified and directed.
Supply only divertor pulley
S&F in replacement of LED down light fitting, 12 Watt recess mounted (for ceiling cutout dia150 mm), white 6000k in pressure die cast aluminium luminaire in powder coated white finish in round profile with seperate electronic driver with fixing frame and all eletrical connection complete all as specified and directed.
M&L for rewinding of motor for cabin fan 60 Watt single phase with replacement of unserviceable bearing, connector, pvc cable, etc complete all as specified and directed.
M&L for rewinding of motor 10 / 12.5 HP three phase with replacement of unserviceable bearing, connector, pvc cable, terminal plate etc. complete all as specified and directed.
Repair/overhauling to ARD system of lift by replacement to unserviceable control card, dry cell battery etc to make ARD serviceable and testing complete all as specified and directed. Note: Dry cell battery shall be measured and paid for seperately.
Supply only battery dry cell type 12 volts, 7 AH of elevator Automatic Rescue Device (ARD) with electrical connection complete all as specified and directed.
Supply only battery dry cell type 12 volts, 12 AH of elevator Automatic Rescue Device (ARD) with electrical connection complete all as specified and directed.
M&L for repair to Variable Voltage Variable Frequency (VVVF) drive, 10/12.5/15HP, including repairing/ replacement of main control cord, IGBT card, diode, capacitor, rectifier, testing & re-fixing, software installation complete all as specified and directed.
S&F in replacement 01 HP motor Pump for Boiler having 600 PSI, 12 LPM (litre per minute) function capacity having 950 RPM as per ISO 9001:2008 CO as revised time to time complete all as specified and directed.
M&L for preparation of old surfaces of Boiler chimeny for painting with two coats of aluminium anti corrosive paint of first quality after one coat of red oxide complete all as specified and as directed.
S&F in repair transformar PRI 230 Volt 1,2A, 50 HZ for Boiler complete all as specified and as directed.
S&F in repair Mother Board (Card) for Washer Extractor of Cap 30 Kg complete all as specified and as directed.
M&L for Trumbler Drier machine, findng of fault by checking control devices & removing the defects and refixing in its original position including making functional complete all as specified and directed.
Repair to centrifugal pump capacity 20 HP by disconnecting from motor and pipe, strip opening the pump and replacement of unserviceable parts such as impeller, bushes, shaft sleeves, ball bearing, nut bolts, gland plate, gasket, water hose pipe etc and lathe work/turning, grinding etc on shaft and shaft key way as required including greasing/oiling and re-assembling at the same location with proper alignment with motor and testing complete all as specified and directed. Note :- (i) Major items like impeller, bearing, bush, gland plate, tyre coupling, coupling assembly shall be measured and paid for separately under respective items of BOQ as “Supply only”. (ii) Cost for transportaion to workshop and carry back to site after repair is inlcuded in the unit rate of item nothing extra shall be paid on this acount.
Supply only CI impeller suitable for centrifugal Pump set capacity 20 HP complete all as specified and directed.
Supply only Stainless steel Bush suitable for centrifugal Pump capacity 20 HP complete all as specified and directed.
Supply only Gland plate suitable for centrifugal Pump capacity 20 HP complete all as specified and directed.
S&F in replacement Rubber tyre for coupling suitable for centrifugal Pump set capacity 20 HP motor including replacement of unserviceable nut, bolt and washer complete all as specified and directed.
S&F in replacement Ball bearing suitable for centrifugal Pump / motor capacity 20 HP with proper T&P / bearing puller and lathe work on shaft of pump / motor as required and testing complete complete all as specified and directed. Make : NBC/SKF/TATA
M&L for repair to foot valve of 100mm/ 150mm size by disconnecting from pipe line and replacement of cast iron door plate assembly, hinge pin / disc guide pin, rubber door face and rubber gasket and fixing on same location and testing complete all as specified and directed.
S&F in replacement single outlet hydrant valve size 63mm instantaneous, gun metal body, ISI marked with flanged inlet, CI hand operating wheel and end caps with chain complete all as specified and directed. Make :- Kartar / Leader
S&F in replacement double outlet fire hydrant valve size 63mm instantaneous, gun metal body, ISI marked with flanged inlet, CI hand operating wheel and end caps with chain complete all as specified and directed. Make :- Kartar / Leader
S&F in replacement of fire hose Box, double door with 4 mm thick glass, for storing two nos of 15 mtr hoses and one nozzle, made in 18 SWG CRCA sheet, weather proof, finished with red colour paint fixed on wall complete all as specified and directed.
S&F in replacement of Fire Hose, size 63 mm, ISI marked, 15 mtr long, with male and female coupling complete and conneted to existing system complete all as specified and directed.
S&F in replacement of hose reel drum with stainless stell side body, swinging type, ISI marked, including seamless hose reel tube 30 Mtr long, size 20 mm dia. with nozzle and ball valve, fixed on wall with wall bracket and inlet connection complete complete all as specified and directed.
S&F in replacement of 65mm instantaneous male pressure test cap gauge, copper alloy with bleeder valve complete all as specified and directed.
S&F in replacement of fire hydrant branch nozzle, gun metal, 63 mm, complete all as specified and directed.
S&F in replacement of 150mm dia butterfly valve complete all as specified and directed.
S&F in replacement of 100mm dia butterfly valve complete all as specified and directed.
S&F in replacement Cast iron non return valve / reflux valve with rubber seat flanged type with by pass arrangement suitable for 150mm bore pipe, ISI marked, class PN-1.6 conforming to IS- 5312/2004 with stainless steel spindle, CI gate with brass nuts, bolts, washers and jointing with necessary ruber gasket etc complete all as specified and directed.
Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 10 Sqmm, 3 core complete all as specified & as directed.
M&L for disconnecting all electrical and pipe line connection connected to Diesel Engine of capacity 69 bhp Make : Kirloskar Model Type: RB-44, 1500 RPM, unit carefully for finding out the defects and servicing including replcement of the unserviceable parts, fuel filter, air filter, oil filter, Fan belt, Hose pipe set, engine oil, coolent, bearings complete and refixing the same in original position couple with pumpset and connecting the pipe line testing complete all as directed by Engr-in-charge. Note: The rate inculdes the replacement of air filter, oil filter, fuel filter, fan belt, hose pipe, engine oil, coolent, bearing etc. Nothing extra shall be paid on this account.
S&F in replacement of lead acid battery, 12 Volts, 180 AH, low maintenance with initially full charged alongwith electrolyte and testing complete all as specified & as directed. Make : Amaron/Exide/Luminous
S&F in replacement battery lead connection made out of PVC insulated single core 25 sqmm size 1.5 mtr long inlcuding one end with copper lug and other end with a brass terminal with nut bolt and washer complete all as specified & as directed.
S&F in replacement of industrial pressure switch for water flow system including control wiring complete all as specified & as directed Make: Indfos
S&F in replacement of water pressure gauge stenless steel body for (0-220 psi) complete all as specified & as directed.
M&L for checking all electrical and control wiring for fire fighting electrical panel for smooth functioning and automatic start and stop of fire fighting system and rewiring of control system of presure switches, contactor of motor for c/f pump/ jockey pump and diesel engine and testing as per OEM complete all as specified & as directed. Notes: (i) The unit rate includes the replacement of minor parts like control copper wiring, lugs/ thimbles/ nut bolts, washer, dressing etc. Nothing extra shall be paid on this account. (ii) Replacement of major parts like, MCCBs, contactors, relay, timer, pressure switches, voltmeter, ammeter etc will be measured and paid seperately.
S&F in replacement of power contactor, AC3 rating, 200 Amps, 3 Pole, AC control with Auxiliary contacts NO/NC, adblock complete with all control wiring and including any alteration to existing panel for fixing of the contactors complete all as specified & as directed. Make: Schneider/ L&T/ Siemens
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 160 Amps complete all as specified & as directed.
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 120 Amps complete all as specified & as directed.
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 95 Amps complete all as specified & as directed.
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 65 Amps complete all as specified & as directed.
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 40 Amps complete all as specified & as directed.
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 32 Amps complete all as specified & as directed.
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 9 Amps complete all as specified and directed;
Supply and fixing in replacement of landing header with glass door for lift at 184 MH complete all as specified & as directed.
Supply and fixing in replacement of travelling cable and other wiring of lift at 184 MH complete all as specified & as directed.
S&F in replacement of thermal over load relay adjustment range 66-110 amps with all electrical wiring complete all as specified & as directed.
All as per serial item No 108.00 here-in-before but adjustment range 48-65 Amps complete all as specified and directed.
All as per serial item No 108.00 here-in-before but adjustment range 17-25/ 23-32 / 30-40 / 37-50 Amps complete all as specified and directed.
All as per serial item No 108.00 here-in-before but adjustment range 12-18 Amps complete all as specified and directed.
S&F in replacement of star delta timer 3 sec - 120 sec, 415 Volts with control wiring complete all as specified & as directed by Engineer-in-charge.
S&F In replacement of single phase preventor (SPP) with auto reset, 415 Volts AC, with control wiring complete all as specified & as directed.
Taking out electric motor, 415 Volts, AC, capacity upto 20 HP by disconnecting from exisitng pumpset including electrical connection and taking out from foundation and dismantling the same for servicing and replacement of unserviceable parts such as ball bearing, rewinding, teminal plate with coper, copper lugs/ washer, nut bolts etc and other connected minor parts and including any welding, grinding and finishing work on rotor and reassembling, re-installing at same location and proper alignment and all electrical connection and testing complete all as specified & as directed. Note:- (i) Transportation of motor to civil workshop, if required, is included in the unit rate of items nothing extra shall be paid on this account.
M&L for taking out defective non-clog sewage submersible pump set of capacity 7.5 HP/10 HP from sewage well with proper T&P chain pulley as required and rewinding of unserviceable motor with supper enamelled copper winding wire of existing gauge inlcuding varnish, baking, and replacement of unserviceable parts i.e. bearing, impeller, key, thrust bearing etc. and refixing of the same and testing complete all as specified & as directed.
M&L for taking out defective non-clog sewage submersible pump set of capacity 12.5 HP/15 HP from sewage well with proper T&P chain pulley as required and rewinding of unserviceable motor with supper enamelled copper winding wire of existing gauge inlcuding varnish, baking, and replacement of unserviceable parts i.e. bearing, impeller, key, thrust bearing etc. and refixing of the same and testing complete all as specified & as directed.
Supply only water seal for submersible sewage pumpset of capacity 7.5 /10 HP as per existing type complete all as specified & as directed.
Supply and fixing in replacement of SS 304 cabin for lift including dismentling of existing cabin complete all as specified & as directed.
Supply and fix in replacement of car header with glass door & door operator for lift including dismentling of existing car header and glass door complete all as specified and directed.
Supply and fix in replacement of cabin /car operating panel for lift including dismentling of existing COP complete all as specified and directed.
Supply and fix in replacement of landing operating (LOP) for lift including dismentling of existing LOP complete all as specified and directed.
Supply and fix in replacement of Automatic Rescue Device ( ARD ) 7.5 HP for lift at 184 MH complete all as specified and directed.
M&L for painting of fire fighting system (184 MH) complete inclduing piping network, hydrant, hose box and other conected items by nozzle spray with sythetic enamel weather proof good quality paint red colour or existing colour code after preparing of old surface by srcapping/rubbing and marking complete all as specified & as directed.
M&L for monthly Periodical maintenance and replacement of unserviceable alarm system/ spare parts of fire alarms cum detection systems installed at Military Hospital complete all as specified & as directed.
S&F in replacement addressable manual call point, resettable type, IP-24, ISI marked with all electrical connection and fix on wall complete all as specified & as directed.
S&F in replacement fire alarm (bell), 24 V DC, ISI marked with all electrical connection and fix on wall complete all as specified & as directed by Engineer-in-charge.
S&F in replacement of fire alarm panel, 16 Zone matching with existing panel and control system with isolate and test function with all electrical connection and testing complete all as specified & as directed.
S&F in replacement of fire alarm panel, 10 Zone matching with existing panel and control system with isolate and test function with all electrical connection and testing complete all as specified & as directed.
S&F in replacement of fire alarm panel, 8 Zone matching with existing panel and control system with isolate and test function with all electrical connection and testing complete all as specified & as directed.
S&F in replacement of fire alarm panel, 6 Zone matching with existing panel and control system with isolate and test function with all electrical connection and testing complete all as specified & as directed.
Taking down fire alarm panel 3 Zone for finding out the defects and repair work by replacement of unserviceable items as battery, swithces, display, microprocessor control card/ ICs/LED indicators etc. and other connected parts and refixing the same in original position complete and testing complete all as specified & as directed.
Taking down fire alarm panel 6 Zone for finding out the defects and repair work by replacement of unserviceable items as battery, swithces, display, microprocessor control card/ ICs/LED indicators etc. and other connected parts and refixing the same in original position complete and testing complete all as specified & as directed.
Taking down fire alarm panel 8 Zone for finding out the defects and repair work by replacement of unserviceable items as battery, swithces, display, microprocessor control card/ ICs/LED indicators etc. and other connected parts and refixing the same in original position complete and testing complete all as specified & as directed.
Taking down fire alarm panel 10 Zone for finding out the defects and repair work by replacement of unserviceable items as battery, swithces, display, microprocessor control card/ ICs/LED indicators etc. and other connected parts and refixing the same in original position complete and testing complete all as specified & as directed.
Taking down fire alarm panel 16 Zone for finding out the defects and repair work by replacement of unserviceable items as battery, swithces, display, microprocessor control card/ ICs/LED indicators etc. and other connected parts and refixing the same in original position complete and testing complete all as specified & as directed.
S&F in replacement of smoke detector as per existing make and model and testing complete all as specified & as directed.
S&F in replacement of heat detector as per existing make and model and testing complete all as specified & as directed.
S&F in replacement of optical/photoelctrical fire detector as per existing make and model and testing complete as directed by Engr-in-charge.
BHADU BUILDERS
SHIVA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .