| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC S NO 50 8 MAMTA SOCIETY VADGAONSHERI BEHIND AYYAPPA TEMPLE PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹25.0 L+₹1.9 L (8.27%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹28.6 L+₹5.4 L (23.5%)Rejected-Finance NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹29.3 L+₹6.2 L (26.7%)Rejected-Finance | L4 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹21.9 L
EMD Value
₹44,000
Closing Date
17 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
SPL REPAIR TO EXTERNAL ELECTRIC SUPPLY AT LEBONG UNDER AGE(I) DARJEELING
2022_MES_539604_3
CWE/136-WE/21 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Darjeeling
Class E, Category b(ii)
8 documents required · 8 mandatory
₹500
AGE (I) Darjeeling
₹44,000
21 Jan 2023
26 Oct 2022
18 Nov 2022
26 Oct 2022
17 Nov 2022
3 Nov 2022
26 Oct 2022 - 31 Oct 2022
Amount
Dismantling of unserviceable ACSR or AAC conductor of any type and size from over head electric line carefully with out making any damage to the other existing lines and removing from site complete all as specified and as directed.
Dismantling earth wire or copper conductor, service feeder or distributor span, complete all as specified and as directed.
Dismantling cross-arms of M.S. channel or angle sections, bracings etc. complete and setting aside for re-use with in 50m, complete all as specified and as directed.
Dismantling of insulators any type any size from existing poles, complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of underground cables etc. or for shafts, wells, cesspits, manholes, pier holes, under groung cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m and not exceeding 3.0 m in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 sq.m on plan and not exceeding 3 m in depth and getting out in soft/loose soil all as specified and directed. Note: Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Returning filling in soft / loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
M&L for sand cushioning to under ground cable in layers of 23cm thick (8 cm before laying the cable and 15 cm thick after laying the cable) in trenches, complete all as specified and as directed. Note :-Puned layers of 18 cm thick sand shall measured only.
Supply and laying of old size Burnt clay fly ash building bricks designation 75(Kg/cm2) laid flat equal to width of bricks, perpendicular to under ground (UG) cable over the dry sand cushioning, for cable protection, complete all as specified and directed.
Dismantling/Taking out old unserviceable service connection cables / under groung cables, of any grade / type of size as below from pole/ wall/ cable duct/ under ground trench etc, all as specified and as directed.
Supply and laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable of cross-sectional area 120 Sq.mm, 3.5 Core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed. (Note:- Excavation & earth work and pipe / sand / bricks for cable protection shall be measured and paid for separately under appropriate item of this schedule)
Supply and laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable of cross-sectional area 95 Sq.mm, 3.5 Core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed. (Note:- Excavation & earth work and pipe / sand / bricks for cable protection shall be measured and paid for separately under appropriate item of this schedule)
Supply and laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable of cross-sectional area 25 Sq.mm, 4 Core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed. (Note:- Excavation & earth work and pipe / sand / bricks for cable protection shall be measured and paid for separately under appropriate item of this schedule)
M&L for 50mm dia steel tubes (light grade) galvanised with all fittings, laid in trenches/wall/pole/road crossing for protection of underground cable, all as specified and as directed.
M&L for 40mm dia steel tubes (light grade) galvanised with all fittings, laid in trenches/wall/pole/road crossing for protection of underground cable all as specified and directed.
M&L for cutting existing road/ hard standing not exc 20x30 cm in wide and depth getting out excavated material for laying cable/ GI tube, returning filling and well ramming watering finish suraface 10 cm from top using plain cement concrete (1:3:6) type C-2; including removal of surplase soil all as specified and as directed.
Supply install commissioning and testing in replacement of floor mounted Outdoor cubical type LT Feeder Pillar Box (CPRI approved) of size 1500 X 1300 X 500 mm fabricated out of 3.15 mm thick CRCA Sheet and angle iron 60 X 60 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back centre openable double door with locking arrangement cable entry and exit from bottom with cable glands and gaskets, Digital VAF + PF Meter- 01 Set, including LED indicating lamps- 03 Nos, internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's and Bus-bar. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator, connected with Aluminium lugs, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation all as specified and as directed, comprising of the following :- Notes: 1. Internal Wiring with single core copper conductor cable/ PVC Insulated Strip of suitable size incoming busbar and busbar to out going MCCB/MCB - 1 Job. 2. Fine wiring ith single core copper conductor cable for instruments/indicating lamps - 1 Job. (Make of LT Feeder Pillar Box: As per Tender Documents) Cont/-
INCOMING (a) Bus bar chamber comprising 04 Nos tin plated copper strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 400 Amps with colour coding for RYB & N - 01 Set (b) MCCB 200 Amp , 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25KA)Ics=100% of Icu, with spreader terminal of both ends-01 No. (Make Legrand Cat part No-4202 18 or equivalent in L&T/ Schinder/ Siemens/ ABB/ C&S/ HPL/ Indo Asian(OPTIPRO)/ GE/ Hensel) OUTGOING (c) MCCB 63 Amp , 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side-05 No. (Make Legrand Cat part No-4200 13 or equivalent in L&T/ Schinder/ Siemens/ ABB/ C&S/ HPL/ Indo Asian(OPTIPRO)/ GE/ Hensel) (d) MCCB 100 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 16KA)Ics=100% of Icu, with spreader terminal of both ends-02 No. (Make Legrand Cat part No-4200 15 or equivalent in L&T/ Schinder/ Siemens/ ABB/ C&S/ HPL/ Indo Asian(OPTIPRO)/ GE/ Hensel) (Note: Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication).
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint, complete all as specified and as directed.
S&F of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00 metres long) as per IS: 2713-(Part I to 3)-1980 including one coat of red oxide primer and two of aluminium paint, all as specified and as directed.
S&F of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.00 metres long) as per IS: 2713-(Part I to 3)-1980 including one coat of red oxide primer and two of aluminium paint, all as specified and as directed.
Supply, installation, connecting electrically and commissioning switchs air break, gang operated, tripple pole mounted on polymer insulators 15 numbers and steel frame with operating mechanism in worked from ground level, drop out fuse, for current rating upto 400 amps and working voltage 11000 volts including taking down existing unserviseable switchs air break, gang operated after dismantling all as required at site, complete all as specified and directed.
S&F of lightening arrester non liner type confirming to IS: 3070-(Part I)-1985 complete with all fittings, transmission class discharge capacity 10 KA suitable for 11000 Volts including making connections with over head line with ACSR conductor complete on poles, all as specified and as directed.
M&L for cement concrete (1:2:4), type B-2 (using 40 mm graded stone aggregate) for foundation of pole, stay, plinth/ staging of transformer, mass concrete etc including necessary form work and fair finishing without using extra cement, all as specified and as directed.
M&L for cement concrete(1:3:6), type C-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete, all as specified and as directed.
M&L for brickwork with old size burnt fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), all as specified and as directed.
M&L for stay assembly using 20 mm diameter of stay rod complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately), all as specified and as directed.
M&L for loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, all as specified and as directed.
Supply and fix of HT overhead lines on existing poles with XLPE insulated AB (Aerial Bunched) cables 3-core X 95 sq mm + 1 x 70 sq mm including all fittings, complete all as specified and as directed. Make: Havells/ KEI/ Polycab
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for single core cable of size 95 sqmm including testing and commissioning, complete all as directed and specified.
Note 1:- (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Note 3:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
Damdoo Bhutia
Janata Enterprises
SANJAY KAUSHIK
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .