Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC Accepted as per L1 bidder | |
| 2 | L2₹17.1 L+₹21,595.65 (1.28%)Rejected-AOC WARD NO 12 TAMLUK PARBATIPUR TAMLUK PURBAMIDNAPUR 721636 | TAMLUK | PURBA MEDINIPUR | WEST BENGAL | 721636 | L2 | Rejected-AOC Rejected as per L2 bidder | |
| 3 | L3₹17.1 L+₹22,253.55 (1.32%)Rejected-AOC MAIRAKATA P O GARBETA DIST PASCHIM MEDINIPUR 721127 | GARBETA | PASCHIM MEDINIPUR | WEST BENGAL | 721127 | L3 | Rejected-AOC Rejected as per L3 bidder |
Tender Value
₹17.1 L
EMD Value
₹34,203
Closing Date
23 Dec 2024, 12:00 pmClosed
RM Paschim Medinipur Region Office
Administrative Building (2nd Floor) Power House Complex Burdge Town
CONSTRUCTION of switchyard structure alongwith installation of all equipements and laying of cable at Kushpata 33/11 KV s/stn under Ghatal Division under Paschim Medinipur Region
2024_WBSED_774772_1
RM/PMRO/E/e-Ten/24-25/2643
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
Kushpata 33/11 KV S/stn
Referred to NIT
2 documents required · 2 mandatory
₹0
₹34,203
Paschim Medinipur Region Office
23 Jul 2025
27 Nov 2024
27 Dec 2024
27 Nov 2024
23 Dec 2024
28 Nov 2024
28 Nov 2024
Amount
Erection of four pole along with 33kV cable raising on support and LA arrangement including Rail pole ( Rail Pole will be supplied by the WBSEDCL) Pole(including 450x100 mm thick cement concrete (1:3:6) base block below Pole and hard jhama metal cement concrete (1:2:4) with 0.30 mtr. Muffing above ground level including neat cemented finish with supply of all items.) along with fittings complete with painting of Rail Pole(1 coat red oxide & 2 coat Alluminium paint of reputed company including supply of paint ) with Insulators other accessories & fittings complete for 33 kV 400A H.L. CR Type Isolator (ref drg: PLN(D)/SS/112) except fittings
Erection of 33 kV 400A H.L. CR Type Isolator
Supply & Erection of 11 kV Cable Support with LA (ref drg: PLN(D)/SS/85 )
Supply & Erection of GI Pipe of 150mm Dia (Make: Tata/Jindal) for aiding the riser portion of the 11kV Cable at cable supprt structure
Erection of 42kV Lightning Arresters on Cable Support Structure
Erection of 12kV Lightning Arresters on Cable Support Structure
Erection of conductor including Laying, Hoisting, stringing jointing,sagging,tensioning single wire ACSR Panther Conductor with suitable sockets, Aluminium binding wire ,Aluminium tape etc.
Erection of conductor including Laying, Hoisting, stringing jointing,sagging,tensioning single wire ACSR Dog Conductor with suitable sockets , Aluminium binding wire ,Aluminium tape etc.
Supply & Installation of Rigid type Extruded Aluminium connector PAD to Panther (Sample to be approved by the Site Engineer)
Supply & Installation of Clamp type connector LA pad to ACSR Panther (Sample to be approved by the Site Engineer)
Supply & Installation of Clamp type connector LA pad to ACSR DOG (Sample to be approved by the Site Engineer)
Supply & Installation of Bi metalic connector PTR HT stud to Panther (Sample to be approved by the Site Engineer)
Supply & Installation of Bi metalic connector PTR LT stud to Panther (Sample to be approved by the Site Engineer)
Installation and commissioning of 33kV Indoor type Breaker ( 2IC + 2 TRF + 3 BUS PT + 2BC + 2 RISER + 1 SS TRF + 1 OG)on concrete floor by grouting 75×40×6 mm G.I. Channel and cutting of concrete base in control room including making necessary connections of Power & Control Cables(Base MS Channel / Angle/ Flat will be supplied by the agency)
Unloading, placement, erection & commissioning of RTCC Panels for PTR
Erection and commissioning of 33 KV Indoor type, CR Panel for indoor type VCB on concrete floor by grouting 75×40×6 mm G.I. Channel and cutting of concrete base in control room including necessary connection with Relays, Metering/ Measurements equipments etc. with supply and fixing of Gland, Ferrules, PVC Tape and Sockets etc.(Only CR Panel & Control Cable will be supplied by WBSEDCL)
Unloading, lifting of 11 KV Switch gear panels (2IC+1BC+8OG) from Ground Floor to 2nd Floor using ceiling and chain pulley/ other suitable arrangement, placement over floor cut out positions and commissioning of 11kV Incomer Panels at first floor of new CRB with necessary connections of power and control cables
Installation, initial charging( by authorised agency), cabling, interconnection cabling and commissioning of 30V, 100 AH Pb Acid battery on battery stand made of teak wood duly painted with anti rusting paint, battery insulators, inter-battery wiring using 30 sqmm copper single core multi strand cable, terminal connectors, & all other accessories and connectors as per approved drawings of WBSEDCL, technical specifications and scope of the work,(2V X 15 nos Battery and Battery Rack will be supplied by WBSEDCL).
Erection & commisioning of 30 V, 75 AH Battery Charger with necessary connection including supply and fixing of Gland, Ferrules, PVC Tape and Sockets etc. ( only 30V, 75AH Battery Charger will be supplied by WBSEDCL).
Laying of single XLPE 3C-400sqmm 33kV Grade Cable in cable trench
Making necessary complete connections alongwith assistance in indoor termination jointing of 3C-400sqmm XLPE cable at each indoor panel/switch gear installed at Ground Floor of newly constructed CRB
Assistance of End Termination Joint Outdoor type for3CX400sqmm 33kV XLPE Cable
Hanging/raising of the incoming 33kV 3C-400sqmm XLPE Cable from its existing location at the newly constructed cable trenches on cable rack/trays (Supplied by Agency) after lifing it from its existing location so as to complete the laying work including the riser part, elevated trench and floor cut out part.
Laying of 11kV 3C-300sqmm XLPE cable inside cable trench
Laying of 11kV 3C-185sqmm XLPE cable inside cable trench
Supply of GI Pipe of 150 mm Dia (Make: Tata/Jindal) for aiding the riser portion of the 11kV Cables from Ground Floor to First Floor (3Mtr for each cable)
Erection of GI Pipe at the rear side wall of the CRB using GI Flats to facilitate the riser part of the cable. One rubber gaskit of size 5mm thick and 65mm wide is to be fixed within the GI Pipe and GI Clamp for better gripping between the pipe and clamp
Fabrication of GI Clamps with locking and tightening mechanism using GI Flat 65x6mm (4nos Clamps per pipe,all materials to be supplied by the agency)
Fixing of GI Clamps(as above) at the rear-side wall of new CRB with 4" Fast Nuts (All fixing materials like Gutka, fast nuts etc are to be supplied by the contractor)
Hanging/raising of the incoming 11kV 3C-300sqmm XLPE Cable from its existing location at the newly constructed cable trenches on cable rack/trays after lifing it from its existing location so as to complete the laying work including the riser part, elevated trench and floor cut out part.
Hanging/raising of the Outgoing 11kV 3C-185sqmm XLPE Cable from its existing location at the newly constructed cable trenches on cable rack/trays after lifing it from its existing location so as to complete the laying work including the riser part, elevated trench and floor cut out part.
Laying of single XLPE 3C-185sqmm cable by formation of excavated cable trench,filling of sand & Bricks for facilitation of evacuation of Outgoing feeders
ELEVATED CABLE RACK(as per IS:4759 and zinc coating shall not be less than 610gm/sq. meter for all structural steel members in Hot Dip Galvanization Method):Supply, fabrication, erection and fixing of lead support using GI 100x50 MS Channel which are to be fixed by welding on both ends at the dropping plates from roof as erected from Civil Wing.
ELEVATED CABLE RACK(as per IS:4759 and zinc coating shall not be less than 610gm/sq. meter for all structural steel members in Hot Dip Galvanization Method):Supply, fabrication, erection and fixing of cross supports using GI 65x65x6 Angle of length 0.8m each and welded at both ends at intervals of 0.5m
ELEVATED CABLE RACK(as per IS:4759 and zinc coating shall not be less than 610gm/sq. meter for all structural steel members in Hot Dip Galvanization Method)Supply, fabrication, erection and fixing of base plates fabricated from GI 25x3mm flats of size 0.8m x 0.5m fixed by welding in such a way so as to form a mesh having square gaps of 50mm between the members. These plates shall be placed on the cable rack within the channel & angle support to provide flooring to the power cables.
ELEVATED CABLE RACK(as per IS:4759 and zinc coating shall not be less than 610gm/sq. meter for all structural steel members in Hot Dip Galvanization Method)Supply, fabrication, erection and fixing of cover plates using perforated GI sheet metal of size 1000mm x 750mm and 3mm thickness for covering the elevated cable trench. Diameter of the perforation should not exceed 3mm and the gap between two perforations should not be less than 30mm.
ELEVATED CABLE RACK(as per IS:4759 and zinc coating shall not be less than 610gm/sq. meter for all structural steel members in Hot Dip Galvanization Method)Fixing of Cover plates to the elevated cable rack by using 3/8"x1" MS Nuts and Bolts at intevals of 250mm directly to the dropping plates and MS Channel.
ELEVATED CABLE RACK(as per IS:4759 and zinc coating shall not be less than 610gm/sq. meter for all structural steel members in Hot Dip Galvanization Method)Design, Supply , fabrication & erection of GI Structure (Angle, Channel, Flat of any size) along with Nut bolt, washers etc. for formation of ramp structure for sliding 33KV/11KV XLPE Cables in cable spreader room
ELEVATED CABLE RACK(as per IS:4759 and zinc coating shall not be less than 610gm/sq. meter for all structural steel members in Hot Dip Galvanization Method)Supply and Erection of Hot Dip GI perforated cable tray 250mm X 100mm X 1.6mm for Control cable
ELEVATED CABLE RACK(as per IS:4759 and zinc coating shall not be less than 610gm/sq. meter for all structural steel members in Hot Dip Galvanization Method):Supply and Erection of Hot Dip GI tray cover 250mm X 15mm X 1mm for cable tray for Control cable
Laying and commissioning of Control Cables in cable trench/ pipes/underground/overhead(By Cable tray) laying including their termination at indoor/outdoor terminals including supply of glands, lugs, cable ties, tagging etc as required as per Technical Specification, approved Drawing of WBSEDCL & Scope of works :4 c x 2.5 sq.mm Copper Control Cable
Laying and commissioning of Control Cables in cable trench/ pipes/underground/overhead(By Cable tray) laying including their termination at indoor/outdoor terminals including supply of glands, lugs, cable ties, tagging etc as required as per Technical Specification, approved Drawing of WBSEDCL & Scope of works:8 c x 2.5 sq.mm Copper Control Cable
Laying and commissioning of Control Cables in cable trench/ pipes/underground/overhead(By Cable tray) laying including their termination at indoor/outdoor terminals including supply of glands, lugs, cable ties, tagging etc as required as per Technical Specification, approved Drawing of WBSEDCL & Scope of works:12 c x 2.5 sq.mm Copper Control Cable
Laying, testing and commissioning of LT Power Cables in cable trench/ pipes/underground/overhead(By Cable tray) laying including their termination at indoor/outdoor terminals including supply of glands, lugs, cable ties, tagging etc as required as per Technical Specification, approved Drawing of WBSEDCL & Scope of works:PVC 4C-120sqmm Al Cable
Erection of Double Pole Structure complete on 8 mtr PCC Pole with all fittings and foundation including isolator,insulator and other accessories (All materials except isolator,insulators ,conductor & pole will be supplied by the agency)
Erection and Commissioning of 100kVA 33/0.433kV Station Service Transformer at the newly constructed plinth/DP Structure
Connection of LT Power Cable at LV Side of the Station Service Transformer with supply of suitable connectors,sockets etc.
Ercetion of 9 mtr PCC Pole (including 450x100 mm thick cement concrete (1:3:6) base block below Pole and hard jhama metal cement concrete (1:2:4) with 0.30 mtr. Muffing above ground level including neat cemented finish with supply of all items.) along with fittings complete
Fabrication & erection of Iron materials complete (Top channel, X-bracing, pole clamps, CG bracket etc.)
Erection of 100 sq.mm ACSR Conductor including Hoisting, stringing, jointing, sagging, tensioning & route clearance (3-Wire)
Supply of GI Pipe of 150 mm Dia (Make: Tata/Jindal) for aiding the riser portion of the 11kV Cables at each Isolator DP (3M for each cable)
Fixing of Pin Insulator
Fixing of Disc Insulator
Fixing of TPGO Isolator 400A on DP Structure
Stringing and Sagging of ACSR 100sqmm including Hoisting, stringing, jointing, sagging, tensioning & route clearance (3-Wire)
Fixing of Caution Board
Earthing of Each Pole of Isolator DP using GI Earth Spike and GI Wire 5mm
Erection of HT Stay Set for the Isolator Structures
Ercetion of Rail pole (12.8 Mtr)/H-Beam Pole (including 450x100 mm thick cement concrete (1:3:6) base block below Pole and hard jhama metal cement concrete (1:2:4) with 0.30 mtr. Muffing above ground level including neat cemented finish with supply of all items.) along with fittings complete with painting of Rail Pole(1 coat red oxide & 2 coat Alluminium paint of reputed company including supply of paint ).
Drawal of Shielding wire by 50sqmm ACSR
Staying of 12.8Mtr Rail Pole Complete with necessary arrangement as per direction of the Site Engineer
MAHAKALI ENGINEERING WORKS (BID ID -5859542)
R.K.ENTERPRISE (BID ID -5842677)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .