| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹21.9 L | L1 | Accepted-Finance LOWEST BIDDER |
| 2 | L2₹23.7 LRejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹23.7 L | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹26.0 LRejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹26.0 L | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹27.9 LRejected-Finance | ₹27.9 L | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | MOHAN LAL AND SONS L2 | slathia construction works L1 | PROACH ASSOCIATES BUILDERS & ENGINEERS L4 | ANIKET TRADERS L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Repair/maintenance of old unserviceable burnt out 11 KV PTs (Indoor type) copper wounding ratio three single phase of 11KV/3/110 V/3, class 0.5 - 3 with burden 5- VA and insulation level 28/75 confirming to IS - 3156 including taking out and disconnectin necessary connection complete all as specified and directed by Engineer-in-Charge. | 2 | Each | 1,500 ₹3,000 | 850 ₹1,700 | 2,000 ₹4,000 | 9,000 ₹18,000 |
| 2.00 | Repair/maintenance of old unserviceable burnt out 11 KV Resin cast CTs (Indoor type) copper wounding ratio 100-50/5+5, class 1.0, 5P, 10 burden as per IS - 2705 including taking out and disconnectin necessary connection complete all as specified and directed by Engineer-in-Charge. | 2 | Each | 1,500 ₹3,000 | 850 ₹1,700 | 2,000 ₹4,000 | 9,000 ₹18,000 |
| 3.00 | M&L for Aluminium conductor steel reinforced (ACSR) as in over head conductor fixed to insulators mounted on HT poles/Bus bars with aluminium tapes for binding complete all as specified & as directed by Engineer-in-Charge. | 2 | Qtl | 14,000 ₹28,000 | 9,500 ₹19,000 | 14,500 ₹29,000 | 12,300 ₹24,600 |
| 4.00 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including dismantling existing rusted sections all as directed by Engineer-in-Charge. | 1.5 | Qtl | 6,000 ₹9,000 | 5,500 ₹8,250 | 6,700 ₹10,050 | 8,000 ₹12,000 |
| 5.00 | M & L for servicing of 11 HT panel , detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components after drawout of VCB trolly and Testing for smooth operation manual/ remote after caliberation of relay trough OEM of VCB/Test wing of UPPCL and resetting & generation of testing report by the primary injection set for 11 KV VCB for OC/EF ,parameter of relay setting for healthy system, complete all as specified and directed by Engr-in-Charge by Engineer-in-Charge.
Note: Worn out spare parts shall be measured and paid separately | 5 | Each Job | 8,000 ₹40,000 | 5,000 ₹25,000 | 5,000 ₹25,000 | 3,000 ₹15,000 |
| 6.00 | S&F in repair/replacement of spring charging motor suitable of 11 KV VCB 110 V-230 Volt AC supply for the opening and closing of contacts complete all as specified and directed by Engr-in-Charge. | 3 | Each | 2,000 ₹6,000 | 7,500 ₹22,500 | 4,500 ₹13,500 | 1,200 ₹3,600 |
| 7.00 | S&F in repair/replacement of vaccum intrupter bottle as per existing capacity of VCB 110 V-230 Volt AC supply for the opening and closing of contactscomplete all as specified and directed by Engr-in-Charge. | 3 | Each | 3,500 ₹10,500 | 15,000 ₹45,000 | 12,000 ₹36,000 | 22,000 ₹66,000 |
| 8.00 | S&F in repair/replacement of Indicating lamp LED suitable for 11 KV as per existing capacity complete all as specified and directed by Engineer-in-Charge. | 10 | Each | 200 ₹2,000 | 150 ₹1,500 | 300 ₹3,000 | 111 ₹1,110 |
| 9.00 | S&F in repair/replacement of space heater 60 watt 230 Volt AC supply with thermostat complete all as specified and directed by Engineer-in-Charge. | 12 | Each | 1,500 ₹18,000 | 1,500 ₹18,000 | 2,200 ₹26,400 | 1,200 ₹14,400 |
| 10.00 | S&F in repair/replacement of digital voltmeter (0 to 12 KV size 96x96 mm class 0.5 , PTR 11000/rt3/110/rt3 complete all as specified and directed by Engineer-in-Charge. | 4 | Each | 600 ₹2,400 | 750 ₹3,000 | 900 ₹3,600 | 555 ₹2,220 |
Updated dates
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 Mar 2026, 6:00 pmClosed
HQ CWE AF Jammu
HQ CWE (AF) Jammu Air Force Station Jammu
CA NO CWEAFJ-47/2025-26 REPAIR/REPLACEMENT/MAINT OF HT UG/OVER HEAD ACSR CONDUCTOR/GODO/VCB/LBS/ACB AND RE-ROUTING/RE-LAYING OF HT CABLE ALONGWITH DEHYDRATION OF TRANSFORMER OIL/TOP UP/ REPLACEMENT OF TRANSFORMER OIL
2026_MES_754619_1
CA NO CWEAFJ-57/2025-26
Open Tender
Electrical and Maintenance Works
180 days
UDHAMPUR
As per NIT and Tender document
9 documents required · 9 mandatory
₹500
GE (AF) Udhampur
₹60,000
Yes
30 Apr 2026
27 Feb 2026
30 Mar 2026
27 Feb 2026
27 Mar 2026
13 Mar 2026
Repair/maintenance of old unserviceable burnt out 11 KV PTs (Indoor type) copper wounding ratio three single phase of 11KV/3/110 V/3, class 0.5 - 3 with burden 5- VA and insulation level 28/75 confirming to IS - 3156 including taking out and disconnectin necessary connection complete all as specified and directed by Engineer-in-Charge.
Repair/maintenance of old unserviceable burnt out 11 KV Resin cast CTs (Indoor type) copper wounding ratio 100-50/5+5, class 1.0, 5P, 10 burden as per IS - 2705 including taking out and disconnectin necessary connection complete all as specified and directed by Engineer-in-Charge.
M&L for Aluminium conductor steel reinforced (ACSR) as in over head conductor fixed to insulators mounted on HT poles/Bus bars with aluminium tapes for binding complete all as specified & as directed by Engineer-in-Charge.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including dismantling existing rusted sections all as directed by Engineer-in-Charge.
M & L for servicing of 11 HT panel , detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components after drawout of VCB trolly and Testing for smooth operation manual/ remote after caliberation of relay trough OEM of VCB/Test wing of UPPCL and resetting & generation of testing report by the primary injection set for 11 KV VCB for OC/EF ,parameter of relay setting for healthy system, complete all as specified and directed by Engr-in-Charge by Engineer-in-Charge. Note: Worn out spare parts shall be measured and paid separately
S&F in repair/replacement of spring charging motor suitable of 11 KV VCB 110 V-230 Volt AC supply for the opening and closing of contacts complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of vaccum intrupter bottle as per existing capacity of VCB 110 V-230 Volt AC supply for the opening and closing of contactscomplete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of Indicating lamp LED suitable for 11 KV as per existing capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair/replacement of space heater 60 watt 230 Volt AC supply with thermostat complete all as specified and directed by Engineer-in-Charge.
S&F in repair/replacement of digital voltmeter (0 to 12 KV size 96x96 mm class 0.5 , PTR 11000/rt3/110/rt3 complete all as specified and directed by Engineer-in-Charge.
M&L for repair to VCB/ RMU switch gears (of existing capacity) broken front and rear doors of existing size with suitable locking arrangements by using suitable hinges including necessary welding work complete all as specified and as directed by Engineer-in-charge.
M&L disconnecting all existig electrical connection from four pole structure & taking out unserviceable/burnout HT Jumper cable/conductor with nut, bolt, washer and Supply & fixing PVC insulated sheathed unarmoured stranded aluminium single core cable for HT Jumper of length not less than 2.5 m long in repair /replacement on existing OH circuit/two Pole /four Pole Structure etc including ACSR Conductor using PG clamp/lugs, fastners, aluminium lugs, GI nut, bolt, washer etc complete as per site requirment all as specified and directed by Engr-in-Charge.
M & L for horizontal boring under Road, pavement, hard standing complete for inserting GI pipe light grade of size 80/100 mm dia complete all as specified and directed by Engineer-in-Charge. Note :- GI pipe shall be measured and paid seperately
M & L for 80 mm dia of Tubes light grade galvanised with all fitting laid in trenches or inserting in horizontal boring complete all as specified and as directed by Engineer-in-Charge.
M&L taking out old unserviceable HT cable as per existing make and size for deducting of fault or any looping condition complete all as specified and directed by Engineer-in-Charge.
M&L taking down and Re-laying of HT cable of any size after rectify the fault or Laying of XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core 95 Sqmm to 3 Core 185 Sqmm laid in trenches / ducts / pipe or on poles complete all as specified and directed by Engineer-in-Charge.
Supply and laying or fixing jointing and testing 11 KV (E) system XLPE insulated, screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables ISI 7098 marked with aluminium conductor, 11000 Volts ( earthed), laid under floor/ground or fixed on wall complete of cable size 95 Sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
Supply and laying or fixing jointing and testing 11 KV (E) system XLPE insulated, screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables ISI 7098 marked with aluminium conductor, 11000 Volts ( earthed), laid under floor/ground or fixed on wall complete of cable size 120 Sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
M&L disconnecting and taking down old unserviceable cable of any description and capacity and M&L for on existing poles of Arial Bunched cable 11 KV grade, stranded and compact aluminium phase conductor of size 95 sqmm, 3 core (bare messenger/conductor) with aluminium alloy. The phase conductor should be insulated with XLPE Sioplas compound complete all as specified and directed by Engineer-in-Charge. Note :- The rated quoted shall be deemed to include the cost of fittings such as anchor clamps, suspension clamps, in line connectors, service clamps, insulation piercing connectors, tapping from bare lines etc. and nothing extra shall be admissible on this account.
M&L for cable jointing kit for 11 KV (E) grade cable for indoor end termination heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
Description all as per item No 22 here-in-before but size of indoor end termination 120 Sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
M&L cable jointing kit for 11 KV (E) grade cable for out door end termination heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
Description all as per item No 24 here-in-before but size of outdoor end termination 120 Sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
M&L cable jointing kit for 11 KV (E) grade cable for straight through heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
Description all as per item No 26 here-in-before but size of straight throught 120 Sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
Supply and fix arial bunched cable jointing kit for 11 KV grade cable for out door end termination heat shrink type joint complete with jointing material and accessories suitable for 1 core XLPE armoured Al conductor cable of size 95 sq mm x 1 Core including taking down old. NOTE:- Item rate quoted including required T&P/Refixing & Refilling in the panel/pole.
M & L for handling, transportation of transformers of capacity up to 400 KVA of any make, model & type including hoisting, taking down from pole (pole mounted) or plinth mounted by any means mechanically pulley/mechanical crane, transportation to workshop for repair/maint. Reinstallation of Transformer in position pole mounted/plinth mounted including connecting all cable, earth lead, clamps and channels etc as per site requirement all as directed by Engineer-in-Charge.
M&L labour only for opening of top cover and allied parts of transformer of capacity up to 1000 KVA lifting of Core for repair , preheating charges for copper coils, assy of core coil assy including assy of copper coils, Tapping connections , insulation on Tap leads with insulation paper ,star connection by new EC grade copper on HV & LV side , Baking charges for transformer job for each proper IR value in vacuum Chamber ( Auto Clave ) , refitting of HV / LV bushing and transformer accessories with top cover, M& L for painting of transformer tank having hot oil resistant paint inside complete all as specified and directed by Engineer-in-Charge. Note :- (i) If any damage to transformer/OH line/cables occur during handling, transportation or during hoisting/lifting, the same will be rectified by the contractor without any extra cost to the department. (ii) spare parts required at work shop like trasformer oil, core winding etc shall be measured and paid seperately under respective items of schedule.
M&L for changing of Old / Burnt Copper HV winding by new EC grade copper coils with complete including insulation material of transformer complete all as specified and directed by Engineer-in-Charge.
M&L for changing of Old / Burnt Copper LV winding by new EC grade copper coils including striping out of Insulation of LV Windings and reinsulation of Coil with insulating material of transformer for any type and capacity of transformers complete all as specified and directed by Engr-in-Charge.
M&L transformer oil having di-electric strength of 40 to 60 KV as per IS complete for top up/ replacement all as specified and as directed by Engr-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
M & L for dehydration/Filteration of transformer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Breakdown voltage should not be less than 50 KV complete all as specified and directed by Engineer-in-Charge.
M & L for disconnecting the transformer of capacity up to 400 KVA indoor/outdoor from HT/LT side carefully at site, for top overhauling of transformer dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, supply and replacing the 5 mm thick rubberised cork sheet gasket for tank top cover, repair of transformer oil leakages from HT/LT bushing,and reassembling the complete, reconnecting the HT/LT supply cable ends at the site and testing complete all as specified and directed by Engineer-in-Charge. Note : (i) If any damage to transformer/OH line/cables occur during handling, transportation or during hoisting/lifting, the same will be rectified by the contractor without any extra cost to the department. (ii) Spare parts required at site shall be measured and paid seperately under respective items. (iii) If T&P for lifting of material is required at site deemed to incude as unit rate.
Supply and fix LV porcelain bushing of transformer 1.1KV/250 Amp with metal parts brass as per IS 3347 part-III and 4 Nos hexagonal nuts, complete all as specified and directed by Engineer-in-Charge.
Description all as per ser item No 36 here-in-before but capacity 1.1KV 315 Amp complete all as specified and directed by Engineer-in-Charge.
Description all as per ser item No 36 here-in-before but capacity 1.1KV 630 Amp complete all as specified and directed by Engineer-in-Charge.
Supply and fix HV porcelain bushing of transformer 11 KV with metal parts brass as per IS 3347 part-III and IS 2009, complete all as specified and directed by Engineer-in-Charge.
M&L for hammer tone spray painting of transformer 11 KV/433 volts indoor/outdoor type of capacity 100 KVA to 160 KVA, including cleaning, scraping of exposed surfaces with shade as approved including writing MES number and machine number with black paint, letters 15mm wide and 50mm height complete all as specified and directed by Engineer-in-Charge.
Description all as per ser item No 40 here-in-before but capacity 200 KVA to 250 KVA complete all as specified and directed by Engineer-in-Charge.
Description all as per ser item No 40 here-in-before but capacity 300 KVA to 400 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair digital temperature meter Flush type (CT operated ) complete all as specified and directed.
Supply and replacement of silica gel breather assembly of capacity 400 KVA complete all as specified and as directed by Engineer-in-Charge.
Description all as per ser item No 44 here-in-before but capacity 250 KVA to 315 KVA complete all as specified and directed by Engineer-in-Charge.
Description all as per ser item No 44 here-in-before but capacity 63 KVA to 200 KVA complete all as specified and directed by Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge.
M&L for Comprehensive maintainance / testing of 11 KV RMU as per existing make including painting as per existing colour and checking of circuit wiring, tightening of loose connections, replacement of burnt out wiring thimbles , setting of numerical relays O/C & E/F , ensuring health test by primary injection at site including minor spare parts etc and submission of test report to the Engr - in - charge complete all as specified and directed by Engineer-in-Charge. Note : Spare parts shall be measured and paid seperately
S&F in repair/replacement of spring Charging Motor suitable of 11 KV RMU 110 V-230 Volt AC supply for the opening and closing of contacts complete all as required and directed at site complete all as per sample.
S & F in repair over current earth fault relay suitable for 11 KV RMU as per existing make /model/capacity complete all as specified and directed by Engineer-in-Charge.
M&L for repair spout for breaker as per existing make/model/capacity complete all as specified and directed by Engineer-in-Charge.
M&L for repair interlocking arrangement of bush between A & K mechanism as per existing make/model/capacity complete all as specified and directed by Engineer-in-Charge.
M&L for repair interlocking arrangement of handle for RMU as per existing make/model/capacity complete all as specified and directed.
S &F in repair Voltage presence indicator as per existing make/model complete all as specified and directed by Engineer-in-Charge.
Supply and fixing set consisting of 3 HV- Back up fuse Link for three phases indoor type conforming to IEC 60282-1 suitable for fixing in 11 KV RMUs (for load up to 250 KVA) of current rating (capacity) 10A having short circuit rating not less than 63KA Make ABB Cat No 1YMB531035M0002 or equivalent complete all as specified and directed by Engineer-in-Charge.
Supply and fixing set consisting of 3 HV-Back up fuse Link for three phases indoor type conforming to IEC 60282-1 suitable for fixing in 11 KV RMUs (for load up to 250 KVA) of current rating (capacity) 16A having short circuit rating not less than 63KA Make ABB Cat No 1YMB531035M0003 or equivalent complete all as specified and directed by Engineer-in-Charge.
Supply and fixing set consisting of 3 HV-Back up fuse Link for three phases indoor type conforming to IEC 60282-1 suitable for fixing in 11 KV RMUs (for load up to 250 KVA) of current rating (capacity) 25A having short circuit rating not less than 63KA Make ABB Cat No 1YMB531035M0004 or equivalent complete all as specified and directed by Engineer-in-Charge.
M & L for Cleaning of the area with removing the green grass patches /Bushes/small ornamental plants/herbs from the complete area of 33 KV receiving station with suitable T&P and covering the area with suitable peables of suitable size dressing/cleaning the area complete and afterwards sparying the complete area with suitable herbicide to stop the growth of weeds and grass as desired and directed by Engr-in-charge. ( Note: the complete Job will be done only after taking proper shut down of 33 KV HT Line. Shut Down will provided by the Dept. with Liasion of SED.) Note: Rate of cleaning of area to be done once in a three months is seemed to be included in quoated rate.
M&L in repair, testing and commissioning of air break gang operated switch, triple pole mechanically operated out door type with all fittings/accessories mounted on and including 11 KV HT 15 Nos porcelain insulators of rating up to 200 Amps complete with drop out fuse assy having fuses of rating 40 Amps and steel channel frame, GI operating rod 25 mm dia of suitable length with operating mechanism worked form ground level, vertically operated including locking arrangement & operating handle, with and including padlock complete all as specified and as directed by Engr-in-Charge.
Supply and fixing lightning arrestor of 09 KV metal oxide (Gap less type) heavy duty, self supporting station class having nominal discharge current 10 KA (peak), class II , insualation level 70/170KV suitable for 11 KV supply including necessary connections with complete all as specified and directed by Engineer-in-Charge.
S&F in repair/replacement of male contact / moving contact blade and fix contact jaw 200 / 400 amp , Tinned copper flexible jumper for GOD 11 KV per phase complete all as specified and directed by Engineer-in-Charge.
S&F in repair/replacement of 11 KV Post insulator Porclain / Polymer complete all as specified and directed by Engineer-in-Charge.
Preparation of old painted surface and painting of steel tubular HT poles 11 mtr long from bottom to top incl all iron structure in Zebra pattern 30 cm wide, with synthentic enamelled paint in black and yellow colour up to 1.2 metre height from pedestal, including painting of steel structure, cross arms, bracings, supports, clamps and back plates (all metalic parts) of Steel Tubular pole complete, with two coats of Spray aluminium paint including preparation of old painted steel surfaces with zinc oxide primer with including writing letters/ numbers in both side of pole MES,LT/HT and pole No complete all as specified and directed by Engr-in-Charge.
M & L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of pole / for ducting/LT Panel with necessary form work complete all as specified and directed by Engr in charge.
M&L for type PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in coping etc for pole / ducting/LT Panel including necessary form work complete all as specified and directed by Engr in charge.
Supply and errect steel tubular, sewaged pole, 11 Mtr long type 410-SP-55 complete with cast iron base plate, finial taper plug, bolts, nuts and screws duly painted with two coats anti corrosive paint internally complete and externally upto planting depth alternate black and yellow straps of synthetic enamel paint 30 cm each up to 1.5 mtr from GL and remaining pole painted with aluminium paint including writing No complete all as specified and directed by Enge-in-Charge.
Material and labour for earthing complete with copper steel earth plate electrode 60 cm x 60 cm x 3.15 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to copper earth strip 20 x 3 mm size (upto 7.5 metre from ground electrode) by means of copper/brass bolts, nuts, check nuts and washers all as shown in electrical plate No.3 of MES Schedule Part-I, connected to earth test terminal block and testing on completion with and including 40mm bore light grade GI protection pipe for strip upto plingth protection, PCC pit in mix 1:3:6 type C1, with RCC 1:2:4 type B-1, 40 mm thick cover, reinforced with 6 mm dia MS bars 3Nos. both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore medium grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work complete.
M & L for replacement of chemical earthing comprising copper earth plate electrode 900 x 600 x 5 mm thick burried directly in ground, earth pit not less than 3.10 metres below normal ground level and complete size of pit shall be 1.60 m x 1.60 m x 5.10 metres, with top edge of the plate not less than 3.75 metres below normal ground level, earth plate surrounded from all sides by 20 cm thick salt and charcoal dust and Magnisium sulphate filling in alternate layers of 20 cm thick up to 1.8 metres height and including connected to copper strip 50 x 6 mm (upto 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 65 mm bore light grade pipe from electrode and upto, 15 mm bore watering pipe light grade GI funnel, wire mesh, earth plate surrounded from all sides by 20 cm thick salt (40 Kg), charcoal dust (40 Kg) and Magnisium sulphate (50 Kg) filling in each alternate layers upto 1.80 m height including excavation, removal surplush soil to a distance not exc. 50 m, complete all as specified and directed by Engineer-in-Charge.
supply and pouring of RoHS tested Earth Enhancement Compound after mixing with water tested by NABL accredited lab in compliance to IEC 62561-7 or its latest IEC code with a resistivity <0.12 ohm -m. It shall be free from bentonite and other hazardous substance , It shall be a permanent, non corrosive material and will not leach any chemical into the ground. It shall retain moisture even in highsoil resistivity areas. complete all as specified and as directed by Engineer-in-Charge.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 20x3 mm copper strip complete all as specified and directed by Enginer-in-Charge.
M & L for brazing/Welding work with GI brazing/Welding alloy rod with the help of oxygen and LPG cylinder using required Galvanised Iron of size 20 mm x 3 mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper all as specified and directed by Engineer-in-Charge.
M & L for brazing/Welding work with copper/Welding alloy rod with the help of oxygen and LPG cylinder using required Copper of size 20 mm x 3 mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper all as specified and directed by Engineer-in-Charge.
Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc or /getting out cable cover and stacking for reuse/ credit , trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil nexc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for dry sand cushioning to underground cables with 8 cm thick before laying of cables and 15 cm thick after laying and stretching of Cable complete all as specified and directed by Engineer-in-Charge. Note : Only punned thickness i.e. 18 CM shall be measured and paid.
Supply and laying un-reinforced precast concerete cable caver, class HVP, type 2 flat size 250mm xm 150mm x 40 mm for covering to under ground cable laid flat transversally width equal to the lenth of the cable complete all as specified and directed by Engineer-in-Charge.
M&L SF6 gas for rifilling in electrical switchgears including disconnecting and refixing the same after complete the job complete all as specified and directed by Engineer-in-Charge. Note : Cost of T&P shall be inclusive as unit rate.
S&F in repair/replacement of HT 11 KV tape 20mm width and 25 Mtr length in different colour complete all as specifed and directed by Engineer-in-Charge.
S&F in repair/replacement of tinned fuse wire 22 guage or as required at site complete all as specified and directed by Engineer-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
57.pdf
Tender Documents • 1.19 MB
BOQ_845206.xls
BOQ • 0.77 MB
Download all tender documents and submit your bid