Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC SUDARSHANPUR RAIGANJ UTTAR DINAJPUR | RAIGANJ | UTTAR DINAJPUR | WEST BENGAL | 733130 | ₹1.4 Cr Quoted ₹1.8 Cr | L1 | Accepted-AOC On recommendation on SLTC on 25th Meeting |
| 2 | L2₹1.9 CrRejected-Finance | ₹1.9 Cr | L2 | Rejected-Finance On recommendation of SLTC on 25th Meeting |
| 3 | L2₹1.9 CrRejected-Finance RAM NIBAS APPARTMENT 2ND FLOOR THANA ROAD UKILPARA P O RAIGANJ 733134 DIST UTTAR DINAJPUR | RAIGANJ | UTTAR DINAJPUR | WEST BENGAL | 733134 | ₹1.9 Cr | L2 | Rejected-Finance On recommendation of SLTC on 25th Meeting |
| 4 | L3₹1.9 CrRejected-Finance SOUTH BIMAGAR RAIGANJ UTTAR DINAJPUR | RAIGANJ | UTTAR DINAJPUR | WEST BENGAL | ₹1.9 Cr | L3 | Rejected-Finance On recommendation of SLTC on 25th Meeting |
| 5 | Rejected-Technical | - | - | Rejected-Technical On recommendation of TIA |
| Sl No | Description | Qty | Unit | M/s Pinki Construction | Ajit Pramanick | Deep Construction | M/s Lokenath Construction |
|---|---|---|---|---|---|---|---|
| 1.01 | Providing House Service connection from the existing CI/DI/UPVC/HDPE/GI/AC distribution pipeline by supply,fitting & fixing of 10 mm NB Brass Ferrule conforming to lS 2692:1989 with latest amendments on the said pipeline with supply, fitting & flxing of all other accessories like saddle piece of required size to fit the existing distribution pipeline, specials, nut & bolts, rubber sheet, washers etc and supply & laying of 20mm OD HDPE (PE100, PN16) pipe with all necessary specials 1.0 metre below (approx.) the ground connecting the ferrule/flow control valve including cutting trenches in all sorts of soil as well dismantling of any hard crust layer/concrete/masonry etc.(average. 0.3cum per connection) and filling up trenches as per direction of the Engineer-in-charge and upto a point just inside the premises of the household or as directed by ElC. Supply and installation of a 15mm dia. alloy iron Bib Cock (tested to 21 Kg/cm2) above 1.0 Mtr. from ground, an alloy Stop Cock of 15 mm dia. with brass spindle (tested to 21 Kg/cm2) to be fitted in a position as directed by E.l.C. G.l pipe of TATA make (medium duly) of 2 metre length with all necessary specials to continue from the end of the HDPE pipe & upto 1.0 m. above ground within the premises of household including Supply , Fitting and Fixing of Multi Jet Class- B domestic/commercial water metering system (size 15 mm) strictly conform to IS 779-1994 (with all amendements) or MID with AMR compatibility as per specification in the NIeB/NIeT with PE meter box and with NRV valve as specified as per direction of EIC along with periodcial meter reading and submission of reports as mentioned in the scope of work as well as per direction of EIC.
Upto 10m length of HDPE pipe from the distribution pipe line
Casing Pipe of 25mm dia (TATA MAKE GI PIPE MEDIUM DUTY) to be provided by the contractor for crossing of drain if any.
All the damages made on the roads, the compound walls etc. for providing House service connection shall have to be restored by the Plain cement concrete (1:2:4) by the contractor as per direction of EIC. Any damages made on the floor / PCC / tiled / mosaic etc. shall be restored by the Contractor with Plain Cement Concrete (PCC 1:2:4) and neat cement finish as per direction of EIC.
N.B.-GST will be applicable as per Govt.norms | 714 | Nos | 46,41,000 ₹46.4 L | 47,83,800 ₹47.8 L | 46,41,000 ₹46.4 L | 44,98,200 ₹45.0 L |
| 1.02 | Above 10m Upto 20m length of HDPE pipe from the distribution pipe line | 1,450 | Nos | 1,42,10,000 ₹1.4 Cr | 1,43,55,000 ₹1.4 Cr | 1,42,10,000 ₹1.4 Cr | 1,39,20,000 ₹1.4 Cr |
Tender Value
Refer Docs
EMD Value
₹3 L
Closing Date
21 Mar 2025, 5:00 pmClosed
Chairman, Old Malda Municipality
Old Malda Municipality, Old Malda, Malda
House Service Water Connection along with metering
2025_MAD_819008_1
51/C of Chairman/OMM/2024-25 (1st Call), dt-20/02/2025
Open Tender
PLUMBING WORKS ORG
365 days
Old Malda Municipality
As per NIeT
6 documents required · 6 mandatory
₹0
₹3 L
11 Jun 2026
28 Feb 2025
25 Mar 2025
28 Feb 2025
21 Mar 2025
28 Feb 2025
Providing House Service connection from the existing CI/DI/UPVC/HDPE/GI/AC distribution pipeline by supply,fitting & fixing of 10 mm NB Brass Ferrule conforming to lS 2692:1989 with latest amendments on the said pipeline with supply, fitting & flxing of all other accessories like saddle piece of required size to fit the existing distribution pipeline, specials, nut & bolts, rubber sheet, washers etc and supply & laying of 20mm OD HDPE (PE100, PN16) pipe with all necessary specials 1.0 metre below (approx.) the ground connecting the ferrule/flow control valve including cutting trenches in all sorts of soil as well dismantling of any hard crust layer/concrete/masonry etc.(average. 0.3cum per connection) and filling up trenches as per direction of the Engineer-in-charge and upto a point just inside the premises of the household or as directed by ElC. Supply and installation of a 15mm dia. alloy iron Bib Cock (tested to 21 Kg/cm2) above 1.0 Mtr. from ground, an alloy Stop Cock of 15 mm dia. with brass spindle (tested to 21 Kg/cm2) to be fitted in a position as directed by E.l.C. G.l pipe of TATA make (medium duly) of 2 metre length with all necessary specials to continue from the end of the HDPE pipe & upto 1.0 m. above ground within the premises of household including Supply , Fitting and Fixing of Multi Jet Class- B domestic/commercial water metering system (size 15 mm) strictly conform to IS 779-1994 (with all amendements) or MID with AMR compatibility as per specification in the NIeB/NIeT with PE meter box and with NRV valve as specified as per direction of EIC along with periodcial meter reading and submission of reports as mentioned in the scope of work as well as per direction of EIC. Upto 10m length of HDPE pipe from the distribution pipe line Casing Pipe of 25mm dia (TATA MAKE GI PIPE MEDIUM DUTY) to be provided by the contractor for crossing of drain if any. All the damages made on the roads, the compound walls etc. for providing House service connection shall have to be restored by the Plain cement concrete (1:2:4) by the contractor as per direction of EIC. Any damages made on the floor / PCC / tiled / mosaic etc. shall be restored by the Contractor with Plain Cement Concrete (PCC 1:2:4) and neat cement finish as per direction of EIC. N.B.-GST will be applicable as per Govt.norms
Above 10m Upto 20m length of HDPE pipe from the distribution pipe line
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid