| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAdmitted-Finance | ₹1.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.4 Cr+₹28,930 (0.21%)Admitted-Finance | ₹1.4 Cr+₹28,930 (0.21%) | L2 | Admitted-Finance |
| 3 | L3₹1.5 Cr+₹14.4 L (10.4%)Admitted-Finance | ₹1.5 Cr+₹14.4 L (10.4%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical KUNZER KUNZER TANGMARG BARAMULLA JAMMU KASHMIR 193401 | BUDGAM | JAMMU AND KASHMIR | 193401 | - | - | Rejected-Technical Not Qualifies |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Qualifies |
| Sl No | Description | Qty | Unit | TZ Engineering Works L1 | M/S MARIB CONSTRUCTIONS L2 | Ali Mohammad Baba and Sons L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply ,Installation.Testing & Commisioning of Distribution Transformer Energy Efficientcy Level 2nd 1000KVA,11/0.433KV 50Hz,Outdoor type,Dyn-11 oil immersed,CopperWound,ONAN Cooled, step down ,Distribution Transformer having C.R.G.O core ,Confirming to IS: 1180 Part-1:2018 with latest amendments dully tested,painted and Oil filled to IS: 335 of 1983 with Latest amendments.The transformer shall be complete with following fittings:-
a) Oil conservator with oil level indicator , minimum level marking and drain plugs. b) Off circuit type tap changer with position indicator and locking arrangement. c) 100mm dial type /Stem type thermometer with metal gaurd. d) Lifting lugs and Bi-directional roller. e) Rating Diagram and terminal marking plate f) Explosion Vent and valves for filtration ,drainage and filling e.t.c with necessaryplugs ,including air release plug. g) Radiator assembly and silica gel breather. (ALBA/ABB/BHEL/Crompton/Andrew-yule/Electric field/JK Transformers make) | 2 | job | 16,00,000 ₹32,00,000 | 13,96,000 ₹27,92,000 Lowest | 17,83,000 ₹35,66,000 |
| 2.00Contruction Of RCC bed for 1000 KVA transformer 6' x 8' x 5' | ||||||
| 3.00 | a) Earth work excavation manually inculding disposal of earth as directed within SKIMS permises=8'x6'x1'-0" X 2 no. | 6 | CUM | 200 ₹1,200 Lowest | 2,000 ₹12,000 | 300 ₹1,800 |
| 4.00 | b) P/L of stone soling of specified size including Cost & carraige of material complete, 8'x6'x0'-4"=15.84cft =0.448 cum X 2 no. | 1 | CUM | 700 ₹700 Lowest | 6,500 ₹6,500 | 1,844 ₹1,844 |
| 5.00 | c) P/L of plain cement concrete 1:4:8 mixture incuding cost & carriage of material complete Qty vide part (b) = 0.448 cm X 2 no. | 1 | CUM | 5,000 ₹5,000 Lowest | 5,500 ₹5,500 | 12,000 ₹12,000 |
| 6.00 | d) P/L of R.C.C work 1:2:4 mix including cost and carriage of material 8'x6'x5' = 240 cft X 2 no. | 13.58 | CUM | 8,500 ₹1,15,430 | 5,500 ₹74,690 Lowest | 11,200 ₹1,52,096 |
| 7.00 | e) P/L of steel reinforcement (TMT) 12mm dia including cost of cutting, bending ,binding including cost binding wire Qty vide item (d) = 6.79 cum @ 35 kg/cum X 2 no. | 500 | KGS | 100 ₹50,000 | 85 ₹42,500 Lowest | 90 ₹45,000 |
| 8.00 | f) Shuttering by steel plates/ wooden planks including removal of same after use. | 13 | Sqmtr | 100 ₹1,300 | 500 ₹6,500 | 20 ₹260 Lowest |
| 9.00 | Supply, installation, testing and commissioning of servo motor operated line voltage correctors copper wound. Indoor, continuous duty, three phase, to work under unbalanced condition of input voltage and unbalance load which shall comprise 3 nos. fully IC controlled sensing circuit microprocessor based with built in filters & improve the output wave to be pure sinusoidal and control each phase individually. Conforming to IS. 9815: with input voltage range: 250-460V (phase to phase), output voltage 415 (As set output voltage), ± 1%,with under voltage, over voltage & over current protection, naturally oil cooled with first filling of transformer oil with necessary bypass switch arrangement complete with following accessories etc. as required. (Make as Per Makelist Annexed to NIT )
Capacity - 800 KVA Input - 250 – 460 V AC
Output - 415 V + - 1 % First filling of oil
Drive : Heavy duty A.C Sychronous Motor
Alarms:
a) Input low voltage cutoff . b) Input High voltage cutoff.
c) Output low voltage cutoff. d) Output High voltage cutoff
Controls:
a) Auto/Manual. b) Manual Bypass changeover Switch
c) Manual Raise/Lower for output voltage d) Metering digital.
Under / Over Voltage Cutoff Protection Using Contactor 1250A
Stabiliser Standard:- As per IS: 9815, 1250 Amp.FP ACB ( Electrically Operated ) having breaking capacity atleast 50KA at input for over load and short circuit protection in M.S. enclosure with bus bar.Manual By-Pass / Changeover Switch 1250A - With Enclosure.Complete as per SBD. | 2 | job | 23,00,000 ₹46,00,000 Lowest | 26,08,200 ₹52,16,400 | 31,19,000 ₹62,38,000 |
| 10.00 | Providing and making of earth pits using appropriate mixture of salt and charcoal.The job includes providing fixing of copper plate of size 600mmx600x3mm, pit should be dug 3 mtr from the surface including 25mmx5mm copper strip in separate 1½" G.I Pipe from plate to surface and laying of 40 mm G.I water pipe to the plate complete as per latest specification. | 12 | job | 14,000 ₹1,68,000 | 6,500 ₹78,000 Lowest | 18,000 ₹2,16,000 |
Tender Value
Refer Docs
EMD Value
₹3.0 L
Closing Date
3 Feb 2021, 4:00 pmClosed
Ex. Engineer Electrical SKIMS
Ex. Engineer Electrical SKIMS Soura
SITC of 1 MVA Distribution Transformer Servo stabilizer and LT Panel Along with Allied Works in ESS BLOCK of Maternity Hospital at SKIMS Soura
2020_SKIMS_112242_1
eNIT NO.SIMS/HEE/E/ET/47 of 2020-21 Dt.23-12-2020
Open Tender
Electrical Works
Item Rate
60 days
SKIMS Soura
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,000
Yes
Director Finance SKIMS
₹3.0 L
Yes
21 Jun 2021
24 Dec 2020
6 Feb 2021
24 Dec 2020
3 Feb 2021
25 Dec 2020
Amount
Supply ,Installation.Testing & Commisioning of Distribution Transformer Energy Efficientcy Level 2nd 1000KVA,11/0.433KV 50Hz,Outdoor type,Dyn-11 oil immersed,CopperWound,ONAN Cooled, step down ,Distribution Transformer having C.R.G.O core ,Confirming to IS: 1180 Part-1:2018 with latest amendments dully tested,painted and Oil filled to IS: 335 of 1983 with Latest amendments.The transformer shall be complete with following fittings:- a) Oil conservator with oil level indicator , minimum level marking and drain plugs. b) Off circuit type tap changer with position indicator and locking arrangement. c) 100mm dial type /Stem type thermometer with metal gaurd. d) Lifting lugs and Bi-directional roller. e) Rating Diagram and terminal marking plate f) Explosion Vent and valves for filtration ,drainage and filling e.t.c with necessaryplugs ,including air release plug. g) Radiator assembly and silica gel breather. (ALBA/ABB/BHEL/Crompton/Andrew-yule/Electric field/JK Transformers make)
Contruction Of RCC bed for 1000 KVA transformer 6' x 8' x 5'
a) Earth work excavation manually inculding disposal of earth as directed within SKIMS permises=8'x6'x1'-0" X 2 no.
b) P/L of stone soling of specified size including Cost & carraige of material complete, 8'x6'x0'-4"=15.84cft =0.448 cum X 2 no.
c) P/L of plain cement concrete 1:4:8 mixture incuding cost & carriage of material complete Qty vide part (b) = 0.448 cm X 2 no.
d) P/L of R.C.C work 1:2:4 mix including cost and carriage of material 8'x6'x5' = 240 cft X 2 no.
e) P/L of steel reinforcement (TMT) 12mm dia including cost of cutting, bending ,binding including cost binding wire Qty vide item (d) = 6.79 cum @ 35 kg/cum X 2 no.
f) Shuttering by steel plates/ wooden planks including removal of same after use.
Supply, installation, testing and commissioning of servo motor operated line voltage correctors copper wound. Indoor, continuous duty, three phase, to work under unbalanced condition of input voltage and unbalance load which shall comprise 3 nos. fully IC controlled sensing circuit microprocessor based with built in filters & improve the output wave to be pure sinusoidal and control each phase individually. Conforming to IS. 9815: with input voltage range: 250-460V (phase to phase), output voltage 415 (As set output voltage), ± 1%,with under voltage, over voltage & over current protection, naturally oil cooled with first filling of transformer oil with necessary bypass switch arrangement complete with following accessories etc. as required. (Make as Per Makelist Annexed to NIT ) Capacity - 800 KVA Input - 250 – 460 V AC Output - 415 V + - 1 % First filling of oil Drive : Heavy duty A.C Sychronous Motor Alarms: a) Input low voltage cutoff . b) Input High voltage cutoff. c) Output low voltage cutoff. d) Output High voltage cutoff Controls: a) Auto/Manual. b) Manual Bypass changeover Switch c) Manual Raise/Lower for output voltage d) Metering digital. Under / Over Voltage Cutoff Protection Using Contactor 1250A Stabiliser Standard:- As per IS: 9815, 1250 Amp.FP ACB ( Electrically Operated ) having breaking capacity atleast 50KA at input for over load and short circuit protection in M.S. enclosure with bus bar.Manual By-Pass / Changeover Switch 1250A - With Enclosure.Complete as per SBD.
Providing and making of earth pits using appropriate mixture of salt and charcoal.The job includes providing fixing of copper plate of size 600mmx600x3mm, pit should be dug 3 mtr from the surface including 25mmx5mm copper strip in separate 1½" G.I Pipe from plate to surface and laying of 40 mm G.I water pipe to the plate complete as per latest specification.
Providing and fixing of 25mm x 5mm G.I strip from earth pits to 1000 KVA Distribution Transformer /Servo stabiliser/ LT Panel to be laid through 2 mm thick MS conduit of appropriate dia .
Supplying, installation, including suspension, testing and commissioning of following capacity bus trunking with aluminium bus bars having current density of 130 A/ sq. cm at nominal current rating in 1.6mm thick IP 42 sheet steel enclosure in convenient sections for use on, 3 phase, 4 wire, 415 V, 50 Hz, A.C. supply including jointing of sections, flexible joints, expansion joints, bends and earthing with 2 runs of galvanised iron strips, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required(Make as Per Makelist Annexed to NIT )
OUTGOING: SECTION-1 1000 Amp 415 V TP ACB MDO TYPE having breaking capacity - 50 KA, with Ics=Icu=50 KA, - 1 Nos. 630 Amp 415 V TP MCCB having breaking capacity - 50 KA, with Ics=Icu=50 KA, with Rotary Handle operating Mechanism - 2 Nos. 400 Amp 415 V TP MCCB having breaking capacity - 36 KA, with Ics=Icu=50 KA, with Rotary Handle operating Mechanism - 2 Nos. 320 Amp 415 V TP MCCB having breaking capacity - 36 KA, with Ics=Icu=50 KA, with Rotary Handle operating Mechanism - 2 Nos. 100 Amp 415 V TP MCCB having breaking capacity - 25 KA, with Ics=Icu=50 KA, with Rotary Handle operating Mechanism - 2 Nos. 63 Amp 415 V TP MCCB having breaking capacity - 10 KA, with Ics=Icu=10 KA, with Rotary Handle operating Mechanism - 2 Nos. (CONTINUED IN BELOW CELL)
OUTGOING: SECTION-2 1000 Amp 415 V TP ACB MDO TYPE having breaking capacity - 50 KA, with Ics=Icu=50 KA, - 1 Nos. 630 Amp 415 V TP MCCB having breaking capacity - 50 KA, with Ics=Icu=50 KA, with Rotary Handle operating Mechanism - 2 Nos. 400 Amp 415 V TP MCCB having breaking capacity - 36 KA, with Ics=Icu=50 KA, with Rotary Handle operating Mechanism - 2 Nos. 320 Amp 415 V TP MCCB having breaking capacity - 36 KA, with Ics=Icu=50 KA, with Rotary Handle operating Mechanism - 2 Nos. 100 Amp 415 V TP MCCB having breaking capacity - 25 KA, with Ics=Icu=25 KA, with Rotary Handle operating Mechanism - 2 Nos. 63 Amp 415 V TP MCCB having breaking capacity - 10 KA, with Ics=Icu=10 KA, with Rotary Handle operating Mechanism - 2 Nos. BUS BAR 4 strip Al. busbar of 1600 A capacity complet with all accessories
Supply and laying of 120 mmsq 3core 11 KV (E) XLPE cable circular aluminium conductor, conductor screened, XLPE insulated, insulation screened with extruded semi-conducting compound in combination with copper tape. Aluminium round wire armoured and overall PVC sheathed earthed cable conforming to IS:7098/II/85 with latest amendments.(Havells/Polycab/KEI/Gloster/Paramount make)
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :(Denson /3M/ Frontec/Raychem make)
Supply,testing,connecting & Commissioning of 1000 mm ² single core Aluminium PVC Sheathed Armoured cable (ISI Marked) (Polycab /Havells/Gloster/KEI/Skytone make) from alternator to AMF Panel to main sub-station 1600 Amp Changeover switch
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective brick covering and refilling the trench etc as required. a ) 1000 mm Sq.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. a) 1000 mm Sq.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. a) 1000 mm Sq.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. a) 1000 mm Sq.
Providing and making of end termination of 1000 mm² single core Aluminium cable including thimbling, crimpingincluding colour coded heat shrinkable slecrc, testing and connecting as per site requirements (dowels /3D make)
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required..
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
Providing and fixing of brass compression Cable Glands of 1000 mm sq. single core Aluminium Cable .
M/S MARIB CONSTRUCTIONS
Ali Mohammad Baba and Sons
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .