| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹16.2 L+₹89,637 (5.87%)Rejected-AOC | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹17.7 L+₹2.4 L (15.8%)Rejected-AOC 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹18.0 L+₹2.7 L (17.8%)Rejected-AOC | L4 | Rejected-AOC NOT BEING L1 | |
| 5 | L5₹18.4 L+₹3.1 L (20.4%)Rejected-AOC PLOT NO 26 1ST FLOOR PRATAP NAGAR NEAR JAIL ROAD NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L5 | Rejected-AOC NOT BEING L1 |
Tender Value
₹22.4 L
EMD Value
₹44,760
Closing Date
4 Feb 2023, 6:00 pmClosed
GE E/M RR HOSPITAL
GE E/M RR HOSPITAL DELHI CANTT-10
SPECIAL REPAIR TO FLOOR FALSE CEILING COMPLETE INTERNAL FITTINGS IN AUDITORIUM GALLERY CORRIDOR AT 2ND FLOOR OF BLDG NO P 105 AT ADC RR UNDER GE EM RR HOSPITAL DELHI CANTT 10
2023_MES_573727_1
GE/H-42/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE E/M RR HOSPITAL DELHI CANTT-10
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE E/M RR HOSPITAL
₹44,760
Yes
10 Mar 2023
7 Jan 2023
6 Feb 2023
7 Jan 2023
4 Feb 2023
21 Jan 2023
Amount
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, fillets etc & existing electrical wiring, and removal of debries from site complete all as specified and directed.
S&F solid PVC wall panelling consisting of 5mm thick wood grain finish PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications, complete all as specified.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification, complete all as specified
S&F solid PVC lipping of 2mm wood grain finish PVC sheet is heat bent as as liping on the edges of doors, windows & other edges inclusive solvent cement and fixing at site, complete all as specified and directed.
M&L for exposed GI frame/ grid system duly powder coated for module size of 600 x 600 mm suitable for lay-in aluminium/ metal/ mineral fiber ceiling ties having main T runner of 24mm size, suspended at 1200 mm C/C and cross T runner of 24 mm size, suspended at 600 mm C/C with interlocking arrangement to form grid of 600 x 600 mm , perimeter runner/ channel of 15 mm size, main and cross T runner supported by 4mm dia GI rod from slab/ roof, wall angle etc with and including all fixing accessories and making good of disturbed wall surrfaces with POP and one coat of oil emulsion distemper, as required to match the existing surfaces, complete all as specified and directed.
M&L for metal false ceiling, lay-in type, 0.5mm thick having tegular edge profile , duly powder coated, perforated type with glass fiber acoustic fleece, suitable for false ceiling grid/ frame module of 600 x 600mm size, complete all as specified and directed. (Note : The grid/ frame shall be measured and paid for separetly).
Dismantling boarding any description, fixed in any position with screws, complete all as specified & directed.
M&L for wooden flooring, laminated wooden type made of high density fibre board (HDF board), comprising of tongue and groove interlocking type of planks of size 1210mm x 193mm & 8mm thick, commercial grade, abrasion resistance of AC-III category, with and including all fixing material i.e. chemical adhesive, base strip/ fillets etc veneered and matching top beading etc, complete all as specified and directed.
Removing the existing chairs and refixing the same after the flooring work is completed, complete all as specified and directed. Note: Rate for removing the chairs and refixing the same are included in this item.
Taking down old unserviceable point wiring with and including existing conduit / batten type (light, fan, socket or power point) complete such as tube light any type switches, ceiling rose, pendent holder, regulator and socket etc and removing the material from site with chasing and cutting surface of wall / floor/ ceiling etc complete all as specified and directed. Note :- Tube light taking down be carefully and Keep in Safe custedy for re-use.
Taking down existing sub main wiring aluminium/copper 4/6 sqmm, including existing conduit, complete all as specified and directed.
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked including cutting and chasing and PVC concealed conduit ISI marked of size 20 mm bore medium grade and PVC conduit fittings such as tees, bends, elbow, reducers including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches/sockets/fan regulator of any type etc and making good surface as original by plastering and whitewash/ colour/ distemper etc, complete all as directed for one light point / fan point / exhaust fan point / bell / buzzer controlled by one 1-way switch 6 Amps. (Note : The cost of any type Metal boxes and any accessories like cover plates etc will be included in quoted rate.)
All as per srl item No. 12 here in before but point wiring for one socket outet point 5 amps on the independent board.
All as per srl item No. 12 here in before but point wiring for one socket outet point 5 amps on the same board.
All as per srl item No. 12 here-in-before but with 2.5 Sqmm single core FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for one 3 pin 15 Amp socket outlet point by one way switch on independent board complete all as specified.
S&F in repair modular switch 6 amps one way, SP, 250 volts AC IP 20 protection, complete all as specified and directed.
S&F in repair modular switch with indicator 16 amps one way, SP, 250 volts one module complete all as specified and directed.
S&F in repair modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed.
S&F in repair modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed.
S&F in repair Ceiling fan regulator, stepped type of 0 to 04 rotary steps, elecronic, 02 module, humfree, AC 230 volts, 100 watts, duly ISI marked complete all as specified and directed.
S&F in repair ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps with and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as specified and directed.
S&F in repair wall mounted LED batten with polycarbonate housing and initigrated electronic drive 20 watt fixture 4 feet provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair surface/ ceiling mounted LED panel type of size 2ft x 2ft, 36W, 230V, 5700K complete with driver having precisely designed decorative PMMA diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete all as specified and directed.
M&L in replacement Sub main wiring concealed with 4 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point complete all as specified and directed.
S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, with 200 Amps rated copper bus bar 12 Way and metal door with IP - 43 & IK 09 protection along with cable end box for DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts of following ways with 200 Amps rated copper bus bar 8 way and metal door with IP 43 & IK 09 protection along with cable end box for DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed
S&F in repair MCCB 4 pole, 415 Volt 125 Amp, 36 KA breaking capacity adjustible type, complete all as specified and directed.
S&F in repair MCB SPN, AC, 240 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
S&F in repair MCB, SP, AC, 240 volts of 6 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
Supply and fix in replacement of MCB protected modular AC/Geyser box complete with and including 6 pin socket, plug top, modular cover plate, mini MCB SP 20 Amp capacity and PVC gang box etc, complete all as specified and directed.
LAXMI BUILDERS
R. S. Associates
sony engineering works
Shivam Firetech Engineers
OMVIN ENTERPRISES LLP
CHAUHAN ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .