Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹6.7 L+₹41,166.66 (6.54%)Accepted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | L2 | Accepted-Finance ok | |
| 3 | L3₹7.3 L+₹98,972.50 (15.7%)Accepted-Finance | L3 | Accepted-Finance ok | |
| 4 | L4₹7.4 L+₹1.1 L (17.5%)Accepted-Finance | L4 | Accepted-Finance ok | |
| 5 | L5₹7.5 L+₹1.2 L (19.1%)Accepted-Finance | L5 | Accepted-Finance ok |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
25 Feb 2023, 11:05 amClosed
EE SDW IX
RITHALA STP SEC-11 ROHINI DELHI 110085
Rewiring of staff quarter type II under the division EE SDW IX Rithala
2023_DJB_236801_3
NIT No.18 (2022-23)
Open Tender
Miscellaneous Works
Works
30 days
RITHALA STP SEC-11 ROHINI DELHI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
As per NIT
₹20,000
3 Mar 2023
18 Feb 2023
25 Feb 2023
18 Feb 2023
25 Feb 2023
18 Feb 2023
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano types switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulted copper conductor single core cable etc as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulted copper conductor single core cable as earth wire in existing surface / recessed steel / PVC conduit including dismantling as required.
Supply and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections/ painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16A piano type switch, connections painting etc as required.
Wiring for circuit /Submain wiring along with earth wire with the following sizes of FRLS PVC insulted copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2x2.5sq.mm+ 1x2.5sq.mm earth wire.
2x4sq.mm+ 1x4sq.mm earth wire.
2x6sq.mm+ 1x6 sq.mm earth wire.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 3 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powered painted including earthing etc. as required 8 way double door.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB SP complete with connections, testing and commissioning etc. as required, Single pole
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DP complete with connections, testing and commissioning etc. as required, double pole
Supplying and fixing 63 A rating, 240V, isolator in the existing MCB DP complete with connections, testing and commissioning etc. as required, double pole
Supply of 35 sq mm 3.5 core LT aluminium power cable. Make:-Havells/Gloster/Universal/Grandlay/ICC/ICU/any other DJB approved make of DJB
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Upto 35 sq mm
Devraj Enterprises
Gupta Brothers
MK ENGG.CO.
HYDROCON ENGINEERS
ISHIKA ASSOCIATES
Goodwill Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .