Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹2.1 L+₹10,875 (5.51%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹2.3 L+₹32,750 (16.6%)Rejected-Finance 1ST SHAKUNTALA SADAN 04 RAMPURA BASTI LALGARH BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L3 | Rejected-Finance not being lowest | |
| 4 | L4₹2.4 L+₹42,288 (21.4%)Rejected-Finance | L4 | Rejected-Finance not being lowest |
Tender Value
₹2.8 L
EMD Value
₹5,560
Closing Date
18 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NAL
GE AF NAL
AS DESCRIBED IN BILL OF QUANTITIES
2023_MES_624684_1
GE (AF) NAL/T-53/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
GE AF NAL
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹300
GE AF NAL
₹5,560
Yes
16 Dec 2023
23 Oct 2023
20 Nov 2023
23 Oct 2023
18 Nov 2023
6 Nov 2023
23 Oct 2023 - 1 Nov 2023
Amount
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality ,5 star rating of capacity 1.5 TR complete with all fixing arrangement on wall /floor including refrirerant line from outdoor unit to indoor unit as required at site with out any extra cost complete all as specifed and as directed. Note :- (a) Quoted rates include copper suction & discharge line, electric cable from indoor unit to outdoor unit upto 3 Mtr. (b)Rates include suitable stand for fixing Outdoor unit on wall . (c) Rates include initial charging of Refrigent Gas, include testing and commissioning complete and submited two set of temp test sheets.
All as per item no 01 above but of capicity 2 TR.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specifed and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specifed and as directed.
S & F plug and socket box(Metal clade) including fixing MCB SP 20 Amp C curve type 6 KA, 240 Volts complete all as specified and directed.
S&F sub main wiring with two runs of single core 4 smm PVC insuated, unsheatehed stranded Copper FRLS coductor, 1100V drawn in concealed conduit including 4 sqmm coper stranded conductor PVC insulated 1100V FRLS earth wire connected to mian board including PVC rigid conduit medium grade pipe 20mm dia complete all as specified and diected Note :- rate for one unit includes for two number cable , one number earth wire and one unit pvc conduit
S&F sub main wiring with two single core 6 smm PVC insuated, unsheatehed stranded copper FRLS coductor, 1100V drawn in concealed conduit including 4 sqmm coper stranded conductor PVC insulated 1100V FRLS earth wire connected to mian board including PVC conduit medium grade pipe not less than 25 mm dia complete all as specified and diected (Two number cable and one number earth wire shall be measured together as one unit lenght). Note :- rate for one unit includes for two number cable , one number earth wire and one unit pvc conduit .
Supply and fixing distribution board double door, dust and vermin proof SPN 8 way with 200 Amp rated copper busbar ,neutral bar ,earth bar IP 43 protection single pole and neutral 240 volts flush into wall after necessary cutting complete all is specified and directed.
S& MCB SPN 63 Amps , C curve type 10 KA, 240 Volts complete all as specified and directed.
S&F MCB SP 40 Amps, C Curve type 10 KA breaking capacity 240 Volts complete all as specified and directed.
B.K. ROY & SONS
J.D INFRA ENGINEERING
KARNI ELECTRICAL CORRPORATION/ANKIT YADAV
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .