Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC VILL PO MATHUR PS RAMNAGAR DISTT SOUTH 24 PGS PIN 743368 WB | 24 PARAGANAS SOUTH | WEST BENGAL | 743368 | L1 | Accepted-AOC Being L1 bidder. | |
| 2 | L2₹40.1 L+₹1.6 L (4.29%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L2 | Rejected-Finance Rejected due to higher rate than L1 bidder. Amount considered after deduction of schedule of credit mount i.e. Rs. 2075.00 | |
| 3 | L3₹41.8 L+₹3.3 L (8.58%)Rejected-Finance AKASHGANGA SUKANTA MARG MONIRAMPORE BARRACKPORE WEST BENGAL 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-Finance Rejected due to higher rate than L1 bidder. Amount considered after deduction of schedule of credit amount i.e. Rs. 2075.00 | |
| 4 | L4₹43.3 L+₹4.8 L (12.5%)Rejected-Finance 41 BIDHANGARH SOUTH KOLKATA 700066 | KOLKATA | KOLKATA | WEST BENGAL | 700066 | L4 | Rejected-Finance Rejected due to higher rate than L1 bidder. Amount considered after deduction of schedule of credit mount i.e. Rs. 2075.00 |
Tender Value
₹38.7 L
EMD Value
₹77,420
Closing Date
1 Sept 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL, KOLKATA
Garrison Engineer (Central) Kolkata, T-37, Napier Road, Hastings, Kolkata-700022
PROVN OF CAR GARRAGE AT D8 (HASTINGS) INCLUDING PROVN OF HIGHMAST LIGHT AT 1861 LT REGT RASPUNJA AND ADDITION/ ALTERATION OF STORE ROOM/ CONTROL SAMPLE ROOM IN QAE (NAVAL) DEPOT DGQA UNDER GE (CENTRAL) KOLKATA
2021_MES_461598_2
8369
Open Tender
Miscellaneous Works
Item Rate
180 days
Kolkata
As per tender documents
10 documents required · 10 mandatory
₹500
GE CENTRAL KOLKATA
₹77,420
Yes
1 Oct 2021
11 Aug 2021
2 Sept 2021
11 Aug 2021
1 Sept 2021
20 Aug 2021
11 Aug 2021 - 18 Aug 2021
60 days
Amount
Taking down chowkats or frames, exe 1.5 Sqm but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, well , cesspits,manholes,pier holes etc. not exc 10 Sqm on plan and getting out in hard/ dense soil. complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in hard/dense soil complete all as specified and directed.
Removing excavated material of hard/dense soil not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Material and Labour for hardcore of gauge n.exc 63 mm of broken bricks, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and Labour for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Material and Labour for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and directed.
Material and Labour for Plain cement concrete 1:2:4, type B-0, (using 12.5 mm graded stone aggregate) as in benching, coping and brick steps including necessary form work complete all as specified and directed.
Material and Labour RCC Design mix M25 ( Using 20mm graded crushed stone aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Material and Labour RCC Design mix M25 ( Using 20mm graded crushed stone aggregates) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
Material and Labour RCC Design mix M25 ( Using 20mm graded crushed stone aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Material and Labour RCC Design mix M25 ( Using 20mm graded crushed stone aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Material and Labour RCC Design mix M25 ( Using 20mm graded crushed stone aggregates) as in Chajjas complete all as specified and directed.
Materials and Labour precast Cement concrete jallies 35 mm thick type B0 ( 1:2:4, using 12.5mm graded crushed stone aggregates) including necessary form work and set in cement mortar 1:4 complete all as specified and as directed.
Materials and labour Reinforced cement concrete type B1 ( 1:2:4, using 20 mm graded crushed stone aggregates) as in shelves, deck slabs and in similar works complete all as specified and as directed.
Material and Labour Brick work with fly ash pulverized bricks of designation 7.5, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directeded.
Material and Labour Half brick thick Brick work with fly ash pulverized bricks of designation 7.5, straight or curved on plan to any radius, built in cement mortar 1:4 complete all as specified and directeded.
Materials and Labour Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished concrete surfaces complete all as specified and as directed.
Materials and Labour Use and waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular or polygonal in section for rough finished concrete surfaces complete all as specified and as directed.
Materials and Labour Use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed.
Materials and Labour Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished concrete surfaces complete all as specified and as directed.
Materials and Labour Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed.
Supply and fix factory made Solid PVC moulded door shutters 28 to 30mm thick ( stile) with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front Face & 2mm plain colour sheet on back face, complete all as specified and as directed.
Supply and fix Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame including 5 mm thick PVC sheet fillet of width 35mm for wall Paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing including taking down old unserviceable PVC wall lining complete as directed by Engr-in-Charge.
Supply and fix Aluminium door with powder coated anodized aluminium frame of section of size 101.60mm x44.75mm x 2.40mm ( Jindal section 14021) thick, with shutter of style of member of size of 85mm x 44.45mm x 2.00mm ( Jindal Section 19560), top/ bottom rail of member size 114.30mm x 44.45mm x2.15mm ( Jindal section 19574) and lock rail of member size 100mm x 44.45mm x 2.0mm thick ( Jindal section 19564) with rubber gasket and aluminium glazing clip beading and floor spring arrangement, handle aluminium anodized 150mm long ( 01 No), tower bolt 200mm long aluminium anodized (01 No), rollers etc complete all as specified and as directed. Note:- Cost of glazing shall deemed to be included in the rate quoted and cost of floor spring shall be measured and paid separately Under relevent item of these Schedule.
Supply and fix Powder coated aluminium sliding window (three tier) of frame size 92mm x 31.75mm x 1.5mm thickness ( Section No. 20831 of Jindal) and shutter of size 40mm x 18mm x ( 9mm for interlocking legs) x 1.45mm thickness ( Jindal section of 20737), two shutter glazed covering half of span of opening with 5mm thick plain glass including necessary fittings and fixtures and one shutter covering half of opening with stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with steel staples including aluminiumm snap beading incliding aluminium anodized handles 100mm long complete all as directed by the Engineer-in-Charge. Note: Measurement shall be taken clear opening i.e. out to out of window frame as a whole. Cost of of wire cloth and glazing shall deemed to be included in the unit rate quoted by the tenderer.
Supply and fix 4mm thick E-board classic any design plain of size 595 x 595 mm fixed as in ceiling over aluminium grid suspended with GI hooks 6mm dia and clamp to hold GI pipe of the following section:- a) 25 x 25 x 1.5mm(Minimum thick) aluminium angle b) 25 x 25 x 1.5mm (Minimum thick) aluminium cross Tee. c) 25 x 35 x 1.5mm (Minimum thick) aluminium main Tee , including applying two coats of acrylic emulsion distemper after preparation of surface complete all as specified and directed by Engr-in-Charge.
Supply and fix 100mm butt hinges stainless steel complete all as specified and as directed.
Supply and fix 150mm size aluminium handle cast type anodised complete all as directed.
Supply and fix 200mm Aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
Supply and fix 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and as directed.
Material and Labour in repair for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass, other part made of mild steel heavy duty a complete all as specified and as directed.
Supply and fix TMT steel bars 10mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
Supply and fix TMT steel bars 6 to 8mm dia cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
Supply and fix TMT steel bars 6 to 8mm dia for stirrups, spacers and binders and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
Material and Labour for Mild steel framed work such as grills, gratings, gates etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-410-0 Gde E-250 complete all as specified and directed.
Supply and fix 1.00mm thickness of laths Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type complete complete all as specified and as directed.
Supply and fix Ball bearing for rolling shutters complete all as specified & directed by the Engr-in-Charge.
Supply and fix Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified & directed by the Engr-in-Charge.
Material and Labour for 100 mm thick, plain cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
Material and Labour for 75 mm thick, plain cement concrete 1:3:6, type C1 (using 20 mm graded stone aggregate) as in plinth proction and filling the joints with bituminious joint filler in bitumen sand ratio 1:2 complete all as specified and directed.
Material and Labour for 40 mm thick, plain cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in flooring finished even and smooth with using extra cement complete all as specified and directed.
Materials and labour for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in floors etc,set and jointed in neat cement slurry and jointed in white or coloured cement to match etc over 15mm thick screed bed in CM 1:4 including roughening of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust etc and brushing with neat cement slurry 3 Kg per sqm of area and dismantling old unserveable floor and wall tiling including cement mortar bedding complete all as specified and directed.
Materials and labour for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in vertical surfaces such as skirting, dado, riser of steps etc etc,set and jointed in neat cement slurry and jointed in white or coloured cement to match etc over 10mm thick backing course in CM 1:4 and dismantling old unserveable floor and wall tiling including backing course complete all as specified and directed.
Materials and labour 15 to 18mm thick Granite (of any type) work (table rubbed and polished) in Steps, Jambs, Cooking Platform,Dado,Skirting,Floor and like over and including 15mm thick backing course in CM (1:4) including pointing in white cement (1:2) using admixture of pigment to match the shade of granite stone including Cutting, rounded smooth edges and Polishing and taking down old unserviceable granite all as directed by Engineer-in-Charge.
Material and Labour Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment over including over 50 mm sand filling complete all as specified and directed.
Material and Labour Rendering 15mm (10 + 5 mm) thick in cement mortar 1:4 on fair faces of brick work or concrete surface in two layers each mixed with integral water proofing compound @ 2% by weight of cement (WPC shall be mixed with top layer only i.e 5mm thick) finished the surfaces even and smooth without using extra cement complete all specified and as directed. Note : - Water proofing compound shall be measured and paid separately as "Supply only" item under relevant item of these schedule.
Material and Labour Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
Material and Labour Rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
"Supply only" liquid water proofing compound (ISI marked) complete all as specified and directed. Make:- STP NO 1/ PEDILITE(DR FIXIT)/ FOSROC/ CICO/ SIKA
Materials and labour Preparation of newly plastered wall surfaces of any description and applying two coats of acrylic distemper of any colour/ tint over a coat of 2mm white cement putty and primer complete all as specified and directed.
Materials and labour Preparation of newly plastered wall surfaces of any description and applying three coats of white wash complete all as specified and directed.
Materials and labour Preparation of newly plastered ceiling surfaces of any description and applying three coats of white wash complete all as specified and directed.
Materials and labour Preparation of newly plastered wall surfaces of any description and applying two coats of cement based paint of any colour / tint over a coat of alkali resistant primer complete all as specified and directed.
Material and Labour Preparation of new steel surfaces of any description, over 10 Cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint of any colour / tint over a coat of red oxide primer complete all as specified and directed.
Supply and fix 110 mm bore, PVC (SWR) pipe, single socketed, in any length with rubber ring joints fixed to wall etc complete all as specified and directed .
Supply and fix 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
Materials and Labour Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as directed by Engineer-in-Charge.
Materials and labour Forming Construction joint 30mm deep x 10mm wide filled with sealing compound of Grade 'A' complete all as directed by Engr-in-Charge .
Taking down carefully any type of point wiring (light, fan, bell, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets ( including light fittings) etc stacking at site for reuse of serviceable items and removal of unserviceable items from site and making good disturbed faces of walls, ceiling, floor etc to match with the existing surface complete all as specified and directed by the Engineer-in-charge.
Material and labour Point wiring with PVC insulated and unsheathed FR grade cable single core multistranded copper conductor 1.5 Sqmm size, 1100 volts grade cable confroming to IS - 694 1990 drawn through and including PVC casing and caping of suitable size with all accessories including fabricated 1.6mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 Sqmm multistranded PVC insulated FR grade and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one switch and switch socket outlet / light point on independent board complete all as specified and as directed.
All as per item No.62 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. 62.00 here-in-before but using 2.5 Sq mm size FR type stranded copper conductor cable for one 16 amp switch socket outlet on independent board complete all as specified and directed by Engineer-in-Charge.
Supply & fix Switch piano, flush type, SP, one way, 5/6 Amps 230 Volts, white/ivory finish
Supply and fix Socket outlet 5 pin, 6 Amps, 230 volt flush type complete all as specified and as directed.
Supply and fix Switch socket combination multipurpose 2 in 1, 5 pin 6 Amps 230 volt flush type complete all as specified and as directed.
Supply and fix Switch socket combination multipurpose 2 in 1, 3 pin 5 & 15 Amps 240 volt flush type complete all as specified and as directed.
Supply and fix Ceiling rose surface bakelite three terminals 230 volts complete all as specified and as directed.
Supply and fix Electronic step type fan regulator 230 Volts complete all as specified and as directed.
Taking down MCB DB of any type and capacity including old unserviceable MCB of any capacity including making good disturbed surfaces complete all as directed by Engineer-in-Charge.
Supply and fix Sheet steel phosphorised powder coated neutral link earth bar DB's double door where MCBs to be used 4 way single pole and neutral with 200 amps rated bus bar complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/L&T
Supply and fix MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve braking capacity 10 kA as directed by the Engr-in-Charge. Make:- Schneider/ ABB/Legrand/L&T
Supply and fix MCB 63 Amps, DP, 240 Volts , 'C' curve braking capacity 10 kA as directed by the Engr-in-Charge. Make:- Schneider/ ABB/Legrand/L&T
Supply and fix LED tube light fittings of with LED tube capacity 20W suspended type/ wall mounted type including all accessories and necessary connection with copper conductor complete all as specified and as directed. Make:- Bajaj cat Part No. BCLAB 20 W WH LED P or Make:- Crompton cat Part No. LDL-20-CDL or Make:- Havells cat part No. LUMILINEPLUSBS20WLED865SPCSS.
Supply and fixing Surface Recess mounted LED luminaries 36/34 watt , 2'x2' with all fittings and fixtures and connection with PVC cable of 0.50 sq mm three core copper conductor complete all as specified and as directed. Make:- Bajaj cat part No. BCTBLR 36W LED FP CW or make:- Crompton cat part No.CCR-132-36-57-SL-NWH or make:- Surya cat part No. SLE DS 36 22R.
Supply and laying in trenches, passing throught wall/ pole, fixed to wall / pole XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 25 Sqmm 4core with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge. Note:- Thickness after punning down shall be measured for payment.
Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
Materials and Labour Cutting existing road / path etc for taking out cable and proction pipe and making good the disturbed surfaces with cement concrete type C2 ( 1:3:6, using 40mm graded crushed stone aggregates) of suitable depth complete all as directed by Engineer-in-Charge.
Taking down sub main wiring of any type of conductor alongwith damaged casing caping / conduit pipe from the wall, roof etc including making good disturbed surfaces complete all as directed.
Materials and labour Sub main wiring with 2 runs of single core PVC insulated FRLS type, unsheathed stranded copper conductor of size 4 Sqmm and one run of PVC insulated, FRLS type, unsheathed multistrand copper conductor of size 2.5 Sqmm as earth lead drawn in and including PVC non metallic rigid conduit, 20mm external dia, ISI marked including all fittings complete all as specified and as directed. Note:- One run of 4 Sqmm cable and one run of 2.5 Sqmm cable with one run of PVC conduit shall be measured as one unit.
Supply and fix GI pipe, 40mm bore, light grade for protection & passing of LT cable fixed to pole/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 40mm bore dia all as specified & directed.
Supply and fixing commissioning & testing of 16 Mtr High Mast, Polygonal, Tapered, and Flange mounted type, Totally Hot Dip Galvanized with steel EQUIVALENT TO BSEN 10025 suitable for wind velocity as per IS 875 Part 3. The mast shaft shall be in Two sections with no circumferential weld and shall be stress fitted at site along with supply of accessories which includes include heardframe, lantern carraige with 8 luminaire arms, SGDD winch of 500 Kg capacity with 6 mm wire ropes (2 wire rope system), lightning arrestor, Junction box, trailing cable of 5c x 2.5 sq mm size for single circuit, carraige supports suitable for mounting 08 Nos of 150 Watt LED luminaires for 16 Mtr High Mast. Supply and fixing of foundation accessories (one set of foundation accessories includes-8nos. M30x850 foundation bolts plus one anchor plate plus 50% template) and High Mast control panel as per standard for raising and lowering of high mast including single dial timer and including Supply and fixing of 150 Watt LED Flood Light Fittings. This also includes Design, casting of suitable open raft shallow RCC foundation with M-20 grade concrete suitable for safe soil bearing capacity of 10 T/Sq. mtr at the depth of 2.0 mtr below ground level alongwith supply of foundation bolts manufactured from special steel with nuts, washers, suitable size anchor plate, templates along with modern Engineering practices and provision of GI pipe earthing as per IS 3043 for High Mast with 4.5M long 40mm dia with GI strip 25x4mm with all materials & labour. Detail of High Mast section is as under:- (i) Bottom OAF-410 mm (ii) Top OAF-150 mm (iii) Bottom section thickness-4 mm (iv) Top section thickness-3 mm (v) Bottom section length=8300 mm (vi) Top section length=8300 mm (vii) Base plate of dia 570 mm x 25 mm thickness suitable for mounting 8 nos. of 150 Watt LED luminaires symmetrically Complete all as specefied and as directed by Engr-in-Charge. Note:- The quoted rate shall be deemed to include the following:- (i). Erection of the High Mast with the help of suitable equipments and wiring of luminaires with all wiring material & labour.(ii). Installation of control panel on suitable foundation including all material & labour. (iii) High mast should have indentification mark of manufacturer. (iv) Detailed technical data sheet shall be of specification attached. (v) High mast shall be installed by authorized company rep only (vi) Make of all the products of particular High Mast shall be of same company or recommended by the company Make of High Mast:- Surya/ Bajaj/ Phillips
Supply and fix MCCB, 3 pole 415 volts adjustable size type 160 amps with breaking capacity 36 kA complete all as specified and as directed.
Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed
BHASKAR SUPPLY AGENCY
SREE GURU CONSTRUCTION CO
SPECIAL CONCRETE AND CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .