| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.1 LAccepted-AOC 60 MADHUVAN BANK COLONY ALWAR | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹45.0 L+₹2.9 L (6.77%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹45.0 L+₹2.9 L (6.90%)Rejected-Finance A 103 VEERA GARDEN AMBEDKAR NAGAR ALWAR 301001 RAJ | ALWAR | RAJASTHAN | 301001 | L3 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/S JINDAL ENTERPRISES L1 | shiva construction L2 | Hitesh Construction L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.50m wide and not exc 1.50m in depth and getting out in any type of soil complete all as specified and directed. | 233 | Cum | 151 ₹35,183 | 350 ₹81,550 | 150 ₹34,950 Lowest |
| 2.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. | 171 | Cum | 65 ₹11,115 Lowest | 100 ₹17,100 | 75 ₹12,825 |
| 3.00 | Removing surplus excavated soil to a distance n.exc 50 metre and n exc 100 metre and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. | 62 | Cum | 65 ₹4,030 Lowest | 100 ₹6,200 | 75 ₹4,650 |
| 4.00 | Surface excavation n exc 30cm deep and averaging 15cm deep in any type of soil complete all as specified and directed. | 20 | Sqm | 35 ₹700 | 20 ₹400 Lowest | 20 ₹400 Lowest |
| 5.00 | M&L sand filling under floor or in fundations including watering and consolidation complete all as specified and directed. | 0.3 | Cum | 650 ₹195 | 300 ₹90 Lowest | 1,000 ₹300 |
| 6.00 | PCC (1:4:8) type D-2, using 40 mm graded stone aggregate in fdn mass concrete complete all as specified and directed. | 10 | Cum | 3,000 ₹30,000 | 2,500 ₹25,000 Lowest | 4,000 ₹40,000 |
| 7.00 | M&L RCC work Design Mix (M25) as in foundation including , raft, plinth beam bases for column etc basement slabs under rammed piles and mass concrete complete all as specified and directed. | 30 | Cum | 5,600 ₹1,68,000 | 5,300 ₹1,59,000 Lowest | 5,500 ₹1,65,000 |
| 8.00 | M&L RCC work Design mix(M-25) as in columns, pillars , piers posts and struts complete all as specified and directed. | 21 | Cum | 5,600 ₹1,17,600 | 5,300 ₹1,11,300 Lowest | 5,500 ₹1,15,500 |
| 9.00 | M&L RCC work design mix (M-25) as in beams, cantilevers bressumers, lintel over 1.5 mtr span complete all as specified and directed. | 30 | Cum | 5,600 ₹1,68,000 | 5,300 ₹1,59,000 Lowest | 5,500 ₹1,65,000 |
| 10.00 | M&L RCC work design mix M-25) as in slab supported in walls cantilevers etc complete all as specified and directed | 37 | Cum | 5,600 ₹2,07,200 | 5,300 ₹1,96,100 Lowest | 5,500 ₹2,03,500 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
26 Sept 2025, 6:00 pmClosed
GE Alwar
Alwar
PROVN OF LIBRARY COMPUTER ROOM AND CLASS ROOM OF ARTY DIV CAMP AND OTHER MISC SANCTIONED WORKS AT ITARANA MIL STN ALWAR
2025_MES_728252_1
8448/E8
Open Tender
Civil Works
Item Rate
180 days
Alwar
As per NIT
6 documents required · 6 mandatory
₹500
GE Alwar
₹97,000
Yes
27 Dec 2025
28 Aug 2025
29 Sept 2025
28 Aug 2025
26 Sept 2025
12 Sept 2025
28 Aug 2025 - 11 Sept 2025
Amount
Excavation in trenches not exceeding 1.50m wide and not exc 1.50m in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing surplus excavated soil to a distance n.exc 50 metre and n exc 100 metre and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Surface excavation n exc 30cm deep and averaging 15cm deep in any type of soil complete all as specified and directed.
M&L sand filling under floor or in fundations including watering and consolidation complete all as specified and directed.
PCC (1:4:8) type D-2, using 40 mm graded stone aggregate in fdn mass concrete complete all as specified and directed.
M&L RCC work Design Mix (M25) as in foundation including , raft, plinth beam bases for column etc basement slabs under rammed piles and mass concrete complete all as specified and directed.
M&L RCC work Design mix(M-25) as in columns, pillars , piers posts and struts complete all as specified and directed.
M&L RCC work design mix (M-25) as in beams, cantilevers bressumers, lintel over 1.5 mtr span complete all as specified and directed.
M&L RCC work design mix M-25) as in slab supported in walls cantilevers etc complete all as specified and directed
M&L RCC work design mix (M-25) as chajja complete all as specified and directed
M&L TMT bars, 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per srl item No 12.00 but 5mm to 10mm dia as in stirrups, spacers binders etc complete all as specified and directed.
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L Formwork to sides and soffits of floor or roof beams, beam hunching’s, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M & L Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface areacomplete all as specified and directed.
M & L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact complete all as specified and directed.
M & L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M & L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
Supply only liquid water proofing compound
M&L water proofing treatment to RCC roof slab including parapet comprising of following course of treatment/specified from bottom to top (a) 20 mm thick Plaster on RCC roof slab with CM ( 1:3 ) for surface leveling including water proofing compound @ 3% by weight of cement shall be carried out (b) Applying Bituminous primer @ 0.40 Ltr per sqm over plastered surfaces of roof including parapet surfaces. (c) Over the priming coat laying one layer APP polymeric membrane of approved manufacturer, 3 mm thick weight not less 3.5 Kgs/Sqm and upper side, laid on or over a coat of bitumen VG-10 @ 1.2 Kg per Sqm, it shall be laid by torch application . side overlap should be 75mm and end shall be 100mm. (d) Applying two coats of heat resistance paint over membrane complete all as per manufacturers instruction Note:- For parapets, membrane shall be taken to a height of minimum 60cm and then inserted inside parapet in groove. The same shall be finished by a membrane flashing complete all as specified and directed.
M&L providing precast cement concrete (1:2:4) type B1, using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span,cills, steps, seismic and other similar bands, plinth courses, string courses , lacing courses, parapets and railings upto 60cm in height, copings kneelers, apex stones, bed plates, kerbs not provided for in item No 04028 water troughs and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L brick work with fly ash 'brick straight or curved on plan exc 6m mean radius built cement mortar 1:6 complete all as specified and as directed
M&L 15mm thick rendering in cement mortar 1:4 on fair faces of brick work surface rendering is to be even and smooth without using extra cement including WPC @ 3% on wt of cement complete all as specified and directed.
M&L15mm thick rendering in cement mortar 1:6 on other than fair faces of brick work surface rendering is to be even and smooth without using extra cement including WPC @ 3% on wt of cement and cutting of grooves at joint ob bricks and concrete surfaces complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers , under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per/sqm , top layer 15mm cement plaster 1:1.2:2 (1 cement : 1/2 coarse sand : 2 stone chipping 10mm nominal size ) in panels with groovs all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings complete all as specified and directed.
M&L rendering 5 mm thick in CM 1:3 on concrete ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of newly plaster surface of wall & applying two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint. Make - Nerolac Excel Top guard (10 years product warranty)/ Asian Paints Ultima Protek (10 years product warranty)/ Berger weather coat long life 10 (10 years product warranty) at any height including necessary scaffolding complete all as specified and directed.
M&L preparation of newly plastered surface of wall including 01 to 02 mm average wall care putty and applying two coats oil bound distemper over a coat of primer complete all as specified and directed.
M&L preparation of newly plastered surface of ceiling applying three coats of white wash complete all as specified and directed.
S&F powder coated aluminium door anodised of approved colour (size of frame 63.5mm x 38.10 x 2mm thick & size of shutter door vertical (style) with gasket of size 46.3mm x 45.00mm x 1.5mm thick, top rail of size 47.00mm z 45.00mm x 1.30 mm lock rail/middle rail 83.00mm x 44.50mm x 1.65mm thick bottom rail 114.3mm x 45.mm x 1.50mm thick including S & F of 4.8mm thick sheet glass with glazing clip, PVC track gasket, EPDM rubber gasket on glass of weather tightening alongwith recessed type handle, hinges mortic lock complete all as specifed as per TD-200451R sheet 1/1.
S & F door closer hydraulically regulated aluminium (extruded section body) designation No 3 unverasal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
All as per srl item No 34.00 but fixed in repair.
S&F Aluminium windows made of 1.59 thick powder coated (thickness of powder coating not less than 50 micron) as per aluminium section of size given below . Aluminium window will be of double shutter of one glass/ one wire gauge shutters including frame with Aluminium U channel all necessary accessories jointing cleats , glazing clips, rubber neoprene packing, for fixing glass/ wire gauge, aluminium handles and tower bolt 2 Nos 100 mm ‘D’ Type in each door, 2 Nos 100 mm aluminium hinges including necessary steel screws complete all as specified and directed by Engr The size of different aluminium section to be used is as under (a) Outer Frame 125X45X2 mm thick (b)shutter frame section size 44X44X1.59 mm thick for glass and 44x22x1.59mm for wire gauge complete all as specified and directed. Note: Rates quoted are inclusive all fittings and fixtures. Glass and wire gauge will be paid separately in respective items.
M&L 75 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation filling and mass concrete as floor sub base complete all as specified and directed.
M&L PCC 25mm thick 1:2:4 type B0 (using 12.5mm graded aggregate) as in floor as in leveling course complete all as specified and directed.
M&L for non skid ceramic tiles (coloured) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.36 Sqm but not exceeding 0.96 Sqm in floors etc. laid over 15 mm screed bed or bedding layer in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile Complete all as specified and directed.
All as per srl item No 39.00 but in skirting and dado including rendering/screeding including cement mortar 1:4, 10mm thick complete all as specified and directed.
M&L 50mm thick cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in plinth protection path laid in panel surface finished even and fair using extra cement complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade and fixed with grey cement and pigment over sand cussuion complete all as specified and directed.
M&L brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified.
M&L rendering 10mm thick in cement plaster 1:4 on surfaces on fair faces of brick work and surface finished even and smooth without using extra cement complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation filling and mass concrete as floor sub base complete all as specified and directed
M&L PCC 1:3:6 type C2 using 40mm graded aggregate as in surface chanel and drain complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds mitred/stopped ends etc complete all as specified and directed.
Reinforced concrete pipes, class NP2, 300mm dia laid and jointed complete with collars complete all as specified and directed.
M&L PCC 1:2:4 Type B0 (using 20 mm graded aggregate as ) as in coping , roof curves, mud stops rounded or chamfered on edge complete all as specified and directed.
Dismantling of Stone slabs and tiles laid beaded and pointed in any mortar of any description or thickness in floors, aprons, complete all as specified and directed.
M&L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles including Screed bed of mortar 15mm thick for laying floor finishes in CM (1:6) complete all as specified and directed.
M&L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles including Screed bed of mortar 15mm thick for laying floor finishes in CM (1:6) complete all as specified and directed
M&L for suspended false ceiling system in 4mm thick 'E' board ceiling tiles classic/ designer as approved by GE of size 595 x 595 mm fixed with and including galvanized iron powder coated GI grid system suspended from ceiling with provision of galvanized wire 4mm dia with butterfly clips and wall taping screw hold down clips for fixing the board to frame complete all as per manufacturer's instructions complete all as directed and specified. (a) Size of grid - 600 x 600 mm (b) Size of main tee - 39 x 24 x 0.3 mm (c) Size of cross tee - 24 x 24 x0.3 mm (d) Size of wall angle - 24 x 24 x 0.4 mm
M&L non skid ceramic coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc, set and jointed in neat cement slurry and pointed in white and coloured cement to match coloured tiles including Screed bed of mortar 15mm thick for laying floor finishes CM (1:6) including dismantling old tiles complete all as specified and directed.
M&L for glazed ceramic colour tiles in vertical surface 450X 300X 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 10 mm thick rendering in CM (1:4), including dismantling old tiles complete all as specified and directed.
Taking down cement or lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for Radiation shield wall tiles (Suitable for X-Ray room) of 12mm thick of size 300mmx300mm of terrakota/white colour set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 10 mm thick rendering in CM (1:4) complete all as spd and directed. Note :- All switch board on wall will be refixed and nothing extra cost will be paid on this account complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) exc 1.50 sqm but n exc 4 sqm in each complete all as specified & directed.
Taking down shutter of any description, exc 1.0 sq.m but n.exc 2.00 sqm each complete all as specified & directed.
M&L for mild steel work as in door chowkhat of angle iron including necessary cutting and welding conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed.
S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F for single leaf lined with 2mm thick lead sheet fixed on wooden doors and overlapping at joints complete all as spd and directed.
M&L two coats of synthetic enamel paint over one coat of pink primer on wood or wooden based surface exc. 10cm width or girth including preparation of new or previously untreated surfaces complete all as specified and directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe-290 Gde E-165 (Brackets over 10 kg each to be measured under ‘Structural Steel') complete all as specified and directed.
M&L for two coats of synthetic enamel paint on new steel surfaces over one coat of red oxide over 10 cm width or girth not otherwise described, complete all as specified and directed.
M&L for concealed Point wiring for One Light point controlled by one, one way switch with two single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box modular with cover plate of requird Module to fix switches and sockets complete all as specified. Note - 1. Quoted rate shall include cutting chases in wall of Bricks or Stone as per site requirement and making good to the disturbed surfaces including plastering and painting to match with the existing colour complete all as specified and directed. 2. The quoted rates shall be deemed to be included the cost of modular cover plate of required module with frame and metal flush box of required size and no additional payment shall be made on account of the same.
All as per srl item No 66.00 but for One 3 pin switch socket outlet, 5 Amp on the same board with other switches.
All as per srl item No 66.00 but for One 3 pin 5 amps switch socket outlet point on independent board.
All as per srl item No 66.00 but for One fan point controlled by one switch and regulator
All as per item Srl. No. 66.00 here in before but wiring with 4.0 sq.mm multistranded cable and earth wire with copper conductor of size 4.0 sq.mm for 15 amps power/geyser point.
Supply and fixing Modular switch, one way 6 Amp, 1 module, piano type, 230/250 volts grade on top covers (catered in point wiring above).
All as per srl item No 71.00 but for Modular switch, one way 16 Amp, 1 module
Supply and fix Modular socket outlet 2in1, 3pin 5A, 2 module, multipurpose use, flush mounting type, 230/250 Volts grade on Top covers (catered in point wiring above).
All as per srl item No 73.00 but for Modular socket outlet 2in1, 3 pin 15 Amps flush type
Supply and fix ceiling rose surface bakelite two to three terminals/plate, polycarbonate, isolated body.
Supply and fixing PVC Blanking Plates one way with internal lock complete.
Supply and fix LED batten (1.2m) made of CRCA sheet housing with a PC glossy diffisure duly prewired connection having nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 20 watt including driver. it should have rated system life time of 40000 burning hours at L70 and should have a temperature of 6500 K CRI >80, thd <10 and PF>0.95 complete all as specified and directed.
Supply and fixing LED light fitting as building security lights of 35 Watt Cap 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover, incl street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-In-Charge
Supply and fixing lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified.
Supply and Fixing 20 watt emergency LED inverter bulb B-22 capacity with inbuilt powerful lithium battery backup of atleast 4 hours and having minimum two years warranty. The lighting shall have deep discharge protection, fast charging, offering cool day light for atleast four hours in off hours complete all as specified and directed. Make : - Havells/Philips/Bajaj
Supply and fix ceiling fan complete with electronic type regulator , copper winding and accessories 230v 1200mm sweep BEE 5 star rated with brushless direct current motor (BLDC) including taking down old unserviceable ceiling fan complete all as specified and directed by engineer-in-charge.
supply and fix exhaust fan metal body AC single phase 230/240 V of size 300 mm sweep with louver including making suitable opening/hole in wall all as specified and directed by ebgineer-in-charge
S&F sheet metal enclosure concealed in wall incl making good of disturbed surfaces double door type suitable for fixing MCB's, SPN with 200 Amps rated bus bar, 8 Way, 230 Volts and including taking down old U/S DB ,SPN,8 way complete all as specified & directed.
Supply and fix Vertical TPN DB 4 way suitable for Double Pole outgoing MCB-40 Amp-04 Nos with incoming 100 Amps, 16 KA, MCCB 4 pole-01 Nos complete with 250 Amps rated Copper busbar flush mounting, double door, proction class IP-30, IK08 complete all as specified
Supply and fixing 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 6-32 Amp poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-In-Charge
All as per srl item No 85.00 but for SPN 40-63 Amps
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with 01 No. double pole MCB 32 Amps & including taking down old U/S enclosure complete all as specified & directed .
Material & Labour for Sub Main Wiring in repair with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 6 Sqmm copper green colour earth wire all as specified and directed by Engr-in-Charge. NOTE-two run of 6 sq.mm & One run of 6 sq.mm & One run of PVC conduit with accessories shall be measured as One length.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.30mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & directed.
Supply, install, testing and commissioning of water cooler fully stainless steel, electric driven single phase having storage capacity 80 ltrs and nominal cooling capacity 40 ltrs per hour complete all as specified and directed by Engr-In-Charge. Make - Voltas/ Blue star/ Usha/ Hitachi/ Daikin
Supply, installation, commissioning of Eveporated air cooler in steel body (desert cooler) of size 26x26x39 inches sump capacity 120 Ltrs of water maximum sump depth upto 12 Inches with propeller cooler fan made out of hot deep galvanised steel thickness 1 mm body and 2 mm removal side and back panel single phase 230 volts of fan size 450 mm sweep heavy duty exhaust fan blade, Cooler Motor 195 Watt with submersible pump of suitable size (Maximum power consumption 100 watts) ISI marked having normal air flow capacity 6000 cum/Hr with float valve of 15 mm dia, stop valve of 15 mm dia and all necessary arrangement to take water from GI Pipe 15mm dia to Air cooler (Note (a) :- Sufficient length of 3 core PVC sheathed round copper cable size 23/076 to enable fixing in to plug point shall be provided by contractor. (b) :- Arrangement of power connections and water connections to the desert cooler will be included in installation.
Supply & install, testing & commissioning LT control panel compartmental type,Lockable fabrication with dimension 1200(H)x 500(W)x 500(D) made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (40mmx40mmx6mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glands, foundation /grouting on & including PCC as per site requirement with the following :- (a) Al bus bar 150 Amp Cap- 1 Set ( Set of 4 strips) (b) MCCB 125 Amp 4 Pole 25 KA - 1 No (incoming) (c) MCCB 63 Amp,4 Pole,16 KA with spreader links - 3 Nos(Outgoing) (d) Indicating Lamp LED type R,Y,B - 3 Nos (e) Control fuse - 3 Nos
Supply and fixing of GI water tubing IS-1239 marked, medium grade, in replacement including all necessary pipe fittings laid in trenches, on wall, under floor, under road on same or new route and making good the disturbed portion as existing and including taking down of old unserviciable pipe of the size 25 mm bore complete all as specified and directed. Note : Excavation and earth work will be measured and paid separately.
All as per srl item No 93.00 but for 20 mm bore
S&F 25 mm bore gun metal gate valve with iron wheel head, screwed both ends for jointing iron pipes, non rising, forged brass spindle class-1, ISI marked complete all as specified and directed.
Supply, laying and testing of cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 50 Sqmm 3.5 Core complete all as specified and directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
All as per srl item No 96.00 but for 16 Sqmm 4.0 Core.
Supply and spreading, levelling river sand in trenches for cables cushioning on top and bottom of cable all as specifede and directed.
M&L brick protection with sub class'B' brick laid flat across the cable complete all as specified and directed
M&L for boring under roads for crossing of UG Cables complete all as specifie and directed by Engr-In-Charge.
Supply and fix GI Pipe light grade of size 40 mm laid in trenches under road/fixed on wall/pole for cable protection complete all as specified and directed by Engr-In-Charge
shiva construction (BID ID -3436014)
Hitesh Construction (BID ID -3436035)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .