Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAdmitted-Finance | ₹2.6 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical Not Qualified in TC bid evaluationation |
| Sl No | Description | Qty | Unit | M/S PRACHI ELECTRICALS L1 |
|---|---|---|---|---|
| 1.00 | Attending the break down call i/c inspection the Precision Package AC units ,testing the units ,detecting the fault & assessing the list of materials for repairing the units i/c rectification of minor faults ( i.e. without materials ) and restoration of PAC unit etc as reqd. | 6 | Job | 2,725 ₹16,350 |
| 2.00 | Thorough leak testing of cooling coil, condenser coil and pipe line by Nitrogen gas and brazing/ gas welding i/c vacuumization the refrigerant circuit complete as required. | 3 | Job | 6,500 ₹19,500 |
| 3.00 | Supplying & fixing of Condenser Fan motor axial fan with Blade suitable for Uniflair/Schneider make HPAC units, 1350-1380 RPM, suitable for operation on 225-250 watt, 230Volt, 50 Hz AC supply with class F insulation i/c connection and testing etc. as required. ( Make -EBM PAPST, model: S4E450AQ5/REX model-RX4E-450S/HiCool/Spinxx/M&M HARIS/FANS-TECH/Superior make as per approval of the Engineer In Charge.) | 6 | Nos | 10,150 ₹60,900 |
| 4.00 | Supplying and charging / top up of refrigerant gas (R-22) /R -407C/R410A) to the units complete etc. as required. | 45 | Kg | 1,525 ₹68,625 |
| 5.00 | Supplying & fixing of the following items in place of defective one for commissioning of HPAC etc complete as reqd.( Make - Existing make of spare as available in the HPAC ) | - | - | - |
| 5.10 | 32 Amp, 415 volts 3 pole AC3 duty Contactor with 1NO+1NC (Make- Schneider, model- LC1D32, Coil voltage-220/24V AC OR Equivalent. ) | 2 | Nos | 6,300 ₹12,600 |
| 5.20 | 25 Amp, 415 volts 3 pole AC3 duty Contactor with 1NO+1NC (Make- Schneider, model- LC1D25, Coil voltage-220/24V AC OR Equivalent) | 2 | Nos | 4,263 ₹8,526 |
| 5.30 | 18 Amp, 415 volts 3 pole AC3 duty Contactor with 1NO+1NC (Make- Schneider, model- LC1D18, Coil voltage-220/24V AC OR Equivalent) | 2 | Nos | 3,580 ₹7,160 |
| 5.40 | 9 Amp, 415 volts 3 pole AC3 duty Contactor with 1NO+1NC (Make- Schneider, model- LC1D09, Coil voltage-220/24V AC OR Equivalent) | 2 | Nos | 2,900 ₹5,800 |
| 5.50 | Add on Contact block with 1 NO+ 1 NC / 2 NO suitable for 9/16/25/32A 3pole contactor. (Make- Schneider/Equivalent) | 2 | Nos | 850 ₹1,700 |
Updated dates
Tender Value
₹3.0 L
EMD Value
₹5,940
Closing Date
26 Mar 2026, 3:00 pmClosed
Executive Engineer (E), BSNL, Bhubaneswar
Door Sanchar Bhawan, Unit-IX, Bhubaneswar-751022
Repair and Maintenance of HPAC units
2026_BSNL_269264_1
NIT No- 61/BSNL-EDB/ET/2025-26
Open Tender
Electrical Works
365 days
Berhampur
3 documents required · 3 mandatory
₹590
A O (Cash), BSNL, O/o GMTD, Bhubaneswar.
₹5,940
Yes
20 Apr 2026
2 Mar 2026
27 Mar 2026
2 Mar 2026
26 Mar 2026
2 Mar 2026
2 Mar 2026 - 9 Mar 2026
Attending the break down call i/c inspection the Precision Package AC units ,testing the units ,detecting the fault & assessing the list of materials for repairing the units i/c rectification of minor faults ( i.e. without materials ) and restoration of PAC unit etc as reqd.
Thorough leak testing of cooling coil, condenser coil and pipe line by Nitrogen gas and brazing/ gas welding i/c vacuumization the refrigerant circuit complete as required.
Supplying & fixing of Condenser Fan motor axial fan with Blade suitable for Uniflair/Schneider make HPAC units, 1350-1380 RPM, suitable for operation on 225-250 watt, 230Volt, 50 Hz AC supply with class F insulation i/c connection and testing etc. as required. ( Make -EBM PAPST, model: S4E450AQ5/REX model-RX4E-450S/HiCool/Spinxx/M&M HARIS/FANS-TECH/Superior make as per approval of the Engineer In Charge.)
Supplying and charging / top up of refrigerant gas (R-22) /R -407C/R410A) to the units complete etc. as required.
Supplying & fixing of the following items in place of defective one for commissioning of HPAC etc complete as reqd.( Make - Existing make of spare as available in the HPAC )
32 Amp, 415 volts 3 pole AC3 duty Contactor with 1NO+1NC (Make- Schneider, model- LC1D32, Coil voltage-220/24V AC OR Equivalent. )
25 Amp, 415 volts 3 pole AC3 duty Contactor with 1NO+1NC (Make- Schneider, model- LC1D25, Coil voltage-220/24V AC OR Equivalent)
18 Amp, 415 volts 3 pole AC3 duty Contactor with 1NO+1NC (Make- Schneider, model- LC1D18, Coil voltage-220/24V AC OR Equivalent)
9 Amp, 415 volts 3 pole AC3 duty Contactor with 1NO+1NC (Make- Schneider, model- LC1D09, Coil voltage-220/24V AC OR Equivalent)
Add on Contact block with 1 NO+ 1 NC / 2 NO suitable for 9/16/25/32A 3pole contactor. (Make- Schneider/Equivalent)
32/16A/6 Amp 10KA 3pole MCB (Legrand/Schneider/ABB)
Replacement of Liquid line Filter Drier by new one i/c fixing and testing etc, as required. (Make- Danfos, Model-DCL 165 (5/8'/ Equivalent)
Replacement of High Pressure Release Switch by new one i/c fixing, connection and testing etc. as required. (Make: Danfoss-KP1 OR Equivalent: Auto Reset)
Replacement of Low Pressure Release Switch by new one i/c fixing, connection and testing etc. as required. (Make: Danfoss-KP5 OR Equivalent: Manual Reset)
Supply and fixing of Electronic Expansion Valve (EEV) for 7TR High precision AC units made of brass and copper materials,5/8" -7/8"size suitable for Uniflair/Schnieder and Sidwal made HPAC units etc. complete as required. (Make: CAREL, Model: E3V45 AWR00 or equivalent model of repute)
Thorough general servicing, checking, cleaning of evaporator filter /cooling coil and condenser coil of precision PAC units with recommended cleaning liquid and finally cleaning with water, drying etc. i/c re-fixing of cooling coil filters in the existing place etc complete as required.
Repairing of the existing repairable faulty Condenser fan motors i/c replacement of bearings / bush with lathe works, refitting, testing etc. as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_313537.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.97 MB
BOQ_313537.xls
BOQ • 3.67 MB
Download all tender documents and submit your bid