Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
15 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIRS TO LT OH LINE, LT UG CABLE, LT PANELS, STREET LIGHTS AND REPAIRS / RENEWAL OF DAMAGED WATER SUPPLY DISTRIBUTION LINE AND ALLIED WORKS AT UNIT 289 AND UNIT 729 UNDER GE (U) SECUNDERABAD.
2025_MES_736875_1
GE (U)/SEC/TOKEN/40 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
All as per Tender Document
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹1 L
Yes
25 Oct 2025
25 Oct 2025
22 Nov 2025
25 Oct 2025
15 Nov 2025
8 Nov 2025
Material and Labour in replacement for drawing two runs of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm including 20mm dia HDPE pipe conduit of dia 20 mm medium grade exclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified
Supply and lay in replacement PVC Insulated, PVC sheathed industrial HV round multicore flexible cable with copper conductor THREE core 2.5 sqmm including HDPE pipe 20 mm dia medium grade and necessary bends, fittings and fixtures as required for connection of light fittings. (USED FOR GARDEN LIGHT CONNECTION, EXCAVATION, RETUNING FILLIING ETC WILL BE MEASURED AND PAID SEPARATELY.
Supply and lay PVC Insulated, PVC sheathed industrial HV round multicore flexible cable with copper conductor THREE core 1.5 sqmm as required for connection of light fittings.
per span
S&F in replacement micro processed MCCB Adjustable over load, Short Circuit, Ground Fault of following sizes:
160 Amps 4 pole 36KA release range 100 - 160 Amps
400 Amps 4 pole 36KA release range 250 - 400 Amps
Taking out and Relaying of LT cable of size 10sq mm to 50 Sqmm 2/ 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge. Note: (Earth work, sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevant Item)
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/ Steel pole, laying of cable in trenches etc and getting out in Hard / Dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of size 210 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed.
Laying only old Brick in trenches for Under Ground Cable Protection (Serviceable Materials obtained from Items here-in-before), complete all as directed.
M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for filling & foundation of pole & stay and coping of valve chamber complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole, filling of footpath / road complete all as specified and directed by Engr-in-Charge.
M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paint including thoroughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia) and two meter length, The electrode should be of galvanised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m. The GI Electrode shall be pre-filled with Crystalline Conductive Material (CCM). The GI electrode shall be surrounded with 25 kg Backfill compound to provide maximum contact between the electrode and Back Fill Compound. The earthing pit cover should be factory built (size TOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch) made of heavy duty Polypropylene complete all as specified and directed.
S&F in replacement galvanised steel strip 32X6 mm with saddles and fixing screws on porcelain insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/ wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
All as per item No 50.00 above but 70/ 72 watts.
All as per item No 50.00 above but 60 watts.
M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100 Volts grade, over head/ underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
Replacement of worn out jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/ two wire or 3 phase/ 4 wire system will be considered as one job for payment purpose.
Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes.
Taking down old unsv Street light / flood light fittings in any position of any capacity for Repair by replacement of unsv spares (SPD / Driver / Mcpcb etc) and re-fixing the same in existing location. Note:- Spares for repair of street light fittings will be measured and paid under respective items.
M&L in replacement for Shackle type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 Volt grade, section of straps 31x5 mm, including disconnecting/ taking out old existing unsv insulators complete all as specified and directed.
S&F in replacement of LED Driver of similar wattage with operating voltage input ac 85- 300 volt, pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 100
watts LED flood light fittings of any make complete all as specified and directed.
S&F in replacement of LED Driver of similar wattage with operating voltage input ac 85- 300 volt, pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 120 watts LED flood light fittings of any make complete all as specified and directed.
S&F in replacement of LED Driver of similar wattage with operating voltage input ac 85- 300 volt, pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 150 watts LED flood light fittings of any make complete all as specified and directed.
S&F in replacement of LED Driver of similar wattage with operating voltage input ac 85- 300 volt, pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 200 watts LED flood light fittings of any make complete all as specified and directed.
Supply and fix in replacement ing steel light bracket made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified.
S&F in replacement PVC insulated unsheathed/ sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/ 1990 with latest amendments ISI including disconnecting/ taking out existing unsv/ damaged old service cable complete all as specified and directed.
All as per item No 102.00 above but of size 6 Sqmm complete all as specified and directed.
Supply and lay in replacement in trenches/ fixed to walls/ poles etc connecting buy using lugs, testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor 4 Core 10 Sqmm complete all, as specified and directed Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item no 104.00 above but 2 Core 10 Sqmm
All as per item no 104.00 above but 4 Core 16 Sqmm
All as per item no 104.00 above but 4.0 Core 25 Sqmm
All as per item no 104.00 above but 3.5 Core 35 Sqmm
All as per item no 104.00 above but 3.5 Core 50 Sqmm
All as per item no 104.00 above but 3.5 Core 70 Sqmm
All as per item no 104.00 above but 3.5 Core 95 Sqmm
All as per item no 104.00 above but 3.5 Core 120 Sqmm
All as per item no 104.00 above but 3.5 Core 150 Sqmm
All as per item no 104.00 above but 3.5 Core 185 Sqmm
S&F in replacement of hot press moulded SMC junction/ terminal box of size with internal dimensions of 24 x 19 x 11 with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or Bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/ glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3 mm 2 Set including dismantling of old unserviceable all as specified and as directed.
Supply and laying in replacement GI tubing light grade of size 40 mm for cable protection on road/ drain/ floor/ pole including necessary clamps 40x4mm all as specified and as directed.
Supply and laying in replacement GI tubing light grade of size 50 mm for cable protection on road/ drain/ floor/ pole including necessary clamps all as specified and as directed.
Supply and laying in replacement GI tubing light grade of size 80 mm for cable protection on road/ drain/ floor/ pole including necessary clamps all as specified and as directed.
16 to 25 Sqmm Size
S&F in replacement LT line rigid PVC Spacers spiral type, two lines, Phase to phase distance 300 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
70 to 95 Sqmm Size
120 to 150 Sqmm Size
185 to 240 Sqmm Size.
S&F in replacement LT line rigid PVC Spacers spiral type, three lines, Phase to phase distance 600 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
S&F in replacement LT line rigid PVC Spacers spiral type, four lines, Phase to phase distance 900 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
Supply in replacement of aluminium cable lugs of following sizes :-
Attending routine complaints of external water supply including rectification of minor defects by taking down of existing GI/ PPR tubing up to 25 mm bore, cutting/ threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of jumper valve/ packing sheet of gate valve and including replacement of GI unions/ sockets/ nipples etc as required at site complete all as specified and directed.
35 to 50 Sqmm Size
Repair/ rectification of leakages to water supply distribution lines 15 mm bore to 25 mm bore GI/ PPR tubing with provision of necessary excavation, cutting of hard standing, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/ sockets/ nipples as required at site complete all as specified and directed.
All as per item No 113.00 above but for GI tubing 40 mm bore to 50 mm bore
All as per item No 113.00 here-in-before but for GI tubing 80 mm bore to 100 mm bore.
All as per item No 116.00 above but for GI tubing 40 mm bore to 50 mm bore.
Attending complaints of BLOCKAGE OF WATER PIPE LINES / NO WATER SUPPLY AT ANY kind of ACCOMODATION (MARRIED / OTM/ single / multi story building) , IDENTIFY THE FAULTS including rectification by taking down of existing GI/ PPR tubing up to 80 mm bore, cutting/ threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of valve/ packing sheet of gate valve and including replacement of GI unions/ sockets/ nipples etc as required at site TO RESTORE WATER SUPPLY complete all as specified and directed.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Refixing of old steel tubing and connection in new or old position including cutting threads if required, fittings with old/ new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Refixing of old steel tubing and connection in new or old position including, cutting threads if required, fittings with old/ new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Notes for Sl item No 113.00 to 118.00 :- (a) The contractor will be allotted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/ her for completion of day to day complaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log book of complaints with completion/ non-completion remarks from users/ MES will be maintained by the contractor and the same will be updated on daily basis in consultation with JE E&M/ Engr-in-Charge. (c) The contractor will make suitable arrangement for emergency complaints and will notify authorised representative/ Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/ fittings utilized as per inventory format given by AGE E/ M, Secunderabad and the same shall be submitted to E/ M No II store yard on requirement basis. (g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work above 1 CUM measured and paid separately under relevant items . j) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution. (k) Spares/ GI fittings required to be replaced and shall be measured and paid separately under respective items.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Rectification of leakages in pumping / delivery lines(CI/ DI/ PPR/ MS) of size 40 mm to 100 mm at Military area / Military Roads / civil Roads / PWD Roads / Cantt board roads by taking necessary permission from respective authorities by excavating PCC/ RCC/ pavement/ soft&hard soil/ rock of any depth by using
necessary T&P(Excavator/ hammer drill)as per the requirement, De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/ tail peaces, any type of gasket, welding work etc as required to arrest the leakages completely and making joints, filling the trenches, site clearances and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/ CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation and PCC will be measured and paid separately under relevant items. (iii) rate of any kind of gasket and Lead joint, necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required. (v) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution.
Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for re-fixing or removal complete with all fittings and connections of the following sizes :- Note: Excavation & earthwork will be measured and paid separately.
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:- Note: (a) Excavation and Earth work shall be measured and paid separately.
necessary T&P(Excavator/ hammer drill)as per the requirement, De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/ tail peaces, any type of gasket, welding work etc as required to arrest the leakages completely and making joints, filling the trenches, site clearances and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/ CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation and PCC will be measured and paid separately under relevant items. (iii) rate of any kind of gasket and Lead joint, necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required. (v) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution.
Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for re-fixing or removal complete with all fittings and connections of the following sizes :- Note: Excavation & earthwork will be measured and paid separately.
Supply and laying steel water tubing medium grade, galvanised with all fitting, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:-
necessary T&P(Excavator/ hammer drill)as per the requirement, De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/ tail peaces, any type of gasket, welding work etc as required to arrest the leakages completely and making joints, filling the trenches, site clearances and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/ CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation and PCC will be measured and paid separately under relevant items. (iii) rate of any kind of gasket and Lead joint, necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required. (v) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution.
Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for re-fixing or removal complete with all fittings and connections of the following sizes :- Note: Excavation & earthwork will be measured and paid separately.
Taking up or down PPR pipe and connections, including cleaning the pipes free from scaling for re-fixing or removal complete with all fittings and connections of the following sizes :- Note: (a) Excavation and Earth work shall be measured and paid separately.
necessary T&P(Excavator/ hammer drill)as per the requirement, De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/ tail peaces, any type of gasket, welding work etc as required to arrest the leakages completely and making joints, filling the trenches, site clearances and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/ CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation and PCC will be measured and paid separately under relevant items. (iii) rate of any kind of gasket and Lead joint, necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required. (v) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution.
Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for re-fixing or removal complete with all fittings and connections of the following sizes :- Note: Excavation & earthwork will be measured and paid separately.
32 mm dia
necessary T&P(Excavator/ hammer drill)as per the requirement, De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/ tail peaces, any type of gasket, welding work etc as required to arrest the leakages completely and making joints, filling the trenches, site clearances and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/ CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation and PCC will be measured and paid separately under relevant items. (iii) rate of any kind of gasket and Lead joint, necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required. (v) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution.
Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for re-fixing or removal complete with all fittings and connections of the following sizes :- Note: Excavation & earthwork will be measured and paid separately.
63 mm dia
80 mm Dia
100 mm Dia
Refixing of old PPR Pipe and connection in new or old position including fittings with old/ new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
200 mm Dia
Refixing of old PPR Pipe and connection in new or old position including fittings with old/ new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
300 mm Dia
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings laid in trenches of following sizes including all fittings. Make : SFMC/ WETFLOW/ SAFE. Note: (a) Excavation and Earth work shall be measured and paid separately.
80 mm dia
100 mm dia
150 mm dia
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings fixed complete to walls, ceilings or in floors etc of following sizes including all fittings. Make : SFMC/ WETFLOW/ SAFE.
Taking up unserviceable/ defective CI/ DI/ MS/ PPR water mains (including all fitting) with spigot/ socketed / flanged ends including disconnecting pipes and fittings in any position complete all as specified and directed for the following sizes:- Note: (a) Excavation and Earth work shall be measured and paid separately.
150mm Dia
250 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
150mm Dia
Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI / DI specials, Joints and Earth work shall be measured and paid separately under relevant items of this schedule.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm Dia
Refixing of old CI/ DI/ MS Pipe and connection in new or old position including fittings with old/ new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:- Note: (a) Excavation and Earth work shall be measured and paid separately.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
200 mm dia
250 mm dia
Union
All equal Tee
Reducer Tee 20 x 20 x 15 mm
Socket
Reducer Socket 20 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer Elbow 20 x 15 mm
Elbow
200 mm dia
300 mm dia
Union
All equal Tee
Socket
Reducer Socket 25 x 20 mm
Reducer Socket 25 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer Elbow 25 x 20 mm
Reducer Elbow 25 x 15 mm
Reducer tee 25mm x 25 mm x 20mm
Reducer tee 25mm x 25 mm x 15mm
200 mm dia
S&F ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/ 2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/ 2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/ DI/ MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:- Notes:- (a) Quoted rates inclusive of Push on Joints / D-Joints as required (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required. (c) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution.
Union
All equal Tee
Socket
Reducer Socket 40mm x 25 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 40mm x 25mm
Reducer tee 40mm x 40mm x 25mm
Reducer tee 40mm x 40mm x 20mm
200 mm dia
Reducer Socket 40mm x 20 mm
Reducer elbow 40mm x 20mm
Supply only GI fittings 15 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer Socket 50mm x 40mm.
Reducer Socket 50mm x 25mm.
Elbow
Reducer elbow 50mm x 40mm
Reducer elbow 50mm x 25mm
Reducer tee 50mm x 50 mm x 40mm
Reducer tee 50mm x 50 mm x 25mm
Reducer tee 50mm x 50 mm x 20mm
200 mm dia
Hex Nipple
Union
All equal Tee
Socket
Reducer Socket 80mm x 50mm.
Reducer Socket 80mm x 40mm.
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 80mm x 50mm
Reducer elbow 80mm x 40mm
Reducer tee 80mm x 80mm x 50mm
Reducer tee 80mm x 80mm x 40mm
200 mm dia
All as per item No 134.00 above but for 20 mm bore.
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
All as per item No 134.00 above but for 25 mm bore.
All as per item No 134.00 above but for 40 mm bore.
20mm dia bore
25mm dia bore
All as per item No 134.00 above but for 50 mm bore.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
All as per item No 134.00 above but for 80 mm bore.
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
65mm dia bore.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Supply and fix in replacement of unserviceable ball brass valves, high pressure with polythene float and flynut alongwith socket/ reducer of suitable size, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
M&L for Arresting leakages of sluice valves by replacing Gland packing, gland bush, gland falange, nutbolts, gasket, packing material as required after dismantling in existing position including testing on completion complete all as specified and directed for the following sizes:- Note: Quoted rates inclusive of the materials mentioned above like Gland packing, gland bush, gland falange, nutbolts, gasket, packing material etc as required to arrest the leakages.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F CI / DI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
All as per item No 34 above but for 200 mm bore to 300 mm bore.
150 mm Dia
200 mm Dia
Burning out lead joint in position for following sizes of CI/ DI pipe, removing old lead complete all as specified and directed :-
150 mm Dia
200 mm Dia
M&L for run lead joint for CI pipe/ DI pipe including spun yarn etc for spigot and socket pipes and fittings complete all as specified and directed for the following bore of pipes:-
S&F in repairs CAST IRON OR DUCTILE IRON MECHANICAL COUPLING / MECHANICAL JOINT / D JOINT heavy duty INCLUDING ALL JOINTING MATERIAL, ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/ CI/ DI/ GI / PVC pipes of following sizes AS REQUIRED FOR REPAIRING OF ANY KIND OF LEAKAGES COMPLETE all as specified and as directed:- Notes:- (a) Excavation and Earth work shall
be measured and paid separately. (b) Quoted rate inclusive of cutting of any kind of pipes and all ITEMS as required for fixing and proper functioning of Joints. (c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account.
Supply and fixing in replacement of DI D/ F Gate valve (Soft Sealed) Resilient Seated Soft Sealing gate valves(Sluice valves RAISING TYPE ) with body bonnet of ductile cast iron of grade GGG-40/ SG- 400/ 15 or GGG-50/ SG-500/ 7 or equivalent grade as per IS 3896 - Part 2- 1985 and subsequent revisions, Wedge fully rubber lined with EPDM Food grade quality and Seals of NBR and the valve should be vacuum tight and 100 % leak proof with face to face dimension as per BS 5163-89/ IS 14846-2000/ DIN 3202 F 4. and Valves should be electrostatic powder coating both inside and outside pocket less body passage class PN 1.6 including all jointing materials (Gasket, Nutbolts etc) connecting and testing complete all as specified and directed.
S&F in repairs CAST IRON OR DUCTILE IRON MECHANICAL COUPLING / MECHANICAL JOINT / D JOINT heavy duty INCLUDING ALL JOINTING MATERIAL, ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/ CI/ DI/ GI / PVC pipes of following sizes AS REQUIRED FOR REPAIRING OF ANY KIND OF LEAKAGES COMPLETE all as specified and as directed:- Notes:- (a) Excavation and Earth work shall
100 mm Dia
Supply and fix NRV including making provisions in existing pipeline of CI/ DI/ MS of the following sizes completed all as directed. Note : Quoted rates inclusive of all arrangement required for the above
S&F in replacement of Cast Iron sluice valves flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, rising type K506, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed.
S&F, connecting and testing in repair of Cast Iron non return (Reflux) valves flanged ends in swing type design IS-5312 part-I, K517, PN-1.6 both ends flanged etc including jointing materials of following sizes complete all as specified and directed.
65 mm Dia
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F, connecting and testing in repair of Cast Iron foot Valves flanged ends swing type operation with rubber seat as per IS : 4038 single disc with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as specified and directed.
50 mm Dia
M&L for Construction of new PCC solid Masonry valve chamber of size 1500 X 1500 X 1500 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets around over 100 mm thick hard core, 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/ Dense soil 3 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L for Construction of new PCC solid Masonry valve chamber of size 900 X 900 X 900 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets around over 100 mm thick hard core, 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/ Dense soil 3 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L for painting of water distribution header including all control valves and all exposed pipe of any size by using synthetic enamelled spray painting after scrapping / cleaning complete all as directed .
Repairing of Sluice valves raising / non raising types after dismantling the same by replacing stem, gate/ disc, stuffing box, Seat, Gland packing, gland bush, gland falange, nutbolts, gasket, packing material, threading, welding as required for proper functioning of Sluice valves complete all as directed. Note: Quoted rates inclusive of all the materials mentioned above like stem, gate/ disc , Seat stuffing box Gland packing, gland bush, gland falange, nutbolts, gasket, packing material etc as required for proper functioning of the valves
Supply and lay Pipes MS black ERW Steel including specials having nominal dia 100 mm of thickness 6.0 mm as per IS 3589 - 2001, Grade - 330 with plain ends and specials by welding, leak testing of line laid in trenches / floors/ walls / ducts complete all as specified and directed. Note: Quoted rate is inclusive of supply and fixing of flange of suitable size as required, bends welding and cutting etc as required for fixing of pipe .
Supply and lay Pipes MS black ERW Steel including specials having nominal dia 150 mm of thickness 6.0 mm as per IS 3589 - 2001, Grade - 330 with plain ends and specials by welding, leak testing of line laid in trenches / floors/ walls / ducts complete all as specified and directed. Note: Quoted rate is inclusive of supply and fixing of flange of suitable size as required , bends, welding and cutting etc as required for fixing of pipe .
M&L in replacement for rewinding the centrifugal/ Monoblock electric motor starter or rotor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed of following capacities :- NOTE : Quoted rates inclusive of dismantling, refixing and transportation
Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity 3 HP to 10 HP and taking out the pump set alongwith pipes and fittings for flushing the bore well up to 450 feet depth or repair the pump set and strip opening the pump set for repairs/ replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed. Note :- The spares required for repair the pump sets and rewinding of motors will be measured and paid separately.
M&L for rewinding the Submersible pump Motor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed for Submersible pump motor of following capacity :-
Submersible Motor up to and including 5 HP.
Submersible Motor above 5 HP up to 10 HP.
Supply and fixing in replacement the following spares suitable for existing make of submersible pump set 3 to 10 HP capacity, multi stage for repairs complete all as specified and directed by Engr-in-Charge :-
Gun metal Impeller.
Stage casing.
SS Sleeves.
Middle bush.(LB)
Middle sleeve.
Discharge outlet.(LB)
Pump coupling.
DOL SS Sleeve.
Suction bush.
Pump Shaft
Supply and replace heavy duty long socket suitable for 50 mm dia heavy duty GI pipe complete all as specified and directed
Complete removal of existing treatment including preparation of old painted surfaces by washing, rubbing down and stopping of painted surfaces, painting with one coat of synthetic enamel paint of approved colour on centrifugal pump set of 3 HP to 10 HP capacity including inlet, outlet mains, couplings, sluice valve, non return valve, base plate, pulley with safe guard, vacuum pipe line, LT panel board and writing the MES / SM number with black paint of suitable size of letters complete all as specified and directed.
Supply and replace coupling including rubber / belt of 3 HP to 10 HP motor including necessary arrangements complete all as specified and directed. Note : Quoted rates inclusive all arrangements required for replacement of Coupling
Supply and fix in replacement of HDPE pipe of 65 mm bore suitable for bore well for pressure PN 16 including connection and fitting.
Supply and fix in replacement of HDPE pipe of 50 mm bore suitable for bore well for pressure PN 16 including connection and fitting.
Supply and fix end nipple of HDPE pipe 65mm bore suitable for bore well.
Supply and fix end nipple of HDPE pipe 50mm bore suitable for bore well.
S&F PVC insulated Copper conductor, sheathed, Submersible flat cables of size 4 Sqmm, 3 core, for Submersible Pumps, 1100 Volt
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
BOQ_825081.xls
BOQ • 0.54 MB
T40_8557_Tender.pdf
Tender Documents • 0.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .