Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.8 L+₹25,144.90 (1.73%)Rejected-Finance | L2 | Rejected-Finance Rejected in AOC | |
| 3 | L3₹16.2 L+₹1.6 L (11.1%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance Rejected in AOC | |
| 4 | l4₹16.5 L+₹2.0 L (13.8%)Rejected-Finance | l4 | Rejected-Finance Rejected in AOC | |
| 5 | L5₹16.7 L+₹2.2 L (14.8%)Rejected-Finance | L5 | Rejected-Finance Rejected in AOC |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
28 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY SURATGARH
SURATGARH MIL STN
Provn of cooler stand, plate rack, connecting path in Bldg No P-136 and P-137 (ORs Md Accn) and certain sectioned works under AGE B/R-I at Suratgarh Mil Stn
2022_MES_527657_1
GE (A) SOG - 19/22-23
Open Tender
Civil Works
Item Rate
180 days
SURATGARH
As per tender documents
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹37,000
Yes
23 Jul 2022
31 May 2022
30 Jun 2022
31 May 2022
28 Jun 2022
14 Jun 2022
Amount
Demolition and breaking up 150 mm bore drain pipes (salt glazed stone ware, AC or reinforced concrete) including concrete bed and haunching and removing rubbish to a distance not exc 50m complete all as specified and as directed by Engineer-in-charge.
Excavation over areas not exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 3 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance exc 250 metre and not exc 500 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance exc 1.5 KM and not exc 5 KM and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/ loose soil and getting out complete all as specified and directed by Engineer-in-Charge.
Spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by Engineer-in-Charge
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer-in-charge.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed by Engineer-in-charge.
M&L for hardcore of broken stone / boulders gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
M&L for hard core of stone / boulders of gauge exceeding 63mm but n. exc 100mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-charge .
M&L for cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and directed by Engineer-in-charge. Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, coping, parapets and railing upto 60cm height, copings bed block,roof kerbs or mud stops, kerb stone, kneelers, apex stones, bed plates, surface channels and drains, benching, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs of drains, manholes, septic tanks, soakage wells etc. including placing in position and set in CM (1:6) complete all as specified & as directed by Engineer-in-charge. Note: - Reinforcement shall be measured and paid for separately.
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) nominal mix as in beams , cantilever, bressummer, lintel over 1.5m span and similar work complete all as specified and directed by Engineer-in-Charge
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for Cutting holes in brick walls built in cement mortar for inserting holdfasts, exc half brick & not exc one brick (Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall) and making good dismantled portion in cement mortar (1:3) complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick damp proof course to horizontal or vertical surfaces in PCC (1:2:4) type B0 using water proofing compound including necessary form work complete all as specified & directed by Engineer-in-Charge. Note : - Supply only water proofing compound shall be measured and paid for separately
M&L for continuous brick edging (sub class ‘B’) with width equal to the length of brick laid dry on edge vertically including necessary earth work, embedding bricks at depth as indicated and temping around bricks and removal of surplus soil to a distance not exceeding 50 metre and depositing where directed complete all as specified and directed by Engineer-in-Charge. Note : Each row shall be measured and paid separately.
M&L for use and waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
S&F 35 mm thick factory made plain framed, panelled shutter (any number of panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood (Hollock or Bonsum) complete all as specified and directed by Engineer-in-charge.
S&F 200 mm long mild steel barrel tower bolt stove enamelled black with bright bolt (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 100mm size mild steel butt hinges cold rolled medium weight (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 300mm long aluminium alloy anodised sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 150mm long extruded aluminium handles, anodised, fabricated type (ISI marked) complete all as specified and directed by Engineer-in-Charge
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring overall length of cover plate 140mm (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified and directed by Engineer-in-charge.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F mild steel work as in hand made sliding bolts, hold fast, wind tie for roof covering including securing bolts necessary drilling bolts or reiveting conforrming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge
S&F mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
All as per serial item No 37 here-in-before but 5mm dia and over up to and including 10mm dia as in stirrups, spacers & binder etc.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conforming to Fe-290 (Gde E- 165, complete all as specified & directed by Engineer-in-charge.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand 12mm sq guard bar, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
S&F Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, length of bolt not exc 15cm and dia of neck is 12mm long complete all as specified and directed by Engineer-in-Charge.
M&L for steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St.-240 including painted with one shop coat of zinc chromate primer paint including preparation of surface at contractor workshop before fabrication complete all as specified and directed by Engineer-in-charge.
Supply and fixing expanded metal of weight not exceeding 4 Kg per Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanized steel staples supplied and fixed or welded to steel members complete all as specified & as directed.
S&F pressed steel frames for door of size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc made out of mild steel sheet of 1.25mm thickness complete all as specified and as directed by Engineer-in-charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick (minimum size 550mm x 550mm or size as directed) laid over & including screed bed or bedding layer of 15mm thick in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for machine cut Kota stone slab 18 to 20mm thick (minimum size 550mm x 100mm or size as directed), on vertical surfaces such as dado, skirting, raiser of steps etc. laid over & including rendering 10mm thick in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, grinding, rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for 50 mm thick PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for 100 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic tiles (coloured) 450mm x 350mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
S&F factory casted 80mm thick precast concrete interlocking paving blocks M-40 having compressive strength not less than 400 Kg / Sqcm using grey cement and no pigment and of shape hexagon/ triangular / zigzag / I-shaped / Three-X etc as directed conforming to IS 15658-2006, laid dry over and including 25mm thick layer of local tibba sand cushining over complete all as specified and directed by Engineer-in-Charge.
S&F factory casted 60mm thick machine pressed cement concrete interlocking paving blocks M-35 having compressive strength not less than 350 Kg / Sqcm using grey cement and no pigment and of shape hexagon/ triangular / zigzag / I-shaped / Three-X etc as directed conforming to IS 15658-2006, laid over & including 25mm thick sand cushion (local tibba sand), laid dry, joint filled with dry sand complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering in cement mortar (1:4) on brick walls/concrete surfaces mixed with water proofing compound as per manufacturer’s instructions including finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge. Note : - Supply only water proofing compound shall be measured and paid for separately under respective item of BOQ.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rough cast finish plaster with a mixture consisting of crushed stone or fine gravel aggregate mixed with coarse sand and cement in the ratio of 1:1:1 over & including 12mm thick rendering in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces of walls complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surface of walls & applying two coats of cement base paint of approved shade/tint and filling cement based putty in cracks complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified and as directed.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F 15mm dia stop cock cast copper alloy, fancy type with, chromium plated long shank and cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F stainless steel plate rack of size 750mm x 600mm x 254mm made out of 0.63mm thick stainless steel of first quality complete all as specified and directed by Engineer-in-Charge. Make: Silver Shine (Blue Star sanitary industries Pvt Ltd) Model No KPR 313 / Prayag model No P-340 / Blue Star (Anupam Industries) model No KPR-313 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F DWCPE (SN8) pipe 200 mm dia (inner) as per IS-16098 (Part-II) laid in trenches or in floor on moorum bed to required shape including all necessary accessories / fitting / jointing / rings, joiting and testing complete all as specified & directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe complete all as specified and directed by Engineer-in-charge.
M&L for 150mm bore salt glazed stone ware drain pipes of grade ‘A’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified and directed by Engineer-in-charge.
Material & labour construction of Soak Well for 51 to 100 users as shown on drawing No.GE(A) /comp / 17 / 2016 complete all as specified and as directed by Engineer-in-charge. Notes : Irrespective to whether shown on drawing or not, excavation & earthwork shall be in any type of soil, brick work shall be in CM 1:4, over burnt brick bats shall be used for filling, PCC 1:4:8 type D2 using 40mm graded stone aggregate shall be provided in foundation, 20mm dia MS rungs made to shape painted with two coats of bituminous paint shall be provided, PCC 1:3:6 type C2 using 40mm graded stone aggregate shall be provided in plinth protection, 1.50m long 150mm bore cast iron sand cast inlet pipe shall be provided and slab shall be Precast RCC (1:2:4). Other details shall be as shown on drawings & as specified in particular specifications.
M&L for Modular point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated multistranded unsheathed copper conductor cable drawn in and including concealed PVC rigid conduit medium grade 20mm dia, pipe hooks, elbows, junction covers and junction boxes including cutting chases in walls for conduits and for sunken pressed steel terminal boxes and making good the disturbed surfaces of wall with all jointing accessories including provision of pressed steel sunken terminal boxes made of 1.2mm thick pressed steel sheet, 60mm deep of suitable length and painted with red oxide primer for mounting modular switches, sockets, fan regulator including suitable size modular plates fixed flush with wall including 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. Note : The quoted rate shall be deemed to included with modular cover plates with frame of any colour and metal flush boxes of suitable size as directed by Engr-in-Charge.
S&F Modular switch piano 16 Amps single pole, one way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular socket 6 pin, 6 / 16 Amps, 230 volts, combined 2 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular electronic fan regulator suitable for ceiling fan 2 Module, 1200mm / 1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 76 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 76 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per Srl item No. 76 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 6 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F flush mounting factory made SPN DB 8 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507611 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408618 or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply and fixing LED lamp minimum 3 star rated 12W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : Morethan 80
S&F sheet metal enclosure DB concealed with wall having facility to fix MCCB as incomer and MCBs in outgoing, TP vertical type 04 way of double door, complete fitted with bus bars, neutral links, G frame including 04 pole MCCB 63 Amp capacity 50 Hz, 10 KA breaking capacity GS frame type, blanking plates including making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. Make of DB :- Havells Cat part No DHDLVDRWAOFO04, and MCCB cat part No IHLGSF0063 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim, prewired, lumiline 18 watt LED light fitting (Day cool light), batten type with drive & polycarbonate housing including tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS18WLED865 SPCWH / Syska Cat part No SSK-RA1801 Wipro cat part No LL20-221-XXX-65-NE / Philips cat part No 61009 BL CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim, prewired, aluminium body 20 watt LED light fitting (Day cool light), batten type with drive including polycarbonate diffuser with tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Syska Cat part No SSK-ALB-20W or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F LED post top 35 watt decorative circular design energy saving, IP 65 protection environmental freindly, long life aesthetically designed with symmetrical light distribution, cast aluminium body landscape luminaire with high power LEDs with polycarbonate type diffuser including two coat of black painting on existing post and cement work in base stand (spigot housing with decorative opal acrylic diffusser and IP 65 protection with all accessories complete all as specified and as directed by Engineer-in-charge. Make :- Havells cat part No RUBYPT35WLED830PSY MTOPC or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F ceilling fan 1200mm sweep including fan regulator and making electric connections with 0.60RM long flexible cable of size 23/0.0076 mm complete all as specified and directed by the engr-in-charge complete all as specified and directed by Engineer-in-charge. Make : Havells Model No ES-50 Premium 5 or equivalent in makes mentioned in Appendix 'A' here-in-after. Note :- (i) MES No with stencil shall be marked on ceiling fan body using synthetic enamal paint. Cost of the same is included in the unit rate of this item.
S & F pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and yellow colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
S&F street light pole box of size not less then 300x200x105mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 65 for outdoor Installation with internallly embedded gasket (PUR) including MCB SP 6 Amps 01 No along with left side hinge door (notch arrangement not acceptable) & premoulded knockout all sides including back of the base must. The box fitted with 10 sqmm stud type terminal - 04 Nos including Elimex stud type TB 4 Nos. Note :- (i) Cost of flat iron clamp is deemed to included in unit rate of this items. Nothing extra shall be paid on this account. (ii) Size of junction box for different mafufacturer may slightly varried from size mentioned in description of item. Contractor has to provide junction box as per cat No mentioned against make of junction box. where cat No is not mentioned against any make, in that case junction box of size mentioned in description has to provide, if exact size of junction box is not available, then next higher size junction box has to be provided. Nothing extra shall be paid on this account.
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc including grouting 4 Nos bolts in PCC (1:2:4) block in wall and making good the disturbed surfaces matching with existing including making connection to elerctric supply complete all as specified and directed by the engr-in-charge.
S&F street light bracket made out of 40mm dia GI pipe light grade 1.5m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts, washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F street light bracket made out of 40mm dia GI pipe light grade 1.20m long , bent to shape at 120 degree angle from vertical fixed along pole with and dirlling holes including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint including any addition / alteration (if required) for fixing street light complete all as specified and as directed by Engineer-in-charge.
Supply and fixing energy efficient LED street light fitting of 30W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : Morethan 80 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
All as per Srl item No 100 above but LED street / security light of 35 watt.
All as per Srl item No 100 above but LED street / security light of 45 watt. Notes for srl Item No 100 to 102 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F LED flood light of 100 watt with high pressure die cast housing with lens with lument output 6000K complete (including LED, drive and internally prewired) with on board 5 KV surge protection with 10 KV external SPD. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS 10322-1982 (part-I) with latest amanedments and input voltage range 140-300V AC, frequency 50-60 Hz, P.F should be more than 0.9. The efficiency of LED luminaries system shall be more than 100 lumens per watt and FRLSH cable PVC insulated stranded copper conductor, 1100 volts grade, 2.5 sqmm x 3 core of ISI marked for light to ceiling rose complete including arrangement of mounting for street light as required at site complete all as specified and directed by Engineer-in-charge. Make :- Crompton Cat part No LFLN-150-CDL/60-M / Wipro cat part No LF07-152-090-50-V5 / Philips cat part No BVP122 LED 150 CW HE NB FG XTFCL S4 or equivalent in makes mentioned in Appendix 'A' here-in-after.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009complete all as specified and directed by Engr-in-charge. Notes :- (i) GI wire upto DBs or upto earth test point is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for RCC cover shall be 1 KG.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 16 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 105 above but cable of cross sectional area 6 sq mm 2 core including taking out old cable
All as per item No 105 above but cable of cross sectional area 10 sq mm 2 core including taking out old cable
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note : - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
Supply installing & testing water cooler of 80 Ltr storage capacity with nominal cooling capacity 40 Ltr per hour, single phase , 230 volts, Five Star Rating with necessary inlet connection with HDPE / Flexible pipe both ends CP brass union for GI Pipe and ball brass valves complete including electric connection through voltage stabilizer complete all as specified and directed by Engineer in charge. Make:- Blue Star Model No SDIx 480 / Usha Model No SS 4080 or equivalent in makes mentioned in Appendix 'A' here-in-after. Note :- Voltage stabilizer shall be measured and paid seperately under respective items of BOQ
S&F Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account..
All as per item No 111 above but 50mm bore tubing
All as per item No 111 above but 32mm bore tubing
All as per item No 111 above but 15mm bore tubing -------------------------------------------------------------------- Note :- A sum of Rs. 300/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 33 (Schedule of Credit) of Tender documents.
AK CONSTRUCTION
M/s JUGAL KISHORE MISHRA AND SONS
Gupta Suppliers
SAHIL BUILDERS
K M TILES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .