Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC | ₹4.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹4.0 LRejected-AOC | ₹4.0 L | L2 | Rejected-AOC L2 |
| 3 | L3₹4.1 LRejected-AOC 889 RAJA RAMMOHAN ROY ROAD KOLKATA 700041 | KOLKATA | WEST BENGAL | 700041 | ₹4.1 L | L3 | Rejected-AOC L3 |
Tender Value
₹4.0 L
EMD Value
₹8,000
Closing Date
11 Dec 2025, 2:00 pmClosed
Executive Engineer/Z-III
LIGHTING DEPARTMENT Kolkata Municipal Corporation 28A, K.N. SEN ROAD Kolkata-700 042
RENOVATION OF DECORATIVE LIGHTING SYSTEM AT SADANANDA ROAD, RASHBEHARI AVENUE AND OTHERS IN WARD NO-83.
2025_KMC_950743_1
KMC/LTG/Z-III/2025-2026/547
Open Tender
ELECTRICAL WORKS M/R
30 days
SADANANDA ROAD, RASHBEHARI AVENUE
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹8,000
22 Mar 2026
21 Nov 2025
11 Dec 2025
21 Nov 2025
11 Dec 2025
21 Nov 2025
SUPPLY & DELIVERY OF LED POST TOP FITTING 40 WATT
Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 10 1/3.55 4
Laying through Underground Trech.(a)Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 54. 40mm heavy gauge Polythene Pipe
SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe.
Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe,, Pole CAP etc. Erection of minipole of height 3.25 M to 5.0 M in C.C. foundation 0.46 m x 0.46 m x 0.9 m depth of 1:3:6 cement concrete with hard jhama metal/stone chips including muffing of 0.3m x0.3m x 0.3m painting the pole with 2 coats of aluminium paint over a coat red oxide.
SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 14. Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface,loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km
Sub Total
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.01 MB
BOQ_2270451.xls
BOQ • 0.29 MB
FORM.pdf
Tender Documents • 0.54 MB
Download all tender documents and submit your bid