Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC 1602 4 13 GOUNDPARI KALKAJI NEW DELHI 19 | 19 | ₹13.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹14.2 L+₹85,795.68 (6.44%)Rejected-Finance 33 C 2ND FLOOR MAIN MARKET OKHLA HEAD JAMIA NAGAR NEW DELHI 25 | NEW DELHI | DELHI | 110001 | ₹14.2 L+₹85,795.68 (6.44%) | L2 | Rejected-Finance L2 |
| 3 | L3₹14.3 L+₹97,209.74 (7.30%)Rejected-Finance 355 125 6 GHAFFAR MANZIL JAMIA NAGAR OKHLA NEW DELHI 25 | 25 | ₹14.3 L+₹97,209.74 (7.30%) | L3 | Rejected-Finance L3 |
| 4 | L4₹18.5 L+₹5.2 L (39.2%)Rejected-Finance 125 B GHAFFAR MANZIL JAMIA NAGAR NEW DELHI 25 | 25 | ₹18.5 L+₹5.2 L (39.2%) | L4 | Rejected-Finance L4 |
Tender Value
₹19.0 L
EMD Value
₹38,047
Closing Date
5 Mar 2026, 5:00 pmClosed
The Registrar, JMI
The Registrar Secretariat, JMI
Maintenance/repair/renovation of Indoor Hall and replacement of running/jogging Track of NMAK Pataudi Sports Complex, Jamia Millia Islamia, Sub-Head (B) Replacement of Conventional Metal Halide fitting into LED ceiling fitting in Indoor Table Tennis
2026_JMI_898078_1
JMI/BD/E-NIT/No.79/2025-26
Open Tender
Civil Works
Percentage
75 days
Maulana Mohammad Ali Jauhar Marg
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
The Registrar, JMI
₹38,047
17 Apr 2026
11 Feb 2026
10 Mar 2026
11 Feb 2026
5 Mar 2026
11 Feb 2026
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
MCCB, MCB & DB’S
Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, "C" Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. as Required.
Single Pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
MV CABLE LAYING
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
Add on Total of DSR 2021 @ 6.33 %
Market Rate Items Electrical
Supplying of 120W LED ceiling Light, Model no (SLE HB 120 watt COMET PRO ) powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -10*C to 50*C , internal surge protection of 5kv & External SPD of 10Kv , Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-08, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 60deg-90deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT - 5700°K (As per ANSI Bin) ,and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 3x1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 2 year OEM warranty. System lumen efficacy ≥110 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. or Eqiuvalent as approved By Engineer Incharge Suyra /Bajaj / Philips /Havells make
Supply at site LED Flood Light 200 watt praze Bajaj model New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and toughned class having bottom opening seperate driver compartment with IP66 Protection, Bajaj/Philips/ Havells /Wipro/ Crompton Make or Eqiuvalent as approved By Engineer Incharge
Supply at site 1.1 KV grade XLPE insulated of size 4 X 16 Sq.mm aluminium armoured.cable Gloster/Havells/Skytone, Make or Eqiuvalent as approved By Engineer Incharge
Installation, testing and commissioning of 120 watt LED Ceiling Light fitting Up to 15 meter height with the Help of portable wheel type Scaffolding including connection with the 18 gauge G.I Wire (1.2 mm) Proper fixing on the existing metal frame etc as required at site as per direction of Engineer in Charge
Installation, testing and commissioning of 200 watt LED Flood Light Upto 15 meter height with the Help of portable wheel type Scaffolding including connection with suitable size fastner Proper fixing on the wall etc as required at site as per direction of Engineer Incharge
stage.html
html • 0.05 MB
techsummary_943972.pdf
BOQ Comparative Chart
xlsx
finsummary_943972.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.20 MB
BOQ_943972.xls
BOQ • 0.31 MB
Agreement.pdf
Additional Documents • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .