Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹24.9 L+₹1.5 L (6.37%)Rejected-AOC | L2 | Rejected-AOC 2ND LOWEST | |
| 3 | L3₹25.8 L+₹2.4 L (10.1%)Rejected-AOC | L3 | Rejected-AOC 3RD LOWEST | |
| 4 | Rejected-Technical 142 1 ERUVADA JUNCTION ERUVADA VILLAGE SABBAVARAM MANDALAM SABBAVARAM VISAKHAPATNAM ANDHRA PRADESH 531035 | VISAKHAPATANAM | ANDHRA PRADESH | 531035 | - | Rejected-Technical REJECT |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
10 Oct 2020, 6:00 pmClosed
R S SHUKLA EE
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
COMPREHENSIVE MAINTENANCE OF STP OF 600 KLD AND 800 KLD CAPACITY AT GMS
2020_MES_360979_2
8000/22/20-21/0921 /E8
Open Tender
Civil Works
Item Rate
270 days
GOPALPUR MILITARY STATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹44,000
Yes
17 Nov 2020
18 Sept 2020
12 Oct 2020
18 Sept 2020
10 Oct 2020
28 Sept 2020
Amount
M&L Preparation of old surface by scraping and smoothing the surface with water emery paper and painting with approved colour of synthetic enemelled paint of two coat over a coat of primer red oxide and writing letters/numbers(SM/MES Nos. and DATE OF CLEANING ) of sewage treatment plants of capacities 600/800 CUM/Day and cleaning the surrounding area up to three metre out side area of the plant by cutting grasses and surface dressing for Moving Bed Bio Reactor 1 & 2etc complete all as specified and directed.
All as per item No 01 above but dual Media filter.
All as per item No 01 above but Activated carbon filter.
All as per item No 01 above but Exposed water pipe lines.
All as per item No 01 above but filter feed pump.
All as per item No 01 above but filter backwash pump.
All as per item No 01 above but distribution panel board.
All as per item No 01 above but Tube settler tank.
All as per item No 01 above but Air Blower with compressor 1 & 2.
Cleaning of sludge drying beds removing all sludges and de-scaling vegetation on the inside and outside of sludge bed and white washing (Two Coat) including Cleaning the surroundings area of the sludge drying beds to a distance of 3 mtrs circumstance including cutting of grass digging out roots, filling holes and levelling around and removing waste materials to a distance not exceeding 50 Mtrs complete all as specified and directed.
All as per item No 10 but Equilization Tank and air grid.
All as per item No 10 but Bar screen and pit
All as per item No 10 but Oil and grease trap
All as per item No 10 but Tube settler tank
All as per item No 10 but Clear water tank
All as per item No 10 but chlorine contact tank.
Supply and replacement of MCB 32 Amp 3 pole AC, 415 volts, MC-1,10 KA complete all as specified and directed Make –SCHNEIDER/SEIMENS CG/HAVELL’S/ L&T/C&S.
Supply and replacement of MCB 10Amp SP AC, 240 volts,MC-2, 10 KA complete all as specified and directed Make –SCHNEIDER/SEIMENS CG/HAVELL’S/ L&T/C&S. .
S&F butterfly valve 100mm dia complete all as specified and directed.
S and F in replacement galvanised iron strip 32 x 6 mm complete all as specified and directed
Supply and use stable bleaching powder ISI marked in 25 Kg bag complete all as specified and directed Make- Sree Rayalaseema Hi-strength hypo Ltd.
S&F liquid chlorine of 8 to 10% chlorine complete all as specified and directed (sodium hypochloride) Make- Cemtex speciality Ltd/Sun chemicals/ Sree Rayalaseema Hi-strength hypo Ltd.
Supply and fixing Poly aluminium chloride liquid 100% concentrate complete all as specified and directed.Make- Sree Rayalaseema Hi-strength hypo Ltd.
Supply and fixing Poly electrolite liquid 100% concentrate complete all as specified and directed.Make- Sree Rayalaseema Hi-strength hypo Ltd.
Supply and fixing Filter media for MBBR complete all as specified and directed. Make- Biotech India Ltd/ Aquatech International/Weldone water system .
Supply and fixing Carbon for activated carbon filter and dual media filter complete all as specified and directed. Make- Weldone water system.
Labour and T&P surface dressing of grass vegitation around the various STP installation.
M&L for replacement of unserviceable spindle and check nut of stainless steel, packing materials from the exicting valve incl sluice valve, taking out and reassembling properly complete all as specified and directed for the 100 mm bore of pipes.
Supply anf fix lubiricant oil (320 Gde) at every two months incl draining out old oil from engine of blowers of any capacity and FAB feed pumps of any capacity and cleaning oil chamber complete all as specified and directed Make- Servo/castrol/Gulf
Dismantling the power supply of electric motor any type including dismantling from pump and taking to workshop with necessary transportation and opening the complete motor and rewinding the rotor with super enameled copper wire as per the existing gauge with necessary insulation, sticks and varnishing, including replacement of shaft bearing 02 Nos complete of capacity 20 to 30 HP complete all as specified and directed.
All as per item No.30 above but of capacity 5 to 7.5 HP electric motor any type.
All as per item No.30 above but of capacity 10 to 15HP electric motor any type.
All as per item No.30 above but 1 to 3 HP electric motor any type.
Dismantling complete Centrifugal /Mono Block pump set of any type and overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers. Rematlling and balancing of shaft, replacement of gunmetal bush bearing and gland packing of pump set. and refitting the same after the repair/replacement duly all as specified and tested for smooth functioning of capacity 20 to 30 HP
All as per item No 34 above but capacity 10 to 15 HP
All as per item No-34 above but capacity 5 to 7.5 HP
All as per item No- 34 above but capacity 1 to 3 HP
Supply and replacement Contactor, 3poles with AC3 coil of 18 amps Break capacitor ,110 VAC Coil complete all as specified and directed. Make –SCHNEIDER/SEIMENS CG/HAVELL’S/ L&T/C&S.
Supply and replacement Contactor, 3poles with AC3 coil of 9 amps Break capacitor, 110 VAC Coil complete all as specified and directed Make –SCHNEIDER/SEIMENS CG/HAVELL’S/ L&T/C&S.
Supply and replacement Connector, 2.5 SQ mm & 110 Q 800 VAC Coil complete all as specified and directed Make –ELMEX or equivalent
Supply and replacement stop button SB, 230 Volt, 6 A, NC, contact complete all as specified and directed Make –RAJ/TECHNIC/GILARD
Supply and replacement auto /Mannual SB-1, 230 Volt, 6 A, NC, contact complete all as specified and directed Make –RAJ/TECHNIC/GILARD
PPR Pipe 3 layer SDR 7.4 & SDR 11 UV stabilized and antimicrobical welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded PPR Fittings fixed complete to walls ,celling or in floors etc 50 mm outer dia Make- SFMC or equivalent as approved by E-in-Cs branch.
PPR Pipe 3 layer SDR 7.4 & SDR 11 UV stabilized and antimicrobical welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded PPR Fittings fixed complete to walls ,celling or in floors etc 110 mm outer dia Make- SFMC or equivalent as approved by E-in-Cs branch.
PPR Pipe 3 layer SDR 7.4 & SDR 11 UV stabilized and antimicrobical welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded PPR Fittings fixed complete to walls ,celling or in floors etc 63 mm outer dia Make- SFMC or equivalent as approved by E-in-Cs branch.
PPR Pipe 3 layer SDR 7.4 & SDR 11 UV stabilized and antimicrobical welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded PPR Fittings fixed complete to walls ,celling or in floors etc 40 mm outer dia Make- SFMC or equivalent as approved by E-in-Cs branch.
PPR Pipe 3 layer SDR 7.4 & SDR 11 UV stabilized and antimicrobical welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded PPR Fittings fixed complete to walls ,celling or in floors etc 32 mm outer dia Make- SFMC or equivalent as approved by E-in-Cs branch.
S&F PPR gate valve (brass insert) 110mm outer dia complete all as specified and direcdted. Make- SFMC or equivalent as approved by E-in-Cs branch.
S&F PPR gate valve (brass insert) 63mm outer dia complete all as specified and direcdted. Make- SFMC or equivalent as approved by E-in-Cs branch.
S&F PPR gate valve (brass insert) 50mm outer dia complete all as specified and direcdted. Make- SFMC or equivalent as approved by E-in-Cs branch.
S&F PPR gate valve (brass insert) 40mm outer dia complete all as specified and direcdted. Make- SFMC or equivalent as approved by E-in-Cs branch.
S&F PPR gate valve (brass insert) 32mm outer dia complete all as specified and direcdted. Make- SFMC or equivalent as approved by E-in-Cs branch.
S&F single phase prevation for starter complete all as specified and directed.
M/S. KISHAN ENGINEERING
M/s Ats Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .