Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.5 LAccepted-AOC 3838 2ND FLOOR SECTOR 46 C CHANDIGARH UT 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | L1 | Accepted-AOC The lowest bidder | |
| 2 | L2₹24.7 L+₹3.5 L (16.4%)Rejected-AOC | L2 | Rejected-AOC Other than the lowest bidder |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
12 Nov 2024, 6:00 pmClosed
GE (I) JUTOGH
GE (I) JUTOGH, JUTOGH CANTT SHIMLA (HP) - 171008
REPAIR AND MAINTENANCE OF EXTERNAL WATER SUPPLY NETWORK, SERVICING OF PUMP SETS, TANK CLEANING ALONGWITH ALLIED WORKS AT JUTOGH, KUFRI, SANJAULI, RMS CHAIL AND KELVIN GROVE UNDER GE (I) JUTOGH
2024_MES_675825_2
GE(I)/JUT-51 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
JUTOGH
CLASS E CATEGORY a (ii)
6 documents required · 6 mandatory
₹500
GE (I) JUTOGH
₹44,000
Yes
23 Jan 2025
24 Oct 2024
14 Nov 2024
24 Oct 2024
12 Nov 2024
30 Oct 2024
24 Oct 2024 - 28 Oct 2024
Amount
Excavation in trenches not exc 1.50 metre wide not exc 1.50 metre deep in soft/ loose soil for laying of pipe line and getting outcomplete all as specified and directed.
Returning filling in, including spreading leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removal of excavated soil surplus to the requirement to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Taking up/down steel tubing connection from trenches incl connected fittings/accessories complete of 100 mm bore, complete all as specified and directed.
All as per Srl item No.4.00 above but of 80 mm bore, complete all as specified and directed.
All as per Srl item No.4.00 above but of 50 mm bore, complete all as specified and directed.
All as per Srl item No.4.00 above but of 40 mm bore, complete all as specified and directed.
All as per Srl item No.4.00 above but of 25 mm bore, complete all as specified and directed.
All as per Srl item No.4.00 above but of 20 mm bore, complete all as specified and directed.
Supply, fixing & testing in replacement on wall or laid under floor GI pipe 25mm medium grade ISI marked with all fittings complete all as specified for following sizes, complete all as specified and directed.
All as per Srl item No.10.00 above but of 20 mm bore, complete all as specified and directed.
Supply, laying & testing in replacement in trenches GI pipe medium grade ISI marked with all fittings/flanges complete all as specified for 100 mm bore complete all as specified and directed .
All as per Srl item No.12.00 above but of 80 mm bore, complete all as specified and directed.
All as per Srl item No.12.00 above but of 50 mm bore, complete all as specified and directed.
All as per Srl item No.12.00 above but of 40 mm bore, complete all as specified and directed.
All as per Srl item No.12.00 above but of 25 mm bore, complete all as specified and directed.
All as per Srl item No.12.00 above but of 20 mm bore, complete all as specified and directed.
Supply and fixing in replacement of gun metal gate valve ISI marked with iron wheel screwed down high pressure screwed both ends for iron pipe of size 50mm bore including fixing nipple, union or fitting as per site requirement including taking down old unserviceable valve, complete all as specified and directed.
All as per Srl item No.18.00 above but 40mm bore, complete all as specified and directed.
All as per Srl item No.18.00 above but 25mm bore, complete all as specified and directed.
All as per Srl item No.18.00 above but 20mm bore, complete all as specified and directed.
S&F in replacement Ductile iron sluice valve 200 mm dia, flanged ends, PN rating 1.6, working parts conforming to IS :14846, and flanged ends having drilling as per IS:1538 including taking down old unserviceable sluice valve complete all as specified and directed.
All as per Srl item No.22.00 above but 150 mm bore, complete all as specified and directed.
All as per Srl item No.22.00 above but 100 mm bore, complete all as specified and directed.
All as per Srl item No.22.00 above but 80 mm bore, complete all as specified and directed.
S&F in repair SS304 fire hydrant landing valves, Inlet 80mm & Outlet 65mm, as per IS:5290, Flanged Ends to IS:1538 confirming to IS- 5290, complete all as specified and directed.
S&F in replacement Ductile iron NRV PN 2.0 with flanged ends with nut-bolts and rubber gasket suitable for pipe of size 100 mm including taking out the unserviceable non return valve of any type from the pipe complete all as specified and directed.
S&F in replacement Foot valve with flanged ends with nut-bolts and rubber gasket suitable for pipe of size 100mm including taking out the unserviceable foot valve from the pipe complete all as specified and directed.
M&L for brick masonary valve pit of size 1200 x 1200 x 1050mm dimensions, one brick thick valve pit of following internal dimension with two nos. of RCC slab cover of siutable size with handle to lift atleast 75mm thick having provision of valve key slot , earth work and PCC in foundation 1:3:6, Type C-2, using 40mm graded crushed stone aggregete 150 mm thick, PCC in coping on top 1:2:4,Type B-1, using 20mm graded crushed stone agregate 100mm thick including rendering 15mm thick and two coat of white wash on exposed surfaces on external wall above ground level incl demolition of old unserviceable existing one complete all as specified and directed. Note: RCC slab rate are deemed to be inclusive in the quoted rates.
All as per Srl item no 29.00 above but size 900 x 900 x 900mm, complete all as specified and directed.
M&L for dismantling centrifugal induction motor from foundation and transport to work shop for rewinding after taking out burnt winding wire from motor of capacity 100 HP three phase, rewinding with copper wire of suitable gauge or as per existing gauge complete including all required insulation material and transport back to site after testing and commissioning complete all as specified and directed. Note : a) The Motor testing will be done before installation on No load for any unbalance load and should be free from vibration and if found unsatisfactory no payment will be done to contractor for defective motor. b) Necessary thimbles, lugs, insulation tape, nut bolts and all items required for installation of motor at site will be included in the rate quoted by the contractor. No extra payment will be done to contractor. b) After dismantling of induction motor repair of PCC foundation work will be executed during the winding work with replacement of base frame of angle iron of existing size of angle if found damaged or deformed. These items will be measured and paid separately under relevant items.
All as per Srl item No. 31.00 above but of capacity 75 HP, complete all as specified and directed.
All as per Srl item No. 31.00 above but of capacity upto 20 HP, complete all as specified and directed.
All as per Srl item No. 31.00 above but of capacity upto 5 HP, complete all as specified and directed.
M&L in replacement for ball bearing of the induction motor of size/No. 6314/6315 or as per existing/suitable size complete all as specfied and directed.
All as per srl item No. 35.00 above but of size NU 308/7308BG, complete all as specified and directed.
All as per srl item No. 35.00 above but of size 6309, complete all as specified and directed.
M&L for against replacement of worn out Graphite gland packing pump 10mmx10mm or as per existing size complete all as specified and directed.
M&L for PCC 1:3:6, type C-2, using 40 mm graded crushed stone aggregate for foundation of suitable size or as per site requirement including demolition of old PCC foundation complete all as specified and directed. Note: The debris after demolition of PCC should be removed complete and spread to area where directed.
S&F in replacement of the unserviceable contactor 3 pole of AC3 rating upto 115 Amp or as per existing rating and 220 V/415V coil rating complete with all new wiring including thimbles and lugs nuts and screws complete all as specified and directed.
S&F in replacement of the unserviceable timer switch suitable for 240/415 Volts 3-30 Sec, 50 Hz complete all as specified and directed.
M&L for against replacement of worn out / defective thermal overload relay with range 78-130A Amps 415 V, 50 Hz, complete all as specified and directed.
S&F, testing commissioning in replacement of monoblock pumpset with motor of discharge 5.8 Lps and 72m head, 2900 rpm, complete all as specified and directed. Note: Old monoblock pump dismantled at site will be deposited in MES store by contractor.
M&L for powder coated perforated MS cable tray size 450x50mm 14SWG including horizontal and vertical bends, reducer tees, cross member and other accessories as required with fasteners complete all as specified and directed.
Supplying, laying, jointing and testing in replacement of existing size with PVC cable unarmoured multi standard copper conductor of size 70 sqmm, 3 core and connected with suitable and required copper thimbles and nut bolts to panels and Booster pump, complete all as specified and directed.
All as per srl item No 45.00 above but of size 35sqmm, complete all as specified and directed.
All as per srl item No 45.00 above but of size 16sqmm, complete all as specified and directed.
Demolition of Cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) or under the over head tank/road cutting etc complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8, type D-2, using 40mm graded crushed stone aggregate as in path, paving etc. finished even and smooth using extra cement complete all as specified and directed.
Collecting Sample of water from bore well for "Chemical & Bacteriological tests " from approved laboratory and submitting to Engineer-in-Charge complete all as specified and directed.
M&L for taking out pump set along with column pipe flanged 40/50 mm bore with submersible cable from bore hole of tube well with the help of chain pulley block or tripod by dismantling nut bolts and rubber gaskets complete all as specified and directed.
M&L for lowering down pump set along with column pipe flanged 40/50 mm bore with submersible cable from bore hole of tube well with the help of chain pulley block or tripod by assembling nut bolts and rubber gaskets complete all as specified and directed.
M&L for taking out the pumpset and transportation for repairing motor pump set to workshop, taking out burnt winding wire from submersible motor of capacity 5 HP 3 phase, rewinding with suitable size of PVC coated copper winding wire including replacement of burnts bushes complete including all insulation material and transportation back to site and fixing the same, testing and commissiong complete all as specified and directed. Note: (i) Any fault such as short cicuit, earth fault, burning of submersible cable due to unbalance load or any other reason occur in the motor after repair during the currency of contract will be bear by the contractor and quoted rates are deemed to be included in the item for rectification of the fault. (ii) Spares for replacement will be measured and paid separately under respective items
All as per srl item No 54.00 above but of capacity 3 HP, complete all as specified and directed.
M&L for replacement of bearing bush for submersible motor of capacity 3/5 HP, complete all as specified and directed.
All as per Srl item No. 56.00 above but for rotor sleeve, complete all as specified and directed.
All as per Srl item No. 56.00 above but for thrust bearing pad, complete all as specified and directed.
All as per Srl item No. 56.00 above but for thrust plate.
All as per Srl item No. 56.00 above but for motor coupling with key.
All as per Srl item No. 56.00 above but for upper bearing housing assembly.
All as per Srl item No. 56.00 above but for lower bearing housing assembly.
All as per Srl item No. 56.00 above but for motor base.
M&L for replacement of impeller of submersible pump capacity 3/5 hp complete.
All as per Srl item no 64.00 above but for neck ring.
All as per Srl item no 64.00 above but for distance sleeve stainless steel.
All as per Srl item no 64.00 above but for pump shaft.
All as per Srl item no 64.00 above but for bearing existing.
M&L for dismantling of horizontal multistage centrifugal pump set complete of capacity 100 HP, transporting to workshop and replacing defective parts, removing iron scales cleaning the serviceable parts and re-assembling in existing state after carrying out necessary repair / replacement of worn out defective parts and making serviceable and taken back to site for assembling with motor and testing on full load complete all as specified and directed. Note: Spares for replacement will be measured and paid separately under respective items
M&L for replacement Impeller as per existing
All as per Srl item no 70.00 above but for Pump Shaft as per existing
All as per Srl item no 70.00 above but for Stage casing as per existing
All as per Srl item no 70.00 above but for Shaft Sleeve as per existing
All as per Srl item no 70.00 above but for Lantern Ring as per existing
All as per Srl item no 70.00 above but for Inter stage bush as per existing
All as per Srl item no 70.00 above but for O ring as per existing
All as per Srl item no 70.00 above but for Oil seal as per existing
All as per Srl item no 70.00 above but for Distance sleeve as per existing
S&F Joist, channel, angle, or tee sections, fixed independently with welding, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of Fe-410W(GdeE-250) qualityB against worn out channel, angle iron etc complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer including prepration on steel surfaces of any description over 10 cm width or girth complete all as specified and directed.
S&F in replacement galvanised concertina coil (for protection from monkeys and other animals), laid on ground around the reservoir/water tank complete all as specified and directed. Note:- Size and dia of concertina coil shall be as directed by EIC.
S&F against replacement DOL starter of capacity 5 HP , 415 V , 50 Hz 3 Phase complete all as specified and directed.
S&F against replacement RB 198-10 flex pin and bush type coupling of existing shaft size complete all as specified and directed.
M&L for shifting of LT panel at Pump house to desired location as directed by Engr-in-charge after disconnecting the electric connections and reconnecting the proper electric connections complete.
M&L for taking out the settled sedimental materials from reservoir, silt, other foreign material from tank complete and depositing and thrown where directed at a distance not exceeding 50 meter, including repairing leakage chemical treatment where leakage portion and de-watering, cleaning with iron brushes, including internal and external white washing with two coats of lime wash using duly mixed 0.5% copper sulphate and DDL etc complete (internally & externally) and painting the complete railing and MS pipe connected to reservoir with one coat of black bituminous paint after preparation of complete surface of the RCC open static tank of capacity 10,00,000 gallons located at near MH Jutogh complete complete all as specified and directed.
All as per Srl item no. 85.00 above but for capacity of tank 5,00,000 gallons located at near MES JCO's mess pocket 'D' area, complete all as specified and directed.
All as per Srl item no 85.00 above but for capacity of tank 2,50,000 gallons located at near Robert Height ASCON NODE down side, complete all as specified and directed.
All as per Srl item no 85.00 above but for capacity of tank 1,00,000 gallons, complete all as specified and directed.
All as per Srl item no 85.00 above but for capacity of RCC Semi UG sump 1,20,000 gallons at near Yadgar gate pump house complete all as specified and directed.
All as per Srl item no 85.00 above but for capacity of RCC Semi UG sump 1,00,000 gallons at near MH Jutogh complete all as specified and directed.
All as per Srl item no 85.00 above but for capacity of RCC tank 30,000 gallons at Jutogh main pump house complete all as specified and directed.
All as per Srl item no 85.00 above but for capacity of RCC tank 20,000 gallons at near MH Sanjauli & Sanjauli cantt complete all as specified and directed.
All as per Srl item no 85.00 above but for capacity of RCC tank 10,000 gallons complete all as specified and directed.
All as per Srl item no 85.00 above but for capacity of RCC tank 8,000 gallons located at Kelvin Grove complete all as specified and directed.
M&L for taking out the complete settled materials from steel water tank of capacity 30,000 gallons near Mata Mandir and cleaning all the surfaces internally and externally with iron brushes welding where broken body with steel plate/channel and painting the complete tank and inlet, outlet connection with two coats of synthetic enamel paint after preparation of the surface made suitable for drinking water complete all as specified and directed.
All as per Srl item no 95.00 above but for tank of capacity 20,000 gallons located at 304(I) Supply depot, complete all as specified and directed.
R. P. Suppliers and Construction Co. (BID ID -3162184)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .