Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.7 L+₹49,097 (6.78%)Rejected-Finance NOT FOUND | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹8.7 L+₹1.4 L (20.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹9.6 L+₹2.3 L (32.0%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹10.1 L+₹2.9 L (40.1%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
16 May 2024, 6:00 pmClosed
GE (AF) SIRSA
GE (AF) SIRSA, HARYANA-125055
REPAIR/MAINT OF INTERNAL ELECTRIFICATION SYSTEM INCLUDING LIGHT FITTINGS SUB MAIN WIRING MCB DB ETC TO OTM ACCN AT DOMESTIC AND TECHNICAL AREA AT AF STN SIRSA
2024_MES_651184_1
GE/SRA/T-15/2024-25
Open Tender
Miscellaneous Works
Item Rate
240 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹50,000
Yes
30 May 2024
25 Apr 2024
17 May 2024
25 Apr 2024
16 May 2024
4 May 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. (except light fittings), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down/out unserviceable Wires only from the existing Sub-main Wiring of any type and any description, without disturbing Existing Conduit, complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.20 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit)
All as per item No. 04 above but for One 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
-Ditto- as item No 04 but for One 5 Pin Socket Outlet 6 Amps on the same board, complete all as specified and as directed. (concealed type point wiring in existing conduit).
All as per item No. 04 above but for one light point controlled by two 2-way switches complete all as specified and directed (concealed type point wiring in existing conduit).
All as per item No. 04 above but using 2.50 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.50 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring in existing conduit).
All as per item No. 08 above but using 4.0 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 20 Amp socket outlet controlled by one switch on independent board with and incl 4.0 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring in existing conduit).
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 20mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing Sunk Mild Steel Pressed Terminal Box (1.20mm thick) of suitable size (as required) duly painted with Red Oxide Metal Primer and cover plate and frame for mounting MODULAR TYPE Switches, Sockets, Fan Regulators, etc. and Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP incl finishing good disturbed surfaces complete all as specified and as directed.
NOTES :- (1) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (2) Quoted rate shall be deemed to be inclusive of the cost of sheet metal terminal box and Modular cover plate with frame as per required size/no. of modules. Quoted rate of point wiring shall be deemed to include for the cost of pressed steel terminal box, modular cover plate and frame as per makes specified in tender. (3) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage. (4) On completion of the wiring work, the contractor shall fill and finish the chases with cement mortar 1:6, apply 2 mm thick wall putty for smooth finish and finish with two coats of acrylic distemper as per existing shade over the conduit layout. Rate quoted by the contractor shall be deemed to include for the above aspect and no claim shall be entertained at a later stage.
All as per item No 10 here-in-before but for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 10 here-in-before but for one 5 pin 5/6 amp socket out let point in the same switch board of light points, fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No. 10 above but for one light point controlled by two 2-way switches (Modular Type) complete all as specified and directed.
All as per item No 10 here-in-before but with 2.50 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 2.50 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 20mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing Sunk Mild Steel Pressed Terminal Box (1.20mm thick) of suitable size duly painted with Red Oxide Metal Primer with cover plate and frame (as per Site requirement) for mounting MODULAR TYPE Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, incl finishing good disturbed surfaces complete all as specified and as directed.
All as per item No 14 here-in-before but with 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 20mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing Sunk Mild Steel Pressed Terminal Box (1.20mm thick) of suitable size duly painted with Red Oxide Metal Primer with cover plate and frame (as per Site requirement) for mounting MODULAR TYPE Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, incl finishing good disturbed surfaces complete all as specified and as directed.
S&F Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in PVC CONDUIT complete all as specified and as directed. (NOTE: The wires shall be provided in existing conduit. Quoted rates shall be exclusive of the cost of conduits. Three runs of wire shall be considered as one unit)
All as per item No 16 above, but sub main wiring with 2 runs of 6.0 sqmm wires for and one run of 6 sqmm wire for earth continityalong with the Wiring drawn in PVC CONDUIT complete all as specified and as directed. (NOTE: The wires shall be provided in existing conduit. Quoted rates shall be exclusive of the cost of conduits. Three runs of wire shall be considered as one unit)
PIANO SWITCH, 5/6 AMPS, SINGLE POLE, ONE WAY
S & F new Switch piano, flush type, 5/6 Amps
S&F in repairs new piano switch, 5/6 amps flush type (incl taking down existing switch)
PIANO SWITCH, 5/6 AMPS, SINGLE POLE, TWO WAY
S & F new Switch piano, flush type, 5/6 Amps, 2 way
S&F in repairs new piano switch, flush type, 5/6 Amps 2 way (incl taking down existing switch)
PIANO SWITCH, 15/16 AMPS, SINGLE POLE, ONE WAY
S & F new Switch piano, flush type, 15/16 Amps
S&F in repairs new piano switch, flush type, 15/16 Amps (incl taking down existing switch)
SOCKET OUTLET, 5 PIN, 5/6 AMPS,
S & F new socket outlet, flush type, 5/6 Amps
S&F in repairs new socket outlet, flush type 5/6 Amps (incl taking down existing outlet)
SOCKET OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS,
S & F new socket outlet, flush type with indicator lamp, 6/16 Amps
S&F in repairs new socket outlet, flush type with indicator lamp, 6/16 Amps (incl taking down existing outlet)
SWITCH SOCKET COMBINATION OUTLET, 3/5 PIN, 5/6 AMPS,
S&F new switch socket combination outlet, flush type, 5/6 Amps
S&F in repairs new switch socket combination outlet, flush type 5/6 Amps (incl taking down existing outlet)
SWITCH SOCKET COMBINATION OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS,
S & F new switch socket combination outlet, flush type with indicator lamp, 6/16 Amps
S&F in repairs new switch socket combination outlet, flush type with indicator lamp, 6/6 Amps (incl taking down existing outlet)
BELL PUSH, 5/6 AMPS, 240 VOLTS
S&F new Bell push, flush type, 5/6 Amps
S&F in repairs, Bell push, flush type 5/6 Amps (incl taking down existing fitting)
CALL BELL/BUZZER, AC 230/240 VOLTS, SINGLE POLE
S&F new Call bell, musical type
S&F new Call bell, ding dong type
S&F in repairs Call bell, musical type (incl taking down existing fitting)
S&F in repairs call bell, ding dong type (incl taking down existing fitting)
CEILING ROSE, THREE TERMINALS, 240 VOLTS
S&F new Ceiling rose, surface type
S&F in repairs, ceiling rose, surface type (incl taking down existing fitting)
FAN REGULATOR, STEPPED TYPE, 5 SPEED CONTROL, 230/240 VOLTS
S&F Fan Regulator, 5 Step, Socket type, 100 watt
S&F Fan Regulator, 5 Step, Piano type, 100 watt,
S&F in repair Fan Regulator, 5 Step, Socket type, 100 watt, (incl taking down existing regulator)
S&F in repair Fan Regulator, 5 Step, Piano type, 100 watt, (incl taking down existing regulator)
LAMP HOLDER, PVC/POLYCARBONATE BODY
S&F lamp holder with back plate suitable for batten fittings or to be mounted on walls
S&F in repairs lamp holder with back plate suitable for batten fittings (incl taking down existing holder)
MODULAR SWITCH, 5/6 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 6 A, 1 module
S&F in repairs new modular switch, 5/6 Amps, 1 module (incl taking down existing switch)
MODULAR SWITCH, 5/6 AMPS, 1 MODULE, TWO WAY
S & F Modular Switch 2 way 16 A, 1 module
S&F in repairs new modular switch, 16 Amps, 1 module (incl taking down existing switch)
MODULAR SWITCH, 16 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 16 A, 1 module
S&F in repairs new modular switch, 16 Amps, 1 module (incl taking down existing switch)
MODULAR SOCKET, 6 AMPS, 2 MODULE
S & F Modular Socket 6 A, 2/3 pin combined 2 module
S&F in repairs new modular socket, 6 Amps, 2 module (incl taking down existing socket)
MODULAR SOCKET, 16 AMPS, 2 MODULE
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module
S&F in repairs new modular socket, 6 A/ 16 A, 2/3 pin combined 2 module (incl taking down existing socket)
MODULAR FAN REGULATOR
S&F Modular Fan step regulator, 120 watt, 2 module, stepped type
S&F in repairs new modular Fan step regulator, 120 watt, 2 module (incl taking down existing regulator)
MODULAR BELL PUSH
S & F Modular Bell push 6A, 2 module
S&F in repairs new modular Bell push 6A, 1 module (incl taking down existing switch)
Supplying, assembling and fixing in repairs on wall, Modular MCB protected Power Unit comprising of following accessories :- (i) Powder Coated Steel terminal box, 06 module - 01 No (ii) Modular Cover Plate with Frame, 06 Module - 01 No (iii) 16 Amps 3 Pin Modular Socket, 02 module - 01 No (iv) 16 Amps Plug Top - 01 No (v) 25 Amps Motor Starter, 02 Module - 01 No (vi) 25 Amps, Single pole Mini MCB, 10kA - 01 No
Supplying, assembling and fixing modular AC power unit comprising of 01 No 16 Amps socket and 01 No 32 Amps SP MCB, 3 modules along with GI metallic flush box, cover plate and frame duly concealed in wall incl dismantling of existing power unit complete all as specified and directed. NOTE: Quoted rate shall be deemed to include for the cost of MCB, socket, GI flush box, cover plate & frame. Concealed conduit wiring shall be measured seperately.
S&F in repairs 32 Amps modular motor starter with cover plate & frame, 2 modules along with GI metallic flush box duly concealed in wall complete all as specified and directed. NOTE: Quoted rate shall be deemed to include for the cost of cover plate & frame and GI flush box alongwith starter. Concealed conduit wiring shall be measured seperately.
S&F in repair Hylem sheet for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 200 x 150 x 50 mm including cutting for mounting of switches and sockets, complete all as specified and as directed. (NOTE: This item shall not be measured for new point wiring)
All as per Item No 40 above, but with 3 mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm complete. (NOTE: This item shall not be measured for new point wiring)
All as per item No 40 above, but with 3 mm thick plastic laminated sheet cover of size 350 x 300 x 50 mm complete. (NOTE: This item shall not be measured for new point wiring)
MODULAR TYPE WHITE/IVORY COVER PLATE WITH FRAME
S&F in repairs Modular type White cover plate with frame 1/2 module (incl taking down existing cover plate & frame) (NOTE: This item shall be measured only for replacement of existing switch board)
-ditto- but for Modular type White cover plate with frame 3 module
-ditto- but for Modular type White cover plate with frame 4 module
-ditto- but for Modular type White cover plate with frame 6 module
-ditto- but for Modular type White cover plate with frame 8 module
-ditto- but for Modular type White cover plate with frame 10 module
-ditto- but for Modular type White cover plate with frame 12 module
MODULAR TYPE METAL TERMINAL BOX
S&F in repairs GI Terminal Box, 1.20 mm thick, suitable for modular switches, 1/2 module (incl taking down existing box) (NOTE: This item shall be measured only for replacement of existing switch board)
-ditto- but for GI Terminal Box for 3 module
-ditto- but for GI Terminal Box for 4 module
-ditto- but for GI Terminal Box for 6 module
-ditto- but for GI Terminal Box for 8 module
-ditto- but for GI Terminal Box for 10 module
-ditto- but for GI Terminal Box for 12 module
S&F in repairs surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, 110 lumen/watt, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and incl connecting up with three core flexible copper wire of suitable size complete all as specified and directed.
-ditto- as per Item No. 45 but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
-ditto- as per Item No. 45 but of 1 X 05 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
S&F in repairs LED Bulkhead fitting 09/10 watt, with IP65 degree of protection and with impact resistance of IK-08, mounted on wall /ceiling connected with insulated unsheathed flexible copper wire of suitable size complete all as specified and directed.
S&F in repairs recess mounted LED luminaire, of size 300 mm x 1200 mm, 110 lumen/watt, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED and incl all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed.
All as per Item No. 49 above, but 36 Watt recess mounted LED luminaire, of size 600 mm x 600 mm complete
All as per Item No. 49 above, but 36 Watt surface mounted LED luminaire, of size 600 mm x 600 mm complete
S&F in repairs recess mounted LED flat panel luminaire, 100 lumen/watt, suitable for 300 mm x 300 mm snap grid ceiling, , in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 15 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed.
-ditto- as per Item No. 52 but surface mounted LED flat panel type of capacity 15 Watt
S&F in repairs recess mounted slim-fit downlighter, 100 lumen/watt, round or square, having glare free frosted diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 15 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed.
-ditto- as per Item No. 54 but recess mounted LED downlighter of capacity 12 Watt
-ditto- as per Item No. 54 but recess mounted LED downlighter of capacity 06 Watt
-ditto- as per Item No. 54 but surface mounted LED downlighter of capacity 15 Watt
-ditto- as per Item No. 54 but surface mounted LED downlighter of capacity 12 Watt
-ditto- as per Item No. 54 but surface mounted LED downlighter of capacity 06 Watt
S&F in repairs wall light/fixture light made up of high grade engineering plastic material suitable for 9 W LED lamp B22 base withn complete all type of fittings complte all as required and directed. (MAKE: HAVELLS (FLORET) Cat No : LHFHCHE1TL1W020 or equivalent model in other makes specified in tender)
S&F in repairs wall light/fixture, stainless Steel brushed nickle finish fixture with opal Glass diffuser suitable for 9 watt LED lamp B22 Base complete all type of fittings complte all as required and directed. (MAKE- HAVELLS (Florentine WL 1LS B22 SS) Cat Part No-LHFOAJE1TZ1I060 or equivalent model in other makes specified in tender)
S&F in repair LED post top luminiare, 25 watt, with die cast amuninium spigot, spun aluminium powder coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver complete all as specified an directed. (Make : BAJAJ, Cat No: BGCTN 25W LED WW / HALONIX, Cat No: HLPT-04-25CW / HAVELLS, Model: RUBY / ORIENT, Cat No: OSL-MARFICPT025W or equivalent model in other makes specified in tender) ) NOTE: Wire for connection of luminaire, if replaced, shall be measured and paid seperately.
S&F in repair PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 3 core, 1.50 sqmm, 1100 Volt, conforming to IS 694 all as specified and directed
S&F DB, VTPN, 4 way, vertical type, IP 43 protection, double door, 415 volts with provision for MCCB as incomer and MCB as outgoing and electrically connecting up complete all as specified and directed.
S&F TPN DB, IP 43 protection, double door, 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed.
S&F SPN DB, IP 43 protection, double door, 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed.
S&F Double Door, Sheet Metal Enclosure for DBs, for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed.
S&F Sheet Metal Enclosure, Single Pole with a 2-Pin and Earth Plug and Socket with and including 1 No. MCB Single Pole, 32 Amp, 240 Volt and Connecting up complete all as specified and as directed.
NOTE FOR ITEM NO. 64 to 68 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured and paid seperately. (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
S&F MCCB, 4 pole, 100 Amps, 16 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed.
S&F MCB, 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'C' series, SPN, 40 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
Supply only saddle/PVC gitti for fixing of PVC electrical conduit 25 mm dia (in packet of 100) complete all as specified and as directed.
Supply only electrical conduit PVC pipe 25 mm MMS type of length 03 Mtr, medium grade complete all as specified and directed.
Supply only electrical conduit PVC Casing caping pipe 25 mm MMS type of length 03 Mtr, medium grade complete all as specified and directed.
Supply, laying, jointing and testing, fixing to wall using clamps/ pole/ floor or in air or passing through pipes/ducts/road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened, PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 4 core 25 sqmm confirming to IS-7098 Part-1 and its latest amendments including taking down existing unserviceable cable complete all as specified and as directed by Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
shiv shanker enterprises
YOGINDER KUMAR GUPTA AND COMPANY
M/S GOYAL CONSTRUCTIONS
NISHTHA BUILDERS
M/s Satguru Traders
M/s Shree Bala Ji Construction Company
SHIVAM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .