Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹18.6 L+₹11,579.50 (0.63%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹19.0 L+₹57,143 (3.10%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹25 L
EMD Value
₹25,000
Closing Date
16 Nov 2023, 2:00 pmClosed
Superintending Engineer
EDC, AYODHYA
Increasing Capacity of Transformers at Different Places and Construction of Transformer Plinth and Fencing of Transfomer Under Electricity Distribution Division-IInd, Ayodhya
2023_MVVNL_858615_1
97 H(F)(W)/2023-24
Open Tender
Electrical Works
Item Wise
90 days
Ayodhya
AS PER TENDER SPECIFICATION
2 documents required · 2 mandatory
₹3,540
Superintending Engineer, EDC
₹25,000
20 Nov 2023
2 Nov 2023
16 Nov 2023
2 Nov 2023
16 Nov 2023
2 Nov 2023
Amount
Part - A ( Material) Following Material Supplied by the Contractor:-
11 KV X-arm Holding Clamp
F- Clamp
LT Clamp
Holding Clamp Top & Dropper Channel
Nut & Bolt
Carriage including loading,unloading & Proper stacking of following Stock materials from store/departmental store to Dump site distance 0 to 70 Kms. (distance approx)
PCC Pole 8.5 Mtr. Long
XLPE Cable 3.5x240 sqmm
AB Cable 3x50
AB Cable 3x95+1x70+1x16
ACSR Weasel Conductor
Transformer 25 KVA
Transformer 63 KVA
Transformer 250 KVA
11 KV XLPE Cable 3x185 sqmm
11 KV XLPE Cable 3x300 sqmm
11 KV Cable Jointing Kit outdoor 3x185 sqmm
11 KV Cable Jointing Kit Indoor 3x185 sqmm
11 KV Cable Jointing Kit outdoor 3x300 sqmm
11 KV Cable Jointing Kit Indoor 3x300 sqmm
Other matching Materials
Dragging of PCC Pole from dump site to pit site
Fabrication and Errection of Double Pole Support on PCC Pole Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPo Norms. (Cost of clamps borne by contractor)
Fabrication and Errection of Single Pole Support on PCC Pole Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPo Norms. (Cost of clamps borne by contractor)
Stringing, Sagging, Binding and jumpering of ACSR Weasel Conductor as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of AB Cable 3x50 Conductor as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of AB Cable 3x95+1x70+1x16 Conductor as per RESSPO Norms
Grouting and Binding of Stay with in 1:4:8 ratio with cement, sand and brick ballast including cost of all grouting materials as per RESSPO Norms
Earthing of Poles as per RESPO Norms
Construction of Transformer Plinth including excavation of foundation, base concreting of 1:6:12 (Cement mortar of Ratio 1:4 foundation, CC in 1:4:8 ratio (Cement fine sand and brick ballast ) and RCC work with ratio 1:2:4 Cement, Coarse sand and Stone Grit of 20 mm gause as per RESSPO norms
Fencing of Transformer Plinth with the help of wire mesh/Barbed wire after grouting proper size of angle as per RESSPO Norms. Inclusive of all material such as Wiremesh/Barbed Wire, Angle Flats, Nut Bolts etc.
Earthing by way of boring and lowering of "B" class G.I. pipe 50 mm dia 20 mtr. Long from ground upto the water lavel it will be connected to the G.S. Strip for T/F nutral connection the earth strip will be welded to the G.I. pipe the work also included top cap and clamps for pouring water the cost of all material will all labour and T n P etc. complete in all respect . (all the material will be supplied by the contractor.)
Laying of underground 11 KV 3x185 sq mm XLPE Cable in Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable)
Laying of underground 11 KV 3x300 sq mm XLPE Cable in Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable)
Installation of Heat Shrinkable Type cable jointing kits Outdoor end Termination suitable for 11 KV XLPE cable 3x185 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Installation of Heat Shrinkable Type cable jointing kits Indoor end Termination suitable for 11 KV XLPE cable 3x185 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Installation of Heat Shrinkable Type cable jointing kits Outdoor end Termination suitable for 11 KV XLPE cable 3x300 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Installation of Heat Shrinkable Type cable jointing kits Indoor end Termination suitable for 11 KV XLPE cable 3x300 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Mounting of 25 KVA Transformer as per RESSPO Norms.
Mounting of 63 KVA Transformer as per RESSPO Norms.
Mounting of 250 KVA Transformer as per RESSPO Norms.
Connection of L.T. XLPE Cable Different Size
Rect. Back old and used 10 KVA T/F
Rect. Back old and used 16 KVA T/F
Rect. Back old and used 250 KVA T/F
Rect. Back AB Cable Single Phase
ALOK KUMAR SINGH
Hindustan Electric Work
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .