Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹8.2 L+₹802 (0.10%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L2 | Rejected-Finance bidder is not L1 | |
| 3 | L3₹8.2 L+₹1,318 (0.16%)Rejected-Finance | L3 | Rejected-Finance bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹16,460
Closing Date
5 Nov 2024, 2:00 pmClosed
Executive Engineer-I,CKHED,PWDte.
Office Of The Executive Engineer, Central Kolkata Health Electrical Division, P.W.Dte. P-5, CIT Road, 2nd Floor, Moulali, Kolkata 700 014.
SITC of Air Conditioning Machine with allied E.I. Work at YOGA , Physiotherapy Unit as well as of PG OPD room and Conference Room at The Calcutta Homoeopathic Medical College and Hospital
2024_WBPWD_752924_1
WBPWD/EE-I/CKHED/eNIT-55/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Calcutta Homoeopathic Medical College and Hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹16,460
P-12, CIT ROAD.KOLKATA-14
11 Apr 2025
18 Sept 2024
11 Nov 2025
18 Sept 2024
24 Nov 2025
24 Sept 2024
23 Sept 2024
Amount
Part-A: AC Installation Work
Supply & Delivery of 230V,1-Ph, 50Hz, 3 star rating, 2.5Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 30000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32, Air Flow/IDU:- 1000CFM, Operating Mode:- Auto,Cool,Fan & Dry Mode, De-humidification:- Yes, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/O General)
Supply & Delivery of 230V,1-Ph, 50Hz, 3 star rating, 2.0Tr. capacity Hi Wall Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 24000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32, Air Flow/IDU:- 800CFM, Operating Mode:- Auto,Cool,Fan & Dry Mode, De-humidification:- Yes, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/O General)
Installation, Testing & Commissioning of Indoor & Outdoor unit of the following capacity concealed type Split Air Conditioners/ Hi wall split after making hole in wall/Ceiling & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant as per the manufacturer specifications, S&F of necessary fixing arrangement for indoor duly painted etc as per direction of the EIC.
2.5 Tr. Concealed Split type
2 Tr. Hi Wall Split type
Supplying fabrication & fixing of 2nos U-Channel (TATA Make) of size (50 mm x 50mm x 6mm thick) for making platform for instalation of outdoor unit incl. drilling 2nos holes in each channel as per site condition & as per direction of EIC. incl. cutting holes into the wall & grouting the same with cement concrete (1:1 %1/2: 3) etc incl. mending as orginal and fabricated with horizontal angle of 25 mm x 25 mm x 6mm including supporting angle 50 mm x50mm x 6mm in each platform in outer edge for transmitting the load centrally through 2Nos (50 mm x50 mm x 6 mm) Angle inserted to the exiting wall The entire structure should be baricated & safe for ODU maintenance Area of the platform is 2Mx1.2M or as per Machine configuration & load with adequate service access as per direction of EIC. (Structural design should be approved by E.I.C.)
Supply and fixing of AI powder coated continuous Grill (Make- Premier, Dynacraft/ EIC approved.)
Supply & Laying of soft drawn Copper pipe line with 0.6 mm or 0.7 mm (min) thick for Liquid Line and Suction Liine between ODU and IDU with fittings, elbows, bends, supports & brackets (Make-Ryoku/Hitachi/Nippon)
Liquid Line 1/4" (6.35mm) Dia or as per manufacturer specification)
Gas Line/Suction Line 5/8" (15.88mm) Dia or as per manufacturer specification)
Supply & Fixing Pipe Insulation of Liquid Line and Suction Liine with 9 mm thick nitrile rubber tube also raping the insulation & copper wire with GKB Gold non adhesive raping tape (Make:- Accoflex/ Armacell/Supreme)
Liquid Line 1/4" (6.35mm) Dia or as per manufacturer specification)
Gas Line/Suction Line 5/8" (15.88mm) Dia or as per manufacturer specification)
Supply and laying 4 core 2.5 sq mm control copper cable (PVC insulated & unshethed,un-armoured) from Condensing Unit to IDU control panel (Make: Gloster/Havells/RR Kable /Finolex/ Polycab)
Supply and laying of Drain Water piping work out of UPVC hard pipes of following sizes incl. nitrile insulation with fiting accessories bends, elbows, tees flanges, tapings, wall sleeves hangers, supports, anchors etc. as required.(Make : Supreme / Astral/ EIC approved).
25 mm dia.
Hiring Charge of Scafolding Arrangements for installation of all the Indoor & Outdoor Units.
Part-B: Electrical Installation Work
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. INCOMING-160 A FP MCCB -1 No, 63A TP MCB-2 Nos,32 A SP MCB- 12 Nos ( (Make:- Legrand/L&T) [Ref.- D-11/15]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Make: Legrand/L&T) [Ref.- D-8/10]
Dismantaling the existing old & damaged cables, old & defunct TPNDB,SPNDB, existing light fittings, plug board etc. after disconnecting the internal connection as required.[N.S]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make:Legrand/L&T) [Ref.- D-10/14]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make: Legrand/L&T) [Ref : D-9/13]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand/L&T) [Ref.- D-5/6]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand/L&T) [Ref.- D-6/7]
6-32A, SPMCB
63A, TPMCB
Supplying and fixing 415V, 160A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make: L&T) [Ref.- D-3/4(a)]
Supply of following size XLPE/PVC Armoured Al. cable (Make:- Finolex/RR Kabel/PolyCab / Gloster/ Havells /KEI) [Ref.- N.S.]
4 core 50 sqmm
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting. [Ref.- F-1/2(C)]
Supply & Fixing of 200x50x1.25mm (18SWG) perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support: With 25x25x3mm angle iron support. [Ref.- D-14/34(a)(ii)]
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below For 4 core [Ref.- F-4/7(c)]
upto 50 sqmm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : [Ref.- F-5/8]
4 core 50 sqmm cable.
S&D of 240V,1-Ph.,50Hz, 18''(450mm) Sweep, full metal body with metal blades Wall Bracket Type Heavy Duty Air-Circular Fan with regulator. [Make:- EPC Tempest or equivalent make]
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. [Ref : C-4/29]
Supply and fixing of 1 phase timer control box for controlling AC machines made following accessories with IP - 42/43 protection with front door locking arrangement with all connection on angel iron frame on wall as per instruction of EIC.
a) 2+10 way size double door SPN MCBDB--1 No. (L&T)
b) 240/415V, AC 32A, 2P Power contactor type MNX22-2P (Make-L&T) - 1 No.
c) Daily & weekly programmable basis Digital Timer Switch, min switching time 1 min, 25 ON/OFF programs- 1 no.(L & T Cat no. - 67DDT0)
d) 240/415V, 40A, DP MCB Isolator (Make:Legrand) 1 no
e) 3 way Auto manual toggle switch--1 no.
f) AC ON/OFF indicator - 1 set
g) ON/OFF push button - 1 set.
h) Interconnection by 2.5 sqmm Cu wire--3 mtr.
Supply & Fixing 240 V, 25 A, Modular type starter (Make:- Legrand/Anchor/ Havells/ North West) with 25A Modular switch type DP MCB (C Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board , cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Ref.- E-19/17]
Supply & Fixing 240V, 25A, 3 pin Modular type plug socket (Make:- Legrand/Anchor/ Havells/ABB), Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make:- Legrand/Anchor/ Havells/ABB), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.. [Ref : E-17/5(a)]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make:- Legrand/Anchor/ Havells/ North West) & necy. Connections. [Ref : E-17/5(b)]
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Make:- Anchor/ Havells) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite / perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Ref : E-6/21]
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make:- Finolex/RR Kabel/PolyCab/ Gloster/ Havells/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points/5A 3 pin flush type plug socket with Piano Key type switch (Make:- Anchor/ Havells) fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/ Perspex (wall matching color) top cover 3 mm thick and incl. 175mm x100mm x 65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. [Ref.- E-14/2(c) & E-15/4(a)]
On Board.
Average run 10 mtr.
S&F of 240V,1-Ph.,50Hz, recessed mounted square shape LED downlight complete with all accessories.
16W, [Make:- Philips Sleek Surface, Cat No.- SM251/261 LED16S 6500 PSU WH or Cromptom PROXIMA-S, Cat No.- CDR-208-15-57-SL-NWH]
S&F of 240V,1-Ph.,50Hz, fully diffused recessed mounted 2'X2' LED light with high transmitive diffuser and complete with all accessories for indoor spaces. [Make:- Philips FullGlow G6, Cat No.- RC380B LED36S-6500 G6 L60W60 PSU OD S1 or Crompton POLARIS (T), Cat No.- TCR-145-36-65-SL-NWH]
S&D of Single LED Tube light fitting along with 1 no. MAS LED (PC body) Tube 1200mm delivering minimum 100 lumen/watt [Make:- Philips, Batten Cat No.- TMC100 1xTLED 13-20w WH & Tube light Cat No.- 18W 865 T8 I – 2100lm or Crompton, Batten Cat. No.- IGP161LT8-16 1 x T8 & Tube light Cat No.- LTB-20-865-(2)].
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [Ref : C-2/17]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make:- RR/Havells/Finolex/ Polycab/Gloster) in 20/25/32mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [Ref.- E-14/1(a)]
4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC [Ref.- E-14/1(b)]
4x196/0.4 (25 sqmm) + 2x126/0.4 (16 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(F-5,9)
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
SKY DECORATIONS PRIVATE LIMITED (BID ID -5738806)
SUPARNA REFRIZARATION (BID ID -5732824)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .