Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹39.3 L+₹2.7 L (7.25%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹42.8 L+₹6.1 L (16.7%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹4.4 L−₹32.2 L (87.9%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹48.2 L+₹11.5 L (31.4%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹48.8 L
EMD Value
₹97,600
Closing Date
11 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-24/2022-2023 ADDN/ALTN TO BLDG NO P-52 AND UPGRADATION ON BLDG NO P-590 AT CHANDIMNADIR
2022_MES_528535_4
GE/CHM-24/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer
₹97,600
Yes
13 Dec 2022
21 Oct 2022
18 Nov 2022
21 Oct 2022
11 Nov 2022
28 Oct 2022
Amount
Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water, complete all as specified and directed.
Dismantling floor hearth or wall tilling including cement mortar bedding, removing rubbish off the premises complete as specified and directed.
Demolition of plain cement concrete in ground floor and paving n.exc 15cm thickness below or above ground level complete all as specified and directed.
Dismantling of brick work, stone/ boulder masonry and built in cement mortar including all quoins arches, pillars etc , all as specified & directed by Engineer-in-charge.
Plain cement concrete 1:4:8, nominal mix, type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete, all as specified & directed.
Brick work with sub class ‘B’ bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 100 kg / Sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed.
All as per serial item No 6 herein before but except bricks
Brick work with sub class ‘B’ bricks of class designation 10 (min. compressive strength 100Kg/sqcm) old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed.
Plain cement concrete 1:2:4 type B-0 using 12.5mm graded aggregate as in roof kerbs or mud stops rounded or chamfered on edges, complete all as specified & directed.
Plain cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protections, 75mm thick, finished fair and even without using extra cement, with 10mm wide joints to full depth @ 3m c/c and at corners, filled with mastic mortar, complete all as specified and directed.
Reinforced cement concrete , 1:1½:3 (nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams etc, shelves and the like, complete all as specified and directed .
Mild steel high strength Deformed bar TMT 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified & directed.
Water tight steel centering and shuttering including bolting, strutting, propping etc as form work to column, beam etc complete, all as specified and directed.
Powder coated aluminum sections for door/window frame, shutters (openable or sliding), partition, ventilator etc with one or more rebates (wall thickness of aluminium section not less than 2mm) including jointing cleats for fixing etc, standard anodised aluminum section, powder coating not less than 50 micron, fixed in repairs, complete all as specified and directed
5mm thick sheet glass, fixed to aluminum frame work with standard anodized aluminum snap beading, rubber packing, aluminum screws etc in panels exc 0.5 Square metre in each pane, complete all as specified & directed.
Double action floor spring , hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of MS heavy duty, fixed in repairs, complete all as specified & directed by Engineer-in-charge.
Aluminium (extruded section body) door closer hydraulically regulated designation No. 3, universal type, suitable for door shutter of 851 mm to 1000mm in width and of weight between 61 to 80 Kg complete, fixed in repairs, all as specified & directed by Engineer-in-charge.
Aluminium door handles "D" type, anodized of size 200 mm, ISI marked, complete all as specified.
Aluminium handles, cast type anodized of size 150 mm, ISI marked, fixed in repairs, complete all as specified.
Single piece EWC with UF seat cover, hinges, fixing accessories set, cistern fitting , size 365x655x760mm and S-trap 300mm ,fixed in repairs, all as directed.
Single piece EWC with UF seat cover, hinges, fixing accessories set, cistern fitting , size 365x655x760mm and P-trap 180mm ,fixed in repairs, all as directed.
Glazed ceramic tiles, coloured in vertical surface 300mm x 450mm x 7mm, first quality, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Non skid ceramic coloured tiles, first quality, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 Square metre but not exceeding 0.18 Square metre, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Non skid ceramic coloured tiles, first quality, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.18 Square metre but not exceeding 0.38 Square metre, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
16mm thick granite slab (of any type & shade as approved), as on steps, jambs, cooking platform, counter slab etc (length and width as ordered by GE in one piece) best quality machine cut and jointed with grey cement slurry and pointed in white cement mixed with pigment (1:2) to match the shade of slab laid over and including 15mm thick screed bed in cement mortar 1:4 including nosing at edges , dismantling of existing tiles ,complete all as specified and directed.
16-18mm thick Baroda green marble (of any type & shade as approved), as on steps, jambs, cooking platform, counter slab etc (length and width as ordered by GE in one piece) best quality machine cut and jointed with grey cement slurry and pointed in white cement mixed with pigment (1:2) to match the shade of slab laid over and including 15mm thick screed bed in cement mortar 1:4 including nosing at edges , dismantling of existing tiles ,complete all as specified and directed.
16mm thick granite slab (of any type and shade as approved, length and width as ordered ), as in vertical surfaces of wall lining/ column face ,best quality machine cut and jointed with grey cement slurry and pointed in white cement mixed with pigment (1:2) to match the shade of slab laid over and including 10mm thick plaster in cement mortar 1:3, including nosing at edges , dismantling of existing tiles ,complete all as specified and directed.
Rendering 10mm thick in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement ,complete all as specified and directed
Rendering 15mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), including using water proofing compound , complete all as specified. Note : WPC shall be measured and paid separately.
Rendering 5mm thick in Cement and Sand mortar 1:3 concrete surfaces as in ceiling / chajjas facia at any position finished even and smooth without using extra cement , complete all as specified and directed.
One coat of white washing on old wall surfaces including preparation of surfaces, complete all as specified and directed.
One coat of white washing on old ceiling/chajja surfaces including preparation of surfaces, complete all as specified and directed.
Three coats of white washing on new ceiling/chajja surfaces including preparation of surfaces, complete all as specified and directed.
Two coats of oil bound distemper on new ceiling/chajja surfaces including preparation of surfaces, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer, complete all as specified and directed.
Complete removal of existiing treatment and preparation of old plastered / un-plastered surfaces of walls and applying one coat of cement base paint , complete all as specified and directed.
Complete removal of existiing treatment and preparation of old plastered / un-plastered surfaces of walls and applying one coat of exterior emulsion paint , complete all as specified and directed.
Preparation of old steel and iron surfaces over 10 cm width or girth and applying one coat of synthetic enameled paint ,complete all as specified and directed.
Two coats of synthetic enameled paint on steel and iron surfaces over 10 cm width or girth over a coat of red oxide including preparation of new surfaces, complete all as specified & directed.
Complete removal of existing treatment of any type / description viz distemper, white wash etc from existing plastered / unplastered surface of wall, chajjas,facia, cantilevers etc with mechanical means / grinder and applying wall care putty (average thickness 2mm as required for desired smoothness and leveling of surfaces in two or more layers) and sand papering, making the surfaces even and smooth and applying two coats of oil bound distemper over one coat of interior wall primer , complete all as specified and directed.
Preparation of new plastered surfaces and applying wall care putty (average thickness 2mm as required for desired smoothness and leveling of surfaces in two or more layers) and sand papering, making the surfaces even and smooth and applying two coats of interior emulsion paint over one coat of interior wall primer , complete all as specified and directed.
Complete removal of existing treatment of any type / description viz cement base paint, exterior emulsion, exterior texture paint etc from existing plastered / unplastered external surfaces of bldg with mechanical means / grinder completely and applying wall care putty (average thickness 2mm as required for desired smoothness and leveling of surfaces in two or more layers) and sand papering, making the surfaces even and smooth and applying two coats of exterior emulsion paint over one coat of primer, complete all as specified and directed.
Preparation of new surfaces of wall and applying wall care putty (average thickness 2mm as required for desired smoothness and leveling of surfaces in two or more layers) and sand papering, making the surfaces even and smooth and applying two coats of oil bound distemper, complete all as specified and directed.
20mm thick rendering in Cement and Sand mortar 1:4 over roof slab after cleaning and preparation of surfaces, complete all as specified.
3mm thick Atactic polypropylene polymer (APP) based polymeric membrane, minimum weight 3.0kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS . The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions, complete all as specified and directed.
Dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar including mud phuska as in roof of any thickness including plastering and leeping etc , removing any type of existing treatment ,complete all as specified and directed.
40mm thick brick tiles , joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on and including 20mm thick screed bed or bedding layer in CM(1:4), complete all as specified and directed.
All as per serial item No 47 herein before but except brick tiles .
PVC (SWR) pipe of 150mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc (spacing between two clamps not more than 2.50m) including taking down old pipe, complete all as specified and directed
150mm bore PVC (SWR) bends any radius including taking down old , complete all as specified and directed.
1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, screwable lid, hoisted and fixed in position, including tank nipple, PTMT 20mm dia ball valve, including dismantling of existing water tank and removing from site all as specified in SSR Part-I and all as directed by Engineer-in-charge.
Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 t , fixed in repairs, complete all as specified & directed by Engineer-in-Charge
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, fixed in repairs, all as specified and directed.
2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc, all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based corrugated coloured steel sheet 0.50mm thick ,having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified , all as specified and directed.
Plain cement concrete 1:3:6, type C-2 using 40mm graded stone aggregage as in roof padding, complete all as specified and directed.
Supply only integral water proofing compound (ISI Marked) complete all as specified & directed.
Chipping of loose/ damaged / cracked / previously repaired/ weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth n.exc 50mm , cleaning of reinforced concrete surface by air compressor , complete all as specified and directed.
Supply and apply rust remover cum passivator to remove rust from existing reinforcement by using Product : Rustoff-100 of Sika or equivaIent make in Fosroc / Thermax as approved by GE, with density 1.01 Kg/ltr at 30°C and consumption of 0.2 kg/Sqm per coat, complete all as specified and directed. Note : The material to be applied thoroughly on exposed reinforcement bars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.
Providing by mixing and trowel application of pre packed, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement with Sika Monotop 122F of Sika or equivalent make in Fosroc /Thermax as approved by GE with an average thickness exceeding 10mm and upto 25mm to the prepared concrete surfaces of soffit of slabs, beam, columns, parapets, fins and fascias at any height including finishing af applied Polymer mortar as per the technical specifications, complete all as specified and directed.
Providing by mixing and trowel application of pre packed, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement with Sika Monotop 122F of Sika or equivalent make in Fosroc /Thermax as approved by GE with an average thickness upto 10mm to the prepared concrete surfaces of soffit of slabs, beam, columns, parapets, fins and fascias at any height including finishing af applied Polymer mortar as per the technical specifications, complete all as specified and directed.
Supply and apply ready to use non shrink, cementious free flow micro concrete (<100mm) using Product : SikaRep(R) Microcrete-4 + adequate coarse aggregate, yield : approx 17 ltr/bag (30 kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep(R) Microcrete-4 or equivalent make in Fosroc/Thermax as approved by GE, Product requirements : compressive strength >60 N/Sqmm (28 days) according to ASTM C 1107-99, complete all as specified and directed.
Providing 15mm thick polymer modified plaster in ratio 1:10 over slab ( 1 part of polymer and 10 parts of cement with solid contents not less than 30%) and applying priming coat of epoxy primer with resin and hardner with water dilution as per manufacturer instructions, applying 1st coat of solvent based polyurathene liquid membrane not less than 500 micron thick @ 0.61 Kg/ Sqm and applying 2nd coat solvent based polyurathene liquid membrane not less than 500 micron thick @ 0.61 Kg/Sqm over dried 1st coat, complete all as specified and directed. Note : The works shall be carried out by approved applicator of Asian paints/ pidilite/ STP. Such agency shall have a valid authorization letter from the manufacturer.
Cement base polymer modified corrosion protection system (sikatop Armatec -108 of Sika or equivalent make in fosroc/ thermax as approved by GE ,carbonation resistance : 2 mm) to existing reinforcement with consumption @ 3.75 Kg/Sqm for two coats , complete all as specified and directed Note: The material to be applied throughly on exposed rebars only with the help of a brush of suitable size. the area will be measured as lenght of bar x two times the dia of bar.
Prepartation of old RCC surfaces, cleaning complete as per manufacturer's specification, providing, mixing and applying two component epoxy resin concrete bonding coat on prepared surfaces using product: Siladur-32 LP of Sika or equivalent ion fosroc/ thermax as approved by GE @ 0.4 Kg/Sqm, complete all as specifid and directed.
Rendering 1.0mm to 1.5mm thick dune /grit finish ready mixed product with natural stone granules (800, 1000 to 1200 micron) consisting of excellent synthetic/acrylic binder anti cracking anti foaming, anti fungal, anti rusting agent and applied directly over and including 15 mm thick rendering in CM(1:4) including taking down existing cement plaster, complete all as specified and directed.
Machine pressed, coloured precast concrete interlocking paver block, with grey cement and pigment, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 grade, set and jointed in neat cement slurry over 25mm thick sand cushion complete all as specified and directed
dhiraaj construction company
N.N.CONSTRUCTION
M/s Nuway Constructors India Pvt. Ltd.
Tejpal Singh and Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .