Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹20.8 L+₹11,919.40 (0.58%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹25.7 L+₹5.1 L (24.6%)Rejected-Finance SAVITRI COMPLEX JIWAJI CHOWK LASHKAR GWALIOR MP 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹26.3 L+₹5.7 L (27.5%)Rejected-Finance RAVI KIRAN MARKET JIWAJI CHOWK BADA LASHKAR GWALIOR M P 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | L4 | Rejected-Finance Rejected | |
| 5 | L5₹28.6 L+₹7.9 L (38.2%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹25.8 L
EMD Value
₹51,600
Closing Date
17 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA GWALIOR
GE AF TA GWALIOR-20
PROVN OF E/M RELATED CERTAIN MINOR WORKS, MAJOR REVENUE WORK AND LBW WORKS IN TECH AREA AT AF STN GWALIOR
2021_MES_416862_1
8900/1259/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF TA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TA GWALIOR
₹51,600
Yes
17 Mar 2021
28 Jan 2021
20 Feb 2021
28 Jan 2021
17 Feb 2021
10 Feb 2021
60 days
Amount
Supplying ,laying, and testing LT cable XLPE insulated, screened, PVC bedded, galvanised steel strip of wire armoured electric power cable (heavy duty) 1100V grade with standard aluminum conductor cable of size 10 Sqmm 4 core, laid in trenches/ducts complete all as specified and directed Make :- Havells/Plaza/Polycab/Finolex NOTE : (i) Excavation and earth work, sand cushioning shall be measured and paid under relevant items.
Supplying ,laying, jointing and testing XLPE insulated,armoured, heavy duty, standard aluminum conductor cable of size 95 Sqmm 3.5 core 1100 volts grade, laid in trenches/ducts, fixed to walls etc complete all as specified and directed Make :- Havells/Plaza/Polycab/Finolex NOTE : (i) Excavation and earth work, sand cushioning shall be measured and paid under relevant items.
Supply, laying & connecteing cable 1100 volts grade, stranded aluminium conductor, screened, XLPE insulated, armoured shieled and PVC sheathed cable of size 25 Sqmm, 3.5 Core conforming to IS 7098 (Part-I) amended upto date complete all as specified and directed. Make :- Havells/Plaza/Polycab/Finolex NOTE : (i) Excavation and earth work, sand cushioning shall be measured and paid under relevant items.
Disconnecting, dismentling and taking out old existing underground air field lighting cable of any description and in any position from the trenches/ducts with protection pipe etc if any complete all as specifiec and directed.
Laying only airfield lighting cable of any description and any size in trenches/duct including connecting jointing and testing etc complete all as specified and directed. Note :- Old retieved cablves received in serviceable condition from taking down shall be used in the work
Supply and fixing epoxy straight through joint suitable for single core cable upto 35 Sqmm, 3.3KV complete all as specified and directed.
Taking down and refixing isolation transformer including tapping the joints with self amargamating high tension insulation tape and setting the direction of light as directed and testing complete.
Excavation in trenches in soft/loose siod n exc 1.5 mtr wide and not exc 1.5 mtr and getting out including forming bottom surface for laying cables/pipes all as specified and directed
Excavation in trenches n exc 1.5 mtr wide and not exc1.5 mtr depth for foundation and laying of cable, erection of RCC poles and getting out in soft /loose, Soft/disintegrated rock/hard rock etc complete all as specified and directed.
Returning filling including spreading watering and well ramming in layer not exceeding 25mm thick complete all as specified and directe by Engr-in-charge.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point.
M&L dry river sand in trenches for cable cushioning & protection including spreading, ramming all as specified and directed.
Supply & Laying precast PCC cable concrete cable cover LV low voltage type -I flat size 250 mm x 150 mm x 40 mm complete
Supply and fixing bus bar box made out of 3.15 mm thick MS sheet, single phase, 2 wire, 230 volts AC supply, outdoor cubical type, dust and vermin proof, floor block mounting type suitable for outdoor applications of size 300mm x 300mm x 200mm depth duly painted with two coats fo synthetic enamelled paint over a coat of red oxide primer, height above ground 500mm and grouted 250 mm below ground, legs of frame shall be grouted in PCC 1:2:4 (size 200X200x200 mm block) including 02 Nos Aluminium bus bars 100 Amps on insulators and 1 No of MCB 16 Amp 10 KA and locking arrangement with steel sliding bolts including connecting cables with suitable lugs complete all as specified and directed.
M & L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Horizontal boring under the road below 1mtr from the road surface and dia of hole not exc 100mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work all as specified and directed.
Supply & laying of double wall coorugated pipe 40mm dia including all fittings and accessories all as directed.
Supply and fixing MCCB, 4 Pole 160A, 25 KA(fixed adjustment/ magnetic type) complete all as specified and directed. Make: Havells/ Legrand/L&T
Supply, install, commissioning and testing of split type, inverter technology, wall mounted Air conditioner of capacity 1.5 TR (4500 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , minimum 5 star rating EER of 3.2 and above complete comprising of following :- Make :- Voltas/Carrier/Daikin/Hitechi/Blue star. (a) Indoor unit, copper coiled with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising . Compressor with motor,. air cooled copper condenser with fan and motor .unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 1.5 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.
Supply, install, commissioning and testing of split type, inverter technology, wall mounted Air conditioner of capacity 2 TR (6500 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , minimum 3 star rating EER of 3.2 and above complete comprising of following :- Make :- Voltas/Carrier/Daikin/LG/Hitechi/Blue star. (a) Indoor unit, copper coiled with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising . Compressor with motor,. air cooled copper condenser with fan and motor .unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 2 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.
Supply, install, commissioning and testing of split type, inverter technology, wall mounted Air conditioner of capacity 2 TR (6000 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , minimum 5 star rating EER of 3.2 and above complete comprising of following :- Make :- Voltas/Carrier/Daikin/Hitechi/Blue star. (a) Indoor unit, copper coiled with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising . Compressor with motor,. air cooled copper condenser with fan and motor .unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 1.5 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.
M & L for sub main wiring with Two RUNS of single core 4 Sq.mm for main wire and one run of single core 4 Sq.mm as earth wire of multi stranded copper conductor FRLS PVC insulated unsheathed cable conforming to IS : 694 drawn through and including concealed in PVC coduit conforming to IS : 9537 ( Part-3) and ISI marked not lass than 25 mm dia and all accessories all conforming to IS specification complete. Make - Havells/Finolex/Polycab
M & L for sub main wiring with Two RUNS of single core 6 Sq.mm for main wire and one run of single core 6 Sq.mm as earth wire of multi stranded copper conductor FRLS PVC insulated unsheathed cable conforming to IS : 694 drawn through and including concealed in PVC coduit conforming to IS : 9537 ( Part-3) and ISI marked not lass than 25 mm dia and all accessories all conforming to IS specification complete. Make - Havells/Finolex/Polycab
Supply and Fixing industrial type plug socket, SPN and earth plug 230V, 32 Amps with steel enclosure and one MCB SP 32 Amps complete all as specified and directed. Make: Havells/Legrand/C&S
Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 150 V to 285 V with output voltage stablized at 200V to 245 V with accuracy of + 2.5% and of capacity 3.0 KVA for AC upto 1.5 Ton complete all as specified and directed Make:- Blue Bird/AE/V-Guard
Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 140 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 2.5% and of capacity 4.0 KVA for AC upto 2 Ton complete all as specified and directed Make:- Blue Bird/ AE/ V-Guard
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required 32 X 6 mm dia copper strip complete all as specified and directed.
M&L for appoxy insulator 1100 volt grade including fixing on wall/RCC pillers/blocks with fasteners and fixing the copper strip on insulator with suitable screw/nuts/bolts etc complete all as specified and direted.
Material and labour for earthing complete with copper plate electrode 600mmx900mmx5mm thick buried directly in ground vertically to a depth not less than 4.7 meter below normal ground level (with to edge of earth plate not less than 3.6 meter below ground level & complete size of earth pit (1.60m x 1.60m x 5.00m) connected to copper strip 32mm x 6mm as main earthing lead by means of tinned copper / brass bolts, nuts, check nuts and washers besides brazing at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to test point, made of phosphorous brongze/gun meter of size 75mmx75mmx25mm dril and screwed including 03 Nos 8mm dia 25mm long hexagonal head screwed, 50mm bore GI medium grade for protection of earth lead from top of plate to test terminal complete, adequate quantity of charcoal dust, magnesium sulphate & common salt in alternate layers of 100mm thick all around the plate, under and above the plate and rerurning, filling of earth spread, levelled, watered and compected to required level, PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast 40mm thick RCC cover of (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate), rainforced with 8mm dia TMT bras 3 Nos both way with 12mm dia MS round bar handle, GI medium watering pipe 25mm bore with funnel and wire mess complete all as specified and directed. Note:- (i) The cost of earth lead and its protection pipe upto and including 7.5 mtrs only from the top of earth electrode are deemed to be included under this item and additional earth lead, if any required at site shall be measured and paid for separately under appropriate item of Schedule 'A'. (ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
M & L for earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below notmal ground level, connected to galvanised earth lead wire 4.0mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI wire protection pipe 25mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete ass as specified and testing on completion complete ass as specified and directed .Note - The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (medium grade) for watering 25mm GI protection pipe (medium grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
Supply , fixing connecting & testing sheet metal enclosures double door, single pole and neutral, 8 way DBs for using MCBs/MCB isolators with having aluminium bus bars suitable for 200Amps rating complete all as specified and directed. Make - Legrand/Havells/L&T
S&F MCB SPN,32 Amps B -Series having breaking capacity 10KA complete all as specified and directed. Make - Legrand/Havells/L&T
S&F MCB single pole 6 to 32 Amps B -Series having breaking capacity 10KA complete all as specified and directed. Make - Legrand/Havells/L&T
S&F MCCB, 4 pole 63 Amps current rating and ultimate breaking capacity Icu=16 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed. Make - Legrand/Havells/L&T
S&F sub main wiring alongwith earth wire (green colour) with single core FRLS PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn with and including concealed /Surface PVC conduit (medium grade) with standard accessories, of the following sizes of cable & dia of conduit complete all as specified and directed:- (a) 2x1.5 Sqmm + 1x1.5 Sqmm earth wire with PVC conduit 20 mm dia Make - Havells/Finolex/Polycab
S&F switch socket combination 2 in 1 , 5A flush type complete all as specified and directed. Make - Havells/Cona/Anchor
Supply,fixing,connecting & testing sheet metal enclosure double door SPN 4 way DB complete all as specified and directed. Make: L&T/Legrand/Havells
S&F sub main wiring alongwith earth wire (green colour) with single core FRLS PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn with and including concealed /Surface PVC conduit (medium grade) with standard accessories, of the following sizes of cable & dia of conduit complete all as specified and directed:- (a) 2x 6 Sqmm + 1x 6 Sqmm earth wire with PVC conduit 20 mm dia Make - Havells/Finolex/Polycab
Supply and fixing MCB/Isolator SPN 40 Amps having current rating 10 KA complete all as specified and directed. Make :- Legrand /Havells/C&S.
Supplying & fixing MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed. Make :- Legrand /Havells/C&S.
S&F sub main wiring alongwith earth wire (green colour) with single core FRLS PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn with and including concealed /Surface PVC conduit (medium grade) with standard accessories, of the following sizes of cable & dia of conduit complete all as specified and directed:- (a) 2x2.5 Sqmm + 1x2.5 Sqmm earth wire with PVC conduit 20 mm dia Make - Havells/Finolex/Polycab
S&F sub main wiring alongwith earth wire (green colour) with single core FRLS PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn with and including concealed /Surface PVC conduit (medium grade) with standard accessories, of the following sizes of cable & dia of conduit complete all as specified and directed:- (a) 2x10 Sqmm + 1x10 Sqmm earth wire with PVC conduit 25 mm dia Make - Havells/Finolex/Polycab
S&F switch socket combination 16A /5 A ,5 in 1 complete all as specified and directed. Make - Havells/Anchor/cona
Supply,fixing,connecting & testing sheet metal enclosure double door SPN 8 way DB complete all as specified and directed. Make - Havells/Legrand/C&S
Supply, fixing, connecting & testing of sheet metal enclosures single pole and neutral with a two pin earth plug and socket complete with one single pole 20 amp MCB complete all as specified and directed. Make :- Legrand/Havells/C&S
M&L for point wiring with 1.5 Sqmm nominal cross sectional area, PVC insulated, FR unsheathed, 1100 volt grade, multistranded single core copper conductor and including PVC casing-capping minimum 25 mm wide with all fittings and accessories such as bends, Tees, Joints etc fixed to wall or ceiling and Recessed PVC or rectangular PVC box closed recessed having 40mm depth ISI marked Make: Presto plastic for fixing of switch etc and provision of 1.5 sqmm nominal cross sectional area, PVC insulated, FR, unsheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly, all metal parts, such as tube light fittings, fan hook, earth terminal of all socket points etc as specified and directed .
(a) One light/fan/bell point controlled by one, one way switch.
All as per item No 47 here in before but point wiring with 1.5 Sqmm cable for 5 Amp socket outlet point on independent board all as specified and directed.
S&F switch socket outlet 5 pin, 5 Amp flush type 230 volts complete all as specified and directed .
S&F switch flush type,single pole 5 Amp, 230 volt complete all as specified and directed. Make: Havells/ Cona/ Anchor
S&F ceiling rose surface Bakelite 65 x 50 mm three terminal complete all as specified and directed .
M&L for electronic regulator step type 240 volt, 50 Hz, suitable for ceiling fan 1200 mm sweep all as specified and directed. Make: Havells/ Legrand/ L&T
Supply and Fixing of Ceiling fan 1200mm sweep in metal body of approved colour including fan blades,hanging rod,clamp etc suitable to operate 240 volts, Single Phase, including electric supply all as specified and directed. Make: Havells/Bajaj/Cromton Greaves.
Supply and Fixing of wall mounted fan 400mm sweep size and outer pack size 2x1, single phase 230/240volts complete all as specified and as directed by the Engr-in-Charge. Make: Havells/Bajaj/Cromton Greaves.
S & F powder coated anodised aluminium door frmae of size (101.6mmx44.5x3), shutter frame of size(44.5x85x3) and clip for fixing glass etc with aluminium snap beading over and including all necessary fittings of approved make complete all as specifed and directed.
S & F Mortice lock, made of brass, with handle vertical type, size 65mm four levers complete all as specified and directed.
S & F rubber beading to aluminium door complete all as specified and directed.
M & L for 5.5mm thick tinted sheet glass ordinary quality and glazing with oil putty or rubber beads as required exc 0.5 sqm in each pane complete all as specified and directed.
S & F solar control film 50mm thick non- reflective type sticked to glass panes as per manufacturer instructions
S & F aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding both of extruded sections of cast aluminium alloy 300mm long complete all as specified and directed.
S & F door closer hydraulically regulated designation No 3 universal type suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed cast iron body complete all as specified and directed.
S & F aluminium curtain rod of 20 mm dia- regal rod complete all as specified and directed.
Supply and fixing PVC flexibale braided pipe of 15mm dia including clamp, socket complete all as specified and directed .
M/S Rakesh Verma
vikas traders
RAVINDRA SALES
M/s Yashika Enterprises
M/S KAPIL CONSTRUCTION CO
SHRI RAM CONSTRUCTION
m/s vikash Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .