| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC TANTIPARA HOOGHLY GHAT P O HOOGHLY HOOGHLY PIN 712103 | HOOGHLY | WEST BENGAL | 712103 | ₹9.7 L | L1 | Accepted-AOC 1st Lowest |
| 2 | L2₹9.8 LRejected-Finance | ₹9.8 L | L2 | Rejected-Finance L2 |
| 3 | L3₹9.8 LRejected-Finance HOOGHLY GHAT HOOGHLY | HOOGHLY | HOOGHLY | WEST BENGAL | 712103 | ₹9.8 L | L3 | Rejected-Finance L3 |
| 4 | L4₹9.8 LRejected-Finance | ₹9.8 L | L4 | Rejected-Finance L4 |
Tender Value
₹9.7 L
EMD Value
₹20,000
Closing Date
3 Feb 2026, 11:00 amClosed
EXECUTIVE ENGINEER (AGRI-IRRIGATION) CHINSURAH
Executive Engineer (A-I), Chinsurah (A-I) Division, Nawabbagan, Chinsurah, Hooghly, 721101
Maintenance of Damaged Shed, Truss and Electrification of Sub Divisional Stores and Outside of Office of Chinsurah(AI) Sub-Division at Mouza-Kulihanda, Block Chinsurah Magra JL No-18, Plot no. 4907 in the District of Hooghly under Chinsurah (A-I) Sub
2026_WRDD_991404_4
WRDD/ EE(AI)HGY / eNIT 18 /2025-26
Open Tender
CIVIL WORKS
45 days
Chinsurah
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
9 Feb 2026
20 Jan 2026
5 Feb 2026
21 Jan 2026
3 Feb 2026
21 Jan 2026
Dismantling all types of masonry excepting cement concrete plain or einforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. (a) In ground floor including roof
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.In round floor including roof.(a) upto 150 mm. thick .
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge)
Suppling, fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45mm BMT ( Base Metal Thickness ) (0.50mm TCT ( Total coated thickness excluding paint), G550 (min 550 yield strength), of Zincalume metallic coating (IS15965) with high Solar Reflectance Index (SRI) value for better colling as per thermatech technology ,1000-1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg .The steel sheet shall be fastened with 40 micron zinc coated or 25 micron zinc-tin alloy coated , hex head, self -drilling screw as per IS 3566-2002 Class 3 fastener.The base steel shall be coated with zinc-aluminium alloy Zincalume ( AZ150 )(i.e. 55% Al, 43.4% Zinc, 1.6% Si) minimum of 150 g/m2 coating total on both sides, pre-painted with colorbond XRW ( xterior roofing, walling ) paint system of 35 micron Super Durable Polyester paint ( SDP ) with stable inorganic pigment with no lead contents confirming IS15965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheet at regular interval confirming genuinity of the material. in roof 0.5mm thick Sheet
Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.and stacking the material at site as directed.(Payment to be made on measurement of portion of roof or wall removed.)
Labour for lowering and stacking after dismantling in parts R.S. joists, channels, angles, tees, plates etc.complete as directed.
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, ground floor
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. Pakur Variety (distance from Nearest Bandel Stackyard 20 Km)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including ounding off or chamfering corners as directed and raking out joints including hroating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (b) 20 mm thick plaster
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including ounding off or chamfering corners as directed and raking out joints including hroating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (b) 15 mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm) ISMA 75X75X6
Labour for hoisting and placing in proper position (up to 1st floor level) departmental R.S. joists, channels, angles. Tees, plates etc. including fitting and fixing same with bolts and nuts, if necessary (but excluding cost of such bolts and nuts)
Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping. 300 mm lapping each way. With 0.60 mm sheet
Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping)
Galvanised or painted wind-tie made of M.S. flats, fitted and fixed complete including cost of necessary fittings. (b) Made with 50 mm. X 6 mm. flats Wind Tie 8 Nos 15 m long
Cement concrete flooring with high performance non-metallic floor hardener containing specially graded non-metallic hard wearing natural aggregates imparting floor hardness in the range of mohr scale 8-9 & capable of achieving 28 days compressive strength of 25 MPa with air content less than 3% applied asa dry shake @ 5Kg/sgm sprinkled to provide durable, non-slip monolithic floor for application of the topping over freshly laid concrete with under layer of 40 mm. thick cement concrete (1:2:4) (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as per specification of the manufacturer & as per direction of Engineer-in-Charge. [Note: Floor hardener is applied as dry shake using a power trowel when the floor concrete has stiffened sufficiently and bleed of water should not be visible on the top of the floor while the application started]
White washing including cleaning and smoothening surface thoroughly, . All floors: Two Coats (to be done on specific instruction)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor:
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Ground floor (Two Coat). Normal Acrylic Emulsion
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface : With super gloss (hi-gloss) -Two coats (with any shade except white)
Labour for taking out rolling shutter (only shutter portion) dismantling by parts for repair or (replacement of damaged parts only), rehanging and refitting the same in position after necessary repairs (excluding the cost of supply of new parts)
Renewing seam pipe for rolling shutter as per existing size and shape fitting, fixing complete.
Renewing side split pin for seam pipe for rolling shutter.
Oiling and greasing of rolling shutter and repair to in side lock.
Renewing profile of rolling shutter including fitting fixing complete as per existing size and shape.
Renewing spring of rolling shutter as per existing size and shape including fitting fixing complete.
Easing and oiling, cleaning collapsible gate and repairing to locking arrangements.
Reparing collapsible gate by cutting out all rivets as necessary re- assambling all members including welding pieces of channels, sraightening bent bars and rivetting with new rivets and fitting in position and painting two Zone: Howrah/Hoogly
Painting with superior quality aluminium paint of approved make and brand including smoothening surface by sand papering etc. on steel surface : (b) Two coats
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 X 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sq mm) single core stranded 'FR' PVCinsulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MSCRC sheet metal (16SWG) switch board cum J B on wall complete with 2no. suitable size “Ph&N” copper bar incl. bakelite/Perspex (wallmatchingcolor) topcover 3 mm thick and incl. 175mmx100mmx65mm inspectio nbox, making earthing attachment, painting the MS box and mending good the damages to original finish. Average run 6 mtr
Average run 8 mtr
Average run 10 mtr
Average run 12 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. akelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish. On Board
Supplying & Fixing CRC sheet metal (16 SWG) JB-cumSwitch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 150 mm x 100 mm x 65 mm
150 mm x 100 mm x 65 mm
300 mm x 200 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 150 mm x 100 mm x 65 mm
300 mm x 200 mm x 65 mm
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
Supply & Fixing 240 V, 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Fixing only TPN switch fuse units in Sheet Steel enclosure with HRC fuses on angle iron frame on wall for 32A to 400A
Fixing only TPN MCBDB in Sheet Steel enclosure (4 to 12 way) on flat iron frame on wall including Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection DP 6-32 A Havells
Fixing only MS sheet metal busbar Chamber on angle iron frame on wall 4 bars 100/125 Amps
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. (a) Solid GI wire. (iii) No. 8 SWG
Fitting & fixing of Starter (Direct on Line or Star-Delta/Auto- Transformer) with Nuts & Bolts fixed on Angle iron frame on wall and making necessary connection with the electrical iii) Star-Delta/Auto-Transformer Starter (Above 15 HP upto 25 HP)
Fixing only Voltmeter/Ammeter/Energy meter with screws & other fixing materials incl. making necessary holes and connections
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to IEE regulation and as per direction of EIC. (Brand:Gloster/Havells/Finolex) (ii) 3C X 16 sqmm copper cable conforming to IS 694 [Busbar to 63 A, TP Main switch and 63 A TP switch to Motor starter]
Supply & Fixing EI danger board on wall b) 20 cm x 30 cm (8"x12") (Rate for Arambagh Sub-Division)
Earthing with 50 mm dia GI pipe3.64 mm thickx3.04Mts. longand 1x4 SWG GI (HotDip) wire(4Mts. long),13 mm dia x80 mm long GI bolts, doublenuts, doublewashersincl.S& F 15 mm dia GI pipe protection(1Mts. long) to be filled with Bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Supplying & fixing sheet metal (16SWG)Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required–( As per Drawing no. 470 of PWDS pecification Book – May 1991) 4 bars 415 V, 100/125 A;Al. bars [85mm long] 4 x 25x5mm; 500x150mm Dimension of Sheet Metal Box
Motor controller, IS:60947 , 25 HP 3Ø Electromagnetic Star-Delta motor controllers with 4 pole heavy duty Power contactor, single phasing preventer and normal protective features, MCB, Indicators, push buttons, Ammeter & Voltmeter, all in IP54 enclosure of min 16swg, CR sheet steel, 10 tank process powder coat painted and as per technical specification.
Switch Fuse Unit, ISI marked, IS:60947, 100A Switch Fuse Unit TPN
Supply of 1200 mm sweep Ceilling-fan Model -1200mm (Orient/Crompton Greaves / Usha), as directed by EIC. (Model (CF 1200 ESLA W/O REG ANGLE WHITE / COPPER GOLD)
S & F 6W high performance low height LED down lighter in robust PDC housing narrow rim renders spot-light fittings, 4000K, 5700K, 3000K as directed by EIC.(Make- Philips/ Wipro/ Crompton/Mescab/etc.). (Model N295B LED6S-6500 PSE WH S2, HSN CODE 9405)
Smart Bright Essential is a street lighting luminaire delivering >100 lumen/watt with PDC housing and street light optics to ensure uniform distribution out door 75 W LED light fittings OF PHILLIPS or equivalent make. (Model BRP032 P LED75 CW SLR PSU GR SPD)
GST @ 18% on Iten 1
Labour Welfare Cess @ 1% on Iten 1 incl. GST
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tendernotice_2.pdf
PDF • 0.55 MB
BOQ_2424137.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid