Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-Finance BASUDEBPUR BELKHALI HOWRAH PIN 711 322 | HOWRAH | HOWRAH | WEST BENGAL | 711322 | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹7.0 L+₹1.4 L (25.7%)Rejected-Finance G 2 BIDHAN NAGAR P O MIDNAPUR P S KOTWALI DIST PASCHIM MEDINIPUR PIN 721101 | MIDNAPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L2 | Rejected-Finance Higher Bidder | |
| 3 | L3₹7.2 L+₹1.7 L (29.8%)Rejected-Finance 130 OLD 110 BINAY BABU DHAR RD HINDMOTOR HOOGHLY 712233 | HINDMOTOR | HOOGHLY | WEST BENGAL | 712233 | L3 | Rejected-Finance Higher Bidder | |
| 4 | L4₹7.4 L+₹1.9 L (33.7%)Rejected-Finance RAGHUNATHPUR P S JHARGRAM DIST JHARGRAM WEST BENGAL PIN 721507 | JHARGRAM | JHARGRAM | WEST BENGAL | 721507 | L4 | Rejected-Finance Higher Bidder |
| Sl No | Description | Qty | Unit | Computer Gallery L1 | DUTTA ELECTRIC WORKS L4 | SUN ENTERPRISE L3 | M/S JOGMAYA ENTERPRISE L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation ,Testing & Commissioning of Microprocessor controlled Addressable Multisensory detector ( VDS / UL / LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA (Note : Detectors without built-in fault isolator is also acceptable with one independent short circuit fault isolator after every four (04) detector is to be provided without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. Degree of protection as per OEM Standard.
(Approved Make : Cerberus Pro / Essar/ simplex / Edward/ Scotrun/ Securitas/ Apollo / Morley / Eaton /Notifier GST/Ravel/ASES/BOSCH ) | 75 | Nos | 2,100 ₹1,57,500 Lowest | 4,200 ₹3,15,000 | 4,100 ₹3,07,500 | 4,000 ₹3,00,000 |
| 2.00 | Supply, Installation ,Testing & Commissioning of Addressable Manual Call Point ( VDS / UL / LPCB / FM approved ) with in built short circuit fault isolator as per NFPA (Note : MCP without built-in fault isolator is also acceptable with one independent short circuit fault isolator is to be provided without extra cost). Degree of protection as per OEM Standard.
(Approved Make : Cerberus Pro / Essar/ simplex / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton /Notifier GST/Ravel/ASES/BOSCH ) | 4 | Nos | 3,500 ₹14,000 Lowest | 4,300 ₹17,200 | 4,200 ₹16,800 | 4,000 ₹16,000 |
| 3.00 | Supply, Installation, Testing & Commissioning of Addressable Loop Powered / panel power Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator as per NFPA (Note :Hooter without built-in fault isolator is also acceptable with one independent short circuit fault isolator is to be provided without extra cost). ( VDS / UL / LPCB / FM approved ) approved. Degree of protection as per OEM Standard.
(Approved Make : Cerberus Pro / Essar/ simplex / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton /Notifier GST/Ravel/ASES/BOSCH) | 4 | Nos | 4,000 ₹16,000 Lowest | 4,200 ₹16,800 | 4,000 ₹16,000 Lowest | 4,000 ₹16,000 Lowest |
| 4.00 | Supply, Installation, Testing & Commissioning of Microprocessor controlled Addressable Heat detector ( VDS / UL / LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have minimum triggering temperature programmable from 58 deg. C to 68 deg. C., having high level of immunity to electromagnetic influences and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA (Note : Detectors without built-in fault isolator is also acceptable with one independent short circuit fault isolator after every four (04) detector in the loop is to be provided without extra cost) the detectors should have built in response indicator with LED indicator.Degree of protection as per OEM Standard.
(Approved Make : Cerberus Pro / Essar/ simplex / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton /Notifier GST/Ravel/ASES/BOSCH ) | 2 | Nos | 1,000 ₹2,000 Lowest | 3,300 ₹6,600 | 3,200 ₹6,400 | 3,000 ₹6,000 |
| 5.00 | Supply, Installation, Testing & Commissioning of Addressable Control Modules/ Relay Module ( VDS / UL / LPCB / FM approved ) for controlling Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator / External fault isolator with adjustable setting parameter likes(Resistive, Inductive or capacitive) of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signalling maintenance alarm, complete as required.
(Approved Make : Cerberus Pro / Essar/ simplex / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton /Notifier GST/Ravel/ASES/BOSCH ) | 1 | Nos | 1 ₹1 Lowest | 16,000 ₹16,000 | 16,000 ₹16,000 | 15,000 ₹15,000 |
| 6.00 | Supplying, installation, testing and commissioning of LED type Response Indicator having LED lamps including connections etc. Degree of protection as per OEM Standard. (Approved Make : Cerberus Pro / Essar/ simplex / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton /Notifier GST/Ravel/ASES/BOSCH ) | 2 | Nos | 50 ₹100 Lowest | 210 ₹420 | 210 ₹420 | 200 ₹400 |
| 7.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kabel/Polycab/Gloster) through 20mm dia PVC "FR" type Rigid Conduit pipe incl. S & F with necessary arrangement as per GS. (Make: Precision / AKG / Universal / Polycab) on the surface of the wall. | 1,200 | Mtr | 80 ₹96,000 Lowest | 120 ₹1,44,000 | 110 ₹1,32,000 | 100 ₹1,20,000 |
| 8.00 | Supply, Installation, Testing & Commissioning of Microprocessor based addressable OPC complied fully networkable fire alarm control panel ( VDS / UL / LPCB / FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with minimum 320 character alpha - numeric liquid crystal display. The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store minimum 4000 log events in its memory (EPROM).
The panel should have extra loop card slot for future expansion. | 1 | Item | 2,70,000 ₹2,70,000 | 2,27,000 ₹2,27,000 | 2,26,000 ₹2,26,000 | 2,25,000 ₹2,25,000 Lowest |
| 8.01The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analogue output, complete in all respects, in built /externally Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. | |||||||
| 8.02The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485, Modbus/BACnet. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licenced software. Degree of protection as per OEM Standard. (Approved Make : Cerberus Pro / Essar/ simplex / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton /Notifier GST/Ravel/ASES/BOSCH ) | |||||||
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
2 Mar 2026, 1:00 pmClosed
Executive Engineer Paschim Med. Elecl. Div. PWDte.
Office of the Executive Engineer, Paschim Medinipur Electrical Division, P.W.Dte., Midnapore, Paschim Medinipur.
Construction of new Govt. ITI at Sabang Block in the District of Paschim Mednipore. SITC of Fire Detection System.
2026_WBPWD_1008564_1
WBPWD/EE/PMED/NIQ-11/e-Q /2025-2026
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Midnapore, Paschim Medinipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹14,000
Off. of the EE, Pas. Mid. Elec. Divn. PWDte.
23 Jul 2026
17 Feb 2026
5 Mar 2026
17 Feb 2026
2 Mar 2026
20 Feb 2026
19 Feb 2026
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .