Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-Finance | ₹39.0 L | L1 | Accepted-Finance L1 |
| 2 | L2₹42.7 LRejected-Finance | ₹42.7 L | L2 | Rejected-Finance L2 |
| 3 | L3₹43.0 LRejected-Finance | ₹43.0 L | L3 | Rejected-Finance L3 |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | DAKSHNA MOORTHY D H L3 | WORK CONTRACT L1 | S NINGAPPA L2 |
|---|---|---|---|---|---|---|
| 1.00 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates | 16.33 | cum | 4,500 ₹86,712.30 | 4,500 ₹86,712.30 | 4,932.2 ₹95,040.60 |
| 2.00 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | 14.33 | cum | 5,200 ₹87,928.88 | 5,500 ₹93,001.70 | 5,805.08 ₹98,160.36 |
| 3.00 | Removing and resetting of precast kerb stones fixed with CM 1:3 fixed and finished in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) | 118.7 | m | 250 ₹35,016.50 | 90 ₹12,605.94 | 38.14 ₹5,342.69 |
| 4.00 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification) | 91.83 | sqm | 1,100 ₹1.2 L | 850 ₹92,105.49 | 1,101.69 ₹1.2 L |
| 5.00 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment | 13.4 | m | 150 ₹2,371.80 | 1,000 ₹15,812 | 40.68 ₹643.20 |
| 6.00 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 100 mm size | 35 | m | 850 ₹35,105 | 350 ₹14,455 | 241.53 ₹9,975.35 |
| 7.00 | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -II Material | 29.21 | cum | 2,500 ₹86,169.50 | 1,900 ₹65,488.82 | 2,457.63 ₹84,709 |
| 8.00 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | 37.08 | sqm | 1,100 ₹48,129.84 | 750 ₹32,815.80 | 966.1 ₹42,271.20 |
| 9.00 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | 343.95 | sqm | 300 ₹1.2 L | 300 ₹1.2 L | 381.36 ₹1.5 L |
| 10.00 | Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 12 mm thick | 5.8 | sqm | 2,500 ₹17,110 | 2,100 ₹14,372.40 | 2,372.88 ₹16,240 |
Tender Value
₹49.2 L
EMD Value
₹98,329
Closing Date
3 Dec 2025, 3:30 pmClosed
Registrar
IISc, Bangalore
Civil Repair and Painting works at Management Studies Main Building, Annex Classroom and Annex Lab in IISc
2025_IISC_885489_1
IISc/Tender-CIV-16/2025-26
Open Tender
Civil Works
90 days
IISc, Bangalore
As Per Tender Documents
2 documents required · 2 mandatory
₹0
₹98,329
MS Teams Online
19 Jan 2026
13 Nov 2025
4 Dec 2025
14 Nov 2025
3 Dec 2025
27 Nov 2025
24 Nov 2025
Amount
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Removing and resetting of precast kerb stones fixed with CM 1:3 fixed and finished in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)
Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification)
Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment
Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 100 mm size
Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -II Material
Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge
Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 12 mm thick
Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..
French spirit polishing :Two coats on new works including a coat of wood filler to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete as per specifications and as per directions of Engineer in charge.
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.Wedge expansion type Fastener with threaded dia 12 mm.
Providing and fixing double action hydraulic floor spring of approved brand manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineerin- charge: With stainless steel cover plate minimum 1.25 mm thickness including cost of materials, labour, usage charges of machinery complete as per specifications.
Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.30 mm thick both side commercial
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :125x64x1.90mm
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete:125x85x5.5 mm (heavy type)
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10mm
Providing and fixing bright finished brass handles with screws etc. complete:Brass handles 125 mm with plate 175x32 mm
Providing and fixing door latch with necessary screws etc complete Bright finished brass latch
Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size – 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm)
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 50x12 mm
Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including,grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm
Providing and fixing factory made Green certified, Anti Termite, UV resistant,high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness
Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately).
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 300 mm length
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
Providing and fixing Angle cock medium with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Premium
Providing and grouting tile joints, Cutting the tile joints with the help of cutting machine (width 3mm-15mm) and filling with of matching shade, using three component Epoxy based tile joint filler, non-sag waterproof grout, chemical and UV resistance, Pot life ≤ 60 mins, VOC (EPA 24) < 8gm/kg and water absorption after 7 days < 0.5g Joints shall be clean, dry, free from dirt, etc prior to application. Apply tile grout using a rubber trowel/grout floater, press firmly into joints, ensure complete fill and remove excess grout from surface using suitable method. The work shall be carried out as per the directions of the Engineer in charge.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking to the appropriate disposal area as per direction of Engineer-in-charge.Up to 10 mm thick
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge.Of area 3 m² and below
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge.Of area beyond 3m²
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge
Removing of existing old or broken wash basin / urinals/ Indian Water closet/ European Water closet and disposing it with all cost and conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer in-charge. (Old CC paver blocks shall be supplied by the department free of cost).
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge to the appropriate disposal area.
Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe).
Renewing glass panes, with wooden fillets wherever necessary:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/m²)
Removing the old paint or polish from wood and / or wood based surface with paint remover of approved brand / manufacturer and making surface even including cost of materials, labour, complete as per specifications
Removing the glazed tiles in patches in area exceeding 10 tiles and not exceeding 5 sqm including removing old tiles preparing surfaces and laying or setting new or old tiles complete including cost of materials, ( excluding cost of tiles ) labour, complete as per specifications.
Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven percussion type including cleaning reinforcement with wire brush complete as per direction of Engineer incharge of work.
Cleaning of reinforcement from rust by Alkaline solution thoroughly as per direction of Engineer in charge of work.
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).12 mm average thickness.
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).25 mm average thickness in 2 layers.
Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Handles 200mm
Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 200mm
Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 300mm
Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 150x10mm
Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts SS Door stopper 75mm
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.Note:- The elevational area of the scaffolding shall be measured for payment purpose.
Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Dark shade pigment using ordinary cement
Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge
Providing and fixing Partition made up of 10mm thick toughened glass for the opening of size approximately 4.00m*2.40m, of approved make such as saint gobain,modiguard or equivalent. Glass panes to be fixed with powder coated aluminium slim frame of approved make of Dorma,ozone or equivalent of size 25mmx22mm including fixed sections,folding profile,T joint ,I joint,L joint sections,Gasket for fixing glass panes,gasket for Door jamb,Thread rods,foam tape,double side acrylic tape etc.. as per direction of Engineer in charge (Note: The cost is inclusive of transportation and fixing charges nothing will be paid extra)
Providing and fixing on wall face Unplasticised - PVC SWR moulded fittings/ accessories for Unplasticised SWR pipes conforming to IS :14735 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Plain 110mm bend.
Fixing avilable granite stone of area less than 2.00 sqm in linear as well as curvilinear portions of the building all complete. slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shadeall complete as specified and as directed by the Engineer-in-Charge
Supplying heavy gauge PVC Conduit Pipe dia2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19 mm dia 2 mm thick
Supplying heavy gauge PVC Conduit Pipe dia2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 6 Amps one way Switch
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 6 A Three Way socket
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 16 A One Way Switch
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. RJ 45 /I.O Outlet Cat 6
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 12 Module
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 1-2 Way
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 3 Way
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 4 Way
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 6 Way
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 8 Way
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 12 Way
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or wiring with specified IS-694:confirming to latest amendments including terminations with copper lugs - 1.5 mm2
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or wiring with specified IS-694:confirming to latest amendments including terminations with copper lugs - 2.5 mm2
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or wiring with specified IS-694:confirming to latest amendments including terminations with copper lugs - 4.0 mm2
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or wiring with specified IS-694:confirming to latest amendments including terminations with copper lugs - 6.0 mm2
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or wiring with specified IS-694:confirming to latest amendments including terminations with copper lugs - 10.0 mm2
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length and copper lugs in a wood/PVC round block. complete for each outlet. - Short point upto 3m from tapping point to out let via switch box
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length and copper lugs in a wood/PVC round block. complete for each outlet. - Medium point above 3m upto 6m from tapping point to out let via switch box
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length and copper lugs in a wood/PVC round block. complete for each outlet. - Long point above 6Mtr upto10Mtr from tapping point to out let via switch box
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. - 8 Way SP & N-Double door
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. - 12 Way SP & N-Double door
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. - 6 Way TP & N-Double door
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. - 4 Way TP & N-Double door
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. - 8 Way TP & N-Double door
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32 A SP
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 40 A DP
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 50-63 A TPN
Supplying and fixing of AC type RCBO on existing MCB distribution board using necessary fixing materials, C curve, capacity of 10 KA and complete wiring as required confirming ot IEC 60947 40A double pole RCBO, 240 V, 30mA sensitivity Make: Legrand, L&T, Schneider
Supplying and fixing of AC type RCBO on existing MCB distribution board using necessary fixing materials, C curve, capacity of 10 KA and complete wiring as required confirming ot IEC 60947 63A Four pole (4P) RCBO, 415V, 30mA sensitivity Make: Legrand, L&T, Schneider
Supplying and fixing of DP sheet steel enclosure on surface/recess along with 32/40 A, 240V C curve DP MCB complete with connections, testing and commissioning etc. as required
Supplying and drawing UTP-CAT 6E LAN cable.
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.- 2 Pair
Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination.- 10 Pair
Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. - 25 mm
Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. - 50 mm
Removing of existing switch boards, energy meter, old aluminium wiring, old earth conductor pipe shifting to store and cleaning of light fittings, exhaust fans etc as suggested by the Engineering-in-charge - Khallasi
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose,necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.
Releasing the existing fan checking, testing and installation at the same place.
Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V@ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W
Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure de cast/extruded aluminium housing, with spring loaded false ceiling clamps,Power LED swith CCT 6500 degreeK, CRI>70%. efficacy>100lumen perW,120 degree beam spread, life>25000 burning hours and Compliance to IS10322/IEC 60598, LM79 & LM80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF>0.95, power loss should<5%of lamp Wage., shortcircuit & open circuit protection to be integrated in the circuit, THD less than 20%,Life as per LM79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' 36 W
Supplying fixing and wiring earth electrode for grounding of lifts, transformers,DG sets etc.using 40mm dia 2.9mm thick 2.5m long GI pipe with GIf unnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber.The connection from the electrode is to be established through GI strip using GI bolts and nuts.
Supplying and laying 6 SWG G.I. wire at 0.50 metre belowground level for conductor earth electrode, includingconnection/ termination with GI thimble etc. as required.
Supplying and installing following size of perforated Hot dipped galvanized iron cable trays with covers (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying push button operated direct online starter with an anti weld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anti corrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP.
Supply of materials- 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, Copper Control Cable as per IS- 554 (Part-1) - 4c x 4 sq mm Cu
Repair to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20 mm thick in cement mortar 1:4 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50 m including curing cost of materials, labour, complete as per specification.
Supplying and fixing 30A, 415V, TPN industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30A C curve TPMCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket outlet and complete with connections , testing and commissioning as required.
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm)
Laying of one number of PVC insulated or PVC sheathed/ XLPE power cable of 1.1kV grade of following size on wall surface as required - up to 35 sq mm(clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1kV grade as required. - 3.5x25 sq mm (28mm)
Supplying and fixing of PVC trunking on the wall/ ceiling/ floor using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm etc. as required. - DLP TRUNK 105 mm X 50 mm
Supplying and fixing of PVC cover on the wall or ceiling using necessary materials like bends, junction box, elbows, screws etc. as required. -DLP FX COVER 85 MM
S NINGAPPA (BID ID -3327297)
DAKSHNA MOORTHY D H (BID ID -3327070)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
TDManagmntStudies.pdf
Tender Documents • 3.37 MB
BOQ_930735.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid