| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹20.9 L+₹4.2 L (24.8%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹25.9 L+₹9.2 L (54.6%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹26.2 L+₹9.4 L (55.9%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹27.5 L+₹10.7 L (64.0%)Rejected-Finance AZARA PO KAMRUP DIST GUWAHATI 781 015 ASSAM | KAMRUP METRO | ASSAM | 781015 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹24.7 L
EMD Value
₹49,460
Closing Date
13 Nov 2023, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
PROVN OF PARKING SHED FOR SPECIALIST SERVICES VEHICLES AT 344 TRU UNDER GE AF BORJHAR
2023_MES_622039_1
8369/BOR/E8
Open Tender
Construction Works
Item Rate
180 days
GE (AF) Borjhar
Class E Cat a(i)
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹49,460
Yes
21 Feb 2024
7 Oct 2023
15 Nov 2023
7 Oct 2023
13 Nov 2023
26 Oct 2023
Amount
Surface excavation not exc. 30cm deep and averaging 15cm deep and getting out in soft/ disintegrated rocks, complete all as specified and as directed.
Removing excavated soil n.exc 250m and n.exc 500m, depositing where directed at a level n.exc 1.5m above the starting point, complete all as directed.
Hardcore of broken stone aggregate of gauge n exc 63mm, deposited, spread and levelled in layers not exc, 15cm thick, watered and rolled/rammed to a true surface, complete all as specified and as directed.
M & L for 100 mm thick plain cement concrete (1:3:6) mix, type C-1 using 20mm graded stone aggregate as in sub-base flooring/hard standing, complete all as specified and directed.
Supplying and laying 80mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickniess and size/shape, made by table vibratory method using PU mould laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
S & F precast cement concrete manhole type B-1, (1:2:4) using 20mm graded stone aggregate as in kerbs, etc., complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, 'U' hook or 'J' bolt, complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, 'U' hook or 'J' bolt, complete all as specified and directed.
Excavation in post holes (or similar holes each n.exc 0.50 Cum, getting out in soft/disintegrated soil and removing surplus soil to a distance n.exc 50m and making good disturb ground, complete all as as directed.
M & L PCC 1:3:6, type C-2 (using 40mm graded aggregate) foundations, filling and mass concrete etc., complete all as specified and as directed.
M & L for roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., and welding counter sunk for holes and necessary gusset plates etc and similar work conforming to Fe-410W (Gde E-250 quality A) complete all as specified and directed by Engr-in-Charge.
M & L for 50 mm thick plain cement concrete (1:2:4) mix, type B-1 using 20mm graded stone aggregate as in sub-base, plinth protection etc., ,complete all as specified and directed.
M & L painting on new steel surfaces of any description not otherwise described over 10cm width or girth applying two coats anti corrosive paint over one coat of zinc primer including preparation of surfaces complete all as specified and directed by Engr-In-Charge .
M & L for brick work with sub class 'B' bricks straight or curved on plan exc. 6 metre mean radius, built in cement mortar CM (1:6), complete all as specified and as directed.
M & L for rendering 15mm thick on fair faces of bricks/concrete surface work in cement mortar (1:4) using Water Proofing Compound (WPC) as per manufacturer's instructions on walls finished even and smooth without using extra cement, complete all as specified and as directed. (Note: WPC shall be measured and paid separately).
Supply only integral proofing compound, complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of cement based paint over a coat of alkali resistant primer, complete all as specified and as directed.
M & L for providing gypsum board of 8mm thick ceiling tiles sizes 595mm x 595 mm including aluminium anodised section of size, wall angle 25mm x 25 mm x 2 mm thick, main/cross tee-section 15mm x15mmx 1.4mm and suspended with 2.18 mm thick GI wire of suitable length and including fixed and aluminium snap grid all as per clause 10.38.1 of SSR Part-I and as per manufacturer's instructions, complete all as specified and as directed.
Excavating over areas, n.exc 1.5m deep and getting out in soft/loose soil, complete all as as directed.
M & L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete etc., complete all as specified and as directed.
M & L for RCC M-25 Design Mix concrete as in wall footing/column footing, upto bottom of plinth beam and in plinth beam, complete all as specified and as directed.
M & L for RCC M-25 Design Mix concrete as in slab supported on beam/wall etc., complete all as specified and as directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, columns up to plinth beam and plinth beams; and similar work; vertical of batter, fair finished surfaces, complete all as specified and as directed.
M & L for formwork to sides of concrete walls beams/roof beams, supported on walls, columns etc., fair finished surfaces, complete all as specified and as directed.
S & F mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed.
S & F mild steel TMT bars 8 mm to 10 mm dia and over cut to length, bent to shape required including cranking bending spirally for hooping, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia or securing with clips , complete all as specified.
Returning and filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm, complete all as directed. (8+10)
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as directed. (10+4)
M & L for point wiring for light point controlled by one way switch 5 Amp, 1.5 Sq mm PVC FRLS insulated unsheathed, copper conductor stranded 1100 volts grade cable including PVC casing and capping of size not less than 25x12 mm/32x12 mm suitable and conduit pipe medium grade as per site requirement, ISI marked with accessories such as tee, bend joint cover etc., round/square blocks at junctions etc., screws, gutti/rawl plug PVC, all as per site requirements including plastic terminal boxed for mounting of switches/sockets/regulator etc., and PVC FRLS insulated and unsheathed 1100 volt grade copper conductor, stranded 1.5 Sqmm, cable a continuous earth lead connected to common earth dolly, etc., complete all as specified and directed. Note: Proper colour coding to be adopted.
M & L for point wiring for flood light point with 2.5 Sq mm PVC FRLS insulated unsheathed, copper conductor stranded 1100 volts grade cable including PVC casing and capping of size not less than 25x12 mm/32x12 mm suitable and conduit pipe medium grade as per site requirement, ISI marked with accessories such as tee, bend joint cover etc., round/square blocks at junctions etc., screws, gutti/rawl plug PVC, all as per site requirements including plastic terminal boxed for mounting of switches/sockets/regulator etc., and PVC FRLS insulated and unsheathed 1100 volt grade copper conductor, stranded 2.5 Sqmm, cable a continuous earth lead connected to common earth dolly, etc., complete all as specified and directed. Note: Proper colour coding to be adopted.
All as per item No. 29.00 here-in-before but with socket outlet 5 Amps, controlled by one way switch on the same board.
All as per item No. 30.00 here-in-before but with socket outlet 5 Amps, controlled by one way switch on independent board.
All as per item No. 30.00 here-in-before but with 4 Sqmm for one 15 Amps socket outlet on independent board and 4 Sqmm PVC insulated multi stranded copper conductor cable as continuous earth wire.
S & F switch piano flush button single pole one way 5 Amp, 230 volts, complete all as specified and as directed.
S & F Switch socket combination 2 in 1, 3 pin, 5 Amp flush type, universal, complete all as specified and directed.
S & F Switch socket combination 2 in 1, 3 pin, 6 Amps and 16 Amps flush type, universal, 230 volts, complete all as specified and directed.
Supply and fix ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified.
S & F surface mounted batten type LED luminaires 20W, 230 V AC on wall by stainless steel screw, rawl plug etc., and connecting upto ceiling rose with three core sheathed copper conductor cable (white/grey colour of suitable size), complete all as specified and as directed.
Supply and fixing ceiling fans BLDC type, 5 star rated with two module regulator with all accessories such as canopy, down rod etc., 140-285V, 345 RPM 1200 mm sweep, air delivery 232.00 cfm, 0.9 Power factor, complete all as specified and as directed by Engr-in-Charge
Supply and fixing exhaust fans heavy duty AC single phase, 230 Volt of size 300 mm sweep heavy duty with copper winding complete including making hole in existing wall and finishing with cement ratio (1:4) of 15 mm thick plaster work on brick surface/concrete surface/stone with louvers/flip cover of exhaust fan made with 0.5 mm thick sheet in square/round, complete all as specified and as directed by Engr-in-Charge
Supply and fixing LED flood light, 100 Watts, 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant, complete with driver and lamp, complete all as specified and as directed by Engr-in-Charge
M & L Sub main wiring two single core 6 Sqmm PVC insulated PVC multistanderd copper conductor cable heavy duty and one run of 6 Sqmm PVC insulated unsheathed multi stranded copper conductor cable for earth wire drawn in & including PVC casing and capping of size not less than 25x12 mm/ 32mx12mm with fittings (ISI marked) and making good disturbed surface wall complete all as specified and as directed. Note : - Not : 2 runs of 6 Sqmm cable and 1 run of earth wire 6 sqmm shall be measured as one unit length.
S & F single pole and neutral (SPN) enclosure with a two pin and earth plug and socket, complete with one single pole MCB 20 Amp, complete all as specified and as directed.
S & F sheet metal enclosures MCB SPN distribution board 12 way double door with IP-43 IK-09 protection single phase 240 volts, including 200 Amp rated copper bus bar and neutral link (ISI marked), fixed flush in wall/surfaces, complete all as specified and as directed.
S & F 240V, 10 kA 'C' Curve miniature circuit breaker (MCB) of single pole and neutral (SPN) and current carrying capacity 32 Amp in the MCB DB complete with connection testing and commissioning all as specified and as directed. Make: As specified in List of Makes.
S & F 240V, 10 kA 'C' Curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity 6 to 32 Amp in the MCB DB complete with connection testing and commissioning all as specified and as directed. Make: IndoAsian or its equivalent make in Havells/Standard/L&T.
M&L, for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, as shown in electrical plate No.3 of SSR Part-I, connected to earthing testing point all as specified and directed including excavation and connected work in hard/dense soil, PCC 1:3:6 ty C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm dia bore GI light grade as earth lead protection pipe, 50mm thick RCC 1:2:4 type B-1 cover slab of size 300x300x50 mm as earth lead protection pipe, 50 mm thick RCC (1:2:4) type B-1 cover slab of size 300x300x50 mm as earth pit cover reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing complete all as specified and directed. Note : (a) Rate quoted deemed to be included of excavation and earthwork in any type of soil with PCC type C-1 in pit PCC cover (b) Earth test result should not less than one ohm.
M & L connecting of 1100 Volts grade heavy duty XLPE, cable with PVC insulated conductor served with inner sheathing of PVC tape armoured with galvanised steel strip or wire and overall PVC sheathed of size 10 Sqmm nominal cross section 2 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers testing and commissioning complete all as specified, complete all as specified and as directed. (Earth work shall be measured and paid separately)
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5 m in depth, and getting out in soft/loose soil, for laying of underground cable etc., complete all as as directed.
Supply and laying dry sand of approved quality for cushioning of underground cable laid in trenches 8 cm deep before laying the cable and 15 cm thick after laying and stretching the cable, complte all as specifed and directed. (Note: Punned thickness of sand cushioning only shall be measured and paid for)
M & L for brick protection with old size sub class 'B' brick for PVC underground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT underground cable, complete all as specified and as directed.
Supply and fixing GI pipe light grade 40mm bore for cable protection including all fittings laid in trenches or fixed on pole with suitable clamps, complete all as specified and as directed.
M/s B.M. Enterprise
Ms Jahnabi Construction
M/s Hrishikesh Das
m/s dip contruction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .