Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KAPURTHALA
GE KAPURTHALA
Repair/Replacement/maintenance of Street/Security lights and allied works at Mil Stn Suranussi under GE Kapurthala
2020_MES_347295_1
GE KPT-06/2020-21
Open Tender
Civil Works
Item Rate
300 days
KAPURTHALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE KAPURTHALA
₹90,000
Yes
6 Jul 2020
27 May 2020
3 Jul 2020
27 May 2020
1 Jul 2020
12 Jun 2020
60 days
Amount
Attending and rectification / redressal of day to day complaints of street / security light (HPSV,MH,Flourescent tube light, T-5, LED , Flood light fittings etc. of any make) complaints received through telephone or in person and rectification of defects fixed on street light poles 9/11 m long, building walls, roof by bringing down the fittings on grond or in position including replacement of lamp, ignitor, flexible wire, reflector etc including cleaning of glass/acrylic cover for clear reflection of light, replacement of old unserviceable street light fittings with new fittings etc as required to make the light fitting functional (Vehicle, ladder, tools and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement.Note : (i) Disconnecting electrical connections, opening up for inspection and making joint inventories of defects and spaces to be replaced, re-fixing old serviceable spares and fixing new spares in item replacement reasonbling, installing and fixing against in position testing and commissioning equipment of appliances.(i) Light fitting, ballast, starter, ignitor, diffuser, cable, flexible wire and LED drive etc if required to be replaced in repair shall be measured and paid separetely under relevant item of this BOQ as a supply only. Note - The labour element for fixing of materials of Sch 'A' item No 6 to 23 is deemed to be included in Sch 'A' item No 1 or 2.
(ii) Contractor shall deploy sufficient number of electricians and helpers as directed by Engineer-in-charge to attend the complaints and reactify the same within 24 hours of receipt of complaints, failing which a penalty of Rs. 300.00 per complaint shall be imposed on contractor besides payment of complaint shall not be allowed. Attendence record of electrician and helpers shall be maintained jointly by the Engineer-in-Charge and Contractor as well. A pucca bound maintainence register shall also be maintained by the Engineer-in-Charge and Contractor as well. (iii) Contractor's representative shall collect the complaints at complaint cell at 8.30 AM to 9.00 AM from JE E/M and report after completion of rectification of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Old retrived material shall be deposited in AGE E/M yard and will be given to contractor after completion of contract.
(v) Contractor will deposit new material to Engineer in charge for acceptance and then material will be issued by JE E/M daily based on assesment of complaints. (vi) Supply only spares (in replacement) shall be measured and paid for separately under respective items of Schedule 'A'. The unit rate quoted by the contractor in this item shall included for the cost of fixing all types of spares, re-fixing, minor parts such as bolts nuts, washers etc. Purchase vouchers shall be submitted by the contractor to Engineer-in-Charge. (vii) Each complaint shall be entered in MB mentioning complaint No, date, location, defects detected, work executed, spares replaced etc in a tabular form in the enlarged MB. (viii) Users signature shall be obtained in token of complete redressal / rectification of a complaint. (ix) Cost of minor repairs, replacement of petty items such as nuts, bolts, washers, screws etc.
All as per item No. 01 but for 16 metres height high mast lights.
Supply, fix, connect and test in replacement; LED street light fitting 30 Watts (or above watt) IP 66 with PDC Aluminium body and toughened glass visor fitted in frame, separate driver compartment provided, secondary optical lens for superior light distribution efficiency >95 Lm/W, CCT5700K IP65, input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make : Polycab Cat Part No PCGLS 01 30 Product code PUB0502004 and C&S electric Cat part No LTESS 12 X 2.5 HPLED/LS Product Code INDUS/30W/LS (Model Indus series) or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Supply, fix, connect and test in replacement; LED street light fitting 45 Watts (or above watt) IP 66 with PDC Aluminium body and toughened glass visor fitted in frame, separate driver compartment provided, secondary optical lens for superior light distribution efficiency >95 Lm/W, CCT5700K IP-65, input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make : Polycab Cat Part No PCGLS 45 Product code PUB0501004 and C&S electric Cat part No LTESS 18 X 2.5 HPLED/LS Product Code INDUS/45W/LS (Model Indus series) or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Supply, fix, connect and test in replacement; LED flood light fitting 60 Watts capacity having following specification fixture should be having pressure die cast alluminium IP 66 with extended alluminium heat sink with pressure die cast aluminium end caps with seprate control gear unit (b) Fixture should be having PMMA optics for uniform distribution (c) Input voltage 110 V to 300 V AC (d) Surge protection of 5 KV (d) Mechanical protection IK 05 (e) Power factor > 0.95 (f) Lumen/watt 105 Lumen/watt (g) THD > 10% (h) Fixture front cover with polycarbonate encapsulated (j) Fixture having fuse protection short circuit protection and over voltage protection cutt off voltage 110- 310 V having Auto shutdown mode (k) Fixture should be approved from Govt of India ministry of science & Technology (m) Brand name should be enclosed on fixture (n) LED flood light must be having discute LED Structure Make :Bajaj cat part NoPAR0201004 PCGLF 02 60 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Supply only flourescent tube rod 36/40 Watts complete all as specified and as directed by Engineer-in-charge.
Supply only open construction ballast suitable for 240 volts 50 Hz 1 x 70 Watts SON/MH Lamp. Make : Havells cat part No LHBW08170036 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only open construction ballast suitable for 240 volts 50 Hz 1 x 150 Watts SON/MH Lamp. Make : Havells cat part No LHBW08115036 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply onlyopen construction ballast suitable for 240 volts 50 Hz 1 x 250 Watts SON/MH Lamp. Make : Havells cat part No LHBW08125036 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only electronic ballast with wire suitable for 1 x 36 Watts FTL sleek Make Havells Cat part No LHBF18002015 or equivalent in Bajaj/CG/Philps/C&S c or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only electronic ballast 2 x 14 Watts with wire suitable for 2 x 14 WattsT5 FTL. Make Havells cat part No LHBT01214040 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only metal halide single ended clear tubular lamps (MH DE) suitable for 150 Wattsenclosed fixture. Make : Havells catt part No LHSM12015499 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only metal halide double ended clear tubular lamps (MH DE) suitable for 150 Wattsenclosed fixture. Make : Havells catt part No LHSM12015499 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only metal halide single ended clear tubular lamps (MH DE) suitable for 250 Watts enclosed fixture. Make : Havells cat part No LHSM12025499 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only high pressure sodium vapour tubular clear lamp (SON-T) suiable for 70 Watts Make : Havells cat part No LHSS16107099 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only high pressure sodium vapour tubular clear lamp (SON-T) suiable for 150 Watts Make : Havells cat part No LHSS16015099 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only high pressure sodium vapour tubular clear lamp (SON-T) suiable for 250 WattsMake : Havells cat part No LHSS16025099 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only T-5 rod 14 Watts 6500 K, suitable to operate on 240 volts. Make Havells cat part No LHST27114699 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only Ignitors suitable for 70 - 400 Watts SON & MH Lamps short distance type Make Havells Cat part No LHGEAJENNNA1000 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only MCB SP, 32 to 63 Amp 240 Volts, 20 KA, B-Series, in DB / Junction Box or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply only contactor ML-2 with 415 Volt coil AC, 03 rating 32 A, 400 V Cat Part No SS90701 of Make LT complete all as specified and as directed by Engineer-in-Charge.
Supply only constant current LED driver Bajaj Cat Part BGD 70065 Y-45W or equivalent in Appendix 'B' for relevant lights complete all as specified and as directed by Engineer-in-Charge.
Supply only 1100 Volts grade heavy duty cable 3 core 1.5 Sqmm PVC insulated copper stranded conductor passing through and including 20 mm bore PVC pipe for connection pupose of street light fitting from DB to street light fitting by cutting with the cutter and making good in CM 1:3 complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement ; Time light distribution board analog Time switch 230 volt three phase of 16 Amps rating with contactor fixed inside steel enclosure box and fixed to pole/LT Panel including clamps, nuts, bolts and washers etc complete all as specified and directed.Make Indo-Asian cat part No TL016ABO or equivalent in Legrand/Scheneider or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply and fix in replacement; MCCB 250 Amp, 4 pole, 35 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Standard CAT Part No ISLCNF 0250 (Frame size SKB-3) or equivalent CAT part of make Havell's/ Siemen's/ L & T)
Supply and fix in replacement; MCCB 350 Amp 04 pole 415 volt 50 HZ breaking capacity 35 KA with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Havells CAT Part No IHLCNF0315 (Frame size SKB-4) or equivalent CAT part of make Standard/Siemen's/L & T) or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply and fix in replacement; double door bus bar 4 way 200 amp horizental type suitable size of legs including PCC work complete all as specified and directed. Make : Standard/L&T/Siemen's/INDOASIAN or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-charge.
Supply and fix in replacement; 20 mm bore galvanised iron medium grade bracket 1.50 m length 'L' shape suitable for fixing of street light fitting on pole complete with 2 Nos clamps, Nuts and bolts of suitable size complete all as specified and directed.
Supply and fix in replacement; control box for street/security light made of 3mm thick MS Sheet (CRCA) comprising of MCB 16 Amps -01 No SP, bus bar of 50 Amps rating aluminium for phase and netural on porcelain based insulators with locking arrangement fixed to pole with MS clamp of size 20x3 mm, nuts, bolts and washers complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceable ACSR conductor of any type & size including insulators on LT poles complete all as specified and as directed by Engineer-in-Charge.
Supply and fix aluminium conductor steel reinforced for overhead lines on poles including aluminium binding wire 14 SWG jumpers, lines tapes etc complete all as specified and directed by Engineer in Charge. of size weasel and mink. Note : for payment purpose weight of ACSR conductor shall be considered. Note : for payment purpose weight of ACSR conductor shall be considered.
Supply, stretch and fix in repacement; continuos earth wire 4 mm dia galvanised steel wire including galvanised mild steel binding wire 14 SWG complete all as specified and as directed by Engineer-in-Charge. Note : for payment purpose weight of 4 mm dia galvamised wire only shall be taken and clamps, hooks shall be measured and paid separetley.
Supply and fix in replacement; loop type insulator, vitreous porcelain white, brown or green with over all size 65x90 mm with clearance dia of hole 16mm complete all as specified and directed by Engineer in Charge.
Supply and fix in replacement, shackle type porcelain vitreous white, green or brown insulators for working pressure 1100 volts, 90 mm dia, 75 mm height including galvanised MS straps, washers, insulator bolts, washers & nuts complete all as specified and as directed by Engineer-in-Charge. Make : Mysore/Bengal Potteries/WS Madras or equivalent in makes indicated in Appendix 'B' of Particular Specifications
Supply and fix in replacement; pin type insulator porcelain white brown or green including one galvanized mild steel spindle two galvanised iron washer and one galvanised iron nuts 100 mm height 65 mm dia for 1100 volts grade complete all as specified and as directed by Engineer-in-Charge.
Supply, fabricate and fix in replacement; cross arms (anytype) supports, bracing, stiffeners, clamps etc fabricated from structural steel section including drilling of holes nuts, bolts, washers etc including painting with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
Supply, erecting intruely vertically position in replacement; concrete pole 9 Mtr long of size 102 mm x 172 mm at top and 102mmx279 mm at bottom class 10 complete and re-fixing of overhead conductor on pole including painting of pole up to 1.5m high from PCC coping in black & white strip each of 30mm high with two coats of synthetic enamel paint complete all as specified and directed (Excavation/ earthwork/PCC work shall be measured & paid separatelly) including taking out existing unserviceable pole & removing from site complete all as specified and directed by Engineer-in-charge. (Excavation/ earthwork/PCC work shall be measured & paid separatelly).
Material and labour for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundation bed and around the pole as mass concrete including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.
Material and labour for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregates as in foundation of stays and coping of poles etc complete all as specified and directed by Engineer in Charge.
Supply and fix in replacement; stay assembly comprising of GI stay bow 14 mm dia, 40 cm long ( over all) galvanised stay rod 20 mm dia 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30 cm x 30 cm x 6 mm thick 2 Nos of thimbles, MS clamps made out of 50 mm x 6 mm flat iron complete including stay wire 7/8 SWG complete all as directed including necessary excavation, earth work, PCC and loop insulator all as shown in electrical plate No.1 of SSR-2009 Part-I.(PCC, excavation, loop type insulator,stay clamps,stay wire shall be measured and paid for separately under appropriate items of Sch 'A')
Supply and fix in replacement; stay strand of size 7/4 mm made of galvanised steel wire complete all as specified and directed.
Material and labour for boring hole under the road / pavement / hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting GI pipe of 100/80 mm bore not less than one meter below ground level complete all as specified and directed.
Excavating in trenches in soft/loose soil not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation of poles/ stays/ laying of cables etc and getting out including trimming of sides of trenchescomplete all as specified and directed by Engineer in Charge.
Returning, filling the soft / loose soil including spreading, leveling watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed by Engineer in Charge.
Removing of surplus excavated soil to a distance not exceeding 50m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer in Charge.
Supply, lay, joint, test and commission in replacement; under ground XLPE/PVC armoured heavy duty electric cable insulated and PVC sheathed LT with stranded aluminium conductor 1100 vols grade cross sectional area 10 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, lay, joint, test and commission in replacement; under ground XLPE/PVC armoured heavy duty electric cable insulated and PVC sheathed LT with stranded aluminium conductor 1100 vols grade cross sectional area 16 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, lay, joint, test and commission in replacement; under ground XLPE/PVC armoured heavy duty electric cable insulated and PVC sheathed LT with stranded aluminium conductor 1100 vols grade cross sectional area 6 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Material and labour for sand cushioning with sand to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable and punned down to 10cm complete all as specified and directed by Engineer in Charge. Note : 18 cm thickness shall be reckoned for the purpose of measurement and payment.
Material and labour for brick protection using old size sub class ‘B’ new bricks, laid flat, laid dry with width equal to length of brick, laid across the length of cable complete all as specified and directed by Engineer in Charge.
All as per ser item No 50 here-in-before but lay only (old serviceable bricks obtained from taking out of cable shall be reused).
Supply and fix in replacement; 80mm bore galvanised iron pipe light grade for cable protection fixed to pole/along wall/floor/under road etc complete all as specified and directed. Note : Clamps nuts & bolts etc shall be measured and paid for separately under appropriate items of sch 'A'Note : Clamps nuts & bolts etc shall be measured and paid for separately under appropriate items of sch 'A'
Material and labour for preparation of old painted surface of PCC LT poles and applying two coats of synthetic enamel paint in alteranate black and white strips of 30 cm each up to 1.5 mtr height from top of PCC coping and numbering of poles complete all as specified and directed.
Labour only for cutting/pruning of tree branches 1.5 m all around the LT overhead lines of span n.exc 70 m and around the pole obstruction the overhead line & removing the branches to distance n.exc 50 m to be the entire satisfaction of Engineer-in-charge comlete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.
Earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to galvanized earth lead wire 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.
KAMAL AGGARWAL
DUGGAL CONSTRUCTION CO
UNITED ENGINEERING CORPORATION
J K AND COMPANY
AGGARWAL ENGINEERING CO
R K ENTERPRISES
SUNRISE ENGINEERS AND CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .