| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NORTH SITE TROMBAY MUMBAI 400 085 | MUMBAI SUBURBAN | MAHARASHTRA | 400085 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical The agency not fulfills NIT criteria in terms of executing similar nature of work as per i |
Tender Value
₹80.9 L
EMD Value
₹1.6 L
Closing Date
13 Mar 2024, 3:00 pmClosed
Chairman GB
3rd floor VS Bhavan Mumbai
External repair and painting work of minimum 10 storeys building with experience in carrying out Aluminium works / completing balance construction of one building minimum up to 10 storey with experience in carrying out Aluminium works
2024_DCSEM_797721_1
DCSEM/CQD/QSB/23-24/NIT/114 dt.27.02.2024
Open Tender
Civil Works
Item Rate
304 days
Anushaktiagar, Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹0
₹1.6 L
15 Apr 2024
27 Feb 2024
15 Mar 2024
27 Feb 2024
13 Mar 2024
27 Feb 2024
27 Feb 2024 - 1 Mar 2024
Amount
ABSTRACT SHEET
PART - I - CIVIL WORKS
Description of Work / Item(s)
Amount
PART - I - CIVIL WORKS
a) Supplying and erecting M.S. tubular scaffolding using 'H' frames of M/s. Acrow India (or) equivalent with horizontal and vertical rows @ suitable spacing as per I.S. specification which should be suitably overlapped at junctions and cross braced wherever required and securely tied, supporting the scaffolding with building members as permitted by the Engineer-in-Charge, including all pipes of scaffolding shall be atleast 40mm n.b. dia heavy class seamless pipe, providing necessary safety belt and helmet to the workers and dismantling & taking back the scaffolding, safety belt and helmet after the repair works are completed all as per specifications and directed by the EIC.
a)M S Steel scaffolding
Repairs to damaged RCC structural members at all locations/ floors using polymer modified cementatious mortar, for strengthening the existing RCC structural members using acrylic based polymer and comprising the following operations: 1. Breaking cracked / spalled concrete members along the cracks with plaster, including removing and stacking of all unserviceable material at site,simultaneous transportation and disposed at a location in Anushaktinagar as identified by EIC. complete all as per specifications and as directed by the Engineer-in Charge. 2. Exposing and cleaning the reinforcement thoroughly by light tapping / wire brushing of using strong emery paper and finally by acetone /rust remover of Dr. Fixit / Anuvi chemicals / Fosroc or other eqivalent. 3. Applying a coat of polymer and cement slurry in the ratio 1:1 by volume to the reinforcement bars. 4. Polymer required for the work shall be procured by the Agency from approved Manufacturers Like M/s Astra , M/s Anuvi, M/s Apcotex or other approved equivalent manufacturer confirming to technical requirements as below and the invoices/challans etc to be submitted to EIC for record. Appearance: Milky white Ph- value : 9-10 Specific gravity : 1.055+/-0.005 Solid contents(%w/w)-: 44+/-1 Viscocity at 25 degree C temperature (in sec): 15-20 Testing of the material as per relevant codes at NABL approved third party Lab. is to be done by the Agency for every batch/lot of supply. 5. Bond coat should be applied @ 0.37 ltr./layer/sq.m. 6. Minimum FM of silica sand should be 2.10
a) Building up with polymer modified cementatious mortar for RCC structural members etc. in layers not exceeding 20 mm in a day (proportion – cement 50 Kg. : Silica sand 125 Kg. : polymer liquid 10 ltrs.) with necessary bond coat (polymer : Cement = 1:1 by volume) for tack coat and also for subsequent layers using polymer including curing, covering the flooring /window with tarpaulins or equivalent covering material to avoid deposition of polymer mortar and cleaning of floor / windows thoroughly on completion of repair work etc. complete all as per specifications and as directed by the Engineer-in-charge. Polymer used for this work in KG shall be measured for payment.
b) Repairing with polymer bonded mortar up to 35mm thick in layers of not exceeding 20mm (with out chicken mesh) in a day (proportion- cement 50 Kg : silica sand 125 Kg) with applying protection coat / bond coat to reinforcement, bond coat to old concrete and bond coat for every successive layers of 20mm thick in proportion polymer : Cement-1:1 by volume as per specification including covering the floor/windows with tarpaulin or equivalent covering material etc., and cleaning after repair etc., complete all as per specifications and as directed by the Engineer in charge. The rate is inclusive of supplying and applying protection coat /Bond coat of polymer.
c) Repairing with polymer bonded mortar average 70 mm thick in layers not exceeding 20 mm in a day (proportion – cement 50 kg : silica sand 125 Kg. ) with applying protection coat / bond coat to reinforcement and bond coat for every successive layers of 20 mm thick in proportion Polymer : cement – 1:1 by volume as per specification including one layer of Chicken mesh 22 gauge, including covering the floor / windows with tarpaulin or equivalent covering material etc. and cleaning after repairs, curing etc. complete all as per specifications and as directed by the EIC. The rate is inclusive of supplying and applying protection coat /Bond coat of polymer.
Sand faced cement plaster 20 mm thick in CM 1:4, two coats using factory manufactured pre mix/ready mix of 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd/ 'Build well' Ready mix plaster of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd/ Readymade Polymerised Drymix plaster -Silicoplast of M/s. Precise Conchem Pvt.Ltd. or other approved equivalent make, having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnical mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 12 mm thick and finishing coat of 8 mm thick final rendering,including using richer mix for making corners if necessary, at all floors and levels, including making grooves of existing size wherever required, including cleaning the surfaces, including membrane curing by applying one coat brush, roller or spray using acryalic based curing compound i.e. Resikure of M/s Anuvi Chemicals/ Concure Of M/s FOSROC or other equvalent ( as per manufacturer's specification ) including removing existing damaged/ worn out plastering and disposal of debris at a location in Anushaktinagar as identified by EIC etc. complete all as per specifications and as directed by the EIC .
Rough cast cement plaster 25 mm thick in two coats, for base coat in CM 1:4 using factory manufactured pre mix/ready mix of 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd/ 'Build well' Ready mix plaster of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd/ Readymade Polymerised Drymix plaster -Silicoplast of M/s. Precise Conchem Pvt.Ltd. or other approved equivalent make,having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnical mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces at all floors & levels for base coat in 1:4, 12mm thick and finishing coat of 13 mm thick with cement and gravel in proportion of 1:3, including cleaning the surfaces, including membrane curing by applying one coat brush, roller or spray using acryalic based curing compound i.e. Resikure of M/s Anuvi Chemicals/ Concure Of M/s FOSROC or other equvalent ( as per manufacturer's specification ), including making grooves of existing size wherever required, including removing existing damaged /worm out plastering and disposal of debris at a location in Anushaktinagar as identified by EIC etc. complete all as per specifications and as directed by the EIC .
Cement plastering using factory manufactured pre mix/ready mix mortar in CM 1:4 of pre mix/ready mix of 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd/ 'Build Well ready mix plaster ' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd / Readymade polymerised Drymix Plaster - Silicoplast of M/s. Precise Conchem Pvt. Ltd. or other approved equivalent make, having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnical mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied on internal wall and ceiling finished smooth with neeru over brick walls or concrete surfaces at all floors and levels, including curing and removing existing damaged/ worn out plastering and disposal of debris at a location in Anushaktinagar as identified by EIC etc. complete all as per specifications and as directed by EIC.
a) 12 mm thick
b) 15 mm thick.
Providing and applying one coat of base primer (Apex Ultima protect of M/s. Asian paints or Aquatech of M/s. ICI Dulux or equivalent) and two top coats of acrylic water proof exterior coating of Weathershield flexx rainproof system of M/s. ICI Dulux or other approved equivalent make and shade over the sand face / form finished surfaces / rough cast plaster at all locations as required, thoroughly mixed and applied at an interval of 6-8 hours for each successive coats and ensure consumption of 0.47 ltr/Sqm for 3 coats,(base coat @.29 Ltr/sqm & two top coats @0.18 Ltr/sqm ) for sand face surfaces including preparation of surface, cleaning and filling the cracks and crevices with Latex caulking crack filler etc. Complete generally as per the manufacturer's specification and as directed by the EIC.
a) Over sand faced plastered / Form finished surfaces
b) Over rough cast plastered surfaces
Repainting of old painted surfaces with two coats synthetic oil bound distemper of approved shade and make over one coat of approved cement primer, including thoroughly scrapping, removal of old paint if any, sand papering & preparing the surfaces, applying approved stucco putty to entire surface to fill up crevices mild depression etc. scaffolding including cleaning of floors, doors & windows etc.& disposal of debris at a location in Anushaktinagar as identified by EIC etc. all as per specifications and as directed by the Engineer-in-Charge.
Providing and applying shrinkage crack filler of Dr.Fixit Crack X Paste / smart care crack seal of Asian paint in paste form / Aquatech crack filler in paste form of Dulux or other equaivalant material including opening the loose part of the existing crack , making the same in V - shape in required depth & width, cleaning the groove by removing dust, oil, grass, loose particals etc., press the crack filler in to the crack one time only with a spatula or putty knite and level the surface etc. completed all as per manufacturer's specifications and as per direction of the engineer-in-charge.
Brick work 230 mm thick in super structure Class designation 75 in cement mortar 1:4 using well burnt locally available bricks of approved quality including scaffolding, raking out joints, curing etc. complete all as per specifications and as directed by the Engineer-in- charge.
Providing and fixing structural steel of approved manufactures (yst=250N/mm2) using steel sections such as angles, flat,tees, channel etc. of required sizes at all levels and locations including cutting, fabricating, welding, erecting & fixing inposion, necessary scaffolding and including painting one coat Zinc chormate primerover shop coat of approved anti corrosive primer and two coats of synthetic ename lpaint of approved make and colour on all exposed surfaces etc. complete all as directed by the Engineer-in-charge.
Dismantling carefully the existing RCC Grill along with finishing by chiselling without damaging existing structure including cutting the reinforcement by gas cutting etc. disposing debris intside colony at disignated location identitfied by the Engineer-in charge etc. complete
Supplying, fabricating and fixing in position at all floors factory made Aluminium grill /Aluminium sliding/top hung/fixed/ adjustable louvered windows & ventilators with rivit joint of specified size, made of integrated bronze anodised matt finished (15micron thick) aluminium section (extruded) , including for making exhaust fan frame work, handles of specified size etc, of approved manufacutres for following types with extruded sections of Jindal / Indal / Aluminax or other approved equivalent make of approved sections with size and wights as directed for frames and shutters(including wastages if any) wherever mitred joints required confirming to relevant IS specifications with all approved Bronze anodised aluminium fittings and accessories, latching fixture, 2/3 rollers with ball bearing of superior quality all as shown in the drawing including providing and fixing aluminium channel beading/glazing clips fixed with necessary bronze anodised screws, grouting the gap with sealant and including dismantling of existing window frame and shutter, glass and depositing same to dept store etc all complete generally as per drawing, specifications etc, all as directed by Engineer-in-Charge.. Note :Payment shall be made per Kg basis.Aluminium sections such as shutter frames, track window/door frame/beading channel for glass adjustable louvers etc.,shall only be measured linearly as per actual/finished cutting size nearest to centimetre and multiplied with sectional weight of the individual section and the total quantity of aluminium section will be arrived at for payment without any allowance for wastage.
a) All Aluminium sections for window, grill and other work.
Providing and fixing aluminium grill 10mm thick DECO GRILLE make model no DG202 (Red colour) in approved colour anodising of Min 15 mircon with a opening size of 60mm X 45mm and minimum weight of 4.282 kg/Sqm including providing and fixing suitable F & H frame section outer frame and mullion fixing with screw, double tubular necessary scaffolding complete. all as per specification and as directed at site by the Enginer-in-Charge (Aluminum alloy shall be of 6063-T6 with yeild strength of 6.5Kg/Sqm)
G-TECH CONSTRUCTION & FABRICATORS
G-TECH CONSTRUCTION & FABRICATORS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .