Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹10.2 L+₹3,600 (0.36%)Rejected-Finance | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹10.4 L+₹24,174 (2.39%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹10.4 L+₹26,366 (2.60%)Rejected-Finance | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | L5₹10.7 L+₹53,894 (5.32%)Rejected-Finance | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹9.3 L
EMD Value
₹19,000
Closing Date
13 Sept 2024, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
REPAIR / MAINT / IMPV OF BUILDING SERVICE CONNECTION, INTERNAL LIGHTING SYSTEM, LED LIGHTING AND LIGHTNING PROTECTION SYSTEM IN VARIOUS ACCN AT JALAPAHAR UNDER AGE(I) DARJEELING
2024_MES_667399_1
CWE/136-WE/30 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Darjeeling
Class E Category a(i), b(i)
8 documents required · 8 mandatory
₹500
AGE (I) Darjeeling
₹19,000
1 Jan 2025
23 Jul 2024
14 Sept 2024
23 Jul 2024
13 Sept 2024
7 Aug 2024
23 Jul 2024 - 30 Jul 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
Taking down DB's including MCB's etc., complete all as specified and directed.
Taking down carefully unserviceable sub main wiring of any size/core/type including making good the disturbed surfaces, complete all as specified and directed.
M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor cable 1.5 Sq mm size in and including PVC casing caping double lock type of size 25X16mm including one No. 1.5 Sq mm single core PVC insulated copper cable for continuous earth wire connected to earth dolly for one light /Bell point controlled by one 5 Amp switch one way and sharing of wire in casing capping shall be as per IS specification including making good disturbed surface of walls & floors etc., complete all as specified and directed.
M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor cable 1.5 Sq mm size in and including PVC Conduit medium grade ISI marked of required size min 20mm including one No. 1.5 Sq mm single core PVC insulated copper cable for continuous earth wire connected to earth dolly for one light /Bell point controlled by one 5 Amp switch one way and sharing of wire inconduit shall be as per IS specification including making good disturbed surface of walls & floors etc., complete all as specified and directed.
M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor cable 1.5 Sq mm size in and including PVC casing caping double lock typeof 20/25mm width including one No. 1.5 Sq mm single core PVC insulated copper cable for continuous earth wire connected to earth dolly for one 3/5 Pin, 5 Amp socket outlet on the independent board and sharing of wire in casing capping shall be as per IS specification including making good disturbed surface of walls & floors etc., complete all as specified and directed.
M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor cable 1.5 Sq mm size in and including one No. 1.5 Sq mm single core PVC insulated copper cable for continuous earth wire connected to earth dolly for one 3/5 Pin, 5 Amp socket outlet with other switches on the Same board & and making good disturbed surface of walls & floors etc., complete all as specified and directed.
M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor cable 2.5 Sq mm size in and including PVC casing caping double lock type of width minimum 20mm including one No. 2.5 Sq mm single core PVC insulated copper cable for continuous earth wire connected to earth dolly for one 6 Pin, 15 Amp socket out let on the independent board and sharing of wire in casing capping shall be as per IS specification for wires of more than one power point passing through the casing capping including making good disturbed surface of walls & floors etc., complete all as specified and directed.
S&F of switch piano, flush type single pole, one way, 5 Amps / 6 Amp, 240 Volts, all as specified and directed.
M&L for bell push, flush type, 5/6 amp, 240 Volts, all as specified and directed.
M&L for Buzzer, Ding Dong AC. 230 volts, single pole, all as specified and directed.
M&L for ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, three terminal, 240 Volts, all as specified and directed.
M&L for socket outlet 2 in 1, 3 pin, 5 Amps / 6 Amps flush type, 240 Volts, all as specified and directed.
M&L for switch socket combination 2 in 1, 5 Amps / 6 Amps flush type, 240 Volts, all as specified and directed.
M&L for switch socket combination 3 pin 6 Amp / 16 Amp, 5 in 1, flush type, 240 Volts, all as specified and directed.
S&F in repair wall mounted LED Tube light fitting 20 Watts (min) surface mounting general purpose LED Batterns in Extuted Aluminium housing including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site on 02 Nos new round blocks including, complete all as specified and directed.
S&F in repair wall mounted LED Tube light fitting 10 Watts (min) surface mounting general purpose LED Batterns in Extuted Aluminium housing including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site on 02 Nos new round blocks including, complete all as specified and directed.
S&F in repair new generation , energy saving, aesthetically designed, recessed mounted down light Adjustable spot light 8 Watt (min) pressure die-cast aluminium heat sink & high efficiency long life LED mounted on base with high efficacy, complete all as specified and directed.
S&F in repair in repair LED panel Square (2'X2') Plano Taps recess mounted luminaires which suites various ceiling types with tapered housing makes in most flexible to install in low clerance ceiling .including making connections with 2 core flexible copper wire 0.50 Sq mm, complete all as specified and directed.
S&F in repair LED panel Square (1'X1') recess mounted light fitting including making connections with 2 core flexible copper wire 0.50 Sq mm, complete all as specified and directed.
S&F in repair sleek LED Bulk head fitting 10 watt, IP-65 suitable for outdoor and indoor areas in perfect synchronization with functionality and aesthetics complete all as specified and directed. Make: Havells/Crompton/Bajaj/Surya/Panasonic
S&F in repair LED Building Security light fitting 30 watt energy saving environmental friendly long life LED Street light made up pressure die cast aluminium housing with high efficiency LEDs complete with fixing arrangements, all as specified and directed.
M&L for sub main wiring with two single core 6.0 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 4.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly, complete all as specified and directed. Not : Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
All as per Ser item no. 23.00 but with 2 x 4 Sqmm for phase & neutral and 1 x 2.5 Sqmm for earth continuity single core copper conductor.
All as per Ser item no. 23.00 but with 2 x 2.5Sqmm for phase & neutral and 1 x 2.5 Sqmm for earth continuity single core copper conductor.
S&F in repair of Sheet Metal Enclouser Double door DB 415 volts, 4 way with 200 Amps rated bus bar Three pole & neutral (TPN) fixing on suitable rectanguler block, duly connected incoming and outgoing wires in DB and good finish to the old disturbed surface, complete all as specified and direceted.
S&F in repair of Sheet Metal Enclouser Double door DB 240 volts, 12 way with 200 Amps rated bus bar Single pole & neutral fixing on suitable rectanguler block, duly connected incoming and outgoing wires in DB and good finish to the old disturbed surface, complete all as specified and direceted.
S&F in repair of Sheet Metal Enclouser Double door DB 240 volts, 8 way with 200 Amps rated bus bar Single pole & neutral including fixing on suitable rectanguler block, duly connected incoming and outgoing wires in DB and good finish to the old disturbed surface, complete all as specified and direceted.
S&F in repair of Sheet Metal Enclouser Double door DB 240 volts, 4 way with 200 Amps rated bus bar Single pole & neutral including fixing on suitable rectanguler block, duly connected incoming and outgoing wires in DB and good finish to the old disturbed surface, complete all as specified and direceted.
S&F in repair MCB Single Pole Neutral C Curve 230 volts of capacity 32 Amp 10 KA, complete all and specified and directed.
S&F in repair MCB Single Pole of capacity 6Amp to 32Amp, C-curve 240 volts 10KA, complete all and specified and directed.
S&F in repair MCB, 63Amp, TPN breaking capacity 10KA, 415 Volt, 50 Hz, complete all and specified and directed.
Supply and Fix in repairs MCCB Metal enclosures, MCCB FP 100 Amps 415 Volts 16KA fixing in Metal enclosure, in wall mounted type complete with all accessories, including taking down of old Unsv main switch and reconnecting the cables with proper, complete all and specified and directed.
S&F in repair LED Gate light fitting 25 watt IP 65 LED Post top family energy saving environmental friendly long life spun aluminium landscape luminaire with high power LEDs as light source, complete all and specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron or steel earth lead wire 4mm dia size by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 3 of SSR part I including necessary excavation and earth work GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated including testing, complete all and specified and directed.
Taking down old existing air termination rod from building roof and keeping in safe custody for re-use / taken as such to credit, complete all and specified and directed.
Taking down old existing aluminum strip of size 25 x 3.15 mm and keeping in safe custody for re-use / taken as sch of credit, complete all and specified and directed.
Taking down old existing GI strip of size 32 x 6 mm and keeping in safe custody for re-use / taken as sch of credit, complete all and specified and directed.
Taking down old existing earth test point from building/walls and keeping in safe custody for re-use / taken as such to credit, complete all and specified and directed.
M&L for air termination, single pointed aluminium rod 12mm dia and 300mm long, complete all and specified and directed.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all and specified and directed.
M&L for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all and specified and directed.
M&L for galvanised iron strip 32 x 6mm buried in ground, complete all and specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x60 cm x6.0 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron strip 32x6 mm as earthing lead by mean of bolts , nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I of 2009 connected to earthing test point all as specified complete with excavation and earth work PCC pit with 50 mm thick RCC cover (grade M-15) having suitable handle (10 mm MS Rod) 20 mm dia GI medium grade ISI marked watering pipe with GI funnel with wire mesh 40 mm bore GI Pipe ISI marked (medium grade ) for protection of earth lead conductor all as directed and testing on completion.
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor of size 6 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor of size 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
GEETA CONSTRUCTION (BID ID -3088973)
BHASKAR PRADHAN (BID ID -3086036)
TSHERING WANGYAL BHUTIA (BID ID -3088846)
JALAPAHAR HARDWARE (BID ID -3088330)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .