ESTATE OFFICER
TANUVAS MMC CHENNAI 51
As per BOQ
2026_TNVAS_726764_1
19.1/EO/DB/Tender/2026-27 dt12.11.26
Open Tender
Civil Works
Lump-sum
90 days
MMC CHENNAI
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹9,600
17 Nov 2026
17 Nov 2026
2 Dec 2026
17 Nov 2026
2 Dec 2026
17 Nov 2026
90 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Civil Works | |||||
| 1.01 | Dismantling the Floor finish and dadooing walls in cement mortar with mosaic tiles / glazed tiles / cuddapah slabs and clearing away the rubbish from the site for initial lead and lifts, etc. complete. | 25 | Sqm | - | - |
| 2 | Dismantling lime concrete in the foundation and clearing the rubbish from the foundation for initial lead and lifts, etc. complete. | 1.5 | Cum | - | - |
| 3 | Dismantling the Brick / stone masonry in Cement mortar walls under 3m high and clearing away the rubbish from the site for initial lead and lifts, etc. complete. | 0.75 | Cum | - | - |
| 4 | Painting Old Plastered Wall Surface with One finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) | 415 | Sqm | - | - |
| 5 | Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) | 815 | Sqm | - | - |
| 6 | Providing and carrying out minor repair works to existing aluminium doors, windows and ventilators, including replacement of damaged rubber gasket/weather strip, repair/replacement of locking arrangement, adjustment and alignment of shutters, hinges/rollers and fittings, removal of floor rubbing, sealing of gaps and joints with suitable weatherproof sealant to prevent rainwater ingress, and making the units smooth in operation and proper closing, complete in all respects as directed by the Engineer-in-Charge. | 50 | Sqm | - | - |
| 7 | Providing and fixing Premium quality Vertical blinds with 100mm wide, UV-resistant polyester fabric of minimum 180 GSM, powder coated aluminium headrail, smooth operating chain and cord mechanism, including nylon runners bottom weights connecting chains, brackets, screws and all necessary accessories including cost of materials, labour, transportation and fixing complete as directed by the Engineer-in-charge. | 36.57 | Sqm | - | - |
| 8 | Fabricating Supplying and fixing in position of Aluminium Powder coated 1/3rd fixed glazing 2/3rd prelaminated board of Aluminium partition of size 3.50 x 2.88m. The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/ m, Centre mullions: 63.50x38x3mm@ 1.55 kg/m,Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 5.5mm thick plain glass with necessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes in RCC column, masonry wherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing etc. complete complying with standard specification and as directed by the departmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be got approved by Executive Engineer before use. | 40 | Sqm | - | - |
| 9 | Supplying and fixing in position white glazed European Water Closet of best quality and approved make with 100 mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) | 4 | Nos., | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
BOQ_872450.xls
BOQ • 0.37 MB
TenderDocument.pdf
Tender Documents • 1.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .