Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC 156 1 GANDHINAGAR 156 1 SEC 22 ANANDVATIKA SOCIETY GANDHINAGAR GUJARAT GANDHI NAGAR GUJARAT 382010 | GANDHINAGAR | GUJARAT | 382010 | ₹7.9 L Quoted ₹8.4 L | L1 | Accepted-AOC Being a L1 bidder |
| 2 | L2₹9.4 L+₹96,900 (11.6%)Rejected-Finance | ₹9.4 L+₹96,900 (11.6%) | L2 | Rejected-Finance Not being a lowest tender |
| 3 | L3₹10.0 L+₹1.6 L (19.2%)Rejected-Finance | ₹10.0 L+₹1.6 L (19.2%) | L3 | Rejected-Finance Not being a lowest tender |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
30 Sept 2019, 6:00 pmClosed
GE BABINA
GE BABINA
REPAIR MAINTENANCE TO ELECTRIC CEILING FANS EXHAUST FANS AND AIR CIRCULATOR FANS AT TKD AND BABINA CANTT
2019_MES_280048_1
GE/BAB/23 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
184 days
GE BABINA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Babina
₹32,000
Yes
1 Aug 2020
6 Sept 2019
4 Oct 2019
6 Sept 2019
30 Sept 2019
19 Sept 2019
Amount
Taking down ceiling fan of any make any model of size 48" (1200 mm) sweep complete, dismantling and refixing the same after cleaning all parts of fan internally and externally and applying greasing, oiling of bushes and bearings etc including rewinding of ceiling fan with super enameled copper winding wire and necessary replacement of all worn out parts such as Condensor , bush, bearing, , Rotor and repalcement of rubber real , mild steel U Clamp ,nut & bolts , split pin and PVC insulated flexible cable for connection etc complete all as directed . Note:- for item No. 1 to 8 Note : (i) The cost of re winding and fixing charges of worn out parts deemed to be included is unit quoted rate . (ii) Worn out parts shall be measured and paid separately as Supply only under respective items of this BOQ. (iii) The fixing arrangement of fan with existing GI pipe down rod including hanging in position after repair will be the responsibility of contractor and deemed to be included in unit rate quoted by the tenderer (iv) Testing of ceiling fan for 24 hrs running condition shall also be the rsponsibilty of contractor and this aspect deemed to be included in unit rate quoted by the tenderer.
All as per Srl item No.1 above but 56" (1400 mm) sweep.
Description same as per item No 1 above, but exhaust fan of any make or any model of size 9" (225 mm) sweep painted with grey colour synthetic enamel paint complete all as specified and as directed
Description same as per item No 1 above, but exhaust fan of any make or any model of size 12" (300 mm) sweep painted with grey colour synthetic enamel paint complete all as specified and as directed
Description same as per item No 1 above, but exhaust fan of any make or any model of size 15" (375 mm) sweep painted with grey colour synthetic enamel paint complete all as specified and as directed .
Description same as per item No 1 above, but exhaust fan of any make or any model of size 18" (475 mm) sweep painted with grey colour synthetic enamel paint complete all as specified and as directed . .
Description same as per item No 1 above, any model of size Wall /cabin fan 300 mm sweep painted with grey colour synthetic enamel paint complete all as specified and as directed .
Description same as per item No 1 above, any model of size Wall /cabin fan 400 mm sweep painted with grey colour synthetic enamel paint complete all as specified and as directed .
Taking down ceiling fan of any make any model of size 48" (1200 mm) sweep complete, dismantling and refixing the same after cleaning all parts of fan internally and externally and applying greasing, oiling of bushes and bearings etc and necessary replacement of all worn out parts such as Condensor , bush, bearing, , Rotor and repalcement of rubber real , mild steel U Clamp ,nut & bolts & Split pin and PVC insulated flexible cable for connection etc complete all as directed . Note:- for item No. 9 to 16 Note : (i) Fixing charges of worn out parts deemed to be included is unit quoted rate . (ii) Worn out parts shall be measured and paid separately as Supply only under respective items of this BOQ. (iii) The fixing arrangement of fan with existing GI pipe down rod including hanging in position after repair will be the responsibility of contractor and deemed to be included in unit rate quoted by the tenderer (iv) Testing of ceiling fan for 24 hrs running condition shall also be the rsponsibilty of contractor and this aspect deemed to be included in unit rate quoted by the tenderer.
All as per Srl item No 9 above but 56" (1400 mm) sweep.
Description same as per item No 9 above, but exhaust fan of any make or any model of size 9" (225 mm) sweep complete all as specified and as directed
Description same as per item No 9 above, but exhaust fan of any make or any model of size 12" (300 mm) sweep complete all as specified and as directed
Description same as per item No 9 above, but exhaust fan of any make or any model of size 15" (375 mm) sweep complete all as specified and as directed .
Description same as per item No 9 above, but exhaust fan of any make or any model of size 18" (475 mm) sweep complete all as specified and as directed . .
Description same as per item No 9 above, any model of size Wall /cabin fan 300 mm sweep complete all as specified and as directed .
Description same as per item No 9 above, any model of size Wall /cabin fan 400 mm sweep complete all as specified and as directed .
Supply & fixing in repair new blade white colour 1200 mm sweep with and including nut bolts for fixing suitable for Polar, Orient complete all as specified and as directed.
Supply & fixing in repair new blade white colour 1400 mm sweep with and including nut bolts for fixing suitable for Polar, Orient complete all as specified and as directed.
S&F in repair canopy (Top & bottom) for ceiling fans with screw to down rod complete all as directed.
S&F in repair electronic fan regulator 240 volts step type two module complete all as specified and as directed. Make :- Bajaj/ Polar/Khaitan
S&F in repair electronic fan regulator 240 volts step type one module complete all as specified and as directed. Make :- Bajaj/ Polar/Khaitan/Havells
Supply only ball bearing 6201. Make :- SKF/NBC.
Supply only ball bearing 6202. Make :- SKF/NBC.
Supply only ball bearing 6203. Make :- SKF/NBC.
Supply only Gun metal bush
M&L for Spary painting of celling fan of 1200mm sweep complete with one coat of white synthetic enamel paint after cleaning surfaces internally and exteranlly and including prepration to receive new coat of painting all as directed.
M&L for Spary painting of celling fan of 1400mm sweep complete with one coat of white synthetic enamel paint after cleaning surfaces internally and exteranlly and including prepration to receive new coat of painting all as directed.
M&L for Spary painting of exhaust fan 450mm with two coat of synthetic enamel paint after cleaning of internally and externally surfaces including prepration to receive new paint all as directed.
M&L for Spary painting of exhaust fan 300mm with two coat of synthetic enamel paint after cleaning of internally and externally surfaces including prepration to receive new paint all as directed.
M&L for Spary painting of exhaust fan 225mm with two coat of synthetic enamel paint after cleaning of internally and externally surfaces including prepration to receive new paint all as directed.
Supply only ‘U’ clamp with washers, split pins , rubbers bush etc as directed.
S&F in replacement of ‘U’ clamp with nut bolts, washers, split pins , rubbers bush and incuding hanging of ceiling fans in position etc complete and as directed.
Supply only condenser of 2.5 Mfd for ceiling fan of any make, any model and any sweep complete all as specified and as directed. Make :- Asian/Siemen.
S&F in repair condenser of 2.5 Mfd for ceiling fan of any make, any model and any sweep complete all as specified and as directed. Make :- Asian/Siemen.
Supply only condenser of 4 Mfd for ceiling fan of any make, any model and any sweep complete all as specified and as directed. Make : Asian/Siemen.
S&F in repair condenser of 4 Mfd for ceiling fan of any make, any model and any sweep complete all as specified and as directed. Make : Asian/Siemen.
M & L for Marking of MES No in arial font and size with stencil as approved with black synthetic enamel paint on painted surface of ceiling fan/exhaust fan complete all as specified and as directed.
Supply only rotor complete with copper winding suitable for 1200mm complete all as directed.
Supply only rotor complete with copper winding suitable for 1400mm complete all as directed.
S&F in repair outer cover (top) of fan suitable for 1200 mm fan suitable for , Polar, Khaitan complete all as specified and as directed.
S&F in repair outer cover (Bottom) of fan suitable for 1200 mm fan suitable for , Polar, Khaitan complete all as specified and as directed.
S&F in replacement of old unservisable of fan down rod ( Heavy duty ) 450 mm to 600 mm in length for ceiling fan as directed
S&F in repair outer cover (top) of fan suitable for 1400 mm fan suitable for , Polar, Khaitan complete all as specified and as directed.
S&F in repair outer cover (Bottom) of fan suitable for 1400 mm fan suitable for , Polar, Khaitan complete all as specified and as directed.
S & F in repair PVC insulated flexible cable 2 core with standed copper conductor of size 23.00/76 Sqmm against unserviceable flexible cable complete all as specified and as directed. Make : Plaza/Polycab/Kalinga/Finolex
Supply only PVC insulated flexible cable 2 core with standed copper conductor of size 40.00/76 Sqmm against unserviceable flexible cable complete all as specified and as directed. Make : Plaza/Polycab/Kalinga/Finolex
Supply only PVC insulated flexible cable 2 core with standed copper conductor of size 23.00/76 Sqmm against unserviceable flexible cable complete all as specified and as directed. Make : Plaza/Polycab/Kalinga/Finolex
S & F in repair PVC insulated flexible cable 2 core with standed copper conductor of size 40.00/76 Sqmm against unserviceable flexible cable complete all as specified and as directed. Make :Plaza/Polycab/Kalinga/Finolex
S & F wall mounting fan sweep 400mm pull cord oscillating type single piece AS blade 3 speed pull cord control complete all as specified and as directed. Make : “CG model No. WMSDX 120" )/ALMONRD/ bajaj
S & F exhaust fan sweep 300mm noiseless light-weight rust proof body self closing louvers and blades complete with all arrangement of making hole complete all as specified and as directed. Make : “CG model No. trans air12' "/ALMONARD/Bajaj
S & F Exhaust fan 375 MM sweep noiselss light -weight rust proof body self closing louvers and blades complete with all arrangment of making hole complere all as specfied and as directed . Make : CG model No. EXHD380-4-1 /ALMONARD/Bajaj
S&F Exhaust fan 450mm sweep noiselss light -weight rust proof body self closing louvers and blades complete with all arrangment of making hole complere all as specfied and as directed . Make : CG model No. EXHD450-4-3 or equivalent in /CG/Bajaj
S&F air circulator fan 250mm sweep noiselss light -weight rust proof body self closing louvers and blades complete with all arrangment of making hole complere all as specfied and as directed . Make : Havells /CG/Bajaj
M & L for taking down & overhauling of air circulator fan of any make any model complete, dismantling it and cleaning all parts of fan internally and externally and applying greasing, oiling of bushes and bearings including replacement of all worn out parts such as bush, bearing, burnt out winding including rewinding of air circulator fan with super enameled copper winding wire complete matching with required gauge, nuts and bolts, fan condenser and replacement of 23/0.0076 copper flexible cord twin core of suitable length not exceeding 1 meter length from ceiling rose to ceiling fan including spray painting of air circulator fan with one coats of white synthetic enamel paint including preparation of old painted surfaces, filling of all cavities etc with filler and rewriting fan MES number with black synthetic enamel paint including assembling all repair parts of fan and testing it for smooth functioning of size 24 and re-fixing on site, complete all as specified and as directed. Note :- Burnt out parts such as bush and bearing shall be measured and paid separately under respective items of schedule 'A'.
S&F celling fan 1200mm sweep complete AC single phases 230volts minimum 5 star rating connecting with flexible cable 3 core copper conductor of size 23.0/0076 of suitable length from celling rose complete all necessary arrangement of hanging of celling fan (GI Pipe hook etc) as specified and as directed. Make-CG model No. HS Plus -5 Star or equivaleint in khaitan/ Bajaj
S&F in replacement of old unservisable of frame with four legs suitable for 450 mm exhaust fan duly painted all as directed
S&F in replacement of old unservisable of frame with four iegs suitable for 300 mm exhaust fan duly painted all as directed
S&F in replacement of old unservisable of frame with four iegs suitable for 225 mm exhaust fan duly painted all as directed
S&F in replacement of old unservisable of fan blade with split pin suitable for 225 mm exhaust fan duly painted all as directed
S&F in replacement of old unservisable of fan blade with split pin suitable for 300 mm exhaust fan duly painted all as directed
Supply only nuts/ bolts of superior quality and of suitable size and dia for hanging /fixing ceiling all as directed
Supply only good quality of grease as approved by the Engineer In Charge .
m/s gupta trading
Hansraj Shivhare
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .