Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC 130 KALIKATALA PARK S P O BANSDRONI KOLKATA 700070 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700070 | L1 | Accepted-AOC 1st lowest rate | |
| 2 | L2₹3.0 L+₹152.79 (0.05%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest rate | |
| 3 | L3₹3.0 L+₹336.10 (0.11%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest rate |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
4 Mar 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Addl. District Magistrate, Uttar Dinajpur
office of the District Magistrate, Uttar Dinajpur
211/Planning_Dev
2024_DMUD_674586_1
211/Planning_Dev
Open Tender
CIVIL WORKS
Item Rate
30 days
Raiganj
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹6,000
28 Nov 2024
26 Feb 2024
6 Mar 2024
26 Feb 2024
4 Mar 2024
26 Feb 2024
Amount
INSTALLATION OF 1 NO. SOLAR SUBMERSIBLE PUMP BORING ---------Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(a) For Depth upto 150 mtr for 40 mm diameter Tubewell with Top Enlargement of 100 mm diameter..............(i) 40 mm diameter.
(ii) 100 mm diameter.
Supply of PVC pipes & fittings schedule -80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).......................(a) 100 mm dia.
(b) 40 mm dia.
(c) Reducing socket ( 100 mm X 40 mm).
Supplying PVC strainer of approved make with adapter conforming to I.S. 12818 specifications....................(i) 40 mm dia.
Supplying , fitting and fixing Steel Cutter piece upto 450 mm long with Sockets............(i) 40 mm dia.
Supplying, fitting and fixing G.I. cap at top...................(i) 100 mm dia
Supplying medium sand for shrouding, Finess Modulus 1.80 to 2.00.
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)...............32 mm dia
25 mm dia
(f) (ii) Polythene Bib Cock / Stop Cock with plastic inlet (EMCO / ATLAS or equivalent)..........15 mm. Dia
Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007....................25 mm Dia
PWD SOR (S & P) Page No. 89, Item No. 4 (7th Corrigenda & Addenda for Schedule of rates PWD (WB) w.e.f 01.11.2017) / Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm ntermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. For - JSW/ JSPL/ SHYAM/ SRMB/ BMASL/ ELECTRO STEEL/ SSL
Local Market Rate / Supply, delivery & installation of 900 watt peak capacity Solar photovaltatic array along with 1.00 H.P. capacity D.C./ A.C. submerssible pump in the same bore (designed to use with Solar Power) of approved brand whose output is not less than 2000 Ltr/hours at 40 Mtr. head including supply of all necessary materials (Hanging pipe, Copper weir for supporting to hang the Submersible etc.) of approved quality, labour etc. with all allied works as per direction of the E.I.C. [D.C./ A.C. Submerssible Pump and controller should carry a warranty of 1 year directly from the manufacturers]
Local Market Rate / Installation of Solar photovaltatic array Panels on the structure as per standard & approved drawing which will grouted either ground based by construction of foundation concrete or integrated with the staging steel structure of water tank. The Solar Panels will then be connected to the Pump Controller which in turn will be connected to the pump as well as the level indicator of the water tank as per direction of the E.I.C. [Steel structure of water tank and Solar Pannel which components will be Galvanized on MS are carry a warranty of 5 years and Solar Panels will also carriy a warranty as per attached technical specs]
Local Market Rate / Installation of Iron Removal Unit which does not use electricity attached with the water tank. The Iron Removal Unit must have the approved quality/ brand whose capacity of oxidation filter is not less than 200 Ltr/ hours. etc. with all allied works as per direction of the E.I.C.
INSTALATION OF PVC WATER TANK OVER STEEL FABRICATED STRUCTURE WITH NECESSARY PLUMBIBNG WORKS
Providing & fixing Concrete Sign Board as per IRC specification of size 900 x 750 x 37 mm. thick made with RCC 1:1½:3 with pakur variety stone chips reinforced with double layer IRC febric (75 x 75 mm. mesh) and fixed with necessary nuts & bolts on two RC precast posts 100 mm. x 150 mm. of height 2.65 m. of which top 750 mm. is of section 100 x 13 mm. and 1.90 metre above GL & 0.75 metre below GL including digging hole, repacking the same with cement concrete 1:3:6 with jhama khoa or with local stone chips etc. complete including painting two coats on both faces lettering sign marks etc. as per direction of the Engineer-in-Charge. (The rate is inclusive of cost of reinforcement, concrete, shuttering, nuts & bolts, washer etc. complete.)
ROHITASYA MAJUMDER
SHIV SHAKTI ENGINEERING WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .