| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC OK | |
| 2 | L2₹44.6 L+₹2.7 L (6.38%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹48.4 L+₹6.4 L (15.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹49.4 L+₹7.5 L (17.9%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹49.7 L+₹7.8 L (18.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
30 Jul 2020, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT-10
GE E/M BASE HOSPITAL DELHI CANTT-110010
REPAIR/ REPLACEMENT OF DISINFECTION SYSTEMS AT COVID-19 ICUS ISOLATION WARDS ICU EXTN WARDS COVID -19 OT NO 07 AND 08 AND OTHER MISC CONNECTED WORKS AT BASE HOSPITAL UNDER GE E/M BASE HOSPITAL DELHI
2020_MES_357521_1
GE/BH-31/2020-21
Open Tender
Electrical and Maintenance Works
Works
60 days
GE E/M BASE HOSPITAL DELHI CANTT-10
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE E/M BASE HOSPITAL DELHI CANTT-10
₹99,800
Yes
31 Oct 2020
1 Jul 2020
1 Aug 2020
1 Jul 2020
30 Jul 2020
16 Jul 2020
Amount
Supply, installation, commissioning & testing in replacement anti bacterial and virus removing equipment in central air conditioning facility to eliminate sick building syndrome risk by reducing odor, air pollutions, VOCs (chemical odors), molds, bacteria, and virus, for the following size AHUs working on 24 VAC, 0.7 Amps, 17 Watts) complete all as specified and directed. (Model:- Guardian Air QR+ by RGF designed of Zeco or equivalent model of M/S Oxycure Pvt Ltd. / Desnet Engineers Pvt. Ltd.) : -
AHU 10500 CFM (VIP)
AHU 32000 CFM (ICU No. 2) NOTE FOR ITEM NO 1.02: As per OEM design/ requirement, 02 Nos Anti Bacteria and Virus removing devices shall be installed in Each AHU. Accordingly mode of measurement shall be 'Per Anti Bacteria and Virus removing equipments i.e 02 Units shall be measured and paid for Each AHU.
AHU 7500 CFM (C-6)
AHU 7500 CFM (NICU)
AHU 14000 CFM (Pediatrics)
Supply, installation, commissioning & testing in replacement air purification system with replacement of normal plastic filters the system shall built with PHI cells, HEPA filters, variable frequency controller and with following controlling and monitoring equipments, with necessary iron frame suitable for hanging the device on wall, Fabricated as per OEM Recommendation along with one primer coat, one under coat and one finishing coat of Synthetic enamel paint complete all as specified and as directed: - (a) Multi stage air purification unit (b) Air flow: 500 smh (c) Pre filter, G4 grade, EN779:2012 certified (d) Chemical filter for gaseous pollutants (e) Final filter, F9 grade, EN779:2012 certified (f) Variable speed controller (g) Pressure differential sensor (h) In built EC motor (i) Energy consumption: 65 Watts (j) Installation type: Ceiling, Floor, Wall (k) Weight: Less than 35 Kgs (l) 920mm x 420mm x 300mm (m) PHI cells, HEPA filters, other customization (Model:- Guardian Air QR+ by RGF designed of Zeco or equivalent model of M/S Oxycure Pvt Ltd. / Desnet Engineers Pvt. Ltd.)
M & L in replacement under deck insulation for metal roof with bonded fiber glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminum foil backed up by scrim and Kraft paper (FSK), facing with 50 mm projection for overlap and butting comprising of the following complete all as specified and as directed:- (insulating material shall conform to BS - 476, Part 4,5, 6 & 7):- “(a) Supply and fix 6 mm dia M S rods between purlins suitably for supporting the required thickness of insulation material beneath the metal roof.“(b) Supply and fix 22 SWG GI/Aluminium wires supports for insulation.“(c) Supply and fix chicken wire mesh 12.5 mm x 22 SWG of hexagonal construction below the insulation for supporting the same.
M & L for DOP SITE TESTING OF HEPA FILTERS at OT in following stages complete all as specified and as directed:- (a) Testing will be done with the help of photometer and smoke generator. (b) Room validation will be done with particle counter. (c) Velocity of outlet of HEPA filters shall be done with velocity meter. (d) Checking of class with particle counter. (e) Checking the flow through HEPA Filters with anemometer (f) Integrity test for the installation of HEPA Filters with PAO. With Aerosol Photometer (g) Checking of HEPA Filter pressure drop (h) Checking of light intensity test (lux level) (i) Checking of the equipment sound level test Note: (i) Compressed air and all other materials for testing shall be arranged by the contractor. (ii) Contractor shall visit the site before quoting the above items and quote accordingly.
S&F in repair 50mm thick box type Pre-Filter (EU-4) Synthetic media type flange type (non woven type) efficiency - 90% down to 10 micron with complete all fitting for AHU and 50 mm wg static pressure with rod support fabrication with GI/Aluminium frame, suitable for AHU of make Fedders Lloyd complete all as specified and as directed. MAKE of filter:- Athlete/ AAF/ Fredenberg
S&F in repair thick box type fine -Filter (EU-5) Synthetic media type flange type (non woven type) efficiency - 95% down to 5 micron with complete all fitting for 3500 CFM AHU of size 610mmX610mmX305 mm with rod support fabrication with GI/ Aluminium frame suitable for AHU of make Fedders Lloyd complete all as specified and as directed. Make of filter:- AAF/ Fredenberg/ Camfil
S&F in repair thick box type fine -Filter (EU-5) Synthetic media type flange type (non woven type) efficiency - 95% down to 5 micron with complete all fitting for 3000 CFM AHU of size 610mmX610mmX305 mm with rod support fabrication with GI/ Aluminium frame suitable for AHU of make Fedders Lloyd complete all as specified and as directed. Make of filter:- AAF/ Fredenberg/ Camfil
S&F in repair thick box type fine -Filter (EU-5) Synthetic media type flange type (non woven type) efficiency - 95% down to 5 micron with complete all fitting for 3000 CFM AHU of size 610mmX305mmX305 mm with rod support fabrication with GI/ Aluminium frame suitable for AHU of make Fedders Lloyd complete all as specified and as directed. Make of filter:- AAF/ Fredenberg/ Camfil
S&F in repair thick box type fine -Filter (EU-5) with base frame and fixing accessories as required Synthetic media type flange type (non woven type ) efficiency - 95% down to 5 micron with complete all fitting for 12600 CFM AHU of size 610mmX610mmX50 mm with rod support fabrication with GI/ Aluminium frame suitable for AHU of make Fedders Lloyd complete all as specified and as directed. Make of filter:- AAF/ Fredenberg/ Camfil
S&F in repair thick box type fine -Filter (EU-5) with base frame and fixing accessories as required Synthetic media type flange type (non woven type ) efficiency - 95% down to 5 micron with complete all fitting for 12600 CFM AHU of size 305mmX610mmX50 mm with rod support fabrication with GI/ Aluminium frame suitable for AHU of make Fedders Lloyd complete all as specified and as directed. Make of filter:- AAF/ Fredenberg/ Camfil
S&F in repair hepa Filter (EU-13) minioleat box type 0.3 micron hepa filter, efficiency 99.997% at .03 Micron particle size with aluminium anodised casing of size as following complete all as specified and as directed. Make of filter:- AAF/ Fredenberg/ Camfil (i) 810mmx610mmx69mm - 04 Nos. (ii) 610mmx305mmx69mm - 04 Nos. (iii) 610mmx375mmx69mm - 02 Nos.
Taking down existing 40 TR compressor of ICU AC plant along with motor of 50 HP from base plate foundation, dismantling of rubber coupling and necessary nuts and bolts, taking down of control wiring and power wiring, expansion valve, solenoid valve and all connected accessories as required, dismantling the cracked RCC foundation and foundation bolts and M & L for refixing of base plate with provision of new RCC foundation screws and refixing the compressor and motor with rubber coupling with proper alignment and refixing of control wiring and power wiring, expansion valve, solenoid valve and all connected accessories complete as required at site, as specified and as directed.
Saini Enterprises
DP Traders
J.P. Enterprises
ABK Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .